Features

Combined•functions•of•paper•recorder•and•paperless• recorder
Enables•to•set•parameters•with•USB,•RS485,•Ethernet• communication
•High•legibility•and•setting•convenient•by•graph•LCD•
•High•speed•sampling•of•25ms,•high•speed•record•of• 240mm/H•functions•
•100mm•paper•record•(selectable•6•kinds•of•record• color)•
Supports•inner•memory•and•USB•memory•data• backup•(storage)
Supports•several•input•up•to•12•channels•with•slot• type•input•cards
Enables•to•select•several•option•cards•with•slot•type• output•cards
•Space•saving•for•installation•with•compact•design• (rear•length:•168mm)
•Supports•total•27•kinds•of•input•types
Enables•to•order•several•type•input•cards•(weight,• voltage,•current,•frequency,•potential•meter,•etc)•
Please read “Caution for your safety” in operation manual before using this unit.

Manual

••For•more•information•and•instructions,•refer•to•the•user•manual•and•the•user•manual•for•communication.• Visit•our•web•site•(www.autonics.com)•to•download•the•manuals.
••The•user•manual•includes•product•specications,•functions,•and•operations.
••The•user•manual•for•communication•includes•information•about•Modbus•RTU•protocol,•Modbus•TCP•protocol,•and•Modbus• mapping•table.•

Integrated device management program(DAQMaster)

••DAQMaster•is•the•integrated•device•management•program•to•set•parameters•and•manage•monitoring•data.
••Visit•our•website•(www.autonics.com)•to•download•user•manual•and•integrated•device•management•program.
<•DAQMaster•screen•><•Computer•specication•for•using•software•>
Item Minimum•requirements
System
Operating•system Microsoft•Windows•98/NT/XP/Vista/7 Memory 256MB•or•more Hard•disk More•than•1GB•of•free•hard•disk•space VGA 1024×768•or•higher•resolution•display Others RS-232•serial•port(9-pin),•USB•port
IBM•PC•compatible•computer•with•Intel•Pentium•
•or•above
A-2
100mm Hybrid Recorder

Ordering information

Ordering information for recorder model
KRN100 12 0 0 0 0 0 0 S
Item Description
•Item
•Input•channel
•Digital•input
•Alarm•transistor•output
•Alarm•relay•output
•Transmitter•power•output
•Communication•output
•Power•voltage
•Case
KRN100 New•100mm•Paper•Type•Recorder
02 2-channel(KRN-UI2×1EA)
04 4-channel(KRN-UI2×2EA)
06 6-channel(KRN-UI2×3EA)
08 8-channel(KRN-UI2×4EA)
10 10-channel(KRN-UI2×5EA)
12 12-channel(KRN-UI2×6EA)
0 None
1 6EA(KRN-DI6×1EA)
2 12EA(KRN-DI6×2EA)
0 None
1 6EA(KRN-AT6×1EA)
2 12EA(KRN-AT6×2EA)
0 None
1 4EA(KRN-AR4×1EA)
2 8EA(KRN-AR4×2EA)
3 12EA(KRN-AR4×3EA)
0 None
1 3EA(KRN-24V3×1EA)
2 6EA(KRN-24V3×2EA)
3 9EA(KRN-24V3×3EA)
4 12EA(KRN-24V3×4EA)
0 None
1 RS485/Ethernet/USB(KRN-COM×1EA)
0 100-240VAC,•50/60Hz
S Standard•panel•mounting•type
A. Recorder
B.•Indicator
C.•Converter
D.•Controller
E.•Thyristor•
•••••unit
F.•Pressure•
••••transmitter
G.•Temp.•
•••••transmitter
H.•Accessories
KRN100
KRN50
Ordering information for input/output card
Type Model Function•and•number•of•channels Max.•mountable•cards Slot•number
Universal•input•card KRN-UI2 Universal•input•2-channel 6EA 1•to•6
Digital•input•card KRN-DI6 Digital•input•6-channel• 2EA
Alarm•output•card
Transmitter•power•output•card
Communication•output•card• KRN-COM
•1.•The•digital•input•card,•alarm•output•card,•transmitter•power•output•card•are•connectable•up•to•4EA•as•mixed.
KRN-AR4 Alarm•relay•output•4-channel• 3EA
KRN-AT6 Alarm•transistor•output•6-channel 2EA
KRN-24V3
Transmitter 24VDC•power•output•3-channel
RS485•+•USB•+•Ethernet•communication• output
4EA
1EA C
7•to•10
1
Example of ordering
To•use•universal•input•10-channel,•digital•input•4-channel,•alarm•relay•output•5-channel,•and•RS485•communication•output,•it•is• ordered•as•KRN100-10102-01-0S•and•the•connected•I/O•card•is•as•below.•
•••KRN100(recorder):•1EA
•••KRN-UI2(universal•input•card):•5EA•(universal•input•card•1EA•is•2-channel•and•5EA×2-channel•=•10-channel.)
•••KRN-DI6(digital•input•card):•1EA
•••KRN-AR4(alarm•relay•output•card):•2EA
•••KRN-COM(Communication•output•card):•1EA
A-3
KRN100
Series

Connections

Rear side of KRN100 standard model
This•gure•is•the•rear•side•of•KRN100-04000-00-0S.
SOURCE 100-240VAC 50/60Hz,•55VA
Slot Description
1•to•6 Connects•universal•input•card(KRN-UI2).•
7•to•10
C Connects•communication•output•card(KRN-COM).
Connects•digital•input•card(KRN-DI6),•alarm•output•card(KRN­AR4,•KRN-AT6),•transmitter•power•output•card(KRN-24V3).•
I/O card
Universal input card [KRN-UI2] Digital input card [KRN-DI6]
UI2
-
+
-
+
Each•channel•is•isolated•and•dielectric•strength•is•500V.
Alarm output card [KRN-AR4(relay output)] Alarm output card [KRN-AT6(transistor output)]
Inner Inner
AR4
250VAC•3A•1a
DI6
AT6
A-4
AL1,2,3•and•AL4,5,6••are•isolated.
Transmitter power output card [KRN-24V3] Communication output card [KRN-COM]
24V3
24VDC•30mA
24VDC•30mA
24VDC•30mA
24V•output•of•3EA•is•isolated•individually.
COM
100mm Hybrid Recorder
Specications
Series
Power•voltage 100-240VAC•50/60Hz
Allowable•voltage•range 85•to•110%•of•rated•voltage
Power•consumption Max.•55VA
LCD•type STN•Graphic•LCD
Screen
Resolution 320×120Pixel
Adjusting•brightness 4-level(OFF/Min/Standard/Max)
Backlight White•LED,•2-level(Temp/Always)
Input•channels 2•/•4•/•6•/•8•/•10•/•12-channel(2-channel/card)-Expandable
Universal•input
1
Sampling•cycle
Recording•period•in•graph•mode
Recording•speed•accuracy F.S.•±0.5%
Storage•cycle 1•to•3600sec.•(storage•interval•time•to•inner•log•le•is•1•sec.)•
Inner•memory 512MB
USB•memory User•purchased,•recognizes•max.•32GB,•enables•to•use•cable•up•to•1.5m
Dielectric•voltage
Vibration•strength• (for•convey•and•storage)•and• operating•vibration•
Insulated•resistance Min.•20MΩ(at•500VDC•megger)
Noise ±2kV•the•square•wave•noise•(pulse•width•1)•by•the•noise•simulator••
Time•accuracy Within•±2min./year•(enables•to•use•up•to•2100•year)
Mech­anism
Ink•cartridge Enables•to•normal•print•with•going•and•returning•printing•max.•5•times•within•7•days•after•opening•the•unit•
Ink•dry•time Max.•15•minutes
Protection IP40(for•front•panel)
Recording•paper 113mm×9m
Environ­ment
Ambient•temperature
Ambient•humidity 35•to•85%•RH,•storage•:•35•to•85%•RH
Approval
Unit•weight Approx.•1.7•to•2.0kg•
•1.•For•more•information•of•universal•input,•please•refer•to•I/O•cardof•the•A-6•page.
•2.•When•using•this•unit•in•high•humidity,•it•may•cause•paper•jam.•Please•do•not•use•this•unit•in•high•humidity.•
•Environment•resistance•is•rated•at•no•freezing•or•condensation.
KRN100
Temperature•sensor(RTD,•thermocouple),•analog
1•to•4-channel•:•25ms/125ms/250ms,•5•to•12-channel•:•125ms/250ms (inner•sampling•cycle•is•operation•unit•time•for•average•movement•lter•and•alarm•output•function.) Max.•sampling•cycle•for•TC-R,•U,•S,•T•sensor•is•50ms.
10,•20,•40,•60,•120,•240mm/H
250VAC•50/60Hz•for•1min.•(power•terminal•and•case)• •Excepts•USB•Device•and•Ethernet
Vibration•strength•:•10•to•60Hz•4.9m/s2•(each•of•X,•Y,•Z•axes•for•1•hour)• Operating•vibration•:•10•to•60Hz•1m/s2•(each•of•X,•Y,•Z•axes•for•10•min.)•
0•to•50,•storage•:•-20•to•60•(without•ink•cartridge)
A. Recorder
B.•Indicator
C.•Converter
D.•Controller
E.•Thyristor•
•••••unit
F.•Pressure•
••••transmitter
G.•Temp.•
•••••transmitter
H.•Accessories
KRN100
KRN50

Dimensions

144
● Panel cut-out
18.6
Min.175
+1.0•
••0
138
Min.175•
138
+1.0•
••0
168
137
•This•rear•side•dimension•is•with• installed•I/O•cards•to•every•slot.
•Use•a•steel•plate•which•is•2•to•8mm•thickness.
137
(unit:•mm)
A-5
KRN100
Series
I/O card
Type Model I/O•specications Descriptions
RTD JPt100Ω,•DPt100Ω,•DPt50Ω,•Cu100Ω,Cu50Ω(supply•current••420)
Thermocouple B,•C(W5),•E,•G,•J,•K,•L,•L(Russia),•N,•P,•R,•S,•T,•U
1
Analog
RTD
Thermocouple
2
Analog
Capacity 250VAC,•3A,•30VDC•3A,•1•Form•A•(resistance•load)
Life
RS485
EtherNet IEEE802.3(U),•10/100•BASE-T(Modbus•TCP)
USB•Device
4
Universal•input• card
Digital•input•card• KRN-DI6•
Alarm•output•card
Transmitter•power• output•card
Communication• output•card
KRN-UI2
KRN-AR4•
KRN-AT6 Alarm•transistor•output NPN•Open•Collector,•12-24VDC/30mA•Max.
KRN-24V3• Transmitter•power•output
KRN-COM Com.•output
3
Input•type
Input•impedance
Display• accuracy
Resolution 16Bit
Non-contact•input ON:•Max.•1V•of•residual•voltage,•OFF:•Max.•0.1mA•of•leakage•current
Contact•input ON:•Max.•1kΩ,•OFF:•Min.•100kΩ,•Outow•current•for•short:•Approx.•4mA
Alarm relay output
Voltage:•±60mV•±200mV•±2V,•1-5V,•±5V,•-1V-10V Current:•0.00-20.00mA,•4.00-20.00mA
Voltage(V):•Min.•150kΩ RTD,•Thermocouple,•Voltage(mV):•Min.•2MΩ Current:•51Ω
Warm-up•time:•Min.•30•min. Room•temperature•(25±5):•±0.1%F.S•±1digit Out•of•room•temperature•range:•±0.2%F.S•±1digit For•RTD,•500•to•800•is•±0.5%±1digit•of•PV•value,• For•Thermocouple,•below•-100•is•±0.3%F.S.±1digit.
Mechanical:•Min.•50,000,000•operations Electrical:•Min.•100,000•operations•(3A•250VAC,•3A•30VDC)
24±2VDC,•,•total•3-channel,•max.•30mA•per•1-channel built-in•over-current•protection•circuit
Modbus•RTU
Recommended•to•use•shield•cable•over•AWG24
USB•V2.0•Full•Speed(Device•Control)
1.To•change•input•specication,•you•must•turn•OFF•the•power•of•KRN100,•remove•universal•input•cards,•set•inner•jumper•pins•(please• refer•to•‘ I/O•card’•of•the•A-4•page)•and•re-connect•it.•
•2.•Exception•range•for•measuring•accuracy•by•each•sensor(accuracy•after•30min•warm-up•time)••
••••••••· R,S,C,G:•0≤T≤100±4.0,•
••••••••· B:•No•regulation•accuracy•below•400
••••••••· U,T:-200≤T≤-100±3.0,•-100≤T≤400±2.0,•
••••••••· Cu50:•-200≤T≤200±1.0
••••••••· DPt50:•-200≤T≤600±1.5
•3.•RS485,•Ethernet•communication•output•are•not•available•at•the•same•time.•••
•4.The•front•USB•device•is•only•for•data•backup•and•rear•USB•device•is•available•only•for•parameter•setting.
•It•is•recommended•to•use•shield•cable•to•decrease•noise•when•sensor•input•cable•is•longer.
If connecting or disconnecting input/output card when power is ON, it may cause malfunction.
To connect or disconnect input/output card, you must turn OFF the power.