● Adopts 7 inch wide TFT LCD for realizing
True Color with 16,777,216 colors
● Analog touch method
: Free tag arrangement
● Data logger function
: Supports data gathering and backup of controller
● Supports variable image library
● Enables to monitor multi stations and multi channels at
the same time
● Supports several interface
: Supports USB Host/Device to high speed download and
manage les
: Easy to connect various external devices with RS232C 2 ports
and RS232C/RS422 multi-communication port
● Supports several fonts
: Supports window true type and several bitmap fonts (selectable)
● Device monitoring function
: Enables to monitor/control variable of connected control through communication port
● Easy S/W upgrade available on website
(1) GP rmware le
(2) GP Editor (drawing program)
(3) Additional protocol
(4) Language and font, etc
● Connects printer/barcode reader: Enables to print out alarm history, to read barcode
Please read “Safety Considerations”
in the instruction manual before using.
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
Manual
00
● GP Editor user manual
It describes how to write screen data, and is about related usage of GP-S070 HMI function.
● GP/LP user manual for communication
It describes connection for external devices such as PLC.
● GP-S070 user manual
It describes general information of the installation and usage of GP-S070 and system contents.
Ordering Information
00
ModelItemSeriesMonitor size Display unit ColorPower supply Interface
GP-S070-T9D6
GP-S070-T9D7
f------------11
Graphic
panel
S series7 inch
I I I I I
TFT Color
LCD
16,777,216
color
24VDCᜡ
RS232C, RS422, USB HOST,
USB DEVICE, Ethernet
RS232C (2), USB HOST,
f--------------1
USB DEVICE, Ethernet
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
Autonics
V-47
GP-S070 Series
Specifications
ModelGP-S070-T9D6 GP-S070-T9D7
Power supply24VDCᜡ
Allowable voltage range90 to 110% of power supply
Power consump ionMax. 7 2W
LCD type7 inch TFT Color LCD
Resolution800×480 dots
Display area 152.4×91.44mm
Color16,777,216 color
LCD view angleWithin each 60°/ 45°/ 60°/ 60°of top/bottom/left/right
BacklightWhite LED
BrightnessAdjustable by software
Display performance
Language
Text
Graphic drawing memory 16MB
Number of user screen 500 pages
performance
Graphic drawing
Touch switchAnalog touch
Serial interface
USB interfaceEach of USB HOST, USB Device (Version 1.1)
Battery life cycleApprox. 3 years at 25℃
Insulation resistanceOver 100MΩ (at 500VDC megger)
Ground3rd grounding (max. 100Ω)
Noise immunity± 0.5kV the square wave noise (pulse width: 1㎲) by the noise simulator
Withstanding voltage500VAC 50/60Hz for 1 min
Vibra ion
Shock
Environ
-ment
Protec ion structureIP65 (front panel, IEC standard)
AccessoryFixing bracket: 4, battery (included)
Approval
Weight
※
1: Supported language can be added.
※
Environment resistance is rated at no freezing or condensa ion.
※1
Mechanical0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y
Malfunction0.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical300m/s² (approx. 30G) in each X, Y
Malfunction100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temperature 0 to 50℃, storage: -20 to 60℃
Ambient humidity35 to 85% RH, storage: 35 to 85%RH
※2
English, Korean
• Vector font • 6×8, 8×8 ASCII character, high denition numbers
•
8×16 ASCII characters, 16×16 character by each country (1 to 8 times bigger for width, 0 5 to 5 imes bigger for height)
Asynchronous me hod: each port of RS232C, RS422
Each port of RS232C, RS422Two ports of RS232C
, Z direction for 3 times
CE~
Approx. 680g (approx. 500g)
※2: The weight includes packaging. The weight in parenthesis is for unit only.
Numeral displayDisplays the designated device as numerical value. (decimal, hexadecimal, octal, binary, real number)
ASCII displayDisplays the designated device value as ASCII character.
Time displayDisplays current time or date.
Alarm historyRegisters alarm history.
Alarm listDisplays generated (not backed up) alarm.
Comment displayDisplays the designated comment as device status or value.
LampDisplays lamp as device status.
Part displayDisplays the designated parts as device status and value.
Line graphDisplays several device values with a graph of broken line.
Tags
Trend graphDisplays change of device value for time with a graph of broken line.
Bar graphDisplays a device value with a bar graph.
Sta is ic graphDisplays a ratio of several device values wi h pie graph.
Panel meterDisplays a device value as panel meter.Touch keyScreen is switched, word/bit device values are set when it touched.
Numeral inputCongures user input value in device.
ASCII inputCongures user input ASCII code value in device.
System information functionMonitors/Controls GP operation from PLC.
Recipe functionReads/Writes several PLC device collectively.
Security functionOnly acceptable user can observe/operate important data.
Barcode read func ionConnects barcode reader, read barcode.
Floating alarm functionWarning message is oated when alarm is generated.
Time operationSpecic bit device is ON/OFF for designated day and time.
Overlap windowAvailable to form dynamically overlapping another base screen on the base one.
Observe status functionChanges PLC device status/value of PLC when trigger is generated.
I
I
, Z direction for 1 hour
V-48
Autonics
Basic Type 7 inch Color Graphic Panel
Dimensions
,
bt
.____(
-------.,ih--------------
-------r-------
Unit Description
185
194
(unit: mm)
● Panel cut-out
Min. 240
+1.1
186
0
1
~,
6.528.5
I
I
I
I
I
134
125
,
I
I
145.8
0
+1.0
126
※
Panel thickness
: max. 4mm
● Fixing bracket
15
Max. 4-R3
Min. 175
M4 BOLT
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
LCD Screen
Fixing bracket
(2 slots is in upper side, 2 slot is in lower side)
● Ethernet Port: For connecting LAN cable and hub, use direct cable, and for connecting PC directly, use cross cable.
● USB Device: When setting USB Device mode to HID mode in serial setting, it is for uploading/downloading GP Editor
project. When setting to Storage mode, it is for transferring/coping data between PC and GP-S070 with
recognition as a storage device by PC.
For details, please refer to 'GP-S070 user manual'.
● USB Host: It is for transferring/coping data between USB storage device and GP-S070 and upgrading firmware.
● RS232C, RS422 ports: For more information, refer to ' Serial Interface' of GP/LP Common Features.
Power terminal
block
RS422
RS232C
or
-A
Mounting slot
for bracket
RS232C
or
RS232C
-B
Ethernet
USB
Device
USB
Host
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
Autonics
V-49
GP-S070 Series
Installation
1. Set GP-S070 in panel.
2. Set fixing brackets in 4 slots (2 slots is in upper side, 2 slots is in lower side).
Upper side
Mounting slot
for bracket
Lower side
3. Tighten fixing bracket with M4 Screw driver and tightening torque is 0.3 to 0.5N·m.
M4 Screw driver
Serial Interface
● All devices are connectable with GP-S070 including PC, PLC, serial printer, barcode reader and dedicated connectors
can be connected with both RS232C and RS422 ports.
● Use the dedicated communication cable for the each connected device.
(Refer to the "GP/LP Communication Cables")
● For the method of wiring external devices like PLC, refer to "GP/LP communication manual".
PortNO. Pin
RS232C
RS422
r;-----,
5
•
4
•
•
3
•
•
2
•
•
1
~
D-Sub 9-pin
Male
5
ro---
0
4
0
0
3
0
0
2
0
0
1
~
D-Sub 9-pin
Female
9
8
7
6
6
7
8
9
1Not used
2RXD
3TXD
4DTR
5SG
6DSR
7Not used
8Not used
9Not used
1TXD+
2RXD+
3Not used
4Not used
5SG
6TXD-
7RXD-
8Not used
9Not used
V-50
Autonics
Basic Type 7 inch Color Graphic Panel
Cable (sold separately)
Serial connection cables which connect GP/LP with PLC or other external devices are sold separately.
Refer to "GP/LP Communication Cables".
SENSORS
-
Power Wiring
+
● For power supply, use the wire of which cross section is at least 0.75mm² and
use the wire of which cross section is at least 1.25mm² for grounding.
● Use round terminal with at least 3mm of internal diameter and less than 6mm of
external diameter.
● Do not apply power before power line connection.
● Check power polarity.
● Tighten the terminal screw with 0.5 to 0.8N·m torque.
● Ground resistance should be less than 100Ω and ground it separately.
+
24VDC
-
Battery Replacement
Please contact out distributor to replace battery.
It may cause an explosion or a fire when improper battery is used.
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
4. Operate the product after supplying power to the product, input/output equipment, and load.
If operate product before supplying power, it may result in output error or malfunction.
5. Keep away from high voltage lines or power lines to prevent inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Make a required space around the unit for radiation of heat, and do not block ventilation openings.
7. Do not push the touch panel with a hard and sharp object or push the panel with excessive force.
It may result in fire or malfunction.
8. When skin is smeared with liquid crystal from the broken LCD, rinse with running water for over 15 minutes.
If it gets into the eyes, rinse eyes with running water for over 15 minutes and contact a doctor.
9. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specifications')
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
F.G.
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
Autonics
V-51
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.