Autonics SRH1 Operating Manual

DRW160914AC
Single-Phase, Integrated Heatsink Type SSR
[Voltage Input Type]

Model

Model Rated input voltage Rated load current Rated load voltage Function
SRH1-1210-N 4-30VDC
SRH1-2210-N 24VAC
SRH1 SERIES
I N S T R U C T I O N M A N U A L
SRH1-4210-N 90-240VAC
SRH1-1215-N 4-30VDC
SRH1-4215-N 90-240VAC
SRH1-1220-N 4-30VDC
SRH1-4220-N 90-240VAC
SRH1-1230-N 4-30VDC
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
SRH1-4230-N 90-240VAC
SRH1-1240-N 4-30VDC

Safety Considerations

Please observe all safety considerations for safe and proper product operation to avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
Failure to follow these instructions may result in serious injury or death.
Warning
Failure to follow these instructions may result in personal injury or product damage.
Caution
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Install on a device panel or DIN rail to use.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct
sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Since leakage current still ows right after turning off the power or in the output OFF status,
do not touch the load terminal.
Failure to follow this instruction may result in electric shock.

Dimensions

Rated load current
10A/15A/20A
22.5
Ø4.5
3.5
80
Input indicator
3.5
Rated load current 60A
2-Ø4.5
4.5
3.5 3.5
The above specifications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
90
(green)
100
110
81.5
Rated load current
30A/40A
45
3.5
Ø4.5
14.3
45
4.54.5
3.5
3.53.5
4.5
80
90
100
Input indicator
(green)
Input indicator
(green)
80
90
100
100
31
100
31
SRH1-4240-N 90-240VAC
SRH1-1260-N 4-30VDC
SRH1-4260-N 90-240VAC
SRH1-1410-N
SRH1-1410R-N Random turn-on
SRH1-2410-N 24VAC Zero cross turn-on
SRH1-1415-N
SRH1-1415R-N Random turn-on
SRH1-2415-N 24VAC Zero cross turn-on
SRH1-1420-N
SRH1-1420R-N Random turn-on
SRH1-2420-N 24VAC Zero cross turn-on
SRH1-1430-N
SRH1-1430R-N Random turn-on
SRH1-2430-N 24VAC Zero cross turn-on
SRH1-1440-N
SRH1-1440R-N Random turn-on
SRH1-2440-N 24VAC Zero cross turn-on
SRH1-1460-N
SRH1-1460R-N Random turn-on
SRH1-2460-N 24VAC Zero cross turn-on
Panel cut-out
Rated load current
10A/15A/20A/30A/40A
Screw tightening torque for mounting: 1.8 to 2.5N.m
Spacing
When installing multiple SSRs, please keep space between SSRs for heat radiation. When installing SSRs horizontally (input
part and output part on the same height),
please supply less than 50% of the rated load current.
2-M4907
100
100
100
Specications
Input
Rated input voltage range
10A
Allowable input voltage range
Max. input current 18mA
15ASRH1-2215-N 24VAC
20ASRH1-2220-N 24VAC
24-240VAC Zero cross turn-on
30ASRH1-2230-N 24VAC
Pick-up voltage Min. 4VDC
Drop-out voltage Max. 1VDC
Zero cross
Turn-on time
turn-on Random turn-on
Turn-off time
Output
Rated load voltage range
Allowable load voltage range
4-30VDC
4-30VDC
40ASRH1-2240-N 24VAC
60ASRH1-2260-N 24VAC
10A
15A
Zero cross turn-on
Zero cross turn-on
Rated load current
Min. load current 0.15Arms 0.15Arms 0.2Arms 0.5Arms 0.5Arms 0.5Arms Max. 1 cycle surge current
(60Hz)
Max. non-repetitive surge current (I2t, t=8.3ms) Peak voltage
(non-repetitive)
Leakage current (Ta=25℃) Output on voltage drop
[Vpk] (max. load current)
Static off state dv/dt 500V/
Rated load voltage range
Resistive load
(AC-51)
Allowable load voltage range
4-30VDC
4-30VDC
4-30VDC
4-30VDC
20A
30A
40A
60A
48-480VAC
Zero cross turn-on
Zero cross turn-on
Zero cross turn-on
Zero cross turn-on
Rated load current
Min. load current 0.5Arms 0.5Arms 0.5Arms 0.5Arms 0.5Arms 0.5Arms Max. 1 cycle surge current
(60Hz)
Max. non-repetitive surge current (I2t, t=8.3ms) Peak voltage
(non-repetitive)
Leakage current (Ta=25℃) Output on voltage drop
[Vpk] (max. load current)
Static off state dv/dt 500V/
1: AC-51 is utilization category at IEC60947-4-3.
General specications
Resistive load
(AC-51)
Dielectric strength (Vrms)
Insulation resistance Over 100MΩ (at 500VDC megger) (input-output, input/output-case)
Indicator Input indicator: green LED
Rated load current
81.5
Panel
60A
4-M4
90
77
DIN rail mounting
DIN rail attachment
(unit: mm)
Vibration
Shock
Environment
Input terminal connection
Output terminal connection
Input terminal xed torque 0.75 to 0.95N.m
Mechanical
Malfunction
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Ambient temperature
Ambient humidity
Output terminal xed torque
20
DIN rail must be grounded.
DIN rail detachment
35mm
DIN rail
Approval
1
Weight
1: The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
For wiring the terminal, round terminal must be used.

Connections

Panel
35mm
DIN rail
(-) driver
High Temperature Caution
While supplying power to the load or right after turning off the power of the load, do not touch the body and heat sink. Failure to follow this instruction may result in a burn due to the high temperature.
Power supply
(AC, DC)
Use terminals of size specied below.
Terminal type Rated load current
<Round>
4-30VDC
4-32VDC
Max. 0.5 cycle of load source + 1ms
Max. 1ms
Max. 0.5 cycle of load source + 1ms
24-240VACrmsᜠ (50/60Hz)
24-264VACrmsᜠ (50/60Hz)
10Arms 15Arms 20Arms 30Arms 40Arms 60Arms
1
160A 160A 250A 400A 500A 1000A
130A2s 130A2s 300A2s 910A2s 1000A2s 4000A2s
600V
Max. 10mArms (240VACᜠ/60Hz)
Max. 1.6V
48-480VACrmsᜠ (50/60Hz)
48-528VACrmsᜠ (50/60Hz)
10Arms 15Arms 20Arms 30Arms 40Arms 60Arms
1
300A 300A 300A 500A 500A 1000A
350A2s 350A2s 350A2s 1000A2s 1000A2s 4000A2s
1200V (Zero cross turn-on), 1000V (Random turn-on)
Max. 10mArms (480VACᜠ/60Hz)
Max. 1.6V
2500VAC 50/60Hz 1 min (input-output, input/output-case)
0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z
direction for 1 hour
0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z
direction for 10 min
-30 to 80℃ (in case of the rated input voltage 90-240VACᜠ: -20 to 70℃), storage: -30 to 100℃ (
The rated load current capacity is different depending on ambient temperature. Refer to ' SSR Derating Curve'.
45 to 85%RH, storage: 45 to 85%RH
Min. 1×0.5mm2 (1×AWG20), Max. 1×1.5mm2 (1×AWG16) or 2×1.5mm2 (2×AWG16)
Rated load current 10A/15A/20A : Min. 1×0.75mm2 (1×AWG18), max. 1×4mm2 (1×AWG12) or 2×2.5mm2 (2×AWG14) Rated load current 30A/40A/60A : Min. 1×1.5mm2 (1×AWG16), max. 1×16mm2 (1×AWG6) or 2×6mm2 (2×AWG10)
Use wires compliant with load current capacity to connect to the terminal.
Rated load current 10A/15A/20A: 1.0 to 1.35N·m Rated load current 30A/40A/60A: 1.6 to 2.2N·m
ᜢ ᜧ
Rated load current 10A/15A/20A: approx. 298g (approx. 225g) Rated load current 30A/40A: approx. 500g (approx. 410g) Rated load current 60A: approx. 770g (approx. 680g)
4/A2- 2/L1
Input Output
3/A1+ 1/T1
Input 10A, 15A, 20A, 30A, 40A, 60A 10A, 15A, 20A 30A, 40A, 60A
a Min. 3.5mm Min. 4.0mm Min. 5.0mm
a
b
b Max. 7.0mm Max. 9.0mm Max. 12.0mm
24VACrms (50/60Hz)
19-30VACrms
(50/60Hz)
15mArms (24VACrmsᜠ)
Min. 19VACrms
Max. 4VACrms Max. 2 cycle of load
source + 1ms
- -
Max. 2 cycle of load source + 1ms
)
SSR Module
SRH1 series
Output
Load
Rapid fuse
90-240VACrms (50/60Hz)
85-264VACrms
(50/60Hz)
18mArms (240VACrmsᜠ)
Min. 85VACrms
Max. 10VACrms Max. 2 cycle of load
source + 1ms
Max. 2 cycle of load source + 1ms
Load
power source
(AC)

SSR Derating Curve

SRH1-1210/2210/4210-N
30
20
Load current[A]
10
5 0
0
10 20 2530 40 50 60 70 80 90
SRH1-1210/2210-N
SRH1-4210-N
Ambient temperature[℃]
SRH1-1215/2215/4215-N
30
20
15
Load current[A]
10
5 0
0
10 20 2530 40 50 60 70 80 90
SRH1-1215/2215-N
SRH1-4215-N
Ambient temperature[℃]
SRH1-1220/2220/4220-N
30
20
Load current[A]
10
5
0
0
10 20 30 40 50 60 70 80 90
SRH1-1220/2220-N
SRH1-4220-N
Ambient temperature[℃]
SRH1-1230/2230/4230-N
30
20
Load current[A]
10
9
0
0
10
SRH1-1230/2230-N
SRH1-4230-N
40
2520 30
50 60 70 80 90
Ambient temperature[℃]
SRH1-1240/2240/4240-N
60
40
Load current[A]
20 12
0
0
10 203040 50 60 70 80 90
SRH1-1240/2240-N
SRH1-4240-N
35
Ambient temperature[℃]
SRH1-1260/1460/1460R-N
SRH1-2260/2460/4260-N
60
40
26
Load current[A]
20
0
0
10 20 30 40 50 60 70 80 90
SRH1-4260-N
35
Ambient temperature[℃]
SRH1-1410/1410R/2410-N
30
20
Load current[A]
10
8
0
0
10 20
3530 40
50 60 70 80 90
Ambient temperature[℃]
SRH1-1415/1415R/2415-N
30
20
15
Load current[A]
10
8
0
0
10 20 50 60 70 80 90
3530 40
Ambient temperature[℃]
SRH1-1420/1420R/2420-N
30
20
Load current[A]
10
8
0
0
10 20 30 40 50 60 70 80 90
35
Ambient temperature[℃]
SRH1-1430/1430R/2430-N
30
20
16
Load current[A]
10
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
SRH1-1440/1440R/2440-N
60
40
Load current[A]
20
8 0
0
10 203040 50 60 70 80 90
Ambient temperature[℃]
Since effectiveness of the heat radiation is decreased when multiple SSRs are installed closely, please supply less than 50% of the rated load current.
Above SSR derating curves obtained approval
from the UL certication authority.

Cautions during Use

1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 4-30VDC, 24VAC signal input should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install the unit in the well ventilated place.
4.
Ground to the heat sink, panel, or DIN rail. Failure to follow this instruction may result in electric shock.
5. While supplying power to the load or right after turning off the power of the load, do not touch the body and heat sink. Failure to follow this instruction may result in a burn due to the high temperature.
6. In order to protect the product from the short-circuit current of the load, use rapid fuse of which I2t is under the 1/2 of SSR I2t. When short-circuited, replace the fuse to those of same specication with the used rapid fuse.
7. Install dummy resistance in parallel with the load, to keep the sum of current owing in the load
and dummy resistance being over SSR minimum load current.
8. When using random turn-on model for phase control, install noise lter between the load and the
power of the load.
9. Do not use near the equipment which generates strong magnetic force or high frequency noise.
10. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
Altitude max. 2,000m

Major Products

Photoelectric Sensors Temperature Controllers Fiber Optic Sensors Door Sensors SSRs/Power Controllers Door Side Sensors Counters Area Sensors Timers Proximity Sensors Panel Meters Pressure Sensors Tachometers/Pulse (Rate) Meters Rotary Encoders Display Units Connectors/Sockets Sensor Controllers Switching Mode Power Supplies Control Switches/Lamps/Buzzers I/O Terminal Blocks & Cables Stepper Motors/Drivers/Motion Controllers Graphic/Logic Panels Field Network Devices Laser Marking System (Fiber, Co₂, Nd:YAG) Laser Welding/Cutting System
Temperature/Humidity Transducers
Pollution degree 2
HEADQUARTERS:
18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232
E-mail:
sales@autonics.com
④ Installation category III
http://www.autonics.com
DRW160914AC
Loading...