Atec ENI-EI-1040L User Manual

1387 Brighton Henrietta Townline Rd Rochester, NY 14623 Tel: (585) 214 0598 Fax: (585) 214 0580
www.eandiltd.com
1040L POWER AMPLIFIER
400 Watts of RF Power For Industrial, Lab & Medical Use,
Featuring;
- 10 KHz – 5 MHz
- Power Measurement o Forward & Reflected
- Solid State Reliability
- Forced Air Cooling
The 1040L Amplifier is a rugged source of RF power for ultrasonics, induction heating and laser modulation as well as plasma applications. It is a totally solid state solution employing RF DMoS FETs in the power amplification stages, offering simultaneous forward and reverse power readouts, and RS232 port for data collection. The 1040L reflects E&I’s commitment to reliable and robust RF power.
Flexible Operation:
The 1040L produces 400 Watts of quasi linear class AB power over a frequency range of 10 KHz to 5 MHz, with a nominal power gain of 55 dB (+/-1dB). Operation over the entire frequency range is possible without the need for any switching.
The front panel display provides simultaneous measurements of forward and reflected power as well as the unit’s status. The RS232 connector at the rear of the unit can also be used to capture this data and reset the unit should a fault occur.
The E&I 1040L is a 19” rack mount unit 3U high. It employs an integral power supply capable of operation at 115 or 220 VAC, 50 – 60 Hz. The unit weighs approximately 45 lbs or 16 Kg.
1387 Brighton Henrietta Townline Rd Rochester, NY 14623 Tel: (585) 214 0598 Fax: (585) 214 0580
www.eandiltd.com
1040L POWER AMPLIFIER
Class of Operation
Class AB
Frequency Range
10 to 5000 KHz
Rated Power Output
400 Watts
Saturated Power Output
500 Watts
Power Gain
55 dB nominal
Gain Flatness
+/- 1 dB to 1 MHz
- 2 dB to 5 MHz
Input Power for Rated Output
1.3 mW or 1.14dBm
Input Impedance
50
Output Impedance
50
Ruggedness
Any load VSWR, any phase from open to Short circuit without damage.
Front Panel Accuracy +/- 3%
Drive Source Requirements
Any signal Generator, function Generator or oscillator capable of up to 0.7 Vpp into 50
Protection:
INPUT: unit will withstand up to +13dBm input without damage.
MISMATCH: the unit will tolerate any mismatch subject to thermal and current protection.
Accessories Supplied
The unit is supplied with an operations manual and AC line cord.
Temperature Range
0 – 45O C
AC Power Requirements
104 – 240 VAC 9 A @ 120 V
4.5 A @ 240 V
Cooling
Forced air.
Weight
45 lbs (16 KG)
Dimensions
(H x W x D)
5.3” x 16.5” x 18.4”
134.5 mm x 420 mm x 467 mm
Loading...