Bacharach PCA400 Quick Start Guide

®
Front Side
1
2
Warm Up: 60 seconds
4
9
6
10
3
1 Pistol-Grip Probe
2 PCA® 400 Combustion Analyzer
3 Sample Line with Quick Connectors
4 Water Trap & Filter Assembly
5 IrDA Communications Port (Not Shown)
6 Full Color LCD Touch Screen
7
8
WARNING: This analyzer is not intended to be used as a safety device.
7 Back, Home & Power Keys (Left to Right)
8 Navigation & Enter Keys
9 Micro-B USB Connector
10 T-Air Connector
11 T-Stack Connector & Sample Ports
12 Pressure Low Side (-∆P)
IMPORTANT: Ensure that the water trap assembly is clean, dry, and properly assembled.
IMPORTANT: Check for obvious signs of splits and / or cracks in the tubing.
Bottom
11
12
IMPORTANT: Ensure that the analyzer has sucient
charge before operation. If in doubt, recharge lithium-ion battery, replace disposable batteries, or provide power via the AC adapter and USB cable.
60-SECOND
IMPORTANT: Perform power up and initialization in fresh air to ensure proper calibration.
IMPORTANT: Address / acknowledge any faults or errors discovered during initialization.
WARNING: This analyzer has not been designed to be
intrinsically safe for use in areas classied as hazardous
locations.
IMPORTANT: Perform routine maintenance (replacing sensors, calibrating, etc.) as outlined in the PCA® 400 User Manual (P/N 0024-9551).
A B
Warning: When testing an appliance, a full visual inspection should be performed to ensure its safe operation.
CAUTION: The probe may be hot after analysis and can cause bodily harm and or damage the analyzer. Allow the
probe sucient time to cool before handling or storing in
the supplied instrument case.
A B
A B
x
IMPORTANT: Use only original equipment components with this device.
CAUTION: Except for sensor and battery replacement, this analyzer should only be opened and / or serviced by authorized Bacharach personnel. Failure to comply may void the warranty.
The Sample Conditioner extracts
WAIT FOR
RESULTS TO
STABILIZE
ON
®
PCA
400 Active
ERROR
Sample Conditioner
BACHARACH, INC. NEW KENSINGTON, PA 15068 USA TELEPHONE: 1-724-334-5000 www.MyBacharach.com
MADE IN THE USA
POWER: 12-15 VDC, 3A
P/N: 0024-XXXX
S/N:
Sample Conditioner
Viton® Sample Line
IrDA + Bluetooth®
Printer
Printer Paper
Water Trap Filters
O2 Sensor
CO
Sensor
LOW
CO
Sensor
HIGH
SO2 Sensor
NO2 Sensor
NO Sensor
Description:
P/N:
Description:
P/N:
Description:
P/N:
P/N 0024-1310 (contains 5 rolls of paper)
P/N 0007-1644 (contains 3 lters)
P/N 0024-1652
P/N 0024-1687
P/N 0024-1542
P/N 0024-1543
P/N 0024-1544
P/N 0024-1691
water vapor from samples, allowing the PCA® 400 to accurately read levels of NO2 and or SO2.
0024-7400
7.5' Viton® Sample Line with quick connectors allows the PCA® 400 to accurately read levels of NO2 and or SO2.
0024-3236
The IrDA + Bluetooth® Printer allows technicians to print reports directly from the PCA® 400 without a wired connection.
0024-1680
Loading...