MGD
Standard
Housing
o
i
1
n
0
S
0
y
s
t
t
c
e
t
e
D
s
a
G
D
G
M
Ideal for Chiller Rooms, Supermarkets, Brewing and
Bottling Facilities, Industrial Refrigeration, Arenas,
Food Storage and Processing Facilities.
Features & Benefits:
Stand-alone, out-of-the-box solution with quick and easy
installation - the most cost-effective system available.
Fast-response sensors detect leaks quickly, which
minimize refrigerant gas usage and environmental impact.
Infrared (NDIR) CO2 detection
Long-life semiconductor sensors for detection of all
refrigerants, ammonia, halocarbons, combustibles & VOCs
Robust design allows units to be placed directly in areas
where detection is needed.
Available in a variety of housings, including IP66 and duct
mount.
e
m
Select from 1, 2, 4 or 6 remote sensors and 1 or 2 pre-set
alarm levels, which can be connected to BMS systems.
Flexible and Dynamic Continuous Monitoring
Bacharach’s MGD-100 Series is a robust and scalable gas detection system used for
reliable real-time monitoring of refrigerant, combustible, and toxic gases. It’s a
stand-alone system that alarms when pre-set thresholds are exceeded. The MGD-100’s
alarms are monitored by a centralized controller, which can alert personnel of potential
hazardous conditions via an onboard buzzer and LED alarm indicators.
MGD-100 Systems can be configured from single-sensor, one-alarm level systems to
larger scale systems consisting of 6 sensors with 2 alarm levels. This flexibility allows the
platform to be used for both small and large systems. Optional MGD-100 housings are
shown below:
IP66
Housing
Airflow /
Duct Mount
IP66 with
Splash Guard
IP66 with
Remote Head
IP66 with Exd
Remote Head
IP66 with
PRV
MGD
Controller
Exd
(ATEX only)
1 - 800- 736- 4666 | 724- 334- 5000 | www.MyBacharach.com | help@MyBacharach.com
MGD-100 Technical Specifications
Controller with 1 or 2 Sensors Controller with 4 or 6 Sensors
Power Supply:
Alarm Levels:
Power Monitoring:
Visual Alarm:
Fault Monitoring:
Audible Alarm:
Buzzer Deactivate:
Alarm Relay
(Volt-free):
Relay Expander
Box (one relay for
each sensor/alarm
level):
Alarm Reset:
Delayed Response:
Power-On Delay:
Ratings:
Cabling,
Controller-toSensor:
Dimensions &
Weight:
Dimensions &
Weight - other
enclosures:
Approvals:
Distributed By:
Available in 110VAC 60Hz • 12VDC • 220VAC 50Hz
One Level
Green LED
Red LED
Red LED,
relay, siren
inactive
Internal buzzer
continuous
By onboard
jumper
10 amp@ 120v
or 230v
N/A
Automatic when
gas clears
Selectable (3
mins. when on)
3 minutes to stabilize from power-up; slightly longer from storage.
Controller: IP51
4 wire shielded cable, 200 feet
(61 m) max, 22AWG @ 120VAC
• 0.2mm
Standard Controller:
8.4” x 4.1” x 3.15”
214 x 105 x 80 mm
2.9 lbs. / 1.3 kg
Sensor:
3.4” x 4.73” x 2.08”
86 x 120 x 53 mm
0.33 lbs. / 150 g
Standard:
IP66:
IP66 w/Splash: 6.89”x8.9”x3.29” / 1lb. 8.7oz. •
IP66 w/Remote: 6.89”x6.1”x3.29” / 1lb. 11oz.
IP66 w/EXd: 6.89”x6.1”x3.29” / 2lb. 10oz.
PRV / IP66:
Airflow/Duct: 6.89”x4.9”x3.29” / 1lb. 4oz.
EXd:
CE • UL 61010-1 • CAN/CSA 22.2 61010-1
Two Levels
Green LED
Red LED
Red LED,
relay, siren
inactive
Internal buzzer
intermittent (low)
continuous (high)
By key switch
10 amp@ 120v
or 230v (both low
& high level)
N/A
Automatic when
gas clears (low),
Latch out, manual
reset by push
button when gas
clears (high)
25 seconds (low)
30 seconds
Standard Sensor:
IP41
3.35”x5.59”x2.09” / 6.3oz. •
6.89”x6.5”x3.29” / 1lb. 6oz.
6.89”x6.1”x3.29” / 2lb. 0.3oz. •
5.12”x6.3”x3.54” / 9lb. 4oz.
,
(high)
One Level
Green LED
Red LED
Red LED,
relay, siren
inactive
External buzzer
continuous
By onboard
jumper
10 amp@ 120v
or 230v
N/A
Automatic when
gas clears
Selectable (3
mins. when on)
Controller: IP51 Standard Sensor:
4 wire shielded cable, 500 feet
(152 m) max, 22AWG @ 120VAC
• 0.2mm
Standard Controller:
10.3” x 10.4” x 3.3”
262 x 265 x 84 mm
5.7 lbs. / 2.6 kg
Sensor:
3.4” x 4.73” x 2.08”
86 x 120 x 53 mm
0.33 lbs. / 150 g
• 175 x 165 x 82mm / 629g
• 175 x 155 x 82mm / 790g
• 175 x 155 x 82mm / 1185g
• 175 x 125 x 82mm / 578g
• 130 x 160 x 90mm / 4200g
Two Levels
Green LED
Red LED
Red LED,
relay, siren
inactive, fault
relay active
External buzzer
continuous
By key switch
10 amp@ 120v
or 230v (both low
& high level)
Available
Automatic when
gas clears (low),
Latch out, manual
reset by push
button when gas
clears (high)
25 seconds (low)
30 seconds
IP41
86 x 142 x 53mm / 180g
175 x 225 x 82mm / 700g
175 x 155 x 82mm / 916g
(high)
MGD-100 Sensor Information
Temperature Range:
Humidity
(non-condensing)
Sensor Life:
Time to Alarm:
Recovery Time:
Semiconductor Sensor
* Full sensor detection range: 0 - 10,000 ppm
-4° F to 122° F
-20° C to 50° C
-40° F to 122° F
-40° C to 50° C
0 - 95%
:
5 years, typical
30 seconds, typical
210 seconds, typical
Carbon Dioxide (CO2)
Hydrocarbons
Refrigerants, HFC, CFCs, HCFCs:
including R134a, R404a, R407a,
R410a, R507a, R11, R12, R22,
R32, R600a, R290 and many more
Ammonia (NH3)
Hydrogen (H2)
Hydrocarbons:
Ethylene, methane and more
VOCs:
including
Trichloroethylene and more
MGD-100 Ordering Information
Infrared Sensor - Common Configurations
6150-4090
6170-1090
6130-2090
6170-1051
6130-1051
6150-4051
6150-2116
6150-4116
6170-3117
6110-1101
6130-2101
6150-1103
6170-2103
6130-1105
6130-2107
6170-1107
6130-1111
6130-2119
6170-1119
6110-1114
6170-4120
6170-1121
6110-2121
CO2 IR: 4 sensors, 2 alarms, 110VAC, IP66 w/Remote Sensor
CO2 IR: 6 sensors, 2 alarms, 110VAC, Standard Housing
CO2 IR: 2 sensors, 2 alarms, 110VAC, IP66 Housing
IR Combustible Gas • 6 sensors, 2 alarms, 110VAC, IP66 Housing
IR Combustible Gas • 2 sensors, 2 alarms, 110VAC, Standard Housing
IR Combustible Gas • 4 sensors, 2 alarms, 110VAC, IP66 w/Remote Sensor
Semiconductor Sensor - Common Configurations
NH3: 4 sensors, 2 alarms, 110VAC, IP66 Housing
NH3: 4 sensors, 2 alarms, 110VAC, IP66 w/Remote Sensor
NH3: 6 sensors, 2 alarms, 110VAC, IP66 Housing w/Splash Guard
R134a: 1 sensor, 2 alarms, 110VAC, Standard Housing
R134a: 2 sensors, 2 alarms, 110VAC, IP66 Housing
R404a: 4 sensors, 2 alarms, 110VAC, Standard Housing
R404a: 6 sensors, 2 alarms, 110VAC, IP66 Housing
R407a: 2 sensors, 2 alarms, 110VAC, Standard Housing
R410a: 2 sensors, 2 alarms, 110VAC, IP66 Housing
R410a: 6 sensors, 2 alarms, 110VAC, Standard Housing
R507a: 2 sensors, 2 alarms, 110VAC, Standard Housing
H2: 2 sensors, 2 alarms, 110VAC, IP66 Housing
H2: 6 sensors, 2 alarms, 110VAC, Standard Housing
CH4: 1 sensor, 2 alarms, 110VAC, Standard Housing
Ethylene: 6 sensors, 2 alarms, 110VAC, IP66
VOC:
6 sensors, 2 alarms, 110VAC, Standard
VOC:
1 sensor, 2 alarms, 110VAC, IP66
Please contact your Bacharach sales representative for other
configurations based on your unique specifications.
Infrared (NDIR) Sensor
(Standard housing)
(Standard housing)
(IP66 housing)
(IP66 housing)
Gas(es) DetectedInfrared (NDIR) Sensor Programmed Detection Range
(Combustibles)
Gas(es) Detected
Acetone, Methanol,
Semiconductor Sensor
-4° F to 122° F
-20° C to 50° C
-40° F to 122° F
-40° C to 50° C
0 - 95%
5 - 8 years, typical
24 seconds, typical
600 seconds, typical
0 - 5,000 ppm
0 - 10,000 ppm
0 - 20,000 ppm
0 - 30,000 ppm
0 - 50,000 ppm
0 - 1% vol
0 - 100% LEL, 0 - 100% vol
Programmed Detection Range*
1,000 ppm*
500 ppm - 1,000 ppm*
0 - 2,000 ppm*
0 - 2,000 ppm*
0 - 2,000 ppm*
w/Remote Sensor
Housing
Housing
(Standard housing)
(Standard housing)
(IP66 housing)
(IP66 housing)
BACHARACH IS A U.S.
BASED MANUFACTURER
Bacharach® is a registered trademark of Bacharach, Inc.
All rights reserved. All information is subject to verification.
June 2014 - Rev. 1 Printed in USA