SR1-4420-N 90-240VACᜠ Zero cross turn-on
SR1-1425-N
SR1-1425R-N Random turn-on
4-30VDCᜡ
25A
Zero cross turn-on
SR1-4425-N 90-240VACᜠ Zero cross turn-on
SR1-1430-N
SR1-1430R-N Random turn-on
SR1-4430-N 90-240VACᜠ Zero cross turn-on
SR1-1440-N
SR1-1440R-N Random turn-on
4-30VDCᜡ
4-30VDCᜡ
30A
40A
48-480VAC
ᜠ
Zero cross turn-on
Zero cross turn-on
SR1-4440-N 90-240VACᜠ Zero cross turn-on
SR1-1450-N
SR1-1450R-N Random turn-on
4-30VDCᜡ
50A
Zero cross turn-on
SR1-4450-N 90-240VACᜠ Zero cross turn-on
SR1-1475-N
SR1-1475R-N Random turn-on
4-30VDCᜡ
75A
Zero cross turn-on
SR1-4475-N 90-240VACᜠ Zero cross turn-on
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
Specications
Input
Rated input voltage range4-30VDC
ᜡ
Allowable input voltage range 4-32VDCᜡ 85-264VACrmsᜠ (50/60Hz)
Max. input current18mA18mArms (240VACrmsᜠ)
Pick-up voltageMin. 4VDCᜡ Min. 85VACrmsᜠ
Drop-out voltageMax. 1VDCᜡ Max. 10VACrmsᜠ
Turn-on
time
Zero cross turn-on Max. 0.5 cycle of load source + 1msMax. 2 cycle of load source + 1ms
I
Random turn-onMax. 1ms
I
Turn-o timeMax. 0.5 cycle of load source + 1msMax. 2 cycle of load source + 1ms
Output
Rated load voltage range24-240VACrmsᜠ (50/60Hz)
Allowable load voltage range 24-264VACrmsᜠ (50/60Hz)
Rated load
current
Min. load current0.15Arms0.2Arms0.2Arms0.5Arms
Max. 1 cycle surge current
(60Hz)
Max. non-repetitive surge
current (I
Peak voltage (non-repetitive) 600V
Leakage current (Ta=25℃)Max. 10mArms (240VACᜠ/60Hz)
Output on voltage drop [Vpk]
(max. load current)
Static o state dv/dt500V/
Rated load voltage range48-480VACrmsᜠ (50/60Hz)
Allowable load voltage range 48-528VACrmsᜠ (50/60Hz)
Rated load
current
Min. load current0.5Arms0.5Arms0.5Arms0.5Arms
Max. 1 cycle surge current
(60Hz)
Max. non-repetitive surge
current (I
Peak voltage
(non-repetitive)
Leakage current (Ta=25℃)Max. 10mArms (480VACᜠ/60Hz)
Output on voltage drop [Vpk]
(max. load current)
Static o state dv/dt500V/
Dielectric strength (Vrms)2500VAC 50/60Hz 1 min (input-output, input/output-case)
Insulation resistanceOver 100MΩ (at 500VDC megger) (input-output, input/output-case)
IndicatorInput indicator: green LED
Vibration
Shock
Environment
Input terminal connectionMin. 1×0.5mm
Output terminal connection
Input terminal xed torque0.75 to 0.95N.m
Output terminal xed torque1.6 to 2.2N.m
Approval
※
1
Weight
※
1: The weight includes packaging. The weight in parenthesis is for unit only.
※
Environment resistance is rated at no freezing or condensation.
※
For wiring the terminal, round terminal must be used.
Mechanical0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction100m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Ambient temp.
Ambient humi. 45 to 85%RH, storage: 45 to 85%RH
-30 to 80℃ (in case of the rated input voltage 90-240VACᜠ: -20 to 70℃), storage: -30 to 100℃
( The rated load current capacity is dierent depending on ambient temperature. Refer to SSR Derating Curve' )
2
(1×AWG20), max. 1×1.5mm2 (1×AWG16) or 2×1.5mm2 (2×AWG16)
Min. 1×1.5mm
※
Use wires compliant with load current capacity to connect to he terminal.
ᜢ ᜧ
Approx. 111g (approx. 73g)
2
(1×AWG16), max. 1×16mm2 (1×AWG6) or 2×6mm2 (2×AWG10)
Dimensions
(unit: mm)
Panel cut-out
2-M4
Input indicator
(green)
※
When installing multiple SSRs, please keep space between SSRs for heat radiation.
When installing SSRs horizontally (input part and output part on the same height), please supply less than 50% of the rated load current.
44
4.5
Ø4.5
47.5
28.3
47.5
58
※
Screw tightening torque for mounting: 1.8 to 2.5N.m
Connections
4/A2-1/L1
-
Power
supply
(AC, DC)
~
+
[~ [
InputOutput
SSR module
SR1 Series
:1
Load
:i
Rapid fuse
2/T13/A1+
Load
power source
(AC)
K-8
※
Use terminals of size specied below.
Terminal typeInputOutput
a Min. 3.5mm Min. 5.0mm
a
b
<Round>
b Max. 7.0mm Max. 12.0mm
I I I
Autonics
Single-Phase, Detachable Heatsink Type SSR
SSR Derating Curve
※
Be sure that the ambient temperature and the derating curve is dierent by the rated input voltage.
: Rated input voltage 4-30VDC (SR1-1-N)
: Rated input voltage 90-240VAC (SR1-4-N)
SR1-1210/4210-N SR1-1410/1410R/4410-N
20
With heatsink 2.5℃/W
10
7
Without heatsink
Load current [A]Load current [A]Load current [A]Load current [A]Load current [A]
5
1.5
0
0
10 20 25 30 40 50 60 70 80 90
Ambient temperature [℃]
(Q)
SR1-1215/4215-N
20
With heatsink 2.5℃/W
15
10
Without heatsink
7
5
1.5
0
0
10 20 25 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1220/4220-N
With heatsink 2.0℃/W
20
10
Without heatsink
7
1.5
5
0
0
'
-"-
10 20 25 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1225/4225-N
30
With heatsink 0.9℃/W
25
20
10
Without heatsink
7
5
1.5
0
0
10 20 25 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1230/4230-N
I I
With heatsink 0.9℃/W
30
20
15
Without heatsink
6
1.5
0
0
10 20 25 30 40 50 60 70 80 90
I I I
_!_
----------
Ambient temperature [℃]
_'_""!_
□□□
□□□
~
20
With heatsink 2.5℃/W
10
Without heatsink
Load current [A]Load current [A]Load current [A]Load current [A]Load current [A]
6
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
(Q)
SR1-1415/1415R/4415-N
20
With heatsink 2.5℃/W
15
10
Without heatsink
6
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1420/1420R/4420-N
With heatsink 2.0℃/W
20
10
8
6
Without heatsink
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1425/1425R/4425-N
30
With heatsink 2.0℃/W
25
20
10
8
6
Without heatsink
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1430/1430R/4430-N
I I I I I
With heatsink 0.9℃/W
30
20
15
Without heatsink
6
1.5
0
0
10 2030 40 50 60 70 80 90
----------
Ambient temperature [℃]
--'-
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
-~
(X)
Field Network
Devices
Autonics
K-9
SR1 Series
SSR Derating Curve
※
Be sure that the ambient temperature and the derating curve is dierent by the rated input voltage.
: Rated input voltage 4-30VDC (SR1-1-N)
: Rated input voltage 90-240VAC (SR1-4-N)
SR1-1240/4240-N
40
I I I I I
With heatsink 0.9℃/W
□□□
□□□
SR1-1440/1440R/4440-N
With heatsink 0.9℃/W
40
20
Load current [A]Load current [A]
15
Without heatsink
6
1.5
0
0
10 20 25 30 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1250/1450/1450R-N
SR1-4250/4450-N
60
With heatsink 0.9℃/W
50
40
20
15
Without heatsink
7
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
20
Load current [A]Load current [A]
1.5
15
6
0
Without heatsink
0
10 2030 40 50 60 70 80 90
Ambient temperature [℃]
SR1-1275/1475/1475R-N
SR1-4275/4475-N
With heatsink 0.5℃/W
75
50
25
16
Without heatsink
7
1.5
0
0
10 20 30 40 50 60 70 80 90
Ambient temperature [℃]
Since eectiveness of the heat radiation is decreased when multiple SSRs are installed closely, please supply less than
50% of the rated load current.
※
Above SSR derating curves obtained approval from the UL certication authority.
Proper Usage
Cautions during use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 4-30VDC signal input should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Attach a heat sink or install the unit in the well ventilated place.
To attach the heat sink, use Thermal Grease as below or that of equal specication.
※
Thermal Grease: GE TOSHIBA (YG6111), KANTO-KASEI (FLOIL G-600), SHINETSU (G746)
4. Ground to the heat sink, panel, or DIN rail. Failure to follow this instruction may result in electric shock.
5. While supplying power to the load or right after turning o the power of the load, do not touch the body and heat sink.
Failure to follow this instruction may result in a burn due to the high temperature.
6. In order to protect the product from the short-circuit current of the load, use rapid fuse of which I
SSR I2t. When short-circuited, replace the fuse to those of same specication with the used rapid fuse.
7. Install dummy resistance in parallel with the load, to keep the sum of current owing in the load and dummy resistance
being over SSR minimum load current.
8. When using random turn-on model for phase control, install noise lter between the load and the power of the load.
9. Do not use near the equipment which generates strong magnetic force or high frequency noise.
10. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
④ Installation category III
2
t is under the 1/2 of
K-10
Autonics