● Selectable voltage input (PNP) method or
no-voltage input (NPN) method
● Decimal point setting (xed decimal point of display)
● Wide range of power supply
: 100-240VAC 50/60Hz, 24VAC 50/60Hz, 24-48VDC universal
● Memory protection for 10 years (using non-volatile semiconductor)
● Selectable Up/Down for counting value
● Built-in Microprocessor
Please read “Safety Considerations”
in the instruction manual before using.
~I
&=---
~
Model
Display digit4-digit5-digit
Character size (W×H)3.8×7.6mm4×8mm
Power supply24VACᜠ 50/60Hz, 24-48VDCᜡ100-240VACᜠ 50/60Hz
Permissible voltage range90 to 110% of rated voltage
Power consumption
Max. counting speed for COUNT IN Selectable 1cps/30cps/2kcps/5kcps (DIP switch)
Return timeMax. 500ms
Min. signal widthRESET: approx. 20ms
Input method
One-shot output time0.05 to 5 sec
Control
output
Relay
life cycle
Insulation resistanceOver 100MΩ (at 500VDC megger)
External power supplyMax. 12VDCᜡ ±10% 50mA
Memory retentionApprox. 10 years (non-volatile memory)
Dielectric strength2,000VAC 50/60Hz for 1 min (between all terminals and case)
Noise
AC voltage±2kV the square wave noise (pulse width 1㎲) by noise simulator
AC/DC voltage±500V the square wave noise (pulse width 1㎲) by noise simulator
Mechanical0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y
Malfunction0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical300m/s
Malfunction100m/s
Ambient temp.-10 to 55℃, storage: -25 to 65
Ambient humi.35 to 85%RH, storage: 35 to 85%RH
● Solid-state input (standard sensor: PNP output type sensor)
Sensor
(PNP output)
※
COUNT IN, RESET input part
Brown
Black
※
Blue
+12V
Inner circuit
10.8kΩ
0V
SensorCounter
Brown
Black
※
Blue
(PNP open collector output)
Counter
+12V
Inner circuit
10.8kΩ
0V
No-voltage input (NPN)
● Solid-state input (standard sensor: NPN output type sensor)
Sensor
(NPN output)
※
COUNT IN, RESET input part
Brown
Black
※
Blue
Counter
+12V
5.4kΩ
Inner circuit
0V
Sensor
(NPN open collector output)
Brown
Black
Blue
Counter
5.4kΩ
※
+12V
Inner circuit
0V
● Contact input
Counter
※
※
Counting speed
: Set as 1 or 30cps
+12V
Inner circuit
10.8kΩ
0V
● Contact input
Counter
※
※
Counting speed
: Set as 1 or 30cps
5.4kΩ
Inner circuit
0V
+12V
Input & output connections
PR18-5DN
● Total value of load capacity and current
consump ion should not be exceed
current capacity (max. 12VDC 50mA)
M-90
Brown
Black
Blue
12VDC
COUNT IN
GND
3
2
18
SOURCE
54
6
7
+
-
Autonics
● Please select proper capacity of
load not to exceed contact capacity.
Load
Contact capacity: max. 250VAC 3A
Contact type: 1a
8 Pin Plug Type Counter
Dimensions
48
□
(Q)
Bracket
36
44.9
12 3
63.814
(unit: mm)
SENSORS
10.5
CONTROLLERS
MOTION DEVICES
SOFTWARE
■
(Q)
Panel cut-out
45
□
Min. 65
+0.6
45
□
0
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
30.545
7
Min. 65
48.6
□
55
56
(Q)
Socket (sold separately)
PG-08PS-08(N)
38
31
21
16
41
Ø25
Error Display and Output Operation
Error DisplayError descriptionTroubleshoo ing
ERR0
※
When error occurs, the output turns OFF.
※
Indicator model does not have error display function.
Setting value is 0.Change the setting value anything but 0.
(P)
Indicators
(Q)
Converters
50
40
70
4
2-Ø4 5
23 5
35
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
19
14
Autonics
M-91
FS Series
DIP Switch Setting
ON
122335 6
Input logic (COUNT IN, RESET input)
•
SW1Function
ON
OFF
1
OFF
Up/Down mode
•
SW1Function
OFF
2
OFF
Memory backup
SW1Function
6
※
How to change settings
Power OFF → change settings → power ON → press
NPN (no-voltage input)
ON
PNP (voltage input)
ON
Down mode
ON
Up mode
ON
No memory backup
OFF
ON
Memory backup
OFF
Output operation mode
Memory backup
Max. counting speed
N.C (not used)
※
1
3 2 1 6 5 4 3 2 1
ON
OFF
SW2
※
1: Indicator model (FS5-I4) does not have no. 1, 2, 3 DIP
switch of SW2 for output operation mode setting.
Max. counting speed
•
SW1Function
RESET
key or input signal (min. 20ms)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SW1
5 4
[l]
5 4
[;[;]
5 4
~
5 4
[!]
Up/Down mode
Input logic (NPN/PNP)
Factory default
1cps
30cps
2kcps
5kcps
Dot for Decimal Point
RESET
3 sec
RUN mode
RESET
DP
RESET
----
3 sec
Setting mode
Set decimal point
RESET
by front
※
In run mode, hold the
setting mode [DP].
※
In setting mode, hold the
saves the setting and returns to RUN mode.
※
If there is no
mode, it returns to RUN mode.
RESET
RESET
key input for 60 sec when entering setting
c:=i
Counting Operation for Indicator (FS5-I4)
● Up mode● Down mode
+Max. display value
□
vldv
0
※
- display is only for F, K, Q, S output operation mode and it cannot be set.
M-92
n
Autonics
+Max. display value
-Max. display value
RESETRESET
key for over 3 sec, and it enters
RESET
key for over 3 sec, and it
c:=i
n n
0
~
8 Pin Plug Type Counter
Output Operation Mode
Output mode
(SW2)
F
3 2 1
ON
OFF
N
3 2 1
ON
OFF
C
3 2 1
ON
OFF
R
3 2 1
ON
OFF
K
3 2 1
ON
OFF
P
3 2 1
ON
OFF
Q
3 2 1
ON
OFF
S
3 2 1
ON
OFF
※
Set one-shot output time by front TIME volume switch.
SW1SW1
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
2
ON
Up mode
OFF
n n n
--~-~-:--
;Li_J
0
~;/
I I I I
H H
n n n
I I I I I
--'::7-~~--
~
0
~
I I I I • I I I
H H H H
q
--;;21212-i;
0
•
■
-- --
1 I I I
I I I I
0
---
. . -
0
• •
q
'
--TZ[]2:J2
' ' '
' ' '
0
'
0
0
H H
.
;,r
■
--
._
One-shot output (0.05 to 5 sec)
2
ON
Down modeOperation
OFF
RESET
Setting
0
Output
n n n
RESET
Setting
-:STN-Ct:-
0
Output
q
RESET
Setting
-~-
0
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
RESET
Setting
Output
0
0
0
0
0
•
■
Self-holding output
n-
After count-up, counting display value
increases or decreases until reset
signal input is applied and self-holding
output is maintained.
After count-up, counting display value
and self-holding output are maintained
until reset signal input is applied.
When count-up, coun ing display value
is reset and it counts simultaneously.
■
After count-up, counting display value
is reset after one-shot output time and
it counts simultaneously.
After count-up, counting display value
increases or decreases until reset
signal input is applied.
After count-up, counting display value
is maintained while output is ON.
Counting value is internally reset and
it counts simultaneously.
After count-up, counting display value
increases or decreases during
one-shot output time.
Output maintains ON when counting
display value is larger or equal than
setting value.
Proper Usage
● Follow instructions in ‘Proper Usage’. Otherwise, it may cause unexpected accidents.
● 24-48VDC, 24VAC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
● Use the product, 0.1 sec after supplying power.
● When supplying or turning o the power, use a switch or etc. to avoid chattering.
● Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
● In case of contact input, set count speed to low speed mode (1cps or 30cps) to operate.
If set to high speed mode (2kcps or 5kcps), counting error occurs due to chattering.
● Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line lter or varistor at power line and shielded wire at input
signal line.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
● This product may be used in the following environments.
Indoors (in the environment condition rated in ‘Specications’)
①
Altitude max. 2,000m
②
Pollution degree 2
③
Installation category II
④
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices
Autonics
M-93
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.