Autonics CYLINDRICAL TYPE AC 2WIRE Instruction Manual

DRW171498AA
Autonics
INDUCTIVE PROXIMITY SENSOR
CYLINDRICAL TYPE AC 2WIRE
I N S T R U C T I O N M A N U A L
Thank you for choosing our Autonics product.
Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards.
※ ※
symbol represents caution due to special circumstances in which hazards may occur.
Warning Failure to follow these instructions may result in serious injury or death.
Caution
Failure to follow these instructions may result in personal injury or product damage.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in re, personal injury, or economic loss.
2. Do not disassemble or modify the unit.
Failure to follow this instruction may result in electric shock or re.
3. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in electric shock or re.
4. Check 'Connections' before wiring.
Failure to follow this instruction may result in re.
Caution
1. Use the unit within the rated specications.
Failure to follow this instruction may result in re or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in electric shock or re.
3. Do not use the unit in the place where ammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in re or explosion.
4. Do not supply power without load.
Failure to follow this instruction may result in re or product damage.
Ordering Information
Body size
Connec ion
18
Dimension
- ~
Brown
Blue
AL O
Sensing distance
Brown
Blue
Load
Load
Output
Power supply
------=~~~==
Load
100-240VAC
~
50/60Hz
~
O Normally open
C Normally closed
A 100-240VAC
Number Standard sensing distance(Unit: mm)
Number Diameter of head(Unit: mm)
No mark Standard type
L Long body
No mark Cable type
W Cable connector type
~~~
R Cylindrical type
P Inductive proximity sensor
[
Load
Load
Presence
[
Nothing
Operation Return
ON OFF
[
~
~
Sensing
target
Load
Operation
Indicator
(Red LED)
______!_~
1
Brown
423
Brown
N.O. N.C.
~
In AC switching type, 2 and 3, 1 and 4 are connected inside of he
connector cable.
~
P R 5W
c_____
Shape
Item
Control Output Diagram & Load Operation
Main circuit
~--=
Connections
Cable type Cable connector type
The load can be connected to either wire.
The above specications are subject to change and some models may be discontinued without notice.
※
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).
※
Specications Connection of Power Supply
PR12-2AO PR12-2AC PRW12-2AO
Model
Sensing distance 2mm 4mm 5mm 8mm 10mm 15mm Hysteresis Max. 10% of sensing distance Standard sensing target 12×12×1mm(Iron) 18×18×1mm(Iron) 25×25×1mm(Iron) 30×30×1mm(Iron) 45×45×1mm(Iron) Setting distance 0 to 1.4mm 0 to 2.8mm 0 to 3 5mm 0 to 5 6mm 0 to 7mm 0 to 10.5mm Power supply
(Operating voltage) Leakage current Max. 2.5mA Response frequency Residual voltage Max. 10V Affection by Temp. Max. ±10% of sensing distance at +20℃ within temperature range of -25 to +70 Control output 5 to 150mA 5 to 200mA Insulation resistance Min. 50MΩ(at 500VDC megger) Dielectric strength 2,500VAC 50/60Hz for 1minute Vibration 1mm amplitude at frequency of 10 to 55Hz in each of X, Y, Z directions for 2 hours Shock 500m/s²(50G) X, Y, Z directions for 3 times Indicator Operation indicator:Red LED
Ambient temperature
Environ
-ment
Ambient humidity Protection circuit Surge protection circuit Protection IP67( EC standard)
Cable type Cable
2
Cable connector type
Insulation type
Material
Approval
3
Unit weight
1: The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard
sensing target, 1/2 of the sensing distance for the distance.
2: Do not pull the Ø4mm cable with a tensile strength of 30N or over and the Ø5mm cable with a tensile strength of 50N or over.
t may result in fire due to the broken wire. When extending wire, use AWG22 cable or over within 200m.
3: The weight with packaging and the weight in parentheses is only unit weight. ※Environment resistance is rated at no freezing or condensation.
PRW12-2AC
100-240VAC (85-264VACᜠ)
1
20Hz
-25 to 70℃, Storage: -30 to 80 35 to 95%RH, Storage: 35 to 95%RH
Ø4mm, 2 cores, 2m Ø5mm, 2 cores, 2m AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: Ø1.25mm Ø4mm, 2 cores, 300mm, M12 connector AWG22, core diameter: 0.08mm, number of cores: 60, insulator diameter: Ø1.25mm
Double insulation or reinfored insulation
(Mark: , dielectric strength between the measuring input part and the power part: 1kV) Case and nut: Nickel-plated brass, Washer: Nickel-plated steel, Sensing part: PBT,
General cable(Black): Polyvinyl chioride (PVC)
PR: Approx. 84g(Approx. 72g) PRW : Approx. 54g(Approx. 42g)
PR12-4AO PR12-4AC PRW12-4AO PRW12-4AC
PR18-5AO PR18-5AC PRL18-5AO PRL18-5AC PRW18-5AO PRW18-5AC PRWL18-5AO PRWL18-5AC
Ø5mm, 2 cores, 300mm, M12 connector
PR: Approx. 130g(Approx. 118g) PRL: Approx. 142g(Approx. 130g) PRW: Approx. 78g(Approx. 66g) PRWL: Approx. 90g(Approx. 78g)
PR18-8AO PR18-8AC PRL18-8AO PRL18-8AC PRW18-8AO PRW18-8AC PRWL18-8AO PRWL18-8AC
PR30-10AO PR30-10AC PRL30-10AO PRL30-10AC PRW30-10AO PRW30-10AC PRWL30-10AO PRWL30-10AC
PR: Approx. 207g(Approx. 170g) PRL: Approx. 245g(Approx. 208g) PRW: Approx. 134g(Approx. 122g) PRWL: Approx. 195g(Approx. 158g)
PR30-15AO PR30-15AC PRL30-15AO PRL30-15AC PRW30-15AO PRW30-15AC PRWL30-15AO PRWL30-15AC
Dimensions
Type M12 M18, M30 Nuts & Washer
B
C
Flush
·~~
Cable connector type
Non-ush
Type M12, M18, M30 Nuts & Washer
===p~~~~--=-
Flush
_________j___
Cable connector type
Non-ush
Item A B C D E F G H J
rt--"-~=+=r=n=~-
Flush
Non-
ush
PR
M12
PRW 300 PR PRW 300
M18
PRL PRWL 300 PR PRW 300
M30
PRL PRWL 300 PR
M12
PRW 300 PR PRW 300
M18
PRL PRWL 300 PR PRW 300
M30
PRL PRWL 300
E
~
D
B
C
-
D
_J1_
B
C
E
M12×1 63 48.5 4 - 4 17 21
M18×1 53.8 35.8 4 - 5 24 29
M18×1 80.5 62.5 4 - 5 24 29
M30×1 5 58 38 5 - 5 35 42
M30×1 5 80 60 5 - 5 35 42
M12×1 63 41.5 4 7 4 17 21
M18×1 53.3 25.3 4 10 5 24 29
M18×1 80 52 4 10 5 24 29
M30×1.5 58 28 5 10 5 35 42
M30×1.5 80 50 5 10 5
J
F
AD
B
C
J
F
A
~~~~-
____.!_____.
+
--
=r=-
A
IE-----=
F
-..
F
A
D
B
C
D
C
E
~
D
J
H
F
A
B
J
F
A
G
~
L~:_
J
M12×1
J
.•
M12×1
~~
35 42
H
G
ti
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
2,000
(Unit: mm)
Be sure to connect the power after connecting the load, because direct connection of he proximity sensor may cause damage to the inner circuit of his product.
100-240VAC 50/60Hz
Mutual-interference
When several proximity sensors are mounted closely, malfunction of sensor may be caused due to mutual interference. Therefore, be sure to keep a minimum distance between the two sensors, as below charts.
A
Inuence by surrounding metals
When sensors are mounted on metallic panel, it is required to protect the sensors from malfunction by any metallic object. Therefore, be sure to keep a minimum distance as below chart.
Model Item A 12 24 30 48 60 90 B 24 36 36 54 60 90 0 11 0 14 0 15 Ød 12 36 18 54 30 90 m 6 12 15 24 30 45 n 18 36 27 54 45 90
12-2A
PR PRW 12-2A
Face to Face
PR 12-4A PRW 12-4A
Setting Distance
Moving
direction
● Sensing distance can be changed by the shape, size or material of the target. Therefore please check the sensing distance as (a),
then pass the target wi hin range of setting distance(Sa) as (b).
● Setting distance(Sa) = Sensing distance(Sn)×70%
E.g.)PR30-10AO
Set ing distance(Sa) = 10mm×0.7=7mm
Installation and Tightening Torque
When tightening the nut, use the provided washer as [Figure 1] When installing the product, the tightening torque of the nut varies according to the distance from the fore-end. The front part of the product is from the fore-end to the dimension on the below table, and the rear part is from the tip of the nut to the end of the product. [Figure 2] In case the nut is placed in the front part of the product, apply tightening torque for front part. [Table 1] the allowable tightening torque table is for inserting the washer as [Figure 3].
[Figure 1]
Caution during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents.
2. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise. Do not use near the equipment which generates strong magnetic force or high frequency noise (transceiver, etc.). In case installing the product near the equipment which generates strong surge (motor, welding machine, etc.), use diode or varistor to remove surge.
3. Do not connect capacity load to the output terminal directly.
4. This unit may be used in the following environments.
Indoors (in the environment condition rated in 'Specications')
Altitude max. 2,000m
Pollution degree 2
Installation category II
Major Products
~
Photoelectric sensors Temperature controllers
Fiber optic sensors Temperature/Humidity transducers
Door sensors SSR/Power controllers
Door side sensors Counters
Area sensors Timers
Proximity sensors Panel meters
Pressure sensors Tachometer/Pulse(Rate) meters
Rotary encoders Display units
Connector/Sockets Sensor controllers
Switching mode power supplies
Control switches/Lamps/Buzzers
I/O Terminal Blocks & Cables
Stepper motors/drivers/motion controllers
Graphic/Logic panels
Field network devices
Laser marking system(Fiber, CO₂, Nd:YAG)
Laser welding/soldering system
[Figure 2] [Figure 3]
Fore-end
Nut tip
Front Rear
PR 18-5A PRW 18-5A
Target
Moving
direction
Sn:Sensig distance Sa:Setting distance (70% of Sn)
Ød
PR 18-8A PRW 18-8A
[Table 1]
Model PR12 Series
PR18 Series
PR30 Series
Washer
B
Target
Sn
Sa
(b)(a)
Front Rear
Strength
Flush 13mm Non -Flush 7mm Flush ­Non -Flush ­Flush 26mm Non -Flush 12mm
Size Torque Torque
Mounting
bracket
Load
Parallel
m
PR 30-10A PRW 30-10A
6 37N m 11.76N.m
14.7N m
49N.m 78.4N.m
100-240VAC
VsVs
50/60Hz
n
DRW171498AA
(Unit mm)
PR 30-15A PRW 30-15A
Loading...