Aprilaire 700, 700m User Manual

FURNACE
BLOWER MOTOR
24 VAC FURNACE ACCESSORY
TERMINALS OR TRANSFORMER
(10VA MINIMUM)
MODEL 50
CURRENT SENSING RELAY
SHUT-OFF
(SADDLE VALVE)
WATER SUPPLY
IMPORTANT
USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.
IMPORTANT
WHEN MODEL 50 CURRENT SENSING RELAY IS USED:
BROWN WIRES
120 VAC OUTLET
• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.
• WIRE MODEL 50 CURRENT SENSING RELAY INTO 24 VAC HUMIDIFIER CONTROL CIRCUIT ONLY! DO NOT INSTALL IN TRANSFORMER
PRIMARY CIRCUIT.
COMMON
HI
LO
CONNECT DRAIN LINE HERE
G
Y
W
C
R
THERMOSTAT
R
C
W
Y
G
FURNACE
120 VAC OUTLET
BROWN WIRES
CONNECT DRAIN LINE HERE
110 VAC
CONNECT TO HOT WATER SUPPLY
OUTDOOR
TEMPERATURE
SENSOR FOR
AUTOMATIC MODE
NORTH, EAST
OR WEST SIDE
OF HOME
ABOVE EXPECTED
SNOW LINE
CONTINUOUSLY POWERED 24 VAC
TRANSFORMER PROVIDED WITH HUMIDIFIER
OUTPUTSINPUTSPOWER
GW
CRHHODT GfA
A
DHC TERMINAL STRIP
B
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEM PLATE BEFORE STARTING INSTALLATION
ATTENTION INSTALLER:
his product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.
T
This product must be installed in compliance with all local, state and federal codes.
Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.
MODEL 700 SERIES HUMIDIFIER
WARNING
1. ELECTRICAL SHOCK HAZARD.
Disconnect electrical power to the furnace before starting installation.
ailure to do so could result in serious
F injury from electrical shock.
2.
SHARP EDGES HAZARD. Sharp
edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.
3.
RISK OF SCALDING. Water
temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.
RISK OF PROPERTY AND EQUIPMENT DAMAGE.
1. Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.
. Do not install humidifier on the furnace jacket.
2
3. Do not install humidifier on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.
4. Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.
CAUTION
5. Do not connect the Model 700 or 700M power cord to multi­speed furnace blower motors or blower motors other than 120 VAC. Premature component failure may result. Use Research
roducts Corporation Model 50 Current Sensing Relay.
P
6. When installing Humidifier Control on a downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control.
7. Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.
8. Do not install humidifier on the supply plenum where static pressure exceeds 0.4 in. wg.
RECOMMENDED WIRING DIAGRAMS
(SEE STEP 6 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)
Model 700
DIGITAL HUMIDIFIER CONTROL
SPECIFICATIONS
HUMIDIFIER DIMENSIONS
W
32
29
idth 15
Height (including solenoid valve
and drain spud)
Depth 10
18”
11
32
PLENUM OPENING
3
14
4”W x 145⁄16”H
WATER FEED RATE
6 gph
ELECTRICAL DATA
120 VAC-60 Hz, 0.8 AMP
INSTALLATION OPTIONS
Typical Installation Alternate Installation
RETURN
SUPPLY
HOT WATER
RETURN
SUPPLY
Model 700M
MANUAL CONTROL
90-1514
Orientation of Aprilaire Model 700
and 700M to Cooling Coils
90-1208
RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357
Aprilaire to be installed as shown in relation to cooling coils.
COOLING COILS IN
WARM AIR PLENUM
BLANKED OFF
END OF COIL
90-921
NOTES
1. Models 700 and 700M are not suitable for installation on ducts with horizontal airflow. Performance will be reduced.
2. When installing the Aprilaire humidifier with the Aprilaire Digital Humidifier Control or on a heat pump system, use hot water. The heated water supplements the reduced supply air temperature as added heat for evaporation.
90-922
READ REVERSE SIDE FIRST! READ REVERSE SIDE FIRST!
6
7
12
5
2
3
1
16
4
18
9
14
11
10
8
13
15
17
TOP
READ COMPLETE SAF ETY INSTR UCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION
URNISHED ITEMS
F
24 VAC Transformer
Digital Humidifier Control
(Model 700 only)
Manual Humidifier Control
(Model 700M only)
Humidifier Control
Installation Instructions
Saddle Valve
Humidifier Installation Template
Figure 1
Figure 2 Figure 3 Figure 4
ITEMS NOT FURNISHED
Mounting screws
(sheet metal screws)
Water supply line (1⁄4” copper)
Drain line (1⁄2” I.D. hose)
Low voltage wire
Model 50 Current Sensing Relay
1. Detach the cover assembly by
lifting the latch at the bottom. Remove the Water Panel evaporator assembly by grasping at top and tipping out. See Figure 1.
2. Position template on supply
plenum. Make sure template is level. Allow clearance for drain line and for servicing. See “Installation Options” on opposite side for position relative to cooling coil.
(if required)
90-923 90-924 90-925 90-926
Trace template outline. Cut 14-3/4” wide x 14-5/16” high opening. Avoid
®
injury from sharp edges.
3. Position base (2) in duct opening
top-first so hooks engage sheet metal at top. See Figure 2. Insert bottom of base and slide down to engage hooks at bottom.
4. Rotate swing locks to secure base
to duct. See Figure 3. Fasten base to duct using 4 sheet metal screws in holes provided.
5. Insert Water Panel Evaporator
assembly into base. Make sure bottom of scale control insert (5) is over drain opening. Snap top of evaporator assembly into base.
6. Control installation and wiring.
Disconnect electrical power to furnace before wiring control. In order for
humidifier to operate, furnace must be on and RH must be below set-point of control. Wiring diagrams illustrate recommended method of detecting furnace operation.
PARTS LIST
1. Front Cover
2. Base
3. Orifice Plate
4. Motor Mount Bridge
5. Scale Control Insert
6. Water Panel Evaporator
7. Water Distribution Tray
8. Fan Blade
9. Motor
10. Motor Mount Gasket
11. Control Relay
12. Power Cord
13. Strain Relief Bushing
14. Solenoid Valve
15. Connector Plug
16. Feed Tube
17. Nozzle
18. Relay Connector Plug
MANUAL HUMIDIFIER CONTROL, MODEL 700M:
Manual Control can be mounted in return duct or on wall in living space. Knob and cover must be removed to mount control. See wiring diagram for 24V control connections.
• For return duct mounting, position template in convenient location on duct.
Avoid injury from sharp edges when cutting opening. Make sure foam
gasket is in place and secure control to duct using 2 screws in holes provided.
• For wall-mount, select location that will not be affected by drafts or heat sources. Remove and discard foam gasket and secure control over wire access opening using screws & anchors provided.
DIGITAL HUMIDIFIER CONTROL, MODEL 700:
• Select location for control on return duct. Drill 3/4” hole for sensor. Knob and cover must be removed to mount control. Place control on duct with RH sensor extending into duct opening. Make sure gasket is in place around sensor cage. Secure control to duct using 2 screws in openings provided.
• See wiring diagrams on template and control instructions for 24 V control connections.
7. Humidifier will function with cold,
hot, softened or unsoftened water. Hot water (140°F max) is strongly recommended to provide maximum evaporative capacity. Saddle valve provided may be used to tap into water supply. See installation instructions on saddle valve package. Saddle valve is designed to be fully opened or closed. Do not use to regulate flow.
8. Run 1/4” copper tubing from saddle
valve to solenoid valve. DOUBLE-WRENCH TO PREVENT LEAKING. See Figure 4.
9. INSTALL DRAIN IN ACCORDANCE
WITH LOCAL CODES. Run 1/2” I.D. hose
from drain spud to floor drain. Make sure drain has constant downward slope and is not kinked. Do not over­tighten hose clamp onto drain spud. Do not use solvent adhesive on drain spud.
10. Check humidifier operation. Open
saddle valve and turn control to highest setting. Turn on furnace. Allow humidifier to run until water flows from drain. Make sure all electrical connections are secure and all plumbing connections are water-tight. Set control to proper setting.
NOTE: BEFORE LEAVING THE JOB SITE, MAKE SURE:
1. Saddle valve is fully open.
2. All plumbing connections are watertight.
3. Humidifier functions properly.
TEMPLATE MUST BE LEVEL
90-1244
and warranty information is given to owner in order to avoid unnecessary calls. Warrantyis void unless humidifier is installed by qualified heating and air conditioning contractor due to possible misapplication of product.
10008976 B2205118A 4.10
IMPORTANT! Be sure owner’s manual containing instructions for operation