Autonics GP-S070 Series Catalog Page

GP-S070 Series
Basic Type 7 inch Color LCD Graphic Panel
Features
● Adopts 7 inch wide TFT LCD for realizing True Color with 16,777,216 colors
● Analog touch method
: Free tag arrangement
● Data logger function
: Supports data gathering and backup of controller
● Supports variable image library
● Enables to monitor multi stations and multi channels at
the same time
● Supports several interface
: Supports USB Host/Device to high speed download and
manage les
: Easy to connect various external devices with RS232C 2 ports
and RS232C/RS422 multi-communication port
● Supports several fonts
: Supports window true type and several bitmap fonts (selectable)
● Device monitoring function
: Enables to monitor/control variable of connected control through communication port
● Easy S/W upgrade available on website (1) GP rmware le (2) GP Editor (drawing program) (3) Additional protocol
(4) Language and font, etc
● Connects printer/barcode reader: Enables to print out alarm history, to read barcode
Please read “Safety Considerations” in the instruction manual before using.
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
Manual
00
● GP Editor user manual
It describes how to write screen data, and is about related usage of GP-S070 HMI function.
● GP/LP user manual for communication
It describes connection for external devices such as PLC.
● GP-S070 user manual
It describes general information of the installation and usage of GP-S070 and system contents.
Ordering Information
00
Model Item Series Monitor size Display unit Color Power supply Interface
GP-S070-T9D6
GP-S070-T9D7
f------------11
Graphic panel
S series 7 inch
I I I I I
TFT Color LCD
16,777,216
color
24VDC
RS232C, RS422, USB HOST, USB DEVICE, Ethernet
RS232C (2), USB HOST,
f--------------1
USB DEVICE, Ethernet
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
Autonics
V-47
GP-S070 Series
Specifications
Model GP-S070-T9D6 GP-S070-T9D7 Power supply 24VDC
Allowable voltage range 90 to 110% of power supply Power consump ion Max. 7 2W
LCD type 7 inch TFT Color LCD Resolution 800×480 dots Display area 152.4×91.44mm Color 16,777,216 color LCD view angle Within each 60°/ 45°/ 60°/ 60°of top/bottom/left/right
Backlight White LED Brightness Adjustable by software
Display performance
Language
Text
Graphic drawing memory 16MB Number of user screen 500 pages
performance
Graphic drawing
Touch switch Analog touch
Serial interface
USB interface Each of USB HOST, USB Device (Version 1.1)
Ethernet interface IEEE802.3 (U), 10/100Base-T Real-time controller RTC embedded
Battery life cycle Approx. 3 years at 25 Insulation resistance Over 100MΩ (at 500VDC megger) Ground 3rd grounding (max. 100Ω) Noise immunity ± 0.5kV the square wave noise (pulse width: 1) by the noise simulator
Withstanding voltage 500VAC 50/60Hz for 1 min
Vibra ion
Shock
Environ
-ment Protec ion structure IP65 (front panel, IEC standard)
Accessory Fixing bracket: 4, battery (included)
Approval
Weight
1: Supported language can be added.
Environment resistance is rated at no freezing or condensa ion.
1
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min Mechanical 300m/s² (approx. 30G) in each X, Y Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temperature 0 to 50, storage: -20 to 60 Ambient humidity 35 to 85% RH, storage: 35 to 85%RH
2
English, Korean
• Vector font • 6×8, 8×8 ASCII character, high denition numbers
8×16 ASCII characters, 16×16 character by each country (1 to 8 times bigger for width, 0 5 to 5 imes bigger for height)
Asynchronous me hod: each port of RS232C, RS422 Each port of RS232C, RS422 Two ports of RS232C
, Z direction for 3 times
CE~
Approx. 680g (approx. 500g)
※2: The weight includes packaging. The weight in parenthesis is for unit only.
Function
Figure display Line, rectangle, circle, text, bitmap
Numeral display Displays the designated device as numerical value. (decimal, hexadecimal, octal, binary, real number)
ASCII display Displays the designated device value as ASCII character. Time display Displays current time or date. Alarm history Registers alarm history. Alarm list Displays generated (not backed up) alarm.
Comment display Displays the designated comment as device status or value. Lamp Displays lamp as device status. Part display Displays the designated parts as device status and value. Line graph Displays several device values with a graph of broken line.
Tags
Trend graph Displays change of device value for time with a graph of broken line.
Bar graph Displays a device value with a bar graph. Sta is ic graph Displays a ratio of several device values wi h pie graph. Panel meter Displays a device value as panel meter. Touch key Screen is switched, word/bit device values are set when it touched. Numeral input Congures user input value in device.
ASCII input Congures user input ASCII code value in device.
System information function Monitors/Controls GP operation from PLC.
Recipe function Reads/Writes several PLC device collectively.
Security function Only acceptable user can observe/operate important data. Barcode read func ion Connects barcode reader, read barcode. Floating alarm function Warning message is oated when alarm is generated.
Time operation Specic bit device is ON/OFF for designated day and time. Overlap window Available to form dynamically overlapping another base screen on the base one. Observe status function Changes PLC device status/value of PLC when trigger is generated.
I
I
, Z direction for 1 hour
V-48
Autonics
Basic Type 7 inch Color Graphic Panel
Dimensions
,
bt
.____(
-------.,ih--------------
-------r-------
Unit Description
185
194
(unit: mm)
● Panel cut-out
Min. 240
+1.1
186
0
1
~,
6.5 28.5
I
I
I
I
I
134
125
,
I
I
145.8
0
+1.0
126
Panel thickness : max. 4mm
● Fixing bracket
15
Max. 4-R3
Min. 175
M4 BOLT
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
(L) Power Controllers
(M) Counters
(N) Timers
(O)
Digital
Panel Meters
LCD Screen
Fixing bracket
(2 slots is in upper side, 2 slot is in lower side)
● Ethernet Port: For connecting LAN cable and hub, use direct cable, and for connecting PC directly, use cross cable.
● USB Device: When setting USB Device mode to HID mode in serial setting, it is for uploading/downloading GP Editor
project. When setting to Storage mode, it is for transferring/coping data between PC and GP-S070 with
recognition as a storage device by PC. For details, please refer to 'GP-S070 user manual'.
● USB Host: It is for transferring/coping data between USB storage device and GP-S070 and upgrading firmware.
● RS232C, RS422 ports: For more information, refer to ' Serial Interface' of GP/LP Common Features.
Power terminal
block
RS422
RS232C
or
-A
Mounting slot
for bracket
RS232C
or
RS232C
-B
Ethernet
USB
Device
USB Host
(P)
Indicators
(Q) Converters
(R) Digital
Display Units
(S) Sensor Controllers
(T)
Switching Mode Power
Supplies
(U)
Recorders
(V) HMIs
(W) Panel PC
(X)
Field Network
Devices
Autonics
V-49
GP-S070 Series
Installation
1. Set GP-S070 in panel.
2. Set fixing brackets in 4 slots (2 slots is in upper side, 2 slots is in lower side).
Upper side
Mounting slot
for bracket
Lower side
3. Tighten fixing bracket with M4 Screw driver and tightening torque is 0.3 to 0.5N·m.
M4 Screw driver
Serial Interface
● All devices are connectable with GP-S070 including PC, PLC, serial printer, barcode reader and dedicated connectors
can be connected with both RS232C and RS422 ports.
● Use the dedicated communication cable for the each connected device. (Refer to the "GP/LP Communication Cables")
● For the method of wiring external devices like PLC, refer to "GP/LP communication manual".
Port NO. Pin RS232C
RS422
r;-----,
5
4
3
2
1
~
D-Sub 9-pin
Male
5
ro---
0
4
0
0
3
0
0
2
0
0
1
~
D-Sub 9-pin
Female
9
8
7
6
6
7
8
9
1 Not used 2 RXD 3 TXD 4 DTR 5 SG 6 DSR
7 Not used 8 Not used 9 Not used
1 TXD+ 2 RXD+ 3 Not used
4 Not used
5 SG 6 TXD-
7 RXD- 8 Not used 9 Not used
V-50
Autonics
Basic Type 7 inch Color Graphic Panel
Cable (sold separately)
Serial connection cables which connect GP/LP with PLC or other external devices are sold separately.
Refer to "GP/LP Communication Cables".
SENSORS
-
Power Wiring
+
● For power supply, use the wire of which cross section is at least 0.75mm² and
use the wire of which cross section is at least 1.25mm² for grounding.
● Use round terminal with at least 3mm of internal diameter and less than 6mm of
external diameter.
● Do not apply power before power line connection.
● Check power polarity.
● Tighten the terminal screw with 0.5 to 0.8N·m torque.
● Ground resistance should be less than 100Ω and ground it separately.
+
24VDC
-
Battery Replacement
Please contact out distributor to replace battery. It may cause an explosion or a fire when improper battery is used.
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
4. Operate the product after supplying power to the product, input/output equipment, and load.
If operate product before supplying power, it may result in output error or malfunction.
5. Keep away from high voltage lines or power lines to prevent inductive noise. Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Make a required space around the unit for radiation of heat, and do not block ventilation openings.
7. Do not push the touch panel with a hard and sharp object or push the panel with excessive force.
It may result in fire or malfunction.
8. When skin is smeared with liquid crystal from the broken LCD, rinse with running water for over 15 minutes. If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor.
9. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
F.G.
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
(L) Power Controllers
(M) Counters
(N) Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q) Converters
Autonics
V-51
(R) Digital
Display Units
(S) Sensor Controllers
(T)
Switching Mode Power
Supplies
(U)
Recorders
(V) HMIs
(W) Panel PC
(X)
Field Network
Devices
Loading...