DR W1 71115 AA
Autonics
Solid State Relay
SRS1-A SERIES
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
※
Please observe all safety considerations for safe and proper product operation to avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
※
Failure to follow these instructions may result in serious injury or death.
Warning
Caution
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause
serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment,
ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster
prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
3. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
4. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct
sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Since leakage current still ows right after turning off the power or in the output OFF status,
do not touch the load terminal.
Failure to follow this instruction may result in electric shock.
Model
00
Model Rated input voltage Rated load current Rated load volta ge Function
SRS1-A1202
SRS1-A1202R Random turn-on
SRS1-A1203
SRS1-A1203R Random turn-on
SRS1-A1205
SRS1-A1205R Random turn-on
SRS1-A1D101 1A
SRS1-A1D102 2A
SRS1-A1D201
SRS1-A1X201 5-240VAC/5-200VDC
Dimensions
00
※
When inatalling multiple SSRs, please keep space between SSRs for heat radiation.
※
The above specifications are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
Failure to follow these instructions may result in personal injury or product damage.
Zero cross turn-on
Zero cross turn-on
Zero cross turn-on
-
13
5
4-24VDC
Input indicator
(red LED)
2A
3A
5A
1A
Max. 3A
L 28 38
5A
24-240VAC
5-100VDC
5-200VDC
5.4L
4-0 54-5
4-Ø3
(unit: mm)
29
Connections
SRS1-A1202(R)/A1203(R)/A1205(R)
3
INPUT
4-24VDC
Input
Rated input voltage range 4-24VDC
Allowable input voltage range 4-26.4VDC
Output (AC)
Model SRS1-A1202(R) SRS1-A1203(R) SRS1-A1205(R)
Rated load voltage range 24-240VACrmsᜠ (50/60Hz)
Allowable load voltage range
Rated load
current
Min. load current 0.15Arms 0 2Arms
Max. 1 cycle surge current (60Hz)
Max. non-repetitive surge
current (I²t, t=8.3ms)
Peak voltage (non-repetitive) 600V
Leakage current (Ta=25℃) Max. 2mArms
Output ON voltage drop [Vpk]
(max. load current)
Static off-state dv/dt 500V/
Turn-on
time
Turn-off time Max. 0.5 cycle of load source + 1ms
Output(DC, AC/DC)
Model
Rated load voltage range 5-100VDC
Allowable load voltage range
Rated load
current
Min. load current 10mA
Max. surge current (t=10ms)
Leakage current (Ta=25℃) Max. 100uA Max. 2mArms
Output ON voltage drop [Vpk]
(max. load current)
Static off-state dv/dt 500V/
Turn-on time Max. 1ms Max. 2ms Max. 1ms Max. 2ms
Turn-off time Max. 1ms
General specications
Dielectric strength (Vrms) 2,500VAC 50/60Hz for 1 min (input-output, input/output-case)
Insulation resistance Over 100MΩ (at 500VDC megger)
Indicator Input indicator: red LED
Environment
Protection IP10 (Protection structure of socket, SK-G05)
Approval
Weight
※
1: AC-51 is utilization category at EC60947-4-3.
※
2:
※
Environment resistance is rated at no freezing or condensation.
1-------------------i
00
Load current [A]
0.7
0.5
Since effectiveness of the heat rediation is decreased when multiple SSRs are installed closely,
please supply less than 50% of the rated load current.
※
Above SSR derating curves obtained approval from the UL certication authority.
4
5 1
Specications
Resistive load
(AC-51)
I
Zero cross turn-on Max. 0.5 cycle of load source + 1ms
I
Random turn-on Max. 1ms
I
Resistive load
(AC-51)
I
Ambient temp.
I
Ambient humi.
I
2
※
The weight is per 10 units with packing and the weight of parenthesis is per 1 unit.
SSR Derating curve
SRS1-A1205(R)
5
I
4
3
2
1
I
SRS1-A1203(R)
SRS1-A1202(R)
I
I
10 20 30 40 50 60 70
SRS1-A1202(R)
※
: 240VAC 2A RESISTIVE LOAD
SRS1-A1203(R)
: 240VAC 3A RESISTIVE LOAD
SRS1-A1205(R)
: 240VAC 5A RESISTIVE LOAD
ᜡ
Max. input
15mA
current
ᜡ
24-264VACrmsᜠ (50/60Hz)
※
2Arms 3Arms 5Arms
1
126A 250A
65A²s 400A²s
Max. 1.6V
㎲
SRS1-A1D101 SRS1-A1D102 SRS1-A1D201 SRS1-A1X201
ᜡ
3-120VDC
ᜡ
※
1Adc 2Adc 1Adc 1Arms/1Adc
1
5A 10A 4A
Max. 1.1V Max. 2.2V
㎲
-20 to 70℃, storage: -30 to 100
depending on ambient temperature. Refer to '
45 to 85%RH, storage: 45 to 85%RH
ᜢ ᜧ
Max. 3A: Approx. 270g (approx. 17g), 5A: Approx. 380g (approx. 28g)
I
1
"'-
·,
....
'
'
I
....
"'·
·····
....
....
"
....
Ambient temperature[℃]
(Random turn-on)
I
I
I
I
℃
SRS1-A1D102
2
1
Load current [A]
SRS1-A1D201/A1X201
0.6
0.3
0.2
800
0 10 20 30 40 50 60
SRS1-A1D101/A1D102/A1D201
NPUT
4-24VDC
Pick-up voltage Min. 4VDC
Drop-out voltage Max. 1VDC
I
I
5-200VDC
3-220VDC
(The rated load current capacity is dierent
5-240VACᜠ (50/60Hz),
ᜡ
5-200VDC
3-264VACᜠ (50/60Hz),
ᜡ
3-220VDC
SSR Derating curve'.)
i.i
Ambient temperature[℃]
3
4
5 1
ᜡ
ᜡ
SRS1-A1D101
70
SRS1-A1D101
※
: 100VDC 1A RESISTIVE LOAD
SRS1-A1D102
: 100VDC 2A RESISTIVE LOAD
SRS1-A1D201
: 200VDC 1A RESISTIVE LOAD
Example of Connection
00
● AC load
ᜡ
ᜡ
80
4-24VDC
1: Must use a Varistor. Varistor: 470V, 0 6W
※
2: When connecting capacitor(CAP) as above, it is appropriate for EMC. CAP: 1uF/250VAC
※
● DC load(SRS1-A1D101/A1D102/A1D201)
4-24VDC
1: Must use a Varistor. Varistor: 270V, 0.6W(SRS1-A1D101/A1D102)
※
● AC/DC load (SRS1-A1X201)
4-24VDC
1: Must use a Varistor. Varistor: 470V, 0.6W
※
Cautions during Use
00
1. Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
2. 4-24VDC signal input should be insulated and limited voltage/current or Class 2, SELV power supply
device.
3. Install the unit in the well ventilated place.
4. While supplying power to the load or right after turning off the power of the load, do not touch the
body.
Failure to follow this instruction may result in a burn due to the high temperature.
5. In order to protect the product from the short-circuit current of the load, use rapid fuse of which I2t is
under the 1/2 of SSR I2t. When short-circuited, replace the fuse to those of same specication with
the used rapid fuse.
6. Install dummy resistance in parallel with the load, to keep the sum of current owing in the load and
dummy resistance being over SSR minimum load current.
7. When using random turn-on model for phase control, install noise lter between the load and the
power of the load.
8. Do not use near the equipment which generates strong magnetic force or high frequency noise.
9. This unit may be used in the following environments.
①
Indoors (in the environment condition rated in ‘Specications’)
②
Altitude max. 2,000m
③
Pollution degree 2
④
Installation category II
Major Products
00
■
Photoelectric Sensors Temperature Controllers
Fiber Optic Sensors Temperature/Humidity Transducers
■
Door Sensors SSRs/Power Controllers
■
Door Side Sensors Counters
Area Sensors Timers
Proximity Sensors Panel Meters
Pressure Sensors Tachometer/Pulse (Rate) Meters
Rotary Encoders Display Units
Connector/Sockets Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System (Fiber, CO₂, Nd: YAG)
Laser Welding/Cutting System
5/+
+
Input Output
-
-r:Q
1/- 4
5/+
+
Input
-
r=tJ
1/-
5/+
+
Input
- - +
r]
1/- 4
■
■
■
■
■
■
■
■
■
SRS1-A1X201
3
NPUT
4-24VDC
SRS1
~
SRS1
~(I 1
470V, 0.6W(SRS1-A1D201)
SRS1
~:(I
4
5 1
3
+:
I i : 1 o
3/+
Output
4/-
3
Output
t
SRS1-A1X201
※
: 240VAC 1A RESISTIVE LOAD
: 200VDC 1A RESISTIVE LOAD
Load
1
※
Varistor
Rapid fuse
Load
1
※
Varistor
Rapid fuse
~
Load
1
※
Varistor
Rapid fuse
:00
~
Load
source
(AC)
+
-
CAP
Load
source
(DC)
+
Load
2
※
~
source
(AC)
-
Load
source
(DC)
DR W1 71115 AA