ARISTON TVM 70C 6P (EX) 60HZ User Manual

Instruction booklet
Instruction booklet
TUMBLE DRYER
TUMBLE DRYER
Contents
GB
English, 1
PT
Português, 31
TVM 70
FR
Français, 11
AR
52, ،يبرع
NL
ES
Español, 21
NL
FA
Farsi, 64
Installation, 2
Warnings, 4
Care and Maintenance, 6
Description of the tumble dryer, 7
Control Panel, 7
Start and Programmes, 7
Laundry, 8
Service, 10
www.aristonchannel.com
This symbol reminds you to read this
instruction manual.
Keep this manual at hand for immediate reference whenever
necessary. Always store this manual close to the tumble dryer and
remember to pass it on to any new owners when selling or tran-
sferring the appliance, so they may familiarise with the warnings
and suggestions herein contained.
Read these instructions carefully: the following pages contain
important information on installation and useful suggestions for
operating the appliance.
1
Installation
m
B
A
GB
Where to install the tumble dryer
If the dryer is installed below a worktop, ensure there are 10 mm between the upper panel of the dryer and any objects above it, and 15 mm between the sides of the machine and the walls or furniture units adjacent to it. This en­sures adequate air cir­culation. Make sure the air inlets on the rear panel are not blocked or obstructed.
Ventilation
This appliance gently dries laundry by taking in cold, clean and relatively dry air, heating it and passing it through the fabric. To facilitate the drying process, damp air is expelled at the rear, through a ventilation hose. When the dryer is in use, there has to be adequate ventilation to avoid a back flow of gases into the room from appliances burning other fuels, including open fires.
Mobile ventilation system
When using the tumble dryer with the mobile ventilation system, a ventilation hose must be connected. The hose should be securely fastened to the ventilation hole at the rear of the appliance (see “Description of the tumble dryer”). We recommend the hose is connected to an outlet near the tumble dryer, if possible. If it cannot be installed in a permanent spot, the tumble dryer will still function perfectly well if the ventilation hose is passed through a partially­opened window. Make sure you do not point the ventilation hose towards the air inlet, which is located on the rear of the appliance. The ventilation hose should not exceed a maximum length of 2.4 metres; it should also be shaken frequently to remove any fluff, dust or water deposits inside it. Make sure you do not crush the hose.
Fixed ventilation system
We recommend the ventilation hose is connected to a ventilation system for windows or doors, available from the retailer which originally sold you the appliance or from your local spare parts stockist.
Wall ventilation hole
1. Leave an opening in the wall to the left of the tumble dryer installation site.
2. Make the hose as short and straight as possible, in order to prevent any moisture from condensing and leaking back into the appliance.
3. The hole in the wall must also be straight and pointing downwards, so that the flow of air coming out is not impeded. Areas A and B should be checked frequently, to prevent the accumulation of fluff or debris, particularly if the tumble dryer is used very often. The hose adaptor must be fitted correctly, in order to prevent damp air from coming back into the room.
Window ventilation hole
The ventilation hole should be directly behind the dryer in
order to keep the hose as short as possible. Make sure you do not push the tumble dryer too far backwards, as this could lead to the ventilation hose being crushed, bent or even disconnected. There should be no cuts, kinks or “U”-shaped bends in the hose, as these could impede
ventilation or trap condensation. The end of the hose must be facing downwards, in order to prevent the hot, damp air from forming condensation in the room or the tumble dryer. Make sure that the tumble dryer is adequately ventilated, and that the end of the ventilation hose is not pointing
towards the air inlet pipe on the rear of the appliance. The ventilation hose must always be fitted to ensure optimum performance. Make sure that the ventilation hose and the air inlet vents are not obstructed or blocked. Do not let the tumble dryer recirculate exhaust air. Improper use of the tumble
dryer may result in fire hazards.
Ventilation through an open window
The air emitted by the tumble dryer must not be expelled in the same duct as used for the fumes produced by different appliances which burn gas or other fuels. Do not discharge the exhaust air into an extraction system or any duct with an extractor fan. This will affect the way the
thermal controls operate and can result in a fire hazard.
Make sure that the room in which the tumble dryer is installed is not damp, and that it is adequately ventilated.
We do not recommend that the dryer is installed in a cupboard but the dryer must never be installed behind a lockable door, a sliding door or a door with a hinge on the opposite side to that of the dryer door.
The appliance must be installed with the
rear surface placed against a wall.
2
Electrical connections
Before plugging the appliance into the socket, check the following:
Make sure your hands are dry.
The socket must have an earth connection.
The socket must be able to withstand the machine’s maximum power output as indicated on the rating plate (see Description
of the tumble dryer).
GB
The power supply voltage must fall within the values indicated on the rating plate (see
Description of the tumble dryer).
Do not use extension leads. Do not pull the power supply cable. Do not use multiple plug adaptors if the appliance is fitted with a plug. For appliances with fitted plug, if the plug is not suitable for you socket outlet, contact a qualified technician.
The dryer must not be installed outdoors, even if the space is sheltered.
Once installed, the dryer’s electrical wire and plug must be within reach.
The power cord must not be bent or squashed.
Levelling the tumble dryer
The tumble dryer should be installed level in order to operate correctly.
After installing the tumble dryer in its permanent position, make sure it is level; check its side-to-side levelling first, followed by front-to-back.
If the tumble dryer is not perfectly level, use a wooden block to support it while you adjust the two front feet, up or down as necessary.
Before you start your dryer
Once the tumble dryer is installed, clean the inside of the drum before operating it and remove any dirt accumulated during transportation.
If the plug being replaced is a non­rewirable type, then the cut-off plug must be disposed of safely. DO NOT leave it where it can be inserted into a socket and create a shock hazard.
The electric cord must be regularly checked. If the supply cord is damaged, it must be replaced by service agent. (see
Service).
The manufacturer denies any responsibility should any of these rules not be followed.
If in doubt about any of the above consult a qualified electrician.
3