Autonics SRS1-A SERIES Instruction Manual

DR W1 71115 AA
Autonics
Solid State Relay
SRS1-A SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
Failure to follow these instructions may result in serious injury or death.
Warning Caution
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
3. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
4. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Since leakage current still ows right after turning off the power or in the output OFF status, do not touch the load terminal.
Failure to follow this instruction may result in electric shock.
Model
00
Model Rated input voltage Rated load current Rated load volta ge Function
SRS1-A1202
SRS1-A1202R Random turn-on
SRS1-A1203
SRS1-A1203R Random turn-on
SRS1-A1205
SRS1-A1205R Random turn-on
SRS1-A1D101 1A
SRS1-A1D102 2A
SRS1-A1D201
SRS1-A1X201 5-240VAC/5-200VDC
Dimensions
00
When inatalling multiple SSRs, please keep space between SSRs for heat radiation.
The above specifications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
Failure to follow these instructions may result in personal injury or product damage.
Zero cross turn-on
Zero cross turn-on
Zero cross turn-on
-
13
5
4-24VDC
Input indicator
(red LED)
2A
3A
5A
1A
Max. 3A
L 28 38
5A
24-240VAC
5-100VDC
5-200VDC
5.4L 4-0 54-5
4-Ø3
(unit: mm)
29
Connections
SRS1-A1202(R)/A1203(R)/A1205(R)
3
INPUT 4-24VDC
Input
Rated input voltage range 4-24VDC Allowable input voltage range 4-26.4VDC
Output (AC)
Model SRS1-A1202(R) SRS1-A1203(R) SRS1-A1205(R) Rated load voltage range 24-240VACrmsᜠ (50/60Hz) Allowable load voltage range Rated load current Min. load current 0.15Arms 0 2Arms Max. 1 cycle surge current (60Hz) Max. non-repetitive surge current (I²t, t=8.3ms) Peak voltage (non-repetitive) 600V Leakage current (Ta=25℃) Max. 2mArms Output ON voltage drop [Vpk] (max. load current) Static off-state dv/dt 500V/ Turn-on time Turn-off time Max. 0.5 cycle of load source + 1ms
Output(DC, AC/DC)
Model
Rated load voltage range 5-100VDC
Allowable load voltage range
Rated load current Min. load current 10mA Max. surge current (t=10ms) Leakage current (Ta=25℃) Max. 100uA Max. 2mArms Output ON voltage drop [Vpk] (max. load current) Static off-state dv/dt 500V/ Turn-on time Max. 1ms Max. 2ms Max. 1ms Max. 2ms Turn-off time Max. 1ms
General specications
Dielectric strength (Vrms) 2,500VAC 50/60Hz for 1 min (input-output, input/output-case) Insulation resistance Over 100MΩ (at 500VDC megger) Indicator Input indicator: red LED
Environment
Protection IP10 (Protection structure of socket, SK-G05) Approval Weight
1: AC-51 is utilization category at EC60947-4-3.
2:
Environment resistance is rated at no freezing or condensation.
1-------------------i
00
Load current [A]
0.7
0.5
Since effectiveness of the heat rediation is decreased when multiple SSRs are installed closely, please supply less than 50% of the rated load current.
Above SSR derating curves obtained approval from the UL certication authority.
4
5 1
Specications
Resistive load (AC-51)
I
Zero cross turn-on Max. 0.5 cycle of load source + 1ms
I
Random turn-on Max. 1ms
I
Resistive load (AC-51)
I
Ambient temp.
I
Ambient humi.
I
2
The weight is per 10 units with packing and the weight of parenthesis is per 1 unit.
SSR Derating curve
SRS1-A1205(R)
5
I
4
3
2
1
I
SRS1-A1203(R)
SRS1-A1202(R)
I
I
10 20 30 40 50 60 70
SRS1-A1202(R)
: 240VAC 2A RESISTIVE LOAD SRS1-A1203(R) : 240VAC 3A RESISTIVE LOAD SRS1-A1205(R) : 240VAC 5A RESISTIVE LOAD
Max. input
15mA
24-264VACrmsᜠ (50/60Hz)
2Arms 3Arms 5Arms
1
126A 250A
65A²s 400A²s
Max. 1.6V
SRS1-A1D101 SRS1-A1D102 SRS1-A1D201 SRS1-A1X201
3-120VDC
1Adc 2Adc 1Adc 1Arms/1Adc
1
5A 10A 4A
Max. 1.1V Max. 2.2V
-20 to 70℃, storage: -30 to 100
depending on ambient temperature. Refer to '
45 to 85%RH, storage: 45 to 85%RH
ᜢ ᜧ
Max. 3A: Approx. 270g (approx. 17g), 5A: Approx. 380g (approx. 28g)
I
1
"'-
·,
....
'
'
I
....
"'·
·····
....
....
"
....
Ambient temperature[℃]
(Random turn-on)
I
I
I
I
SRS1-A1D102
2
1
Load current [A]
SRS1-A1D201/A1X201
0.6
0.3
0.2
800
0 10 20 30 40 50 60
SRS1-A1D101/A1D102/A1D201
NPUT
4-24VDC
Pick-up voltage Min. 4VDC Drop-out voltage Max. 1VDC
I
I
5-200VDC
3-220VDC
(The rated load current capacity is di󰘯erent
5-240VACᜠ (50/60Hz),
5-200VDC 3-264VACᜠ (50/60Hz),
3-220VDC
SSR Derating curve'.)
i.i
Ambient temperature[℃]
3 4
5 1
SRS1-A1D101
70
SRS1-A1D101
: 100VDC 1A RESISTIVE LOAD SRS1-A1D102 : 100VDC 2A RESISTIVE LOAD SRS1-A1D201 : 200VDC 1A RESISTIVE LOAD
Example of Connection
00
● AC load
80
4-24VDC
1: Must use a Varistor. Varistor: 470V, 0 6W
2: When connecting capacitor(CAP) as above, it is appropriate for EMC. CAP: 1uF/250VAC
● DC load(SRS1-A1D101/A1D102/A1D201)
4-24VDC
1: Must use a Varistor. Varistor: 270V, 0.6W(SRS1-A1D101/A1D102)
● AC/DC load (SRS1-A1X201)
4-24VDC
1: Must use a Varistor. Varistor: 470V, 0.6W
Cautions during Use
00
1. Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
2. 4-24VDC signal input should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install the unit in the well ventilated place.
4. While supplying power to the load or right after turning off the power of the load, do not touch the body. Failure to follow this instruction may result in a burn due to the high temperature.
5. In order to protect the product from the short-circuit current of the load, use rapid fuse of which I2t is under the 1/2 of SSR I2t. When short-circuited, replace the fuse to those of same specication with the used rapid fuse.
6. Install dummy resistance in parallel with the load, to keep the sum of current owing in the load and
dummy resistance being over SSR minimum load current.
7. When using random turn-on model for phase control, install noise lter between the load and the
power of the load.
8. Do not use near the equipment which generates strong magnetic force or high frequency noise.
9. This unit may be used in the following environments.
Indoors (in the environment condition rated in ‘Specications’)
Altitude max. 2,000m
Pollution degree 2
Installation category II
Major Products
00
Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Temperature/Humidity Transducers
Door Sensors SSRs/Power Controllers
Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometer/Pulse (Rate) Meters Rotary Encoders Display Units Connector/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, CO₂, Nd: YAG) Laser Welding/Cutting System
5/+
+
Input Output
-
-r:Q
1/- 4
5/+
+
Input
-
r=tJ
1/-
5/+
+
Input
- - +
r]
1/- 4
SRS1-A1X201
3
NPUT
4-24VDC
SRS1
~
SRS1
~(I 1
470V, 0.6W(SRS1-A1D201)
SRS1
~:(I
4
5 1
3
+:
I i : 1 o
3/+
Output
4/-
3
Output
t
SRS1-A1X201
: 240VAC 1A RESISTIVE LOAD : 200VDC 1A RESISTIVE LOAD
Load
1
Varistor
Rapid fuse
Load
1
Varistor
Rapid fuse
~
Load
1
Varistor
Rapid fuse
:00
~
Load
source
(AC)
+
-
CAP
Load
source
(DC)
+
Load
2
~
source
(AC)
-
Load
source
(DC)
DR W1 71115 AA