SAFETY INSTRUCTIONS
EN
IMPORTANT TO BE READ AND OBSERVED
Download the complete instruction manual www. aristonchannel.com or call the phone number
shown on the warranty booklet
Before using the appliance, read these safety instructions. Keep them nearby for future reference. These instructions and the appliance itself provide important safety warnings, to be observed at all times. The manufacturer declines any liability for failure to observe these safety instructions, for inappropriate use of the appliance or incorrect setting of controls.
These instructions are valid if the country symbol appears on the appliance. If the symbol doesn’t appear on the appliance, it is necessary to refer to the technical instructions which will provide the necessary instructions concerning modication of the appliance to the conditions of use of the country.
CAUTION : The use of the gas cooking appliance results in the production of heat, moisture and products of combustion in the room in which it is installed. Ensure that the kitchen is well ventilated especially when the appliance is in use: keep natural ventilation holes open or install a mechanical ventilation device (mechanical extractor hood). Prolonged intensive use of the appliance may call for additional ventilation, for example opening of the window, or more eective ventilation,increasing the level of mechanical ventilation where present.
WARNING: The appliance and its accessible parts become hot during use. Care should be taken to avoid touching heating elements. Children less than 8 years of age must be kept away unless continuously supervised.
WARNING : If the hob surface is cracked, don’t use the appliance – risk of electrical shock.
WARNING : Danger of re : Do not store items on the cooking surfaces.
CAUTION : The cooking process has to be supervised. A short cooking process has to be supervised continuously.
WARNING : Unattended cooking on a hob with fat or oil can be dangerous – risk of re. NEVER try to extinguish a re with water, but switch o the appliance and then cover ame e.g. with a lid or a re blanket.
Do not use the hob as a work surface or support. Keep clothes or other ammable materials away from the appliance, until all the components have cooled down completely – risk of re.
If the information in this manual is not followed exactly, a re or explosion , may result causing property damage or injury.
Very young children (0-3 years) should be kept away from the appliance. Young children (3-8 years) should be kept away from the appliance unless
continuously supervised. Children from 8 years old and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children without supervision.
CAUTION : In case of hotplate glass breakage:-shut immediately o all burners and any electrical heating element and isolate the appliance from the power supply; - do not touch the appliance surface; -do not use the appliance. The glass lid can break in if it is heated up. Turn o all the burners and the electric plates before closing the lid. Do not shout down lid when burner alight.
PERMITTED USE
CAUTION: the appliance is not intended to be operated by means of an external switching device, such as a timer, or separate remote controlled system.
This appliance is intended to be used in household and similar applications such as: sta kitchen areas in shops, oces and other working environments; farm houses; by clients in hotels, motels, bed & breakfast and other residential environments.
No other use is permitted (e.g. heating rooms).
This appliance is not for professional use. Do not use the appliance outdoors.
Use pots and pans with bottoms the same width as that of the burners or slightly larger (see specic table). Make sure pots on the grates do not protrude beyond the edge of the hob.
Improper use of the grids can result in damage to the hob: do not position the grids upside down or slide them across the hob.
Do not let the burner ame extend beyond the edge of the pan. Do not use : Cast iron griddles, collar stones, terracotta pots and pans. Heat diusers such as metal mesh, or any other types. Two burners simultaneously for one receptacle (e.g. Fish kettle). Should particular local conditions of the delivered gas make the ignition of burner dicult, it is advisable to repeat the operation with the knob turned to small ame setting. In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct distance. The protective rubber feet on the grids represent a chocking hazard for young children. After removing the grids, please ensure that all the feet are correctly tted.
INSTALLATION
The appliance must be handled and installed by two or more persons - risk of injury. Use protective gloves to unpack and install - risk of cuts.
Installation, including water supply (if any) and electrical connections, and repairs must be carried out by a qualied technician. Do not repair or replace any part of the appliance unless specically stated in the user manual. Keep children away from the installation site. After unpacking the appliance, make
sure that it has not been damaged during transport. In the event of problems, contact the dealer or your nearest After-sales Service. Once installed, packaging waste (plastic, Styrofoam parts etc.) must be stored out of reach of children - risk of suocation. The appliance must be disconnected from the power supply before any installation operation - risk of electrical shock. During installation, make sure the appliance does not damage the power cable - risk of re or electrical shock. Only activate the appliance when the installation has been completed.
The electrical and gas connections must comply
with local regulation.
WARNING : Modication of the appliance and its method of installation are essential in order to use the appliance safely and correctly in all the additional countries.
Use pressure regulators suitable for the gas pressure indicated in the instruction.
The room must be equipped with an air extraction system that expels any combustion fumes.
The room must also allow proper air circulation, as air is needed for combustion to occur normally. The ow of air must not be less than 2 m3/h per kW of installed power.
The air circulation system may take air directly from the outside by means of a pipe with an inner cross section of at least 100 cm2; the opening must not be vulnerable to any type of blockages.
The system can also provide the air needed for combustion indirectly, i.e. from adjacent rooms tted with air circulation tubes as described above. However, these rooms must not be communal rooms, bedrooms or rooms that may present a re hazard.
Liquid petroleum gas sinks to the oor as it is heavier than air. Therefore, rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc.). It is advisable to keep only the cylinder being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, replaces, stoves, etc. ) which could raise the temperature of the cylinder above 50°C.
Carry out all cabinet cutting works before tting the appliance in the furniture and remove all wood chips and sawdust.
If the appliance is Not installed above an oven, a separator panel (not included) must be installed in the compartment under the appliance.
Should you experience diculty in turning the burners knobs, please contact After Sales Service for replacement of the burner tap if found to be fault y. The openings used for the ventilation and dispersion of heat must never be covered.
GAS CONNECTION
WARNING : Prior to installation, ensure that the local distribution conditions (nature of gas and gas pressure) and the adjustment of the appliance are compatible.
Check that the pressure of the gas supply is consistent with the values indicated in Table 1 (“Burner and nozzle specications”).
WARNING : The adjustment conditions for this appliance are stated on the label (or data plate).
WARNING : This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.
If the appliances is connected to liquid gas, the regulation screw must be fastened as tightly as possible.
IMPORTANT : When gas cylinder is adopted, the gas cylinder or gas container must be properly settled (vertical orientation).
WARNING : This operation must be performed by a qualied technician
Use only exible or rigid metal hose for gas connection.
Connection with a rigid pipe (copper or steel) Connection to the gas system must be carried out in such a way as not to place any strain of any kind on the appliance. There is an adjustable L-shaped pipe tting on the appliance supply ramp and this is tted with a seal in order to prevent leaks. The seal must always be replaced after rotating the pipe tting (the seal is provided with the appliance). The gas supply pipe tting is a threaded 1/2 gas cylindrical male attachment.
Connecting a exible joint less stainless steel pipe to a threaded attachment The gas supply pipe tting is a threaded 1/2 gas cylindrical male attachment. These pipes must be installed so that they are never longer than 2000 mm when fully extended. Once connection has been carried out, make sure that the exible metal pipe does not touch any moving parts and is not compressed. Only use pipes and seals that comply with current National regulations.
IMPORTANT : If a stainless steel hose is used, it must be installed so as not touch any mobile part of the furniture (e.g. drawer). It must pass through an area where there are no obstructions and where it is possible to inspect it on all its length.
The appliance should be connected to the main gas supply or to gas cylinder in compliance with the current National regulations. Before carry out the connection, make sure that the appliance is compatible with the gas supply you wish to use. If this is not the case, follow the instructions indicated in the paragraph “Adapting to dierent types of gas”.
After connection to the gas supply, check for leaks with soapy water. Light up the burners and turn the knobs from max position 1* to minimum position 2* to check ame stability.
ADAPTING TO DIFFERENT TYPES OF GAS
In order to adapt the appliance to a type of gas other than the type for which it was manufactured (indicated on the rating label), follow the dedicated steps provided after installation drawings.
ELECTRICAL WARNINGS
IMPORTANT: The data relevant to the voltage an power absorptions are indicated on the rating plate.
The power cable must be long enough to connect the appliance, once tted in its housing, to the main power supply. Do not pull the power supply cable.
It must be possible to disconnect the appliance from the power supply by unplugging it if plug is accessible, or by a multi-pole switch installed upstream of the socket in accordance with the wiring rules and the appliance must be earthed in conformity with national electrical safety standards.
Do not use extension leads, multiple sockets or adapters. The electrical components must not be accessible to the user after installation. Do not use the appliance when you are wet or barefoot. Do not operate this appliance if it has a damaged power cable or plug, if it is not working properly, or if it has been damaged or dropped.
If the supply cord is damaged, it must be replaced with an identical one by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard - risk of electrical shock.
CLEANING AND MAINTENANCE
WARNING: Ensure that the appliance is switched o and disconnected from the power supply before performing any maintenance operation; never use steam cleaning equipment - risk of electric shock.
Do not use abrasive or corrosive products, chlorine-based cleaners or pan scourers.
DISPOSAL OF PACKAGING MATERIALS
The packaging material is 100% recyclable and is marked with the recycle symbol . The various parts of the packaging must therefore be disposed of responsibly and in full compliance with local authority regulations governing waste disposal.
DISPOSAL OF HOUSEHOLD APPLIANCES
This appliance is manufactured with recyclable or reusable materials. Dispose of it in accordance with local waste disposal regulations. For further information on the treatment, recovery and recycling of household electrical appliances, contact your local authority, the collection service for household waste or the store where you purchased the appliance. This appliance is marked in compliance with European Directive 2012/19/EU, Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent negative consequences for the environment and human health.
The symbol on the product or on the accompanying documentation indicates that it should not be treated as domestic waste but must be taken to an appropriate collection center for the recycling of electrical and electronic equipment.
ENERGY SAVING TIPS
Use pots and pans with bottom width equal to that of the cooking zone. Only use at-bottomed pots and pans. When possible, keep pot lids on during cooking. Use a pressure cooker to save even more energy and time. Place the pot in the middle of the cooking zone marked on the hob.
DECLARATION OF CONFORMITY
This appliance meets the Ecodesign requirements set out in European Regulation n.66/2014, in conformity to the European standard EN 30-2-1.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used
NATURAL GAS (Methane) G20
LIQUEFIED PETROLEUM GAS (Butane) G30
LIQUEFIED PETROLEUM GAS (Propane) G31
Type of gas used Model conguration
G20 20 mbar 1RR - 1SR - 1AUX - 1TC 8,50 809 l/h 9,52 G30 28-30 mbar 1RR - 1SR - 1AUX - 1TC 8,50 618 g /h 30,94 G31 37 mbar 1RR - 1SR - 1AUX - 1TC 8,50 607 g/h 23,80
Type of burner Injector
marking
Reduced Rapid Semi-rapid Auxiliary Triple Crown
Reduced Rapid Semi-rapid Auxiliary Triple Crown
Reduced Rapid Semi-rapid Auxiliary Triple Crown
4 BURNERS
110 (Y )
96 (Z) 71 (X)
133 (Z)
80 64 50 91
80 64 50 91
Rated thermal
ow rate
kW
2,60 1,65 1,0 0 3,25
2,60 1,65 1,0 0 3,25
2,60 1,65 1,0 0 3,25
Rated thermal
owrate (kW)
Rated
consumption
248 l/h 157 l/h
95 l/h
309 l/h
189 g/h 120 g/h
73 g/h
236 g/h
186 g/ h 118 g/ h
71 g/h
232 g/h
Total rated
consumption
Reduced heat
capacity
kW
0,70 0,40 0,40 1,50
0,70 0,40 0,40 1,50
0,70 0,40 0,40 1,50
Gas pressure
mbar
min. rat. max.
17 20 25
20 28-30 35
25 37 45
Air required (m) for
burning 1m of gas
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 900W
Loading...
+ 4 hidden pages