Anthem ACR Operating Manual

ARC
Operating Guide
ANTHEM®ROOM CORRECTION
Assembly, Installation and Setup for the Anthem®Room Correction System
MUST
TM
The ARC
• Anthem
Kit includes:
®
Room Correction (ARCTM) software installation CD
• Microphone and microphone clip
• Telescoping stand and base
• USB microphone cable
®
The Anthem Anthem
Room Correction (ARCTM) kit is used in conjunction with
®
Statement processors to correct the effects of a room's reflective
surfaces on sound quality.
Before starting the procedure, note the following:
Steps to assemble:
1. Screw the telescoping stand into the base and tighten securely;
2. Screw the clip onto the stand and tighten securely;
3. Plug the USB microphone cable into the microphone;
4. Insert the microphone into the clip and point the microphone straight up.
• Your microphone will not work with any other unit, and your microphone calibration files will work only with your microphone. Use only the microphone and CD that were created for your processor.
• Your home theater system must be set up according to your Statement processor's Operating Manual.
• PC requirements are Windows XP, one serial port and one USB port two USB ports.
• If you are using a ‘USB to serial adapter’ to connect the PC to the processor:
1. Check the manufacturer’s website for the latest driver and make sure it is properly installed. If a Windows message pops up just before the driver is installed saying that the driver is not Windows­certified, DO NOT USE THE ADAPTER. Some "budget" adapters are known to load bad data into the processor, causing it to freeze.
2. The virtual port must be assigned to COM1-COM6 for installer to run. If installer cannot locate processor, go to Start Menu / Settings / Control Panel / System / Device Manager. Double-click
IMPORTANT! Your Statement processor must have v1.30 or later software installed. If you purchased your ARC
TM
kit separately from your processor,
then a software upgrade for your processor is required. This software
on Ports, then double-click on the adapter. In Port Settings, if it shows COM7 or higher, change to an available port between COM1 and COM6.
• If you are using a laptop, check your computer's power management settings to ensure that the measurement procedure is not interrupted.
If your Subwoofer also has Room Correction (‘EQ’) capabilities:
or
Since rooms and Room Correction systems vary, the definitive answer to which ‘EQ’ system to use will only come with trying Correction systems in
your
setup. Start with ARCTM. If the calculated line and target line closely resemble each other, then all should be well. However, if the calculated line is still quite wavy throughout, run the
TM
subwoofer’s Room Correction and then re-do ARC then allow ARC
TM
resources to focus strictly on the midrange.
. The sub's ‘EQ’ will
NOTE: If the subwoofer’s Room Correction is going to be used, it M be running when ARCTMstarts playing its sweep tones, otherwise ARC will not be measuring the subwoofers “real” performance.
®
upgrade is included on the Anthem
Room Correction (ARCTM) Software
Installation CD and also available at www.statement.anthemAV.com. Upgrade instructions are in your processor's Operating Manual.
both
Room
TM
Measurement procedure steps:
1. Insert the ARC
TM
software installation CD into your PC's CD or DVD drive. Software installation instructions will appear on your screen. If your computer does not allow a CD to auto-run, open the CD’s folder and double-click on setup.exe.
The installation process will install several files into an Anthem folder on your computer and create shortcuts on your Start Menu and Desktop. Included are two files beginning with your processor's serial number. (Examples: 123456_100002.cal. and 123456_100002Anthem.file).
NOTE: You can create a file in Standard mode and open it later in Advanced mode to view graphs of the results and make modifications.
2. Connect the microphone to the PC via USB and wait for the PC to complete the new hardware installation. Connect the PC to your
Statement processor's serial port via the PC's serial port or second USB. Run AnthemRoomCorrection.exe (select from the Start Menu or double-click the Desktop shortcut) and select either Standard or Advanced mode. If selecting Standard mode, the program will guide you through the steps.
IMPORTANT! Don't stand near the microphone or make extra noise when sweep tones are playing (it would be best to keep younger or talkative family members, and even pets, out of hearing range at this time). The program rejects continuous background noise (i.e. fans) but will give an error message requiring re-measurement if a sudden noise is made.
1
Measurement procedure steps:
(continued)
3. Position the microphone on or near the main seat (see diagram), at ear level when seated and pointing at the ceiling (remove cushions from seat if necessary to attain necessary height). To adjust the height of the telescoping stand, first loosen the large black clamp in the middle of the stand by rotating it counterclockwise.
POSITIONING TIP! The height at which the microphone sits is critical.
As mentioned, ideally the speakers’ high-frequency drivers should be at about the same height as the listener's ears. If the results with ARC sound too dull or too bright, adjust the microphone height slightly and repeat the procedure.
Five positions will be measured – the first must be the central seating position (see diagram ). The first position is also used to set the levels in the Statement processor’s Speaker Calibration Setup Menu. Center Channel EQ and Room Resonance Filter menu settings are disabled during this process and whenever ARC
TM
is in use. Set up the remaining positions symmetrically, at the four (or more) typical listening positions for your room. For information on the processor’s Setup Menu, refer to the processor's Operating Manual.
Even if your room has less than five seating positions, to ensure optimal sound measurements must be taken from five
different positions, at least
1ft. (30.5 cm) apart.
Steps 4 through 7 apply to Advanced User mode only. Standard Mode users go straight to Step 8:
4. Click on Measure – the Procedure will pop up.
5. When measurement procedure is done, save the file and click on Targets. The auto-detected settings are displayed but you can change them as
TM
you see fit. Once ARC
TM
on the ARC
TM
System Target menu, NOT on the Processor's crossover
is run, crossover settings must be changed only
menu. After each target change, follow steps 6 and 7, below. NOTE: The only advice that Technical Support can provide on setting targets is to use the auto-detected settings. Click OK.
6. When processing is done, click on Calculate.
7. When calculation is done, save the file and click on Upload.
8. You can now disconnect PC/microphone and turn ‘Room EQ’ on/off in the processor's Source Setup Menu according to each source. By default, it is turned on for all sources.
A Note to Custom Installers Using One Computer To Run ARC on Multiple Systems:
Once ARC from each ARC
TM
is installed on your PC, copy The TWO serialized files
TM
CD into the following default ARCTMdirectory:
C:\ProgramFiles\Anthem\AnthemStatement\AnthemRoomCorrection.
TM
www.anthemAV.com
ANTHEM®, ANTHEM®STATEMENT and SONIC FRONTIERS™are registered trademarks of Paradigm Electronics Inc. Copyright © Paradigm Electronics Inc. All rights reserved. The information contained herein may not be reproduced in whole or in part without our express written permission. We reserve the right to change specifications and/or features without notice as design improvements are incorporated.
®
can be reached Monday to Friday, 9:00 am – 5:30 pm (ET) at 905-362-0958
ANTHEM
E-mail: info@sonicfrontiers.com Technical Support: sfitech@sonicfrontiers.com
IN-610 030308
Loading...