Cool Down Transition Time (empty)*
Heat Up Transition Time (empty)*
Programmable Controller
Up to 256 steps can be programmed into as 
many as 40 nameable profiles. The context 
sensitive information key and guided steps 
make profile programming fast and easy. A 
four-line backlit LCD displays programming, 
setup, operating and help information. A 
large LED readout indicates the actual 
chamber temperature with 0.1° resolution. 
Internal logic provides refrigeration 
compressor control for responsive and 
reliable performance. Includes an RS-232 
interface. Optional GPIB interface is 
available.
High/Low Limit Controller
Provides independent protection against 
excess temperatures. Both high and low 
limits can be set. The limit controller will 
shut down the chamber in the event of an out 
of limit condition.
Model 105A Half Cube™Temperature Chamber
Also Available for Rent
TestEquity LLC
2450 Turquoise Circle 
Thousand Oaks, CA 91320
800-732-3457 
805-498-9933
www.testequity.com
©TestEquity 8.06
Chamber Performance
Temperature Range -40°C to +130°C 
Control Tolerance ±0.5°C (±0.2°C Typical) 
(Measured at the control sensor after stabilization)
Unif ormit y ±1.0°C (±0.5°C Typical) 
(Variations throughout the chamber after stabilization)
Live Load Capacity +23°C 0°C -10°C -20°C -30°C -40°C
200 Watts 175 Watts 165 Watts 145 Watts 90 Watts 10 Watts
End Temp
Start 
Te mp
+23°C +50°C +85°C
+23°C ------- 1.5 min 6 min
0°C 2 min 4 min 7.5 min
-20°C 3 min 5 min 8 min
-40°C 4.5 min 7.5 min 11 min
End Temp
Start 
Te mp
Rate of Change: To calculate rate of change for a particular condition, take the difference
between the Start Temp and End Temp and divide by the Transition Time. 
Cool Down Example (empty): From +85°C to -20°C = 105°C / 17 min = 6.18°C/min. 
Heat Up Example: From -40°C to +85°C = 125°C / 11 min = 11.36°C/min. 
* Note: Transition times are measured after a 30 minute soak at the respective start temperature.
Physical Characteristics and Safety
Inside Dimensions 12" W x 9" H x 8" D (0.5 cubic feet)
Outside Dimensions 16.5" W x 26" H x 20" D (nominal)
Door latch adds 2" to width. 
Circulator motor housing adds 1" to depth in rear.
Min. Installed Clearance 12" from the rear.
Access Ports 2" Port on left and right side (two total)
Supplied with silicone foam plugs
We ig h t Chamber Weight: 114 pounds
Shipping Weight: 140 pounds
Safety Designed to meet UL STD 3101-1 
and CAN/CSA STD C22.2 No. 1010.1
+23°C 0°C -10°C -20°C -30°C -35°C -40°C
+23°C ------- 3 min 5 min 7 min 10 min 13 min 22 min 
+85°C 8 min 13 min 15 min 17 min 20 min 23 min 31 min
Power Requirements
Note: Performance is typical and based on operation at 23°C (73°F) ambient and nominal
input voltage. Designed for use in a normal conditioned laboratory. Operation at higher 
ambient temperatures will result in decreased cooling performance. Low end limit 
derates to -38°C when operating above 27°C (80°F) ambient. Operation above 30°C 
(85°F) or below 16°C (60°F) ambient is not recommended.
Refrigeration and Heating System
Compressor 1/3 HP Copeland hermetic
Condenser Air Cooled
Heater Power 500 Watts
Input Voltage 120 V nominal (110 to 126 VAC), 60 Hz, 1 PH
Current Draw Max Current Draw 10 A, Recommended Service 15 A.
Instrumentation
Temperature Controller 256 steps, 40 profiles, ramp and soak programmable 
memory. RS-232C interface.
Limit Controller Independent high and low temperature limits, user 
adjustable.
Plugs Into Any 120V Outlet
The Half Cube draws only 10 Amps 
maximum at 120 Volts. You can plug it 
into any standard wall receptacle, with 
plenty of power to spare for other 
equipment.
Reversible Chamber Door
You won’t need to rearrange your whole 
bench or workflow to accommodate the 
Half Cube. The chamber door is 
reversible, allowing the door to open 
from the left or right side. This is also 
useful when placing two Half Cube 
chambers side-by-side.
Shown on 
optional 
cart.
Available Options
 GPIB Interface 
 Extra Shelf 
 Rackmount Adapter 
 50 Hz Export Version 
 Cart