ARI Armaturen EURO-WEDI User Manual

Operating and installation instructions
Stop valve with soft seal EURO-WEDI
®
Contents
1.0 General information on operating
instructions ....................................................2
2.0 Notes on possible dangers........................... 2
2.2 Explanatory notes on safety information .................2
3.0 Storage and transport .................................. 2
4.0 Description.....................................................3
4.1 Scope of applications ..............................................3
4.2 Operating principles ................................................3
4.3 Diagram...................................................................4
4.4 Technical data - remarks.........................................5
4.5 Marking ...................................................................5
5.0 Installation......................................................5
5.1 General notes on installation...................................5
Rev. 0040104000 0410 englisch
6.0 Putting the valve into operation .................. 6
7.0 Care and maintenance.................................. 7
7.1 Hood valve ............................................................ 7
8.0 Troubleshooting ............................................ 8
9.0 Troubleshooting table ................................. 8
10.0 Dismantling the valve or the top part ....... 9
11.0 Warranty / Guarantee .................................. 9
12.0 EC declaration of conformity................... 10
Operating and installation instructions
EURO-WEDI

1.0 General information on operating instructions

These operating instructions provide information on mounting and maintaining the fittings. Please contact the supplier or the manufacturer in case of problems which cannot be solved by reference to the operating instructions.
They are binding on the transport, storage, installation, start-up, operation, maintenance and repair. The notes and warnings must be observed and adhered to.
- Handling and all work must be carried out by expert personnel or all activities must be supervised and checked.
It is the owner’s responsibility to define areas of responsibility and competence and to monitor the personnel.
- In addition, current regional safety requirements must be applied and observed when taking the fittings out of service as well as when maintaining and repairing them.
The manufacturer reserves the right to introduce technical modifications at any time. These Operating Instructions comply with the requirements of EU Directives.

2.0 Notes on possible dangers

®

2.1 Significance of symbols

ATTENTION !
. . .
Warning of general danger.

2.2 Explanatory notes on safety information

In these Operating and Installation Instructions dangers, risks and items of safety information are highlighted to attract special attention.
Information marked with the above symbol and “ATTENTION!” describe practices, a failure to comply with which can result in serious injury or danger of death for users or third parties or in material damage to the system or the environment. It is vital to comply with these practices and to monitor compliance.
All other information not specifically emphasised such as transport, installation, operating and maintenance instructions as well as technical data (in the operating instructions, product documentation and on the device itself) must also be complied with to the fullest extent in order to avoid faults which in turn can cause serious injury to persons or damage to property.

3.0 Storage and transport

ATTENTION !
- Protect against external force (like impact, vibration, etc.).
- Valve mountings such as actuators, handwheels, hoods must not be used to take external forces, e.g. they are not designed for use as climbing aids, or as connecting points for lifting gear.
- Suitable materials handling and lifting equipment should be used. See catalog sheet for weights.
- At -20°C to +65°C.
- The paint is a base coat to protect against corrosion during transportation and storage. Do not damage paint protection.
Page 2 Rev. 0040104000 0410
Operating and installation instructions
EURO-WEDI

4.0 Description

4.1 Scope of applications

Valves are used for „shut-off and/or throttling of media“.
ATTENTION !
- Refer to the data sheet for applications, limits on use and possibilities.
- Certain media require or preclude the use of special materials.
- The valves are designed for standard operating conditions. If conditions exceed these requirements, e.g. aggressive or abrasive media, the operator should state the higher requirements when ordering.
- Valves made from grey cast iron are not authorised for use in systems subject to TRD 110.
The information complies to the Pressure Equipment Directive 97/23/EC. It is the responsibility of the machine planner to ensure compliance. The special markings on the valve must be taken into account.
Refer to the catalogue sheet to see which materials are used in standard versions.
®
Please contact the supplier or the manufacturer if you have any questions.

4.2 Operating principles

The valve is closed by turning the hand wheel clockwise (cone/seat function). Do not use tools to increase the torque on the hand wheel. The valve spindle is sealed by an EDD (flexible double seal system).
EURO-WEDI seals in the "open" state are protected against accidental closing by a protective cap.
Rev. 0040104000 0410 Page 3