Tenney ETCU Temperature Humidity Cycling Chambers
ETCU Temperature Humidity Cycling Chambers
The Tenney ETCU Ultimate Series Temperature Humidity Cycling Chamber
features scroll compressor technology that provides quiet operation, fast
transition rates, and reliable operations.
The chambers incorporate a ceiling plenum to diffuse conditioned air vertically
through the chamber. The top to bottom air circulation guarantees stable and
consistent performance over the testing period.
Multiple heating and cooling systems are available, as well as a diverse list of
options that together will create the chamber to accommodate your specific
application.
Features
• Quiet Operation
• Fast Transition Rates
• High Reliability
Refrigeration System
• Temperature and Humidity Testing
• Versa Tenn V control system
• Automatic Humidity Vent
Options:
• IEEE488 Interface
• LinkTenn 32 for Windows® That Permits Your
Computer to Control up to 10 Chambers
• 6-event Relay Board
• Water Demineralizer System
• Circular Recording Instruments
• Alternate Refrigeration and/or Heating Systems for
Faster Temperature Change Rates or Increased
Product Load-Handling Capabilities
• Additional Ports
* Contact TPS for details and availability
All performance data is for 230 or 460 v/60 Hz
operations. Chamber operations utilizing 50 Hz
power utility will derate performance
approximately 17%.
Model ETCU–09 ETCU–16 ETCU–30 ETCU–64
Interior Volume 9 cu. ft. 16 cu. ft. 30 cu. ft. 64 cu. ft.
256 liters 460 liters 850 liters 1,812 liters
Interior Dimensions 24 x 25 x 26 36 x 26 x 30 40 x 36 x 36 48 x 48 x 48
WxDxH - inches (mm) (610 x 635 x 660) (914 x 660 x 762) (1016 x 914 x 914) (1219 x 1219 x 1219)
Exterior Dimensions 34 x 73 x 78 46 x 74 x 82 50 x 87 x 88 58 x 99 x 100
WxDxH - inches (mm) (864 x 1854 x 1983) (1169 x 1881 x 2084) (1271 x 2211 x 2237) (1474 x 2516 x 2542)
Nominal Horsepower 3.5 x 3.5 6 x 6 10 x 10 3.5 x 3.5 6 x 6 10 x 10 3.5 x 3.5 6 x 6 10 x 10 15 x 15 3.5 x 3.5 6 x 6 10 x 10 15 x 15
Rated Horsepower 2.5 x 2.5 5 x 5 10 x 10 2.5 x 2.5 5 x 5 10 x 10 2.5 x 2.5 5 x 5 10 x 10 15 x 15 2.5 x 2.5 5 x 5 10 x 10 15 x 15
Compressor Type Scroll Scroll Scroll Scroll
Noise (dBa) Heating 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Cooling 68 75 75 68 75 75 68 75 75 75 68 75 75 75
Heating
Elements (Kw)
230/460 6 12 12 6 12 12 6 12 12 24 6 12 12 24
208V 4.5 9 9 4.5 9 9 4.5 9 9 18 4.5 9 9 18
Model ETCU–09 ETCU–16 ETCU–30 ETCU–64
Cooling Rate (min)
190
°
C to -65°C
49 34 14 78 36 19 155 76 31 20 256 125 52 42
71
°
C to -65°C
36 26 11 40 28 15 119 59 26 17 197 97 44 33
85
°
C to -40°C
27 18 8 32 20 12 95 42 21 12 157 69 36 24
Heating Rate (min)
-65
°
C to 190°C
35 16 16 32 22 22 60 30 30 20 110 53 53 27
-65
°
C to 71°C
17 8 8 14 11 11 27 13 13 10 45 23 23 13
-40
°
C to 85°C
16 8 8 12 10 10 27 13 13 11 45 23 23 14
Water Cooled Y Y YYYYYYYYYYYY
Air Cooled Y Y Y Y Y Y Y
208/230V-1 Ph Y N/A N/A Y N/A N/A Y N/A N/A N/A Y N/A N/A N/A
208/230V-3 Ph Y Y N/A Y Y N/A Y Y N/A N/A Y Y N/A N/A
460V-3 Ph Y YYYYYYYYYYYYY
Air Delivery
(Blower HP)
.5 HP (2) .5 HP (2) .75 HP (2) .75 HP
Airfl ow (CFM) 750 1600 1600 1600
Temp Unif. (Std
Dev/9 Pt)
+/-0.5
°
C/+/-1°C +/-0.5°C/+/-1°C +/-0.5°C/+/-1°C +/-0.5°C/+/-1°C
Temp Control
+/-0.3
°
C +/-0.3°C +/-0.3°C +/-0.3°C
Specifications & Product Information is subject to change without notice.
Images for reference only. Options and accessories may not be included with all models.
* Single Stage Refrigeration Temperature Range: -35°C to 200°C
* Performance is based upon an empty chamber operatfing at 24°C (75°F) ambient air and may vary slightly at other ambient temperatures. Voltages
below those listed may affect performance. All performance data is for 240 or 480V / 60Hz operation.
* Liquid Nitrogen is available as an option on all systems. When Liquid Nitrogen is provided, the heater KW is automatically upgraded to the maximum
for that chamber size. Consult factory for current draw of any Liquid Nitrogen equipped chambers.
* Airflow circulation is based on blower wheel performance curves. Actual circulation rate will vary depending on the cooling option selected.
* Temperature uniformity Standard deviation from the mean, measured at –25°C and 100°C. 9 Point: Uniformity measured in accordance with ASTM
E145 section 4 at temperatures of –25°C and 100°C.
* Test chamber performance may be affected by the addition of certain optional accessories.
* Chamber operation utilizing 50Hz power utility will derate performance approximately 17%
* It is Thermal Product Solutions' policy to constantly improve quality, features and performance. Thermal Product Solutions reserves the right to
change specifications without notice.
Gruenberg, Blue M, Tenney
Mailing Address: P.O. Box 150 | White Deer, P
Phone: (570) 538-7200 | Fax: (570) 538-7380
Physical Address: 2821 Old Route 15 | New Columbia, PA 17856-9396
TPSinfo@tps.spx.com
A 17887-0150 | USA |