RTD: 14 types, TC:13 types
Resistance: 0 to 4,000
5 to 4,000
mV: -10 to 75 mV
Ω (read)
Ω (source)
High level of protection
Fuse-less protection for internal circuitry
- a common cause of failure in other units
without this protection
CJC
Selectable feature - use with or without
cold junction compensation depending on
application
Setpoints
User-defined - make testing easier by
storing the necessary settings for repeated
test points and sequences
High accuracy
Accuracy up to ± 0.2°C / 0.36°F - including
programmed curves for easy use in most
any application
Easy connections
Jacks for 2, 3, or 4-wire RTDs and a
dedicated TC plug - allows for connection
of sensur-under-test
Complete marine program
Part of a complete program of marine
approved temperature, pressure and signal
calibrators; including temperature sensors
See more at www.jofra.com
PRODUCT DESCRIPTION
The JOFRA CSC200 handheld
calibrator offers you an easy-tooperate interface including a knob
for precise and rapid adjustment.
With features including a large
display and an auto stepping signal, the CSC200 makes troubleshooting and calibration of your
temperature sensors a snap.
Features
The CSC line of signal calibrators are dedicated units designed to make
your calibration and maintenance tasks easier to perform. The JOFRA
CSC200 is engineered for the calibration of temperature instruments
offering the ability to measure and simulate several different types of
RTDs and TCs. This instrument makes the job easy by ulitizing a thermocouple plug for easy connection and can work with 2, 3, or 4-wire RTDs.
The CSC200 also offers features such as user-defined setpoints with
a recall function, selectable cold junction compensation, and installed
curves for 14 RTD and 13 TC types. These handy time savers are combined in a package offering an easy-to-read, two line display and an
intuitive keypad with a knob for fine adjustments.
This calibrator is more than a simple tool but it is as straightforward as
any device that you have in your toolbox. The CSC200 signal calibrator
offers you the accuracy and features that you need in a convenient, compact, and easy-to-use package.
ISO 9001 Manufacturer
Specification Sheet
SS-CP-2332-US
Model CSC200
Compact Signal Calibrator
2 www.jofra.com
Clear dual line display
The CSC200 features a large two-line display. The upper
line shows the measured or sourced temperature, resistance, or mV value. The second line indicates the type of
sensor. The display also features several icons to allow for
quick recognition of the status of the unit.
Auto shutdown
The CSC200 offers an automatic
shutdown feature. This power saving
feature turns the calibrator off after it
has been idle for a specified period
of time. The time delay is factory set
to 30 minutes; but can be adjusted to
meet specific needs.
RTD modes
The CSC200 offers the ability to
source and read 14 types of RTDs.
The formulas (curves) for the different
types of RTDs are programmed into
the firmware of this unit. This makes
it possible to select the curve maching the sensor and perform the test
routine without the need for mathematical conversions. The CSC200
can be used with 2, 3, or 4-wire RTDs
making it flexible enough for virtually
all RTD calibrations.
TC modes
The CSC200 is also programmed with
the formulas for 13 TC types. Like the
RTD modes, the unit will source or
read TC sensors and provide a stable
and reliable reading. The unit has a
convenient TC plug for easy connection to the TCs and is also equipped
with CJC: the CJC may be turned off
it desired.
CSC200 as TC input with
an ITC
CSC200 as RTD input with
an ITC
Type
This is used to scroll through the
various types of sensors that are
installed in the CSC200 firmware.
Electrical connections
Inputs for 2, 3, and 4-wire RTD
probes, TC jack, and switch test
connections.
I/O
Selects whether the CSC200 is
reading or sourcing values.
Set and Recall operation
The CSC200 offers you a timesaving
feature that is not offered amongst
lesser calibrators. You can store up to
3 test points for each of the TC and
RTD functions. This means that there
is no need to repeatedly set each
value for your test needs; just store
the setpoints for your test and call
them up for each sensor. The Recall
button is your “hot key” to retrieve
the stored values in sequential order.
If you have several types of sensors
in your process, the CSC200 makes
it easy because you can store set values for each type.
Left / Right arrows
Move the cursor left or right to allow
for adjustment of the desired decade.
Adjustment Knob
Allows for easy adjustment of values.
Combined with the Arrow Keys,
reaching the desired value is easy.
FUNCTIONAL SPECIFICATIONS
Display
LCD .......................................................Dual line plus icons
Connection ..................................................2, 3, and 4-wire
OhmRangeAccuracy±
minmax12 months
Ohm read (low)
Ohm read (high)
Ohm source (low)
0.1 to 0.5 mA
0.5 to 3 mA
Ohm source (high)
0.05 to 0.8 mA
0.05 to 0.4 mA
Unit is compatible with pulsed transmitters - Frequency response is ≤ 5 m
Sec.
0.0 Ω
400.1 Ω4000.0 Ω0.025% rdg. ±0.5 Ω
5.0 Ω
5.0 Ω
400.0 Ω
1500.0 Ω
RTD TypeTemperature range
°C°F°C°F
From ToFrom To
-200.0100.0-328.0 212.01.402.52
Pt10
Alpha 385
Pt50
Alpha 385
Pt100
Alpha 385
Pt100
Alpha 3926
Pt100
Alpha 3916
Pt200
Alpha 385
Pt500
Alpha 385
Pt1000
Alpha 385
Cu10
Cu50
Cu100
YSI400
100.0300.0 212.0 572.01.602.88
300.0600.0 572.0 1112.01.803.24
600.0800.01112.0 1472.02.003.60
-200.0100.0-328.0 212.00.400.72
100.0300.0 212.0 572.00.500.90
300.0600.0 572.0 1112.00.601.08
600.0800.01112.0 1472.00.701.26
-200.0100,0-328.0 212.00.200.36
100.0300.0 212.0 572.00.300.54
300.0600.0 572.0 1112.00.400.72
600.0800.01112.0 1472.00.500.90
-200.0100.0-328.0 212.00.200.36
100.0300.0 212.0 572.00.300.54
300.0630.0 572.0 1166.00.400.72
-200.0100.0-328.0 212.00.200.36
100.0300.0 212.0 572.00.300.54
300.0630.0 572.0 1166.00.400.72
-200.0100.0-328.0 212.00.801.44
100.0300.0 212.0 572.00.901.62
300.0630.0 572.0 1166.01.001.80
-200.0100.0-328.0 212.00.400.72
100.0300.0 212.0 572.00.500.90
300.0630.0 572.0 1166.00.601.08
-200.0100.0-328.0 212.00.200.36
100.0300.0 212.0 572.00.300.54
300.0630.0 572.0 1166.00.400.72
-100.0260.0-148.0500.01.402.52
-180.0200.0-292.0392.00.400.72
-180.0200.0-292.0392.00.300.54
15.0 50.059.0122.00.100.18
400.0 Ω 0.025% rdg. ±0.05 Ω
400.0 Ω
400.0 Ω
1500.0 Ω
4000.0 Ω
0.025% rdg. ±0.02/Iexc
0.025% rdg. ±0.05 Ω
0.025% rdg. ±0.05 Ω
0.025% rdg. ±0.05 Ω
12 month
accuracy
Temperature coefficient
Stability: ..... ± 0.005% of reading /°C outside of 23°C ±5°C
..................± 0.003% of reading /°F outside of 73.4°F ±9°F
Read accuracy is based on a 4-wire input, for a 3-wire input add
0.005 Ω assuming all leads are matched.
Accuracies are stated for operation at 23°C add ± 5°C / 73.4°F.
For operation < 18°C or > 28°C add ± 0.005% of reading /°C / <
64.4°F or > 68.8°F add ±0.003% of reading / °F.
www.jofra.com 3
ORDERING INFORMATION
Order no. Description
Base model
CSC200 Handheld Temperature Signal Calibrator
Certification
G NIST traceable temperature certificate (standard)
H Accredited calibration certificate
CSC200G Sample order number
CSC200 calibrator with standard NIST traceable temperature certificate
STANDARD DELIVERY
JOFRA CSC200 loop calibrator
•
Traceable calibration certificate
•
Reference manual
•
Test leads
•
Soft carrying case
•
Shoulder strap
•
ACCESSORIES
120519 Thermocouple Male Plug - Type Cu-Cu - White
120518 Thermocouple Male Plug - Type R / S - Green
120517 Thermocouple Male Plug - Type K - Yellow
120516 Thermocouple Male Plug - Type J - Black
120515 Thermocouple Male Plug - Type T - Blue
120514 Thermocouple Male Plug - Type N - Orange
121983 Extension Cable for Type K - 5 m
122523 Extension Cable for Type N - 5 m
2206011 Thermocouple plug + K wire + alligator
2206012 Thermocouple plug + T wire + alligator
65-PT100-LB-CABLE Cable 2 m (6.6 ft.) with LEMO / Banana connectors
124717 1x 9 Volt rechargeable battery
124718 Charger for rechargeable batteries - 115/230 VAC
CSC200 in soft case
All JOFRA handheld calibrators are supplied
in a handy soft case that allows for operation while in the case. The convenient internal
storage pocket offers the space for test leads
and accessories.
is one of the world’s leading manufacturers and
AMETEK Calibration Instruments
developers of calibration instruments for
temperature, pressure and process signals
as well as for temperature sensors both from
a commercial and a technological point of view.
JOFRA Temperature Instruments
Portable precision thermometers. Dry-block and
liquid bath calibrators : 4 series, with more than
25 models and temperature ranges from
-90° to 1205°C / -130° to 2200°F. All featuring speed,
portabilit y, accuracy and advanced documenting
functions with JOFRACAL calibration software.
JOFRA Pressure Instruments
Convenient electronic systems ranging from
-1 to 1000 bar (25 inHg to 14,500 psi) -
multiple choices of pressure ranges, pumps and
accuracies, fully temperature- compensated
for problem-free and accurate field use.
JOFRA Signal Instruments
Process signal measurement and simulation for
easy control loop calibration and measurement
tasks - from handheld field instruments to
laboratory reference level bench top instruments.
JOFRA / JF Marine Instruments
A complete range of calibration equipment
for temperature, pressure and signal,
approved for marine use.
FP Temperature Sensors
A complete range of temperature sensors
for industrial and marine use.
M&G Pressure Testers
Pneumatic floating-ball or hydraulic piston dead
weight testers with accuracies to 0.015% of reading.
M&G Pumps
Pressure generators from small pneumatic
“bicycle” style pumps to hydraulic pumps
generating up to 1,000 bar (15,000 psi).
.. .beca use calib ratio n is
a ma tter of c onfid ence