ARAG Alfa 310 User Manual

Quick reference guide
Job Control:
Seed spacing alarm:
Working width:
Seeds weight (100):
Sensors efficiency: Speed sensor: Load/save settings:
User Preferences: Test:
New Job:
Resume Job:
Minimum tolerance:
Maximum tolerance:
User menu
Shift cursor to the next digit
Confirm entered value
19.8
1
38
rpm
Edit digit highlighted by cursor
Quit without confirming
Esc
value and/or go back to previous menu
1
s/m
2
2
7.84
Seed sensor 1 ! clogged
3
ha
5.8
4:36
Max
km/h
4
hh:mm
Reset displayed value
Esc
0 1.00
Seeds per meter
0 50.0
s/m
Display average seeding value for the machine
or the value for the selected row
Display current or top speed
Select the seed row
Activate sensor
reading
1
Activated row
Deactivate sensor
reading
1
Deactivated row
When sensor is deactivated, the monitor does not show data for the corresponding row.
Maximum value:
Minimum value:
500.0
0.1
s/m
s/m
Scroll values displayed next to pressed key
10 9 8
7
12 3
1
19.8
s/m
1
2
5.8
3
x x
2
38
rpm
Job : Job3
Rev. sensor1!Norotation
7.84
4:36
ha
1
3a
Max
km/h
4
4a
4
4b 4c
x
4d
4e
4
5
cm
rpm
rpm
ha/h
hh:mm
5a
5b
5c
5d
5e
hh:mm
12:01
6
2.2 38 24
1.8
1
Number of seeds per meter: average value or per row
2
Selected seed row: press / to change
3
Machine speed or top speed reached during current job Maximum speed indicator
3a 4
Chart showing seeding rate deviation from setting
4a
Seed row number
4b
Seed spacing maximum tolerance
4c
Seed spacing deviation
4d
Seed spacing minimum tolerance
Double fertilization enabled (sensor A + B)
4e
x
Single fertilization enabled (sensor A)
x
Single fertilization enabled (sensor B)
Work data
5
Seed spacing
5a
Rotation speed, rev counter 1
5b
Rotation speed, rev counter 2
5c
Performance
5d
Work time
5e
Time
6
Alarms
7
Name of current job
8
Work area
9
Selected rev counter
10
Seed sensor XX! No signal
Rev. sensor X! No signal
Speed sensor! No signal
Position sensor! No signal
Shaft sensor XX! No signal
seeding exceeding max. limit
seeding below min. limit
Row XX: seeding exceeding max. limit
Row XX: seeding below min. limit
Row XX: Seeding tube clogged
Row XX: no seeding
Impeller X! Speed too high
Impeller X! Speed too low
SD card not available
SD card writing locked out
Rev. sensor1!Norotation
- Alfa 310 is not receiving the signal from seed sensor on line XX
- Alfa 310 is not receiving the signal from rev. sensor X
- Alfa 310 is not receiving the signal from speed sensor
- Alfa 310 is not receiving the signal from seed state sensor
- Alfa 310 is not receiving the signal from shaft Rev. sensor XX
- Number of seeds per metre exceeds maximum set value
- Number of seeds per metre is below minimum set value
- Number of seeds per metre on seed row XX exceeds maximum set value
- Number of seeds per metre on seed row XX is below minimum set value
- Seeding tube is clogged or seed sensor for row XX has low efficiency
- Seeds are not detected on row XX
- Impeller X speed exceeds maximum set value
- Impeller X speed is below minimum set value
- Memory card is not inserted
- Memory card writing locked out
Impossible to save the file
Slow down! Maximum speed reached
Row XX: no fertiliz. (A)
Row XX: no fertiliz. (B)
Row XX: Fertilizer tube clogged (A)
Row XX: Fertilizer tube clogged (B)
Shaft XX: No rotation
via Palladio, 5/A - 42048 RUBIERA (RE) - Italy - tel. + 39 0522 622011 - Fax +39 0522 628944 - www.aragnet.com Cod. D20198_GB-m00
- No space available or damaged memory card
- Vehicle speed exceeds maximum set value
- Fertilizer A is not detected on row XX
- Fertilizer B is not detected on row XX
- Seeding tube is clogged or fertilizer sensor A for row XX has low efficiency
- Seeding tube is clogged or fertilizer sensor B for row XX has low efficiency
- No rotation of shaft XX is detected
Loading...