2
Warm Up: 60 seconds
4
9
6
10
3
1 Pistol-Grip Probe
2 PCA® 400 Combustion Analyzer
3 Sample Line with Quick Connectors
4 Water Trap & Filter Assembly
5 IrDA Communications Port (Not Shown)
6 Full Color LCD Touch Screen
7
8
WARNING: This analyzer is not intended to be used as a
safety device.
7 Back, Home & Power Keys (Left to Right)
8 Navigation & Enter Keys
9 Micro-B USB Connector
10 T-Air Connector
11 T-Stack Connector & Sample Ports
12 Pressure Low Side (-∆P)
IMPORTANT: Ensure that the water trap assembly is
clean, dry, and properly assembled.
IMPORTANT: Check for obvious signs of splits and / or
cracks in the tubing.
Bottom
11
12
IMPORTANT: Ensure that the analyzer has sucient
charge before operation. If in doubt, recharge lithium-ion
battery, replace disposable batteries, or provide power
via the AC adapter and USB cable.
60-SECOND
WARM-UP
IMPORTANT: Perform power up and initialization in
fresh air to ensure proper calibration.
IMPORTANT: Address / acknowledge any faults or errors
discovered during initialization.
WARNING: This analyzer has not been designed to be
intrinsically safe for use in areas classied as hazardous
locations.
IMPORTANT: Perform routine maintenance (replacing
sensors, calibrating, etc.) as outlined in the PCA® 400 User
Manual (P/N 0024-9551).
A B
Warning: When testing an appliance, a full visual inspection should be performed to ensure
its safe operation.
CAUTION: The probe may be hot after analysis and can
cause bodily harm and or damage the analyzer. Allow the
probe sucient time to cool before handling or storing in
the supplied instrument case.
A B
A B
x
IMPORTANT: Use only original equipment components
with this device.
CAUTION: Except for sensor and battery replacement,
this analyzer should only be opened and / or serviced by
authorized Bacharach personnel. Failure to comply may
void the warranty.
The Sample Conditioner extracts
WAIT FOR
RESULTS TO
STABILIZE
ON
®
PCA
400 Active
ERROR
Sample Conditioner
BACHARACH, INC.
NEW KENSINGTON, PA 15068 USA
TELEPHONE: 1-724-334-5000
www.MyBacharach.com
MADE IN THE USA
POWER: 12-15 VDC, 3A
P/N: 0024-XXXX
S/N:
Sample Conditioner
Viton® Sample Line
IrDA + Bluetooth®
Printer
Printer Paper
Water Trap Filters
O2 Sensor
CO
Sensor
LOW
CO
Sensor
HIGH
SO2 Sensor
NO2 Sensor
NO Sensor
Description:
P/N:
Description:
P/N:
Description:
P/N:
P/N 0024-1310 (contains 5 rolls of paper)
P/N 0007-1644 (contains 3 lters)
P/N 0024-1652
P/N 0024-1687
P/N 0024-1542
P/N 0024-1543
P/N 0024-1544
P/N 0024-1691
water vapor from samples, allowing
the PCA® 400 to accurately read
levels of NO2 and or SO2.
0024-7400
7.5' Viton® Sample Line with quick
connectors allows the PCA® 400 to
accurately read levels of NO2 and
or SO2.
0024-3236
The IrDA + Bluetooth® Printer allows
technicians to print reports directly
from the PCA® 400 without a wired
connection.
0024-1680