1 DESCRIPTION OF THE UNIT

Fig. 1

BRAVO M_U-PV1

3

 

2

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Water Inlet

4

Filter

2

Water Outlet

5

External Valve

3

Power Indicator Light for Heating Element(s)

 

 

 

 

 

 

2 TECHNICAL SPECIFICATIONS

For the technical specifications, refer to the rating plate.

Power

 

kW

3 / 3.3 / 3.6

 

4.1 / 4.5 / 4.9

Voltage

 

V

220 / 230 / 240

 

220 / 230 / 240

Current

 

A

13.7 / 14.4 / 15

 

18.7 / 20 / 20.4

Delivery Pressure

Minimum

kPa

10 kPa / 1.45

psi / 0.1 bar

Frequency

 

Hz

 

50 - 60

Operating Range

Minimum

l/min

 

2

 

Maximum

l/min

 

8

Weight (kg)

 

kg

 

3.1

Dimensions: height x depth x width

mm

340 x 101 x 225

1 bar = 10 N/cm2 = 100 kPa = 14.5 psi

 

 

 

 

3 GENERAL NOTICES

National standards and codes may include restrictions on installing appliances in bathrooms. Installation is the responsibility of the purchaser. The Merloni TermoSanitari S.p.a. company will not be held liable for damages caused by incorrect installation and/or the failure to comply with the instructions contained in this manual. In particular:

The electrical connection must comply with the specifications set forth in the relative paragraph.

The unit must be installed by a qualified technician.

4 INSTALLATION

The installation of the unit must comply with national codes, standards, and regulations currently in effect.

Remove the cover, which is fastened at the bottom with screw.

When remounting the knobs, pay attention to the position of the knobs. The applicance must be installed on the wall, using the screws (A) and the wall anchors (B) provided with the unit.

Fig. 2

B

A

Rating Plate

Water Connection

Connect the inlet pipe for the appliance (C - blue) to cold water pipe from the mains, using a flexible 1/2" hose.

If the static pressure in the mains is greater than 500 kPa (5 bar), mount a pressure reduction valve.

The appliance drains freely and, therefore, the outlet pipe (D) must always remain open. Clogging could seriously damage the water heater.

The appliance is built to operate exclusively with the hand shower provided.

When making the connection, do not tighten the connectors excessively. Use rubber gasket provided, do not use seal tape on the thread.