MGS Series Controller Manual
WARRANTY POLICY
BACHARACH, INC. WARRANTS THIS INSTRUMENT, EXCLUDING SENSORS, TO BE
FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE
YEAR FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER. THE SENSORS
HAVE A WARRANTY PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE. IF
THE PRODUCT SHOULD BECOME DEFECTIVE WITHIN THIS WARRANTY PERIOD,
WE WILL REPAIR OR REPLACE IT AT OUR DISCRETION.
THE WARRANTY STATUS MAY BE AFFECTED IF THE INSTRUMENT HAS NOT BEEN
USED AND MAINTAINED PER THE INSTRUCTIONS IN THIS MANUAL OR HAS BEEN
ABUSED, DAMAGED, OR MODIFIED IN ANY WAY. THIS INSTRUMENT IS ONLY TO BE
USED FOR PURPOSES STATED HEREIN. THE MANUFACTURER IS NOT LIABLE FOR
AUXILIARY INTERFACED EQUIPMENT OR CONSEQUENTIAL DAMAGE.
DUE TO ONGOING RESEARCH, DEVELOPMENT, AND PRODUCT TESTING, THE
MANUFACTURER RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT
NOTICE. THE INFORMATION CONTAINED HEREIN IS BASED ON DATA CONSIDERED
ACCURATE. HOWEVER, NO WARRANTY IS EXPRESSED OR IMPLIED REGARDING
THE ACCURACY OF THIS DATA.
ALL GOODS MUST BE SHIPPED TO THE MANUFACTURER BY PREPAID FREIGHT.
ALL RETURNED GOODS MUST BE PRE-AUTHORIZED BY OBTAINING A RETURN
MERCHANDISE AUTHORIZATION (RMA) NUMBER. CONTACT THE MANUFACTURER
FOR A NUMBER AND PROCEDURES REQUIRED FOR PRODUCT TRANSPORT.
SERVICE POLICY
BACHARACH, INC. MAINTAINS AN INSTRUMENT SERVICE FACILITY AT THE
FACTORY. SOME BACHARACH DISTRIBUTORS / AGENTS MAY ALSO HAVE REPAIR
FACILITIES, HOWEVER, BACHARACH ASSUMES NO LIABILITY FOR SERVICE
PERFORMED BY ANYONE OTHER THAN BACHARACH PERSONNEL. REPAIRS ARE
WARRANTED FOR 90 DAYS AFTER DATE OF SHIPMENT (SENSORS, PUMPS,
FILTERS AND BATTERIES HAVE INDIVIDUAL WARRANTIES). SHOULD YOUR
INSTRUMENT REQUIRE NON-WARRANTY REPAIR, YOU MAY CONTACT THE
DISTRIBUTOR FROM WHOM IT WAS PURCHASED OR YOU MAY CONTACT
BACHARACH DIRECTLY.
IF BACHARACH IS TO DO THE REPAIR WORK, SEND THE INSTRUMENT, PREPAID,
TO BACHARACH, INC. AT THE FOLLOWING ADDRESS.
BACHARACH, INC.
621 HUNT VALLEY CIRCLE
NEW KENSINGTON, PA 15068
ATTENTION: SERVICE DEPARTMENT
ALWAYS INCLUDE YOUR RMA #, ADDRESS, TELEPHONE NUMBER, CONTACT
NAME, SHIPPING/BILLING INFORMATION AND A DESCRIPTION OF THE DEFECT AS
YOU PERCEIVE IT. YOU WILL BE CONTACTED WITH A COST ESTIMATE FOR
EXPECTED REPAIRS PRIOR TO THE PERFORMANCE OF ANY SERVICE WORK. FOR
LIABILITY REASONS, BACHARACH HAS A POLICY OF PERFORMING ALL NEEDED
REPAIRS TO RESTORE THE INSTRUMENT TO FULL OPERATING CONDITION.
2 6709-9000 Rev 2
PRIOR TO SHIPPING EQUIPMENT TO BACHARACH, CONTACT OUR OFFICE FOR AN
RMA # (RETURNED MERCHANDISE AUTHORIZATION). ALL RETURNED GOODS
MUST BE ACCOMPANIED WITH AN RMA NUMBER.
PACK THE EQUIPMENT WELL (IN ITS ORIGINAL PACKING IF POSSIBLE), AS
BACHARACH CANNOT BE HELD RESPONSIBLE FOR ANY DAMAGE INCURRED
DURING SHIPPING TO OUR FACILITY.
NOTICES
MGS Series Controller Manual
COPYRIGHTS: THIS MANUAL IS SUBJECT TO COPYRIGHT PROTECTION; ALL
RIGHTS ARE RESERVED UNDER INTERNATIONAL AND DOMESTIC COPYRIGHT
LAWS. THIS MANUAL MAY NOT BE COPIED OR TRANSLATED, IN WHOLE OR IN
PART, IN ANY MANNER OR FORMAT, WITHOUT THE WRITTEN PERMISSION OF
BACHARACH, INC.
ALL SOFTWARE WHICH BACHARACH UTILIZES AND/OR DISTRIBUTES, HOLDS A
PROPRIETARY INTEREST AND IS ALSO SUBJECT TO COPYRIGHT PROTECTION
AND ALL RIGHTS ARE RESERVED. NO PARTY MAY USE OR COPY SUCH
SOFTWARE IN ANY MANNER OR FORMAT, EXCEPT TO THE EXTENT THAT
BACHARACH GRANTS THEM A LICENSE TO DO SO. IF THIS SOFTWARE IS BEING
LOADED ONTO MORE THAN ONE COMPUTER, EXTRA SOFTWARE LICENSES MUST
BE PURCHASED.
TECHNICIAN USE ONLY
THIS UNIT MUST BE INSTALLED BY A SUITABLY QUALIFIED TECHNICIAN W HO WILL
INSTALL THIS UNIT IN ACCORDANCE WITH THESE INSTRUCTIONS AND THE
STANDARDS IN THEIR PARTICULAR INDUSTRY/COUNTRY. OPERATORS OF THE
UNIT SHOULD BE AWARE OF THE REGULATIONS AND STANDARDS IN THEIR
INDUSTRY/COUNTRY FOR THE OPERATION OF THIS UNIT. THESE NOTES ARE
ONLY INTENDED AS A GUIDE AND THE MANUFACTURER BEARS NO
RESPONSIBILITY FOR THE INSTALLATION OR OPERATION OF THIS UNIT.
FAILURE TO INSTALL AND OPERATE THE UNIT IN ACCORDANCE WITH THESE
INSTRUCTIONS AND WITH INDUSTRY GUIDELINES MAY CAUSE SERIOUS INJURY
INCLUDING DEATH AND THE MANUFACTURER WILL NOT BE HELD RESPONSIBLE
IN THIS REGARD.
HAZARDOUS AREA WARNING
THIS INSTRUMENT HAS NOT BEEN DESIGNED TO BE INTRINSICALLY SAFE FOR
USE IN AREAS CLASSIFIED AS HAZARDOUS LOCATIONS. FOR YOUR SAFETY, DO
NOT USE IT IN HAZARDOUS (CLASSIFIED) LOCATIONS.
4.9.MUTING THE AUDIBLE ALARM (KEY SWITCH) ................................................... 24
4.10.RESETTING HIGH ALARMS (DUAL-LEVEL UNITS ONLY) ..................................... 25
DECLARATION OF CONFORMITY .................................................................. 27
4 6709-9000 Rev 2
Section 1. Introduction
1.1. Overview
The MGS Series controllers provide local alarm status indications (via
multi-colored, per-channel LEDs) as well as single-level or dual-level
digital (relay) alarm outputs based on 1, 2, 4, or 6 input signals and 1 or
2 user-definable set-points.
1.2. 2-Channel and 6-Channel Models
MGS Controllers support multiple input sensors/transmitters (1, 2, 4, or 6
channels) based on the model of the controller. Inputs are standard 4-20
mA signals from MGS-series sensors or any standard, linear, 4-20 mA
transmitter.
NOTE: The smaller MGS Controller supports up to two input
channels (see Figure 1). The larger controller supports up to
six channels (see Figure 2). The number of alarm LEDs on
your controller will vary based on the flavor of device that is
ordered.
MGS Series Controller Manual
IMPORTANT: If you are NOT using the maximum number of
available channels (2 for the smaller controller, and 6 for the
larger controller), you must connect a 3300 Ω resistor across
pins 1 and 2 for each unused input channel.
1.3. Alarming
Regardless of the number of channels supported, each controller
contains either 1 or 2 adjustable potentiometers (pots) for setting the
alarm value(s). Single-level alarm controllers contain one pot which sets
the controller’s alarm threshold. Dual-level alarm controllers contain two
pots which are used to set the low-level and high-level alarm thresholds.
As an individual channel’s input signal exceed the controller’s alarm
threshold (set by the programmable pot(s)), the corresponding channel’s
alarm LED is illuminated, allowing a technician to visually inspect the
controller for any alarm conditions on a channel-by-channel basis.
6709-9000 Rev 2 5
MGS Series Controller Manual
Figure 1. Sample Configurations (1,2-Channel)
6 6709-9000 Rev 2
MGS Series Controller Manual
Figure 2. Sample Configurations (4,6-Channel)
MGS Controllers have either one or two relay outputs: one for singlelevel alarm controllers (“Alarm”), and 2 for dual-level alarm controllers
(“Alarm High” and “Alarm Low”). Unlike the alarm LEDs that provide a
channel-by-channel alarm status of each incoming transmitter’s signal,
the relay output “trips” or “energizes” if any of the inputs exceed the
alarm threshold set by the pot (that is, if any of the alarm LEDs is
energized). Alarm relays can be used to activate warning lights, sirens,
ventilation fans, etc.
6709-9000 Rev 2 7
MGS Series Controller Manual
For dual-alarm configurations, the Alarm Low relay output “trips” or
“energizes” if any of the inputs exceed the alarm threshold set by the low
alarm pot. Similarly, the Alarm High relay output “trips” or “energizes” if
any of the inputs exceed the alarm threshold set by the high alarm pot.
All controllers have a green power LED that is on when the unit has
power. The 4- and 6-channel 2-level units have a fault relay which “trips”
or “energizes” if the controller experiences a fault condition. Like the
alarm relays, the fault relay can be use to activate warning lights, sirens,
ventilation fans, etc.
1.4. Components
The following is a summary of the MGS Controller’s hardware
components. Note that features vary based on model and features (e.g.,
1-2 channel units vs. 4-6 channel units, single-level alarms vs. dual-level
alarms, etc.).
Components Descriptions
Power input Provides power to the MGS Controller
Power LED Power status indicator
Channels (max) 1-2 Channel Units 4-6 Channel Units
Sensor input(s) max 2 max 6 max
Alarm levels Single Dual Single Dual
Set point POT(s) 1 2 1 2
Alarm relay output(s) 1 2 1 2
Alarm LED(s) (max) 2 4 6 12
Fault relay output N/A N/A N/A 1
NOTE: For single-alarm configurations, the Low Alarm LEDs
are not present.
8 6709-9000 Rev 2
1.5. Specifications
Specification 1-2 Channel 4-6 Channel
MGS Series Controller Manual
Product Type 1-2 channel alarm
controller
Max Channels 2 6
Inputs 4-20 mA 4-20 mA
Display LED alarm indicators LED alarm indicators
Ambient
-20 to +50 degrees C -20 to +50 degrees C
Temperature
Range
Power Supply 100V-230V AC (50-60Hz)
or 12V DC (Specify at time
of order)
Max Power 15 W Max 25 W Max
Audible Alarm Integrated 12 VDC
Alarm Set
points
User selectable. Common
to all channels. Alarm
level set point is based on
4-20 mA input signal.
Alarm Relays One 10-A 30 VDC or 250
VAC resistive Form C
relay. Two for dual-alarm
configurations. Common
low alarm and high alarm
across channels.
Housing NEMA 1 wall mount NEMA 1 wall mount
Approvals UL/CSA/IEC/EN 61010-1
CE
4-6 channel alarm
controller
100V-230V AC (50-60Hz)
or 12V DC (Specify at time
of order)
User selectable. Common
to all channels. Alarm
level set point is based on
4-20 mA input signal.
One 10-A 30 VDC or 250
VAC resistive Form C
relay. Two for dual-alarm
configurations. Common
low alarm and high alarm
across channels.
Common fault relay on
dual-level alarm
configurations.
UL/CSA/IEC/EN 61010-1
CE
NOTE: If replacement of either main power fuse is required,
use only a 2A 250V slow fuse (0.79 in/20mm) T2AL250V.
6709-9000 Rev 2 9