Features:
●
9 kHz to 30 MHz Frequency Range
●
25 A Continuous Current Rating
●
Earth Line Choke
●
Artificial Hand Network
●
Choice of EUT Power Adapter Boxes
Test Site Hardware
LISN Model 4825/2
●
IEC 1010 Compliant
EMCO’S LISN Model 4825/2 is a two-line,
low pass, filter network used for conducted emissions measurements. The
product is placed between the power
mains and the equipment under test
(EUT) to stabilize line impedance,
provide a 50 ohm RF connection, and
eliminate unwanted RF signals from the
line supply.
LISNs play an important role in achieving test accuracy. Without a LISN,
conducted interference on the power
mains can disrupt measurement
reliability. Also, line impedance variances
from one test site to another can degrade
repeatability. With a LISN integrated into
the test system, conducted RF interference is filtered and a stable line impedance is assured.
The Model 4825/2 is designed and tested
in accordance with IEC Publication 1010,
Safety Requirements for Electronic
Measur ing App aratus. It has als o received
CSA safety certification from the
Canadian Standards Association, a
further indication of EMCO's commitment to safety.
This product covers the frequency
spectra of 9 kHz to 30 MHz and is
designed to be used with a signal
analyzer for making FCC 15, VDE 0871 &
0875, EN 55022 and CISPR 22 conformance measurements.
Features
Earth Line Choke
A safety ground isolation choke selector
switch, located on the front panel,
switches the 1.6 microhenry earth line
choke "IN" and "OUT" of the safety
ground circuit. When the selector is
switched to the "IN" position, the unit
isolates the EUT from RF ground while
maintaining a safety ground.
Artificial Hand
An Artificial Hand circuit which conforms
to EN 55014 and BS 800 is included. The
circuit is useful for testing hand-held
equipment which does not have a
connection to protective earth ground.
High Pass Filter
A high pass filter is included on each
monitor port, preventing potential
overload to the analyzer and eliminating
the need to apply correction factors to
measurements.
Overcurrent Protection
To protect test equipment, a switchable,
two-pole circuit breaker is mounted on
LISN Model 4825/2
the rear panel. Providing excellent
overcurrent protection, the circuit
breaker is rated at 250 VAC, 50/60 Hz at
25 amperes.
EUT Power Adapter Boxes
The EUT is connected to the LISN
through an interchangeable power
adapter mounted on the front panel of
the unit. This convenient feature enables
users who are responsible for testing
products with worldwide distribution to
quickly switch from one receptacle type
to another. Please specify the receptacle
types required when placing an order.
One (1) adapter box with a single
receptacle type is standard. See Options
section for details on ordering more than
one type of adapter box.
Standard Configuration
●
LISN assembly
●
One (1) EUT Adapter Box. Please specify
receptacle type when placing order.
●
Individually calibrated per ANSI C63.4.
Actual insertion loss and impedance data
and a signed Certificate of Conformance
included in Manual.
USA:
Tel +1.512.835.4684
Fax +1.512.835.4729
Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications. 6/00 - 500 © 2000 ETS-Lindgren REV B
FINLAND:
Tel +358.2.838.3300
Fax +358.2.865.1233
SINGAPORE:
Tel +65.536.7078
Fax +65.536.7093
ONLINE:
info@emctest.com
http://www.emctest.com
1
TM
Test Site Hardware
EMC TEST SYSTEMS, L.P. – An ESCO Company
EMCO
NEMA
BRITISH
Select From Four Interchangeable
EUT Power Adapters
SCHUKO
AUSTRALIAN
Options
EUT Adapter Boxes
Choose from four detachable power
adapters that can be mounted on the
front panel of the unit. One (1) is
included as standard, others can be
purchased as options.
NEMA 125 VAC 15/20 amp simplex
(P/N105782)
Schuko 230 VAC 16 A (P/N105783)
British 230 VAC 13 A (P/N105784)
Australian 230 VAC 10/15 A (P/N105803)
LISN Model 4825/2
Physical Specifications
MODEL WIDTH DEPTH HEIGHT WEIGHT
4825/ 2 43.8 cm 38.1 cm 13.3 cm 11.3 kg
17.3 in 15.0 in 5.3 in 25.0 lb
Model 4825/2 Back View
Applications
MODEL TEST TYPE
FCC-15 VDE 0871 VDE 0875 EN55022 CISPR
4825/2 CE CE CE CE CE
CE = Conducted Emissions
MP4 Cord Loom
Provides a repeatable method for looping
excess cord in serpentine fashion, per MP4.
Operational Features
MODEL MANUAL SWITCHED ARTIFICIAL HIGH PASS FILTER OVERCURRENT EUT
4825/ 2 ✔✔✔ ✔✔
EARTH LINE CHOKE HAND PROTECTION ADAPTER BOXES
Electrical Specifications
MODEL LINES FREQUENCY POWER MAXIMUM MAXIMUM NETWORK POWER IN POWER OUT
4825/ 2 NM 2 9 kHz – 30 MHz 60 Hz 25 A 125 VAC Line to Ground 50 mH / 250 mH IEC 309
USA:
Tel +1.512.835.4684
Fax +1.512.835.4729
Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications. 6/00 - 500 © 2000 ETS-Lindgren REV B
PLUS RANGE SOURCE CURRENT VOLTAGE INDUCTANCE CONNECTOR CONNECTOR
GROUND FREQUENCY IMPEDANCE
SH 50 Hz 250 VAC Line to Ground 50 W 32 A
BS 50 Hz 250 VAC Line to Ground mating plug
AS 50 Hz 250 VAC Line to Ground supplied
FINLAND:
Tel +358.2.838.3300
Fax +358.2.865.1233
SINGAPORE:
Tel +65.536.7078
Fax +65.536.7093
ONLINE:
info@emctest.com
http://www.emctest.com
®
NEMA
®
SCHUKO
British
Australian
2