GAS DETECTOR and CONTROLLER
QUICK INSTALLATION GUIDE
P/N: 6109-9002
Revision 0
January 13, 2016
Standard
IP41 Sensor
Housing
1-2 Sensor
Controller Housing
CAUTION: DO NOT MOUNT the
MGD-100 in an area that may
contain flammable liquids or
vapors. Operaon of electrical
equipment in such an area constutes a safety hazard.
WARNING: Strictly follow the
instrucons in the User Manual
(part number 6109-9000) available
at www.MyBacharach.com.
1: OPERATING AREA AND CONDITIONS
The Bacharach MGD-100 is an instrument for the
connuous monitoring of refrigerant, combusble,
and toxic gases. The system is available with one or
two levels of alarm, and consists of 1 to 6 remote gas
sensors connected to and powered by a controller.
The controller is powered by 12 VDC or 100-230 VAC
50-60 Hz (specified at me of order).
2: SAFETY INSTRUCTIONS
USER MANUAL: Before using this equipment,
carefully read and strictly follow the User Manual
(part number 6109-9000). The user must fully
understand and strictly observe the instrucons.
Use the equipment only for the purposes listed and
under the condions specified in that document.
CODE COMPLIANCE: Comply with all local and
naonal laws, rules and regulaons associated with
this equipment.
GENUINE PARTS: Use only genuine Bacharach spare
parts and accessories, otherwise proper funconing
of the equipment may be impaired.
TECHNICIAN USE ONLY: This unit must be installed
by a suitably qualified technician who will install this
unit in accordance with these instrucons and the
standards in their parcular industry/country. Operators of the unit should be aware of the regulaons
and standards in their industry/country for the
operaon of this unit. These notes are only intended
as a guide and the manufacturer bears no responsibility for the installaon or operaon of this unit.
Failure to install and operate the unit in accordance
with these instrucons and with industry guidelines
may cause serious injury including death and the
manufacturer will not be held responsible in this
regard.
SAFE MOUNTING: This monitor must be connected
by a marked, suitably located and easily reached
switch or circuit-breaker as means of disconnecon.
3: WEIGHTS AND DIMENSIONS
Type/Enclosure Dimensions Weights
IP41
IP66
IP66 w/ Splash
Guard
IP66 w/ Remote
Sensor
IP66 w/ Ex d
Remote Head
IP66 w/ PRV
Sensor Head
IP66 Airflow/
Duct (See Table)
Ex d (Enclosure)
3.35” x 5.59” x 2.09”
86 x 142 x 53 mm
6.89” x 6.5” x 3.29”
175 x 165 x 82 mm
6.89” x 8.9” x 3.29”
175 x 225 x 82 mm
6.89” x 6.1” x 3.29”
175 x 155 x 82 mm
6.89” x 6.1” x 3.29”
175 x 155 x 82 mm
6.89” x 6.1” x 3.29”
175 x 155 x 82 mm
6.89” x 4.9” x 3.29”
175 x 125 x 82 mm
5.12” x 6.3” x 3.54”
130 x 160 x 90 mm
Supported CFM & Duct Sizes for Duct Mount Housing
Units
Inches
Feet
Area (ft2)
12 x 12 12 x 24 18 x 18 24 x 24 24 round
1 x 1
1 2 2.25 4 3.14
Duct Size
1 x 2 1.5 x 1.5 2 x 2 Pi x 1 x 1
6.3 oz
180 g
1 lb 6 oz
629 g
1 lb 9 oz
700 g
1 lb 11 oz
790 g
2 lb 10 oz
1185 g
2 lb 0.3 oz
916 g
1 lb 4 oz
578 g
9 lb 4 oz
4200 g
3.39 in (86.0 mm)
Standard
IP41 Housing
4: MOUNTING
ENVIRONMENTAL CONSIDERATIONS: Care-
0.28 in
(7.0 mm)
1.69 in (43.0 mm)
�
0.18 in
(4.50 mm)
2.09 in (53 mm)
fully consider the full range of environmental
condions to which the instruments will be
exposed.
�
0.35 in
(9.0 mm)
TARGET GAS CONSIDERATIONS: The physical
data of the gas or vapor to be detected must
be observed.
APPLICATION CONSIDERATIONS: The specifics
of the applicaon (for example, possible leaks,
air movement/dra, etc.) must be observed.
ACCESSIBILITY CONSIDERATIONS: The degree
of accessibility required for maintenance
purposes must be granted.
4.07 in (103.50 mm)
�
018 in
(4.50 mm)
4.72 in (120 mm)
ACCESSORY CONSIDERATIONS: The types of
oponal and accessory equipment that will be
used with the system must be kept in mind.
ELECTRONIC CONSIDERATIONS: The system
contains sensive electronic components that
0.31 in
(8.0 mm)
1.0 in
(25.00 mm)
1.4 in
(36.00 mm)
1.0 in
(25.00 mm)
can be easily damaged. Do not touch nor
disturb any of these components.
Mount the MGD-100 and Controller according
to the above consideraons, product dimensions (see Secon 3), maximum wiring lengths
(see Secon 5), and the corresponding mount-
Screw
0.2 in
(5.0 mm)
0.4 in (9.0 mm)
0.6 in
(15.5 mm)
2.0 in
(50.0 mm)
ing dimensions shown in the illustraons that
follow.
3.5 in
(90 mm)
5.4 in
(138 mm)
2 x Clearance for M6
Mounng Holes
4.8 in
(122 mm)
5.1 in
(130 mm)
Ex d Housing
5.9 in (151 mm)
5.1 in (130 mm)
6.3 in (160 mm)
0.6 in
(15.0 mm)
0.5 in (12.7 mm)
0.4 in (10.0 mm)
1-2 Sensor
Controller
Housing
2.9 in (74.5 mm)
10.26 in (260.50mm)
Mounng
Hole
Screw
0.2 in
(4.8 mm)
0.6 in (15.0 mm)
0.5 in (12.7 mm)
5.13 in (130.25 mm)
O 0.20 in (5.10 mm)
IP66 Housing
5.7 in
4.8 in
(123 mm)
mounng slots =
0.35 in (9mm) long x
4.0 in
0.24 in (6mm) wide
(101 mm)
Use 3/16-inch screws
(5mm - 6mm )
1.7 in
(42 mm)
2.3 in
(59 mm)
5.7 in
(146 mm)
(144 mm)
M42 thread
Exd Remote
Head
PRV/IP66
Vent Pipe
Monitoring 1
in BSP Head
1”BSP thread
9.47 in (240.50 mm)
8.85 in (224.70 mm)
4-6 Sensor
Controller Housing
O 0.18 in (4.60 mm)
9.55 in (242.50 mm)
5: WIRING
CABLE OPENINGS: The metal IP51 controller
housing provides a number of PG7 openings for
cable glands or plugs. Each MGD-100 IP41 transmitter will have a single opening for an M20 cable
gland, as well as an oponal knockout opening.
Each MGD-100 IP66 tranmier has 3 openings
These openings can be used for field wiring, direct
aachment of a sensor or wiring of a remote
sensor. Unused openings must be closed with a
suitable plug and gasket, maintaining the IP or Ex d
rang.
NOTE: To make wiring connecons,
you must first open the MGD-100
housing. The enclosure lid of the IP66
housing has four capve screws.
Refer to the User Manual (part number 6109-
9000) at www.MyBacharach.com for detailed
instrucons on accessing the internal components
for wiring.
WARNING: The mains power supply
cable should be of an approved type
based on local regulaons. Connecon to the mains power supply
must be made via an approved,
readily-accessible, switched and
fused plug and socket (or as per
local wiring regulaons) which
should be within 10 feet (3 meters)
of the control unit.
SHIELD WIRE WARNING: Con-
nect the shield of the power wires
to the earth ground of the central
control system (e.g., chassis,
ground bus bar, etc.).
1: Strip 0.2 to 0.25 inches (5 to 7 mm)
of wiring insulaon.
2: Connect the wires as indicated.
NOTE: Aer wiring is completed,
carefully re-assemble the enclosure
and its components, nong the
keyed ribbon cable and sensor
connectors. Aer installaon is
complete, be sure to refer to the
User Manual (part number 6109-
9000) for detailed instrucons on
registering the sensors and configuring the MGD-100 for proper operaon.
Volt Free
Alarm
Relay
Relay
NC COM NO
HIGH
SAFE
ON
B
m
r
a
l
A
FAIL
u
e
l
KEY
z
z
e
r
A
u
d
b
i
OFF
RED
RED
LED (Opt.)
Chan 2 Alm
SENSOR 2
ON OFF
SENSOR 1
ON OFF
Channel 2
(Oponal)
Channel 1
Chan 1
Alarm LED
GRN
Fuse 2
Fuse 1
Mains
Power
Controller PCB
MAINS
Transformer
12V
2 Channel 1 Alarm
50/60Hz
ON
NC COM NO
High Relay
RED
Chan 4
Alarm LED
Mains
Power
Horn
(12 VDC, 200 mA Max)
MAINS
Fuse
12V
PSU
+ 12V -
RED
GRN
Chan 1
Alarm LED
SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 SENSOR 5 SENSOR 6
ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF
- SIREN +
Chan 2
Alarm LED
KEY
RED
REPLACE FUSE
WITH M205
T2AL250V
OFF
Chan 3
Alarm LED
Fuse
FAIL SAFE
RED
Key
Switch
RED
Chan 5
Alarm LED
500 (152 m) max;
22 AWG; Max 8.8Ω/wire
4-conductor cable (stranded);
Fail Safe Jumper Seng:
ON
ON: High Relay Is Normally
Energized (De-energized on
High Alarm or Mains
Failure Condion)
OFF
OFF: High Relay Is Energized
On Alarm (Energized on High
Alarm Condion)
To Lid
Ground
Connecon
Base Ground
Connecon
RED
Chan 6
Alarm LED
SC
SENSOR
IR Gas Sensor PCB
ON
OFF
ON
OFF
RV1
Jumper Seng:
Fail Safe
ON: High Relay Is
Normally Energized
(De-energized on
High Alarm or Mains
Failure Condion)
OFF: High Relay Is
Energized On Alarm
(Energized on High
Alarm Condion)
Relay
Output
Sensor Enable
Jumper Sengs:
ON: Sensor is
enabled for this
channel
OFF: Sensor is
disabled for this
channel
High Alarm
Relay
(Volt Free)
Low Alarm
Relay
(Volt Free)
Mains
Power
GRN
Relay 2
NC COM NO
HIGH
Relay 1
Fuse 2
Controller PCB
ON
m
r
a
l
NC COM NO
Fuse 1
FAIL
SAFE
u
B
A
e
l
LOW
KEY
RESET
SENSOR 2
ON OFF
RED
OFF
z
z
e
r
YEL
A
u
Chan 2 Alm LEDs (Opt.)
d
b
i
RED
SENSOR 1
ON OFF
Channel 2
(Oponal)
Channel 1
YEL
Chan 1 Alarm LEDs
GRN
MAINS
Transformer
12V
2 Channel 2 Alarm
Horn
(12 VDC, 200 mA Max)
MAINS
Fuse
12V
PSU
+ 12V -
YEL
RED
Chan 1
Alarm LEDs
SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 SENSOR 5 SENSOR 6
ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF
- SIREN +
YEL
Chan 2
Alarm LEDs
KEY RESET
RED
REPLACE FUSE
WITH M205
T2AL250V
YEL
Chan 3
Alarm LEDs
Fuse
OFF
FAIL SAFE
RED
Mains
Power
Key
Switch
50/60Hz
ON
NC COM NO
NC COM NO
High Relay Low Relay Fault Relay
YEL
Chan 4
Alarm LEDs
YEL
RED
Chan 5
Alarm LEDs
RED
500 (152 m) max;
22 AWG; Max 8.8Ω/wire
4-conductor cable (stranded);
Fail Safe Jumper Seng:
ON
ON: High Relay Is Normally
Energized (De-energized on
High Alarm or Mains
Failure Condion)
OFF
OFF: High Relay Is Energized
On Alarm (Energized on High
Alarm Condion)
To Lid
Ground
Connecon
Push
Buon
Switch
Base Ground
Connecon
NO COM NC
YEL
RED
Chan 6
Alarm LEDs
SC Gas Sensor PCB
SC
SENSOR
RV1
IR Gas Sensor PCB
ON
OFF
ON
Fail Safe
Jumper Seng:
ON: High Relay Is
Normally Energized
(De-energized on
High Alarm or Mains
Failure Condion)
OFF: High Relay Is
Energized On Alarm
(Energized on High
Alarm Condion)
Relay
Outputs
Sensor Enable
Jumper Sengs:
ON: Sensor is
enabled for this
channel
OFF
OFF: Sensor is
disabled for this
channel
World Headquarters
621 Hunt Valley Circle
New Kensington, PA 15068 USA
Phone: 724-334-5000 • Fax: 724-334-5001
Toll Free: 1-800-736-4666
Website: www.MyBacharach.com
E-mail: help@MyBacharach.com
114A Georges Street Lower
Dun Laoghaire • Co Dublin • Ireland
Phone: +353 1 284 6388 • Fax: +353 1 284 6389
Repeat for sensor
channels 3 through
6 as required.
4-conductor cable (stranded) (6 places max);
500 (152 m) max; 22 AWG; Max 8.8Ω/wire
Ensure that connecons 1 to 4
RV1
on each sensor connect to their
corresponding numbers on the
terminal block in the main
alarm unit, otherwise the
system will not funcon
correctly and could be
damaged.
RV1
4-conductor cable (stranded) (6 places max);
500 (152 m) max; 22 AWG; Max 8.8Ω/wire
Ensure that connecons 1 to 4
on each sensor connect to their
corresponding numbers on the
terminal block in the main
alarm unit, otherwise the
system will not funcon
correctly and could be
damaged.
6 Channel 1 Alarm
Repeat for sensor
channels 3 through
6 as required.
6 Channel 2 Alarm