![](/html/45/459e/459e4eaf32effc7d7e143019642c03d33a0228f469178377b1756e425e42db04/bg1.png)
DRW171499AA
Autonics
INDUCTIVE PROXIMITY SENSOR
CYLINDRICAL TYPE DC 3WIRE
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※
※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic
loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety
equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration,
impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
Ordering Information
00
Output
V
Load
Load
Brown
Black
Blue
Cable type
+V
0V
+V
0V
Load
No mark
V
S
DN
DN2
DP
DP2
Number Standard sensing distance(Unit: mm)
Number Diameter of head(Unit: mm)
No mark
S
L
No mark
W
R Cylindrical type
P Inductive proximity sensor
Sensing target
Load
(Brown-Black)
Output voltage
(Black-Blue)
Operation indicator
(RED LED)
Sensing target
Load
(Black-Blue)
Output voltage
(Black-Blue)
Operation indicator
(RED LED)
+V
2 1
3
0V
Blue
Standard cable
Oil resistant cable
Option
NPN N.O.(Normally Open)
NPN N.C.(Normally Closed)
PNP N.O.(Normally Open)
PNP N.C (Normally Closed)
Standard
Short body
Long body
DC 3 wire, Cable type
DC 3 wire, Cable connector type
Normally Open Normally Closed
Presence
_O__
Nothing
Operation
_O__
Return
H
L
ON
_O__
OFF
Normally Open Normally Closed
Presence
_O__
Nothing
Operation
_O__
Return
H
_O__
L
ON
_O__
OFF
Brown
4
Black
Load
+V
0V
2
1
4
3
Presence
Nothing
Operation
Return
OFF
Presence
Nothing
Operation
Return
OFF
Brown
Black
Blue
ON
ON
H
L
H
L
+V
Load
0V
:
P R W L
Body size
Connection
Shape
Item
Control Output Diagram & Load Operation
00
NPN output
Main circuit
PNP output
Main circuit
Dimension
Ω
10k
Ω
10k
518
DN
Sensing distance
Brown
Black
Blue
Brown
Black
Blue
Connections
Cable type Cable connector type
NPN PNP NPN PNP
The above specifications are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
※
Brown
Black
Blue
Load
+V
0V
Specications
00
PR08-1 5DN
I
Model
Sensing distance 1 5mm 2mm 2mm 4mm 5mm 8mm 10mm 15mm
Hysteresis Max. 10% of sensing distance
'
Standard sensing
'
target
Setting distance 0 to 1 05mm 0 to 1.4mm 0 to 2 8mm 0 to 3.5mm 0 to 5.6mm 0 to 7mm 0 to 10.5mm
'
Power supply
(Operating voltage)
Current consumption
Response
frequency
j
Residual voltage Max. 2.0V Max. 1.5V
Affection by Temp. Within ±10℃ max. of sensing distance at 20℃ in temperature range of -25 to 70℃(PR
Control output Max. 200mA
_J
Insulation resistance
'
Dielectric strength 1,500VAC 50/60Hz for 1minute
'
Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours
'
Shock 500m/s
'
Indicator Operation indicator(Red LED)
'
Environ-
, l
ment
Protection circuit Surge protection, Reverse polarity proteciton, Overload & short circuit protection
'
Protection P67(IEC Standards)
'
'
2
J
※
Cable
'
'
Materials
Approval
Weight
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
※
sensing target, 1/2 of the sensing distance for the distance.
2:
※
Do not pull the Ø3.5mm cable with a tensile strength of 25N, the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm
cable with a tensile strength of 50N or over.
It may result in fire due to the broken wire. When extending wire, use AWG22 cable or over within 200m.
3: The weight with packaging and the weight in parentheses is only unit weight.
※
※
Environment resistance is rated at no freezing or condensation.
Dimensions
00
Type
Flush
I
PR08-1 5DP
PR08-1 5DN2
PR08-1 5DP2
PRL08-1 5DN
PRL08-1 5DP
PRL08-1 5DN2
PRL08-1 5DP2
PRW08-1 5DN
PRW08-1 5DP
PRW08-1.5DN2
PRW08-1.5DP2
PRW08-1.5DN-V
PRW08-1.5DP-V
PRWL08-1.5DN
PRWL08-1.5DP
PRWL08-1.5DN2
PRWL08-1.5DP2
8×8×1mm (Iron) 12×12×1mm (Iron)
12-24VDC
(10-30VDCᜡ)
Max. 10mA
1 5kHz 1kHz 1 5kHz 500Hz 500Hz 350Hz 400Hz 200Hz
※1
Min. 50MΩ(at 500VDC megger)
Ambient temp.
Ambient humi.
PR, PRL
PRW,
PRWL
-25 to 70℃, Storage: -30 to 80
35 to 95%RH, Storage: 35 to 95%RH
3.5mm, 3-wire, 2m
Ø
(AWG24, Core diameter:
0 08mm, Number of cores: 40,
Insulator diameter: Ø1mm)
4mm, 3-wire, 300mm, M12 Connector
Ø
Case/Nut: Nikel plated Brass, Washer: Nikel plated Iron, Sensing surface: PBT,
Standard cable(Black): Polyvinyl chloride(PVC), Oil resistant cable(Gray): Oil resistant Polyvinyl chloride(PVC)
(€
PR: Approx. 64g(Approx. 52g)
PRL: Approx. 66g(Approx. 54g)
※3
PRW: Approx. 44g(Approx. 32g)
PRWL: Approx. 46g(Approx. 34g)
Cable type Cable connector type
I
'
M8, M12, M18, M30 M8, M12, M18, M30
~
Nonush
E
~
Type A B C D E F G H J
(-
M8
M12
Flush
M18
'
M30
M8
~
Non-ush
I
M12
M18
M30
PR08-2DN
I
PR08-2DP
PR08-2DN2
PR08-2DP2
PRL08-2DN
PRL08-2DP
PRL08-2DN2
PRL08-2DP2
PRW08-2DN
PRW08-2DP
PRW08-2DN2
PRW08-2DP2
PRW08-2DN-V
PRW08-2DP-V
PRWL08-2DN
PRWL08-2DP
PRWL08-2DN2
PRWL08-2DP2
_j
ᜡ
J
2
(approx. 50G) X, Y, Z directions for 3 times
B
C
A
D
j_L
B
C
A
D
j_L
J
PR M8×1 30 30 4
PRL M8×1 40 40 4
PRW M8×1 30 30 4
PRWL M8×1 40 40 4
PR M12×1 46 31 5 4
PRS M12×1 39 24.5 4
PRW M12×1 46 31.5 4
PRL M12×1 74.5 60 4
'
PR M18×1 47.5 29.5 4
PRL M18×1 80.5 62.5 4
'
PRW M18×1 47.5 29.5 4
'
PRWL M18×1 80.5 62.5 4
PR M30×1 5 58 38 5
PRL M30×1 5 80 60 5
PRW M30×1 5 58 38 5
PRWL M30×1 5 80 60 5
PR M8×1 30 30 4 4 3 5 13 15 2,000
PRL M8×1 40 40 4 4 3 5 13 15 2,000
PRW M8×1 30 30 4 4 4 13 15 300
PRWL M8×1 40 40 4 4 4 13 15 300
PR M12×1 46 24.5 4 7 4 17 21 2,000
PRS M12×1 39 17.5 4 7 4 17 21 2,000
'
PRW M12×1 46 24.5 4 7 4 17 21 300
'
PRL M12×1 58.5 37 4 7 4 17 21 2 000
'
PR M18×1 47 19 4 10 5 24 29
PRL M18×1 80.5 62.5 4 10 5 24 29 2,000
PRW M18×1 47 19 4 10 5 24 29 300
PRWL M18×1 80.5 62.5 4 10 5 24 29 300
PR M30×1 5 58 28 5 10 5 35 42 2,000
PRL M30×1 5 80 50 5 10 5 35 42 2,000
PRW M30×1 5 58 28 5 10 5 35 42 300
PRWL M30×1 5 80 50 5 10 5 35 42 300
I
PR12-2DN
PR12-2DP
PR12-2DN2
PR12-2DP2
PRS12-2DN
PRS12-2DP
PRS12-2DN2
PRS12-2DP2
PRW12-2DN
PRW12-2DP
PRW12-2DN2
PRW12-2DP2
PRL12-2DN
PRL12-2DP
J
J
_j
℃
4mm, 3-wire, 2m
Ø
(AWG22, Core diameter: 0.08mm, Number of cores: 60, Insulator diameter: Ø1 25mm)
l
PR: Approx. 84g(Approx. 72g)
PRS: Approx. 82g(Approx. 70g)
PRW: Approx. 54g(Approx. 42g)
PRL: Approx. 88g(Approx. 76g)
J
J
F
J
F
PR12-4DN
PR12-4DP
PR12-4DN2
PR12-4DP2
PRS12-4DN
PRS12-4DP
PRS12-4DN2
PRS12-4DP2
PRW12-4DN
PRW12-4DP
PRW12-4DN2
PRW12-4DP2
PRL12-4DN
PRL12-4DP
_J
J
B
C
~n,I
- - -
D
_J.J._
B
C
E
~
J
J
I
PR18-5DN
PR18-5DP
PR18-5DN2
PR18-5DP2
PRL18-5DN
PRL18-5DP
PRL18-5DN2
PRL18-5DP2
PRW18-5DN
PRW18-5DP
PRW18-5DN2
PRW18-5DP2
PRWL18-5DN
PRWL18-5DP
PRWL18-5DN2
PRWL18-5DP2
18×18×1mm
(Iron)
J
_j
J
5mm, 3-wire, 2m
Ø
J
5mm, 3-wire, 300mm, M12 Connector
Ø
J
PR: Approx. 122g(Approx. 110g)
PRL: Approx. 142g(Approx. 130g)
PRW: Approx. 70g(Approx. 58g)
PRWL: Approx. 90g(Approx. 78g)
J
J
j
F
t
A
J
i
-
t
F
AD
J
J J
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I I
PR18-8DN
PR18-8DP
PR18-8DN2
PR18-8DP2
PRL18-8DN
PRL18-8DP
PRL18-8DN2
PRL18-8DP2
PRW18-8DN
PRW18-8DP
PRW18-8DN2
PRW18-8DP2
PRWL18-8DN
PRWL18-8DP
PRWL18-8DN2
PRWL18-8DP2
25×25×1mm
(Iron)
J
_J _J _J
J
□
""1DDll
-=L
3 5 13 15 2,000
3 5 13 15 2 000
4 13 15 300
4 13 15 300
4 17 21 2 000
4 17 21 2,000
4 17 21 300
4 17 21 2,000
5 24 29 2,000
5 24 29 2,000
5 24 29 300
5 24 29 300
5 35 42 2 000
5 35 42 2,000
5 35 42 300
5 35 42 300
PR30-10DN
PR30-10DP
PR30-10DN2
PR30-10DP2
PRL30-10DN
PRL30-10DP
PRL30-10DN2
PRL30-10DP2
PRW30-10DN
PRW30-10DP
PRW30-10DN2
PRW30-10DP2
PRW30-10DN-V
PRW30-10DP-V
PRWL30-10DN
PRWL30-10DP
PRWL30-10DN2
PRWL30-10DP2
30×30×1mm
(Iron)
J
J J
08 Series: Max. ±20%)
PR: Approx. 207g(Approx. 170g)
PRL: Approx. 247g(Approx. 210g)
PRW: Approx. 134g(Approx. 122g)
PRWL: Approx 195g(Approx. 158g)
J
Nut & Washer
I
M12×1
M12×1
J
J
PR30-15DN
PR30-15DP
PR30-15DN2
PR30-15DP2
PRL30-15DN
PRL30-15DP
PRL30-15DN2
PRL30-15DP2
PRW30-15DN
PRW30-15DP
PRW30-15DN2
PRW30-15DP2
PRW30-15DN-V
PRW30-15DP-V
PRWL30-15DN
PRWL30-15DP
PRWL30-15DN2
PRWL30-15DP2
45×45×1mm
(Iron)
J
H
G
I
-
-
-
-
-
-
(Unit: mm)
ijJ
_J
-
2,000
-
Mutual-interference & Inuence by Surrounding Metals
Mutual-interference
◎
When several proximity sensors are mounted closely, malfunction of sensor may be caused due to mutual interference. Therefore, be
sure to provide a minimum distance between the two sensors with referring to the chart below.
□
ød
PR 18-5D
□
□ □
PRW 18-5D
[Table 1]
Model
I
PR08
Series
PR12
Series
PR18
Series
PR30
Series
Washer
●
Parallel
~
B
PR 18-8D
□ □
PRW 18-8D
Target
Sn
Sa
(b)
Front Rear
Strength
'
Flush 7mm
I
Non-ush 5mm
Flush 13mm
Non-ush 7mm
'
Flush -
Non-ush -
Flush 26mm
Non-ush 12mm
J l l
Size Torque Torque
-
Mounting
bracket
m
n
ℓ
PR 30-10D
PRW 30-10D
I
3 92N m 8.82N m
6 37N m 11.76N m
14.7N m
49N m 78.4N m
l
l
DRW171499AA
PR 30-15D
□ □
PRW 30-15D
●
Face to Face
A
Influence by surrounding metals
◎
When sensors are mounted on metallic panel, it is required to protect the sensors from being affected by any metallic object except target.
Therefore, be sure to provide a minimum distance as below chart.
(a)
ℓ
□
Target
Moving
direction
Sn:
Sensing distance
{
Sa:
Setting distance
(70% of Sn)
ℓ
Model
PR 08-1.5D PR 08-2D PR 12-2D PR 12-4D
□
tem
A 9 12 12 24 30 48 60 90
B 16 24 24 36 36 54 60 90
ℓ 0 8 0 11 0 14 0 15
ød 8 24 12 36 18 54 30 90
m 4.5 6 6 12 15 24 30 45
n 12 24 18 36 27 54 45 90
Setting Distance
00
●
Sensing distance can be changed by the shape, size or material of the target.
Therefore please check the sensing distance like (a), then pass the target within range of setting distance(Sa).
●
Setting distance(Sa) = Sensing distance(Sn) × 70%
E g.)PR30-10DN(See ordering information)
Setting distance(Sa) = 10mm × 0.7 = 7mm
Installation and Tightening Torque
When tightening the nut, use the provided washer as [Figure 1].
When installing the product, the tightening torque of the nut varies
according to the distance from the fore-end.
The front part of the product is from the fore-end to the dimension on
the below table, and the rear part is from the tip of the nut to the end
of the product. [Figure 2]
In case the nut is placed in the front part of the product, apply
tightening torque for front part.
[Table 1] the allowable tightening torque table is for inserting the
washer as [Figure 3].
[Figure 1] [Figure 2] [Figure 3]
'~
Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. 12-24VDC power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
3. Use the product, after 0.8 sec of supplying power.
4. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.).
In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor
to remove surge.
5. This unit may be used in the following environments.
① Indoors (in the environment condition rated in 'Specications') ② Altitude max. 2,000m
③ Pollution degree 2 ④ Installation category II
Major Products
00
Photoelectric Sensors Temperature Controllers
■
Fiber Optic Sensors Temperature/Humidity Transducers
■
Door Sensors SSRs/Power Controllers
■
Door Side Sensors Counters
■
Area Sensors Timers
■
Proximity Sensors Panel Meters
■
Pressure Sensors Tachometer/Pulse (Rate) Meters
■
Rotary Encoders Display Units
■
Connector/Sockets Sensor Controllers
■
Switching Mode Power Supplies
■
Control Switches/Lamps/Buzzers
■
I/O Terminal Blocks & Cables
■
Stepper Motors/Drivers/Motion Controllers
■
Graphic/Logic Panels
■
Field Network Devices
■
Laser Marking System (Fiber, CO₂, Nd: YAG)
■
Laser Welding/Cutting System
■
□ □
□ □ □
Moving
direction
Front Rear
■
■
■
■
■
■
■
■
■
Nut tip
Fore-end
(Unit: mm)
□
□