Autonics SR2 SERIES, SR3 SERIES Instruction Manual

DRW161053AC
Autonics
3-Phase,
Detachable Heatsink/Intergrated Heatsink Type SSR
SR2/SR3 SERIES
I N S T R U C T I O N M A N U A L
Detachable heatsink type Integrated heatsink type
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
symbol represents caution due to special circumstances in which hazards may occur.
ii==============-
Warning
Caution
Warning
A
1.
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
5. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct
sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Keep metal chip, dust, and wire residue from owing into the unit.
Failure to follow this instruction may result in re or product damage.
5. Since leakage current still ows right after turning off the power or in the output OFF status, do
not touch the load terminal.
Failure to follow this instruction may result in electric shock.
Ordering Information
00
SR
H 3
Item
Connections
3-phase (2-pole)
R S T
1/L1
3/L2
2/T1
4/T2
For DC signal input models, 8 and 10 terminals are connected inside.
For AC signal input models, 8 and 10 terminals are insulated inside.
Use terminals of size specied below.
Terminal type
I
~
※
The above specifications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
Thank you for choosing our Autonics product.
Failure to follow these instructions may result in serious injury or death.
Failure to follow these instructions may result in personal injury or product damage.
1
15 R
4
-
Control phase
Type
Rapid
fuse
5/L3
heaing deec ion
6/T3
Load
<Round>
/A1
Input circut
8/A2-
9/AL
Over
0/AL-
circut
a
b
Function
Rated input current (resistive load)
Rated load voltage
Rated input voltage
3-phase (3-pole) delta connection ( -connection)
R S T
Power
supply
(AC, DC)
1/L1
3/L2
-
LOAD
-
2/T1
Input
Min.
Max.
4/T2
3.5mm
7 0mm
Alarm out (NPN open colector output)
a
r-1--I
b
5/L3
6/T3
_j__l
No mark
Zero cross turn-on
R Random turn-on
15 15A 50 50A 30 30A 75 75A 40 40A
2 24-240VAC 4 48-480VAC
1 4-30VDC 2 24VAC 4 90-240VAC
2 3-phase (2-pole) 3 3-phase (3-pole)
No mark Detachable heatsink type H Integrated heatsink type
SR Solid State Relay
3-phase (3-pole) star connection (Y-connection)
Rapid
fuse
Load
Output
Min.
Max.
Input ci cu t
Over
heaing
eect on circut
5.0mm
12 0mm
/A1
8/A2-
9/AL
0/AL
Power supply
(AC, DC)
-
LOAD
-
Alarm out
NPN open collector
output)
1/L1
2/T1
R S T
3/L2
4/T2
5/L3
6/T3
Load
Rapid
fuse
Power supply
(AC, DC)
/A1
nput
ircuit
-
8/A2-
9/AL
LOAD
Over eaing eect on
0/AL-
circut
Alarm out (NPN open colector output)
Specications
Input
Rated input voltage range Allowable input voltage range Max. input current 25mA 15mA 25mA Pick-up voltage Min. 4VDC Drop-out voltage Max. 1VDC
Zero cross
Turn-on
turn-on
time
Random turn-on Max. 1ms
Turn-off time
©==-=-=1_=-=====t====±;;=
Output
Rated load voltage range 24-240VACrmsᜠ (50/60Hz) 48-480VACrmsᜠ (50/60Hz) Allowable load voltage range Rated load
Resistive load
current
(AC-51)
I
Min. load current 0.15Arms 0 2Arms 0.5Arms 0.5Arms
Max. 1 cycle surge current (60Hz) Max. non-repetitive surge
2
current (I
t, t=8 3ms)
'
Peak voltage (non-repetitive)
~
Leakage current (Ta=25℃)
Output on voltage drop
[Vpk] (max. load current)
Static off state dv/dt 500V/
1: AC-51 is utilization category at EC60947-4-3.
(DJ
Alarm output (temperature overheat)
Rated input voltage range
Loadvoltage Loadcurrent
Turn-off time Max. 20ms Max. 40ms Max. 40ms
General specications
i
Dielectric strength (Vrms)
'
Insulation resistance Over 100MΩ (at 500VDC megger) (input-output, input/output-case)
L__
Indicator Input
I
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Vibration
1
Malfunction 0 5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
L__
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
~
Shock
I
-
Malfunction 100m/s² (approx. 30G) in each X, Y, Z direction for 3 times
L__
Ambient temp.
Environ­ment
L
Ambient humi. 45 to 85%RH, storage: 45 to 85%RH
c__
I
Input terminal connection, alarm
output terminal connection
L__
Output terminal connection
<--------
Input terminal xed torque 0.75 to 0.95N m
-
Output terminal xed torque 1 6 to 2.2N m
L___
Approval
L___
1
Weight
1: The weight includes packaging. The weight in parenthesis is for unit only.
Environment resistance is rated at no freezing or condensation.
For wiring the terminal, round terminal must be used.
Dimensions
Detachable heatsink type
4-Ø5.2
4-5.2
Alarm indicator
(red)
Integrated heatsink (Rated load current 50A)
Alarm indicator (red)
Integrated heatsink (Rated load current 75A)
Alarm indicator (red)
4-30VDC
4-32VDC
Max. 0.5 cycle of load
source + 1ms
Max. 0.5 cycle of load
source + 1ms
I I I
24-264VACrmsᜠ (50/60Hz) 48-528VACrmsᜠ (50/60Hz)
15Arms 30Arms 50Arms 75Arms 15Arms 30Arms 40Arms 50Arms 75Arms
1
250A 400A 1000A 300A 500A 1000A
2
340A
s 1000A2s 4000A2s 350A2s 1000A2s 4000A2s
I
I
l
600V
Max. 10mArms (240VACᜠ/60Hz) Max. 10mArms (480VACᜠ/60Hz)
Max. 1.6V
I
I
4-30VDC
Max. 30VDC Max. 100mA Max. 50mA Max. 50mA
.
'
.
-30 to 80℃ (in case of the rated input voltage 90-240VACЖ: -30 to 70℃), storage: -30 to 100 ( The rated load current capacity is different depending on ambient temperature.
Min. 1×0.5mm2 (1×AWG20), max. 1×1.5mm2 (1×AWG16) or 2×1.5mm2 (2×AWG16)
Min. 1×1.5mm
ᜢ ᜧ
.
.
109
97 92
4-R2.6
144 132
144 132
24-240VAC
: 2500VAC 50/60Hz 1 min (input-output, input/output-case)
24-240VAC 48-480VACᜠ rated load current 15A/30A/40A/50A/75A
: 4000VAC 50/60Hz 1 min (input-output, input/output-case)
Refer to
Use wires compliant with load current capacity to connect to the terminal.
Detachable heatsink type: Approx. 365g (approx. 275g)
Integrated heatsink type
- Rated load current 15A/30A/40A: Approx. 896g (approx. 686g)
- Rated load current 50A: Approx. 1508g (approx. 1268g)
- Rated load current 75A: Approx. 2354g (approx. 2064g)
rated load current 15A/30A
rated load current 50A/75A,
indicator: green LED, alarm indicator: red LED
SSR Derating Curve'.)
r.i
2
(1×AWG16), max. 1×16mm2 (1×AWG6) or 2×6mm2 (2×AWG10)
Input indicator
(green)
32
75.5
47.6
Input indicator (green)
2-2
2-4.5
Input indicator (green)
2-2
2-4.5
24VACrmsᜠ (50/60Hz) 90-240VACrmsᜠ (50/60Hz)
19-26.4VACrmsᜠ (50/60Hz) 85-264VACrmsᜠ (50/60Hz)
Min. 19VACrms
Max. 4VACrms Max. 1 5 cycle of load
source + 1ms
- -
Max. 1 5 cycle of load
source + 1ms
I
I
I
I
I
I
24VACrmsᜠ (50/60Hz) 90-240VACrmsᜠ (50/60Hz)
Max. 30VDC
Integrated heatsink (Rated load current 15A/30A/40A)
2-Ø4.5
32.2
2-Ø4.5
80
65
2-Ø4.5
130
115
I
1200V (Zero cross turn-on),
1000V (Random turn-on)
I
I
130
103
3.5 3.5
Alarm indicator
4.5 (red)
3.5
132.2
132.2
Min. 85VACrms
Max. 10VACrms Max. 1.5 cycle of load
source + 1ms
Max. 1.5 cycle of load
source + 1ms
I
I I
7
I
Max. 30VDC
I
Input indicator
(green)
76
90
100
4.5
3.5
Bolts for grounding must be grounded.
High Temperature Caution
&.
While supplying power to the load or right after turning off the power of
the load, do not touch the body and
heat sink. Failure to follow this instruction may result in a burn due to the high temperature.
00
SR(H)2/ SR(H)3-
I
SR(H)3-
14 (R)
SR(H)2/
-
SR(H)3-
SR(H)2/ SR(H)3-
-
i
-
-
-
-
-
-
-
-
-
SR(H)2/ SR(H)3-
-
g
Load capacity Cooling fan type Size (mm)
30A/40A
50A/75A
I
112.7
32.2
DIN rail must be grounded.
SSR Derating Curve
15A 30A 40A 50A 75A
With heatsink
15
10
12
SR(H)2/
24
42
44
Load current[A]
Without heatsink
4
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink
15
□□
□□
□□
□□
10
Load current[A]
Without heatsink
4
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink
15
10
Load current[A]
Without heatsink
4
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink
15
10
Load current[A]
Without heatsink
4
1.5
0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
Specications of cooling fan
AC Fan DC Fan 1 25 44.0 AC Fan DC Fan 1 80 63.5
I I I I
Cooling fan mounting hole
0
. .
Rated load current 30A/40A
Panel cut-out
Detachable heatsink type
Detachable heatsink type screw tightening torque for mounting : 2.5N.m to 3N.m
Integrated heatsink
(Rated load current 50A)
※
Integrated heatsink type screw tightening torque for mounting : 1.35N.m
WheninatallingmultipleSSRs,pleasekeepspacebetweenSSRsforheatradiation.
WheninstallingSSRshorizontally(inputpartandoutputpartonthesameheight), pleasesupplylessthan50%oftheratedloadcurrent.
97 92
With heatsink+Fan
30
20
With heatsink
15 14
Load current[A]
10
Without heatsink
5 4
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink+Fan
30
20
With heatsink
15
Load current[A]
10
Without heatsink
5
1.5
0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink+Fan
30
20
With heatsink
15 14
Load current[A]
10
Without heatsink
5 4
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink+Fan
30
20
With heatsink
15
Load current[A]
10
Without heatsink
7 5
1.5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
Rated air ow
m3/min CFM
80×80
92×92
71.5
132 132
DIN ra l bracket
0 68 24.0
1.13 40.0
Rated load current 50A/75A
4-Ø3.2
8-M5
32
71.5
Integrated heatsink (Rated load current 15A/30A/40A)
47.6
7 7
Integrated heatsink
(Rated load current 75A)
4-M4 4-M4
65
:r
60
With heatsink+Fan
50
40
With heatsink
Load current[A]
With heatsink+Fan
40
With heatsink
19
Load current[A]
15
Without heatsink
7 5
0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
60
With heatsink+Fan
40
With heatsink
Load current[A]
19 15
Without heatsink
7 5
0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
1
(unit: mm)
4-Ø3.4
82.5
103
4-M4
The heatsink of the curves is dedicated for the SRH2/SRH3.
Install SR2/SR3 Series on the metal plate (min. 130mm×120mm).
Since effectiveness of the heat rediation is decreased when multiple SSRs are installed closely,
A
please supply less than 50% of the rated load current.
Above SSR derating curves obtained approval from the UL certication authority.
1: The cooling fan should be over the rated air ow value.
Autonics does not provide or sell a cooling fan. (Please buy a cooling fan separately.)
Cautions during Use
00
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
4-30VDC, 24VAC
2. supply device.
3. Attach a heat sink or install the unit in the well ventilated place.
To attach the heat sink, use Thermal Grease as below or that of equal specication.
Thermal Grease: GE TOSH BA (YG6111), KANTO-KASEI (FLO L G-600), SH NETSU (G746)
4. Ground to the heat sink, panel, or D N rail.
Failure to follow this instruction may result in electric shock.
5. While supplying power to the load or right after turning off the power of the load, do not touch the
82.5
body and heat sink. Failure to follow this instruction may result in a burn due to the high temperature.
6. In order to protect the product from the short-circuit current of the load, use rapid fuse of which I2t is
under the 1/2 of SSR I2t. When short-circuited, replace the fuse to those of same specication with the used rapid fuse.
7. Install dummy resistance in parallel with the load, to keep the sum of current owing in the load and
dummy resistance being over SSR minimum load current.
8. When using random turn-on model for phase control, install noise lter between the load and the
power of the load.
23 16
Without heatsink
9 5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
1.5
60
With heatsink+Fan
50
40
With heatsink
Load current[A]
23 16
Without heatsink
9 5
0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
1.5
signal input should be insulated and limited voltage/current or Class 2, SELV power
With heatsink+Fan
75
50
With heatsink
Load current[A]
34
16
Without heatsink
10
1.5
5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
With heatsink+Fan
75
50
With heatsink
34
Load current[A]
16 10
Without heatsink
1.5
5 0
0 10 20 30 40 50 60 70 80 90
Ambient temperature[℃]
1.5
1.5
9. Do not use near the equipment which generates strong magnetic force or high frequency noise.
10. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
①
Altitude max. 2,000m
90
~
②
Pollution degree 2
③ ④InstallationcategoryIII
Major Products
00
Photoelectric Sensors Temperature Controllers
Fiber Optic Sensors
Door Sensors SSRs/Power Controllers
Door Side Sensors Counters
Area Sensors Timers
Proximity Sensors Panel Meters
Pressure Sensors Tachometers/Pulse(Rate) Meters
Rotary Encoders Display Units
115
Connectors/Sockets Sensor Controllers
Switching Mode Power Supplies
Control Switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper Motors/Drivers/Motion Controllers
Graphic/Logic Panels
Field Network Devices
Laser Marking System(Fiber, Co₂, Nd:YAG)
Laser Welding/Cutting System
Temperature/Humidity Transducers
DRW161053AC
Loading...