ARISTON PK 640 R L GH AG User Manual

PK 640 RL GH AG PK 741 RQO GH AG PK 750 RL GH AG PK 760 RF GH AG
English

Operating Instructions

HOB
Contents
Operating Instructions,1 Warnings,2 Assistance,4 Description of the appliance,5 Installation,7 Start-up and use,12 Precautions and tips,14 Maintenance and care,14 Troubleshooting,15
Español

Manual de instrucciones

ENCIMERA
Sumario
Portuges

Instruções para a utilização

PLANO
Índice
Instruções para a utilização,1 Advertências,3 Assistência,4 Descrição do aparelho,6 Instalação,27 Início e utilização,32 Precauções e conselhos,34 Manutenção e cuidados,34 Anomalias e soluções,35
Manual de instrucciones,1 Advertencias,2 Asistencia,4 Descripción del aparato,5 Instalación,16 Puesta en funcionamiento y uso,23 Precauciones y consejos,25 Mantenimiento y cuidados,25 Anomalías y soluciones,26

Warnings

Advertencias

WARNING: The appliance and its accessible parts become hot during use. Care should be taken to avoid touching heating elements. Children less than 8 years of age shall be kept away unless continuously supervised. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
WARNING: Unattended cooking on a hob with fat or
oil can be dangerous and may result in re. NEVER try to extinguish a re with water, but switch off the appliance and then cover ame e.g. with a lid or a re blanket.
WARNING: Danger of re: do not store items on the
cooking surfaces. WARNING: If the surface in glass-ceramic is cracked,
switch off the appliance to avoid the possibility of electric shock.
Never use steam cleaners or pressure cleaners on the appliance.
Remove any liquid from the lid before opening it. Do not close the glass cover (if present) when the gas burners or electric hotplates are still hot.
The appliance is not intended to be operated by means of an external timer or separate remote control system.
CAUTION: the use of inappropriate hob guards can cause accidents.
ATENCIÓN: Este aparato y sus partes accesibles se
vuelven muy calientes durante el uso. Por lo tanto, es importante evitar tocar los elementos calentadores. Mantenga alejados a los niños menores de 8 años si
no son continuamente vigilados. El presente aparato
puede ser utilizado por niños mayores de 8 años y por personas con capacidades físicas, sensoriales o mentales disminuidas o sin experiencia ni conocimientos, si se encuentran bajo una adecuada vigilancia o si han sido instruidos sobre el uso del aparato de modo seguro y comprenden los peligros relacionados con el mismo. Los niños no deben jugar con el aparato. Las operaciones de limpieza y de mantenimiento no deben ser realizadas por niños sin vigilancia.
ATENCIÓN: Dejar un quemador con grasas o aceites
sin vigilancia puede ser peligroso y provocar un incendio. NUNCA intente apagar una llama/incendio con agua, se debe apagar el aparato y cubrir la llama, por ejemplo, con una tapa o con una manta ignífuga.
ATENCIÓN: Riesgo de incendio: no deje objetos sobre las supercies de cocción.
ATENCIÓN: Si la supercie de vitrocerámica está
agrietada, apague el aparato para evitar sacudidas eléctricas.
No utilice nunca limpiadores a vapor o de alta presión para la limpieza del aparato.
Elimine eventuales líquidos presentes sobre la tapa
antes de abrirla. No cierre la tapa de vidrio (si existe) cuando los quemadores o la placa eléctrica todavía
están calientes. El aparato no se debe poner en funcionamiento a
través de un temporizador externo o de un sistema de mando a distancia.
“CAUTION: In case of hotplate glass breakage:
- shut immediately off all burners and any electrical heating element and isolate the appliance from the power supply
- do not touch the appliance surface“
2
ATENCIÓN: el uso de protecciones inapropiadas
de la placa de cocción puede provocar accidentes.
ATENCIÓN: Si se dañara la supercie de vidrio:
- apague inmediatamente todos los quemadores y eventuales elementos calentadores eléctricos y
O aparelho não é destinado a ser colocado em funcionamento por meio de um temporizador externo ou por um sistema de comando à distância separado.
desconecte el aparato de la red eléctrica.
- no toque la supercie del aparato.
ATENÇÃO: O uso de protecções do plano
inadequadas pode causar incidentes.
ATENÇÃO: Em caso de danos do plano em vidro:
- Desligue imediatamente todos os queimadores e

Advertências

ATENÇÃO: Este aparelho e as suas partes
acessíveis aquecem muito durante a utilização.
eventuais elementos de aquecimento eléctricos e desligue o aparelho da rede eléctrica.
- Não toque na superfície do aparelho.
É preciso ter atenção e evitar tocar os elementos que aquecem. Manter afastadas as crianças com menos de 8 anos, caso não estejam a ser vigiadas. O presente aparelho pode ser utilizado por crianças com mais de 8 anos e por pessoas com capacidades físicas, sensoriais ou mentais reduzidas ou com pouca experiência e conhecimentos, caso sejam adequadamente vigiadas ou caso tenham recebido instruções em relação ao uso do aparelho de forma segura e tenham conhecimento dos perigos associados. As crianças não devem brincar com o aparelho. As operações de limpeza e manutenção não devem ser efectuadas por crianças sem vigilância.
ATENÇÃO: Deixar um fogão com gordura e óleo sem
vigilância pode ser perigoso e provocar um incêndio.
NUNCA tente apagar as chamas com água. É necessário desligar o aparelho e cobrir as chamas
com uma tampa ou com uma manta ignífuga.
ATENÇÃO: Risco de incêndio: não deixe objectos
sobre as superfícies de cozedura.
ATENÇÃO: Se a superfície vitrocerâmica estiver
rachada, desligue o aparelho para evitar a possibilidade de choques eléctricos.
Nunca utilize equipamento de limpeza a vapor ou de alta pressão para limpar o aparelho.
Elimine os líquidos presentes na tampa antes de
abri-la. Não feche a tampa de vidro (se presente) se os queimadores ou a chapa eléctrica ainda estiverem quentes.
3

Assistance

Communicating:
type of trouble
appliance model (Mod.)
serial number (S/N)
This information is found on the data plate located on the appliance and/or on the packaging.

Asistencia

Comunique:
el tipo de fallo
el modelo de la máquina (Mod.)
el número de serie (S/N) Esta información se encuentra en la placa de características ubicada en el
aparato y/o en el embalaje.
La siguiente información es válida solo para España. Para otros países de habla hispana consulte a su vendedor.
Ampliación de garantía
Llame al 902.363.539 y le informaremos sobre el fantástico plan de ampliación de garantía hasta 5 años. Consiga una cobertura total adicional de
Piezas y componentes
Mano de obra de los técnicos
Desplazamiento a su domicilio de los técnicos
Y NO PAGUE AVERIAS NUNCA MAS
Servicio de asistencia técnica (SAT)
Llame al 902.133.133 y nuestros técnicos intervendrán con rapidez y ecacia, devolviendo el electrodoméstico a sus condiciones óptimas de
funcionamiento.
En el SAT encontrará recambios, accesorios y productos especícos para
la limpieza y mantenimiento de su electrodoméstico a precios competitivos.
ESTAMOS A SU SERVICIO

Assistência

Comunique:
o tipo de falha
o modelo da máquina (Mod.)
o número de série (S/N) Estas últimas informações encontram-se na placa de identicação situada
no aparelho e/ou na embalagem.
4

Description of the appliance

1
1
4
2
2
4
8
6
5

Descripción del aparato

Overall view
1. Support Grid for COOKWARE
2. GAS BURNERS
3. CERAMIC GLASS MODULE*
4. Control Knobs for GAS BURNERS
5. INDICATOR LIGHT FOR CERAMIC GLASS MODULE*
6. Control Knobs for CERAMIC GLASS MODULE*
7. Ignition for GAS BURNERS*
8. SAFETY DEVICES*
• The INDICATOR LIGHT for CERAMIC GLASS MODULE* switches on
whenever the selector knob is moved from the ‘off’ position.
GAS BURNERS differ in size and power. Use the diameter of the cookware
to choose the most appropriate burner to cook with.
• Control Knobs for GAS BURNERS and CERAMIC GLASS MODULE*
adjust the power or the size of the ame.
GAS BURNER IGNITION* enables a specic burner to be lit automatically.
SAFETY DEVICE* stops the gas flow if the flame is accidentally
extinguished.
* Only available on certain models.
Vista en conjunto
1. Parrillas de apoyo para RECIPIENTES DE COCCIÓN
2. QUEMADORES A GAS
3. PLACA VITROCERÁMICA*
4. Mandos de los QUEMADORES A GAS
5. Piloto de funcionamiento de la PLACA VITROCERÁMICA*
6. Mandos de las PLACA VITROCERÁMICA*
7. Bujía de encendido de los QUEMADORES A GAS*
8. DISPOSITIVO DE SEGURIDAD*
• Piloto de FUNCIONAMIENTO DE LA PLACA VITROCERÁMICA*: se
enciende cuando el mando está en cualquier otra posición que no sea la
de apagado.
QUEMADORES A GAS: son de distintas dimensiones y potencias. Elija
siempre el más adecuado para el diámetro del recipiente que va a utilizar.
• Mandos de los QUEMADORES A GAS y de la PLACA VITROCERÁMICA*
para la regulación de la llama o de la potencia.
• Bujía de encendido de los QUEMADORES A GAS*: permite el encendido
automático del quemador.
DISPOSITIVO DE SEGURIDAD:* si se apaga accidentalmente la llama,
interrumpe la salida de gas.
* Presente sólo en algunos modelos.
3
4
7
5

Descrição do aparelho

1
1
4
2
2
4
8
6
5
Vista de conjunto
1. Grades de suporte para RECIPIENTES DE COZEDURA
2. QUEIMADORES A GÁS
3. CHAPAS PARA COZER DE VIDRO CERÂMICA*
4. Selectores de comando dos QUEIMADORES A GÁS
5. Indicador luminoso DAS CHAPAS PARA COZER DE VIDRO CERÂMICA*
6. Selectores de comando das VIDRO CERÂMICA*
7. Vela para acender os QUEIMADORES A GÁS*
8. DISPOSITIVO DE SEGURANÇA*
• Indicador luminoso FUNCIONAMENTO CHAPA PARA COZER DE VIDRO CERÂMICA* acende-se se o selector estiver em qualquer posição diferente
daquela de desligado.
• Os QUEIMADORES são de diferentes tamanhos e potências. Escolha o
mais adequado ao diâmetro do recipiente a ser utilizado.
• Selectores de comando dos QUEIMADORES A GÁS e da VIDRO CERÂMICA* para a regulação da chama ou da potência.
• Vela para acender os QUEIMADORES A GÁS* permite o acendimento automático do queimador escolhido.
DISPOSITIVO DE SEGURANÇA* no caso em que a chama se apague acidentalmente, interrompe a saída do gás.
* Há somente em alguns modelos.
3
4
7
6

Installation

555 mm
55 mm
475 mm
! Before operating your new appliance please read this instruction booklet carefully. It contains important information for safe use, installation and care of the appliance.
! Please keep these operating instructions for future reference. Pass them on to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can become a choking or suffocation hazard (see Precautions and tips).
Fitting the appliance
The following precautions must be taken when installing the hob:
• Kitchen cabinets adjacent to the appliance and taller than the top of the
hob must be at least 600 mm from the edge of the hob.
• Hoods must be installed according to their relative installation instruction manuals and at a minimum distance of 650 mm from the hob (see gure).
• Place the wall cabinets adjacent to the hood at a minimum height of 420 mm from the hob (see gure).
If the hob is installed beneath a wall cabinet, the latter must be situated at a minimum of
600mm min.
700 mm above the hob.
GB
! The appliance must be installed by a qualied professional according to the
instructions provided. Incorrect installation may cause harm to people and animals or may damage property.
! This unit may be installed and used only in permanently ventilated rooms in accordance with current national regulations. The following requirements must be observed:
• The room must be equipped with an air extraction system that expels
any combustion fumes. This may consist of a hood or an electric fan that automatically starts each time the appliance is switched on.
In a chimney stack or branched flue. (exclusively for cooking appliances)
Directly to the Outside
• The room must also allow proper air circulation, as air is needed for combustion to occur normally. The ow of air must not be less than 2 m3/h
per kW of installed power.
The air circulation system may take air directly from the outside by means of a pipe with an inner cross section of at least 100 cm
2
; the
opening must not be vulnerable to any type
Examples of ventilation holes for comburant air.
A
of blockages.
650mm min.
420mm min.
Before the installation remove the grids and burners from the hob and turn it upside down, making sure you don’t damage the thermocouples and spark plugs.
Apply the seals that come with the appliance along the outer edges of the hob to prevent any passage of air, humidity and water (see Figure). For proper application make sure the surfaces to be sealed are clean, dry and free of any grease/oil.
• The installation cavity should have the dimensions indicated in the gure.
Fastening hooks are provided, allowing you to fasten the hob to tops that
are between 20 and 40 mm thick. To ensure the hob is securely fastened to the top, we recommend you use all the hooks provided.
Hook fastening diagram
Adjacent Room
Room to be Vented
The system can also provide the air needed for combustion indirectly, i.e. from adjacent rooms fitted with air circulation tubes as described above. However, these rooms must not be communal rooms, bedrooms or rooms
that may present a re hazard.
Enlarging the ventilation slot between window and floor.
• Liquid petroleum gas sinks to the oor as it is heavier than air. Therefore,
rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). It is advisable to keep only the cylinder being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens, replaces, stoves,
etc. ) which could raise the temperature of the cylinder above 50°C.
Hooking position for top H=20mm Hooking position for top H=30mm
Front
Hooking position for top H=40mm Back
! Use the hooks contained in the “accessory pack”.
7
• Where the hob is not installed over a built-in oven, a wooden panel must
GB
be installed as insulation. This must be placed at a minimum distance of 20 mm from the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet must be removed. It is advisable to install the oven so that it rests on two strips of
wood, or on a completely at surface with an opening of at least 45 x 560
mm (see diagrams).
! Once the appliance has been installed, the power supply cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by authorised technicians
only (see Assistance).
! The manufacturer declines any liability should these safety measures not be observed.
45 mm.
560 mm.
Where a hob is installed above an oven without a forced ventilation cooling system, adequate ventilation must be provided inside the cabinet by means
of air holes through which air can pass (see gure).
Electrical connection
Hobs equipped with a three-pole power supply cable are designed to operate with alternating current at the voltage and frequency indicated on the data plate (this is located on the lower part of the appliance). The earth wire in the cable has a green and yellow cover. If the appliance is to be installed above a built-in electric oven, the electrical connection of the hob and the oven must be carried out separately, both for electrical safety purposes and to make extracting the oven easier.
Gas connection
The appliance should be connected to the main gas supply or to a gas cylinder in compliance with current national regulations. Before carrying out the connection, make sure the cooker is compatible with the gas supply you wish to use. If this is not the case, follow the instructions indicated in the paragraph “Adapting to different types of gas.” When using liquid gas from a cylinder, install a pressure regulator which complies with current national regulations.
! Check that the pressure of the gas supply is consistent with the values indicated
in Table 1 (“Burner and nozzle specications”). This will ensure the safe operation and longevity of your appliance while maintaining efcient energy consumption.
Connection with a rigid pipe (copper or steel)
! Connection to the gas system must be carried out in such a way as not to place any strain of any kind on the appliance.
There is an adjustable L-shaped pipe tting on the appliance supply ramp and this is tted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe tting (seal provided with appliance). The gas supply pipe tting is a threaded 1/2 gas cylindrical male attachment.
Connecting a flexible jointless stainless steel pipe to a threaded attachment
The gas supply pipe tting is a threaded 1/2 gas cylindrical male attachment.
These pipes must be installed so that they are never longer than 2000 mm when fully extended. Once connection has been carried out, make sure that
the exible metal pipe does not touch any moving parts and is not compressed.
! Only use pipes and seals that comply with current national regulations.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data plate.
Checking the tightness of the connection
! When the installation process is complete, check the pipe ttings for leaks using a soapy solution. Never use a ame.
The appliance must be directly connected to the mains using an omnipolar circuit-breaker with a minimum contact opening of 3 mm installed between the appliance and the mains. The circuit-breaker must be suitable for the charge indicated and must comply with current electrical regulations (the earthing wire must not be interrupted by the circuit-breaker). The supply cable must not come into contact with surfaces with temperatures higher than 50°C.
Adapting to different types of gas
To adapt the hob to a different type of gas other than default type (indicated on the rating plate at the base of the hob or on the packaging), the burner nozzles should be replaced as follows:
1. Remove the hob grids and slide the burners off their seats.
2. Unscrew the nozzles using a 7 mm socket spanner, and replace them
! The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulations.
with nozzles for the new type of gas (see table 1 “Burner and nozzle characteristics”).
3. Reassemble the parts following the above procedure in the reverse order.
Before connecting to the power supply, make sure that:
• The appliance is earthed and the plug is compliant with the law.
• The socket can withstand the maximum power of the appliance, which is
4. Once this procedure is nished, replace the old rating sticker with one
indicating the new type of gas used. Sticker are available from any of our Service Centres.
indicated on the data plate.
• The voltage is in the range between the values indicated on the data plate.
• The socket is compatible with the plug of the appliance. If the socket is
incompatible with the plug, ask an authorised technician to replace it. Do
Replacing the nozzles on separate “double ame “ burners
1. Remove the grids and slide the burners from their housings. The burner
consists of 2 separate parts (see gure);
not use extension cords or multiple sockets.
8
2. Unscrew the burers with a 7 mm wrench spanner. The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1).
! Should the gas pressure used be different (or vary slightly) from the
recommended pressure, a suitable pressure regulator must be tted to the
inlet pipe (in order to comply with current national regulations).
3. Replace all the components by repeating the steps in reverse order.
DATA PLATE Electrical
connections
• Adjusting the burners’ primary air
Does not require adjusting.
• Setting the burners to minimum
1. Turn the tap to the low ame position;
2. Remove the knob and adjust the adjustment screw, which is positioned
in or next to the tap pin, until the ame is small but steady.
! In the event of single-control DRDA (DCDR) burners, adjustment can be performed by intervening on the 2 screws located near the tap pin (see picture).
Total DRDA (DCDR) burner adjustment
GB
see data plate
This appliance conforms to the following European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04 (Electromagnetic Compatibility) and subsequent amendments
- 93/68/EEC dated 22/07/93 and subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and subsequent amendments.
- 2012/19/EC and subsequent amendments.
Inner DRDA (DCDR) burner adjustment
3. Having adjusted the ame to the required low setting, while the burner is
alight, quickly change the position of the knob from minimum to maximum
and vice versa several times, checking that the ame does not go out.
4. Some appliances have a safety device (thermocouple) tted. If the device fails to work when the burners are set to the low ame setting, increase this low ame setting using the adjusting screw.
5. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.
6. In the event of discrete-adjustment knobs with LED visualisation, turn the
knob to the minimum power setting them remove it and intervene on the adjustment screw located near the tap pin.
7. Minimum setting adjustment of the DRDA (DCDR) burner with discrete
adjustment and LED visualisation:
• To adjust the outer ring, turn the knob anti-clockwise to the minimum
power position.
• To adjust the minimum power setting of the inner ring, turn the knob
clockwise to the minimum power position.
• Remove the knob and intervene on the adjustment screw located near
the tap pin.
! If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.
! Once this procedure is nished, replace the old rating sticker with one
indicating the new type of gas used. Stickers are available from any of our Service Centres.
9
GB
PK 640 RL GH AG
Burner and nozzle specifications (for 65 cm versions only)
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow* power power 1/100 1/100 (g/h) power 1/100 (l/h) kW kW kW (p.c.s.*) (p.c.s.*) (p.c.s.*) (mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
Reduced Fast (RR)
100
0.70
2.60
39
80
189
186
2.60
122 (H3)
248
Semi Fast (S)
Auxiliary (A)
Double flame (DCDR internal) (1)
Double flame (1)
Supply pressures Nominal (mbar)
(1) For single-control DRDA (DCDR) burner only * At 15°C and 1013,25 mbar - dry gas ** Propane P.C.S. = 50.37 MJ/Kg *** Butane P. C.S. = 49.47 MJ/Kg Natural P.C.S. = 37.78 MJ/m³
(DCDR internal)
(DCDR external
2 nozzle)
75
55
36
130
0.40
0.40
0.30
1.50
1.65
1.00
0.90
3.60
Minimum (mbar) Maximum (mbar)
A
28
28
29
29
57
64
50
44
44
60x2
120
73
65
262
28-30
20 35
118
71
64
257
37 25 45
1.65
1.00
0.90
3.60
96 (Z)
79 (6)
74
74
94x2
20 17 25
157
95
86
343
RR
DC
S
10
PK750RL GH AG
PK760RF GH AG
Table 1 Liquid Gas Natural Gas
Burner and nozzle specifications (for 75 cm versions only)
Burner Diameter Thermal Thermal By-pass Nozzle Flow* Thermal Nozzle Flow* power power 1/100 1/100 (g/h) power 1/100 (l/h) kW kW kW (p.c.s.*) (p.c.s.*) (p.c.s.*) (mm) Reduced Nominal (mm) (mm) *** ** Nominal (mm)
GB
Reduced Fast (RR)
Semi Fast (S)
Auxiliary (A)
Semi-Fishburner (SP)
Double Flame (DCDR Internal) (2)
Double Flame (DCDR External) 2 nozzle (2)
Double flame (DCDR internal) (1)
(DCDR
Double flame (1)
Supply pressures Nominal (mbar)
(1) For single-control DRDA (DCDR) burner only (2) For dual-control DRDA (DCDR) burner only
* At 15°C and 1013,25 mbar - dry gas ** Propane P.C.S. = 50.37 MJ/Kg *** Butane P. C.S. = 49.47 MJ/Kg Natural P. C.S. = 37.78 MJ/m³
internal)
(DCDR external
2 nozzles)
100
75
55
36
130
36
130
0.70
0.40
0.40
0.70
0.40
1.50
0.30
1.50
Minimum (mbar) Maximum (mbar)
2.60
1.65
1.00
1.50
0.90
4.10
0.90
4.60
39
28
28
39
28
61
29
29
57
80
64
50
60
44
70x2
44
44
60x2
189
120
73
109
65
298
65
334
28-30
20 35
186
118
71
107
64
293
64
329
37 25 45
2.60
1.65
1.00
1.50
0.90
4.10
0.90
5.00
122 (H3)
96 (Z)
79 (6)
88 (X)
74
110x2
74
74
94x2
20 17 25
248
157
95
143
86
390
86
476
RR
A
DC SP
RR
A
DC
S
S
S
DC
A
PK741RQO GH AG
11
Loading...
+ 25 hidden pages