THD Series
Temperature/Humidity Transducer
Room/Wall Mount/Duct Mount Type
Temperature/HumidityTransducer
Features
● Compact design
● Built-in temp./humidity sensor
● 7 Segment LED Display (THD-DD/THD-WD)
● Various output modes
DC4-20mA, 1-5VDC, RS485 (Modbus RTU)
● Wide range of temp./humidity measurement
-19.9 to 60.0℃ / 0.0 to 99.9%RH
THD-R
● Communication speed: 115200bps
Please read “Safety Considerations” in operation
manual before using.
Ordering Information
THD D CD 1
Output
Length of sensor pole
Display
Mounting
Item
Specications
Model
Power supply
Allowable voltage range
Power consumption
Sensor type Temperature sensor Temperature/Humidity sensor
Display type Non-indicating type
Display digit
Character size
Measurement
range
Accuracy
Temp. -19.9 to 60.0
Humidity
Temp. Max. ±0.8
※
1
Humidity
Temp.
Output
Humidity
Resolution
Sampling cycle
Insulation resistance
Dielectric strength
Noise immunity
※
1: •Room temperature is 23℃±5℃.
•It may cause degree of degradation when this unit is exposed to organic chemicals such as alcohol gas or sulfuric acid.
•It may cause degree of degradation for humidity when using this unit at high temperature/humidity environment for a long time.
• It may cause error of humidity value when this unit is exposed to high humidity environment (over 80%RH) for a long time.
THD-R-PT THD-R-PT/C
-
-
-
24VDC
90 to 110% of rated voltage
Max. 2.4W
-
-
℃
-
℃
-
0.0 to 99.9%RH (THD-R is required to attend for using over 90%RH.)
±1.0℃ (at room temperature)
±3%RH (30 to 70%RH, at room temp.),
±4%RH (10 to 90%RH)
DPt100Ω resistance value
(TCR: 3850ppm/
℃)
DC4-20
-
(allowable impedance:
max. 600Ω)
-
-
-
-
-
1/1000
0.5 sec
Over 100MΩ (at 500VDC megger)
500VAC 50/60Hz for 1 minute
±0.3kV the square wave noise (pulse width: 1㎲) by the noise simulator
※
PT
PT/C※DPt100Ω resistance value (Temp.) / Current output (Humidity)
C Current output (Temp./Humidity)
V Voltage output (Temp./Humidity)
T RS485 communication output (Temp./Humidity)
No mark※Built-in
1 100
2 200
No mark Non-Display type
D Display type
R Room type (for indoor)
D Duct mounting type
W Wall mounting type
THD Temperature Humidity Double
※
It is only for THD-R.
ᜡ
mA
THD-DD
THD-D
(only for THD- -T model)
DPt100Ω resistance value (Temp.)
mm
mm
THD-R-C
THD-R-V
THD-R-T
THD-D
THD-W
Typ. ±2%RH (10 to 90%RH, at room temp.)
※
Max. ±2.5%RH
DC4-20mA(allowable impedance: max. 600Ω), 1-5VDCᜡ,
RS485 communication (Modbus RTU)
THD-WD
THD-DD
THD-WD
7-segment LED display
Each 3 digits for
temp./humidity
W6.2×H10.0
THD-W
mm
H-147
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software

THD Series
Specications
Model
Vibration
Shock
Protection structure IP10 IP65 (except sensing part)
Ambient temperature -20 to 60℃, storage: -20 to 60
Cable
Approval , (only for THD- -T model)
Weight
※
※
Mechanical
Malfunction
Mechanical
Malfunction
2
※
2: The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
Dimensions
THD-R
THD-R-PT THD-R-PT/C
-
-
-
-
-
Approx. 98g (approx. 55g) Approx. 415g (approx. 160g)
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
℃
THD-R-C
THD-R-V
THD-R-T
THD-D
THD-W
Ø4mm, 4-wire, Length: 2m
(AWG22, Core diameter: 0.08mm, number of
cores: 60, insulation out diameter: Ø1.25mm)
THD-DD
THD-WD
(unit: mm)
60
THD-W
85A71
72
58
Ø15
80
30.5
4-Ø4.8
Ø4, 2m
34.5
●Panel cut-out
2-M3
67.8
4-Ø4.8
85
4-Ø4.5
THD-D
71
Bracket
72
58
2-M3
34.5 A
20
10
4
Ø4, 2m
●Panel cut-out
58
Ø15
4-M4
Model Length of sensor pole (A)
THD- 1- 100mm
THD- 2- 200mm
H-148
55
Ø22
Ø15.2
Ø70
71

Connections
THD-R
Power
&Output
terminal
※
Check the terminal connection
diagram and be sure that when
connecting the power.
THD-D / THD-W
DC4-20mA (Humi.)
Power &Output
terminal
THD-D-C /
THD-W-C
(Temp.)
Temperature/Humidity Transducer
THD-R-PT
A
3
TEMPERATURE
SENSOR
DPt100Ω SIGNAL OUT
B
2
B'
1
THD-R-C, V, T
DC4-20mA 1-5VDC RS485
4
(Humi.)
3
(Temp.)
2
24VDC 2.4W
1
THD-D-V /
THD-W-V
1-5VDC (Humi.)
24VDC 2.4W
B (-)
A (+)
(Temp.)
24VDC 2.4W
THD-R-PT/C
A
6
B
5
B'
4
3
2
1
THD-D-T /
THD-W-T
RS485
(Temp. &Humi.)
A (+)B (-)
TEMPERATURE
SENSOR
DPt100Ω SIGNAL OUT
DC4-20mA
(Humi.)
24VDC 2.4W
24VDC 2.4W
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
White White WhiteBlack Black BlackBlue Blue BlueBrown Brown Brown
Case Detachment
THD-R
Unfasten the bolt on the bottom of the product, separate the
case from it.
THD-D / THD-W
Unfasten 4 bolts on the top of the product, separate
cover from it.
the case
H-149
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software