Aprilaire 850 Installation & Maintenance Instructions Manual

Model 850 Steam Humidifier Fan Pack
Model 850 Steam Humidifier Fan Pack
TABLE OF CONTENTS
Safety Cautions..........................................2
Materials List ...........................................2
Operation ...............................................3
Specifications & Dimensions .............................3
Installation Instructions
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mount Housing .........................................5
Hose Connections .......................................5
Electrical Wiring ........................................6
Grille Installation ........................................6
Start-up Procedure ......................................7
Maintenance............................................7
Troubleshooting Guide ...................................7
Replacement Parts.......................................8
Limited Warranty ........................................8
READ AND SAVE THESE INSTRUCTIONS
SAFETY CAUTIONS
CAUTION
ATTENTION INSTALLER
Read this manual before installing. This product must be installed by a qualified HVAC contractor and in compliance with local, state, federal, and governing codes. Improper installation can cause property damage, severe personal injury, or death as a result of electric shock, burns, or fire.
Read all cautions and instructions.
Read this manual before performing service or maintenance procedures on any part of the system. Failure to follow all cautions and instructions could produce the hazardous situations described, resulting in property damage, personal injury, or death.
Failure to follow the instructions in this manual can cause moisture to accumulate, which can cause damage to structure and furnishings.
HOT SURFACES AND HOT WATER
This steam humidification system has extremely hot surfaces. Steam pipes, and dispersion chamber can be as hot as 212°F (100°C). Discharged steam is not always visible. Contact with hot surfaces, discharged hot water, or air into which steam has been discharged can cause severe personal injury. To avoid severe burns, follow procedures in this manual when performing service or maintenance procedures on any part of the system.
DISCONNECT ELECTRICAL POWER
Disconnect electrical power before installing supply wiring or performing service or maintenance procedures on any part of the humidification system. Failure to disconnect electrical power could result in fire, electrical shock, and other hazardous conditions. These hazardous conditions could cause property damage, personal injury, or death.
Contact with energized circuits can cause property damage, severe personal injury, or death as a result of electrical shock or fire. Do not remove access panels until electrical power is disconnected.
Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system.
ELECTRICAL SHOCK HAZARD
If the humidifier starts up responding to a call for humidity during maintenance, severe bodily injury or death from electrical shock could occur. Follow the procedures in this manual before performing service or maintenance procedures on the humidifier system.
SHARP EDGES
Sharp edges may cause serious injury from cuts. Use care when cutting openings and handling housing and grille.
EXCESS HUMIDITY
Do not operate humidifier if blower is not operating. Do not place objects in front of steam discharge. Condensation may cause damage.
MATERIALS LIST
MATERIALS FURNISHED NOT FURNISHED
Model 850 Fan Pack
Manual humidistat
4 housing mounting screws
2 wire ties
2 grille mounting screws
Neoprene condensation tubing – 3/8” ID, 10’
Steam hose – 6’ steam hose provided with the Model 800 humidifier
Steam hose clamp – provided with the Model 800 humidifier
Wire for humidistat and wire to power Model 850 Fan Pack
2
OPERATION
17-1/16
6-7/8
6-1/16 7-1/16
5
14
Fan Inlet
Fan Outlet
Steam Dispersion Manifold
3/8
7-13/16
4-3/4
16" Minimum
for Steam Hose
30" Recommended
for Service Access
IMPORTANT:
Loop drain hose below Model 850 to provide trap.
Drain
On a call for humidity the Model 800 Residential Steam Humidifier provides power to the Model 850 Fan Pack. The Model 850 blower distributes the steam to the room. When the call for humidity ends and the humidifier stops producing steam, the Model 850 Fan Pack will continue to operate for 2 minutes to distribute the remaining steam before de-activating.
SPECIFICATIONS & DIMENSIONS
TECHNICAL SPECIFICATIONS
• 24 VAC supplied by Model 800 humidifier
• Stainless steel steam dispersion chamber
• Noise dampening housing liner
• Ultra quiet fan
INSTALLATION INSTRUCTIONS
LOCATION
DIMENSIONS
FIGURE 1 – Dimensions of the Model 850
90-1554
The Model 850 must be located near the Model 800 Residential Steam Humidifier to minimize the length of the steam hose. If the
Model 850 is mounted directly above the humidifier, 16” is required
for the steam hose to make the bend. See Figure 2. NOTE: The loop
in the condensate hose is required to prevent steam from escaping
into the drain.
FIGURE 2 – Side View
90-1551
3
Loading...