Atec EMCO-4825-2 User Manual

TM
EMC TEST SYSTEMS, L.P. – An ESCO Company
EMCO
Features:
9 kHz to 30 MHz Frequency Range
25 A Continuous Current Rating
Earth Line Choke
Artificial Hand Network
Choice of EUT Power Adapter Boxes
Test Site Hardware
LISN Model 4825/2
IEC 1010 Compliant
EMCO’S LISN Model 4825/2 is a two-line,
low pass, filter network used for con­ducted emissions measurements. The product is placed between the power mains and the equipment under test (EUT) to stabilize line impedance, provide a 50 ohm RF connection, and eliminate unwanted RF signals from the line supply.
LISNs play an important role in achiev­ing test accuracy. Without a LISN, conducted interference on the power mains can disrupt measurement reliability. Also, line impedance variances from one test site to another can degrade repeatability. With a LISN integrated into the test system, conducted RF interfer­ence is filtered and a stable line imped­ance is assured.
The Model 4825/2 is designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measur ing App aratus. It has als o received CSA safety certification from the Canadian Standards Association, a further indication of EMCO's commit­ment to safety.
This product covers the frequency spectra of 9 kHz to 30 MHz and is designed to be used with a signal
analyzer for making FCC 15, VDE 0871 & 0875, EN 55022 and CISPR 22 conform­ance measurements.
Features
Earth Line Choke
A safety ground isolation choke selector switch, located on the front panel, switches the 1.6 microhenry earth line choke "IN" and "OUT" of the safety ground circuit. When the selector is switched to the "IN" position, the unit isolates the EUT from RF ground while maintaining a safety ground.
Artificial Hand
An Artificial Hand circuit which conforms to EN 55014 and BS 800 is included. The circuit is useful for testing hand-held equipment which does not have a connection to protective earth ground.
High Pass Filter
A high pass filter is included on each monitor port, preventing potential overload to the analyzer and eliminating the need to apply correction factors to measurements.
Overcurrent Protection
To protect test equipment, a switchable, two-pole circuit breaker is mounted on
LISN Model 4825/2
the rear panel. Providing excellent overcurrent protection, the circuit breaker is rated at 250 VAC, 50/60 Hz at 25 amperes.
EUT Power Adapter Boxes
The EUT is connected to the LISN through an interchangeable power adapter mounted on the front panel of the unit. This convenient feature enables users who are responsible for testing products with worldwide distribution to quickly switch from one receptacle type to another. Please specify the receptacle types required when placing an order. One (1) adapter box with a single receptacle type is standard. See Options section for details on ordering more than one type of adapter box.
Standard Configuration
LISN assembly
One (1) EUT Adapter Box. Please specify receptacle type when placing order.
Individually calibrated per ANSI C63.4. Actual insertion loss and impedance data and a signed Certificate of Conformance included in Manual.
USA:
Tel +1.512.835.4684 Fax +1.512.835.4729
Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications. 6/00 - 500 © 2000 ETS-Lindgren REV B
FINLAND:
Tel +358.2.838.3300 Fax +358.2.865.1233
SINGAPORE:
ONLINE:
info@emctest.com http://www.emctest.com
1
TM
Test Site Hardware
EMC TEST SYSTEMS, L.P. – An ESCO Company
EMCO
NEMA
BRITISH
Select From Four Interchangeable
EUT Power Adapters
SCHUKO
AUSTRALIAN
Options
EUT Adapter Boxes
Choose from four detachable power adapters that can be mounted on the front panel of the unit. One (1) is included as standard, others can be purchased as options.
NEMA 125 VAC 15/20 amp simplex (P/N105782) Schuko 230 VAC 16 A (P/N105783) British 230 VAC 13 A (P/N105784) Australian 230 VAC 10/15 A (P/N105803)
LISN Model 4825/2
Physical Specifications
MODEL WIDTH DEPTH HEIGHT WEIGHT
4825/ 2 43.8 cm 38.1 cm 13.3 cm 11.3 kg
17.3 in 15.0 in 5.3 in 25.0 lb
Model 4825/2 Back View
Applications
MODEL TEST TYPE
FCC-15 VDE 0871 VDE 0875 EN55022 CISPR
4825/2 CE CE CE CE CE
CE = Conducted Emissions
MP4 Cord Loom
Provides a repeatable method for looping excess cord in serpentine fashion, per MP4.
Operational Features
MODEL MANUAL SWITCHED ARTIFICIAL HIGH PASS FILTER OVERCURRENT EUT
4825/ 2 ✔✔✔ ✔✔
EARTH LINE CHOKE HAND PROTECTION ADAPTER BOXES
Electrical Specifications
MODEL LINES FREQUENCY POWER MAXIMUM MAXIMUM NETWORK POWER IN POWER OUT
4825/ 2 NM 2 9 kHz – 30 MHz 60 Hz 25 A 125 VAC Line to Ground 50 mH / 250 mH IEC 309
USA:
Tel +1.512.835.4684 Fax +1.512.835.4729
Information presented is subject to change as product enhancements are made. Contact ETS-Lindgren Sales Department for current specifications. 6/00 - 500 © 2000 ETS-Lindgren REV B
PLUS RANGE SOURCE CURRENT VOLTAGE INDUCTANCE CONNECTOR CONNECTOR
GROUND FREQUENCY IMPEDANCE
SH 50 Hz 250 VAC Line to Ground 50 W 32 A BS 50 Hz 250 VAC Line to Ground mating plug AS 50 Hz 250 VAC Line to Ground supplied
FINLAND:
Tel +358.2.838.3300 Fax +358.2.865.1233
SINGAPORE:
ONLINE:
info@emctest.com http://www.emctest.com
®
NEMA
®
SCHUKO British Australian
2