American Standard R540 User Manual

Installation
Instructions
R540
CENTRAL THERMOSTAT with VOLUME CONTROL
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS VERTICAL HORIZONTAL
1-3/4"
to 2-1/2"
13/16"
FINISHED
WALL
hot in
cold in
mixed
out
mixed
out
6-1/2"
2-3/16"
2"
3-1/8"
cold in
hot in
3-1/8"
Certified to comply with ANSI A112.18.1M ASSE 1016
mixed
out
mixed
out
13/16"
MAX
M968257
1-3/4"
to 2-1/2"
FINISHED
WALL
2-13/16"
NOTE: ALL PORTS ARE 3/4 NPT FEMALE. FITTING MUST BE INSTALLED WITH VOLUME CONTROL ON TOP.
THERMOSTATIC BATH/ SHOWER INSTALLATION USING A TWIN ELL, DIVERTER SPOUT AND FIXED SHOWER
C/L
80"-86"
SHOWER PORT
18"
TWIN
ELL
TOP OF TUB RIM
BOTTOM OF TUB
THERMOSTATIC VALVE INSTALLED
IN THE VERTICAL POSITION
IMPORTANT:
DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED.
WHEN NOT USING A
MUST BE PLUGGED
4"
THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD AND ADJUSTABLE HAND HELD SHOWER
DIVERTER
VALVE
HOT COLD
3/4"3/4"
TUB PORT MUST BE PLUGGED
THERMOSTATIC VALVE INSTALLED
IN THE HORIZONTAL POSITION
THERMOSTATIC SHOWER INSTALLATION USING A DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE HAND HELD SHOWER, ON/OFF VALVE AND THREE BODY SPRAYS
DIVERTER
VALVE
ON/OFF
VALVE
HOT COLD
3/4"3/4"
TUB PORT MUST BE PLUGGED
THERMOSTATIC VALVE INSTALLED
IN THE HORIZONTAL POSITION
ROUGHING-IN THE VALVE
1
Decide on desired configuration. Prepare water supplies per ROUGHING-IN DIMENSIONS. Install VALVE at indicated height and depth.
Connect HOT water supply to inlet marked with the RED DOT and COLD water supply to inlet market with the BLUE DOT.
Assemble the CONNECTING PIPE to one of the MIXED OUTLETS of the VALVE.
Note
: The tub port is fitted with a plug at the factory.
Important! Install any required shut off or diverter valves into the piping system.
CAUTION
Turn off hot and cold water supplies before beginning.
HOT
INLET
COLD
INLET
MAX
CROSS BRACE
VALVE
BODY
WARNING
Secure VALVE body to cross brace of wall structure.
FLUSHING THE VALVE
2
Water should be flushed through the piping to prevent clogging of the
Remove PLASTER GUARD (1).
Turn ADAPTER (2) on volume control clockwise until it reaches the stop.
Pull off ADAPTER (2).
Remove CLUTCH COVER SCREWS (3) and CLUTCH COVER (4).
Pull out CLUTCH DRIVE SHAFT (5).
Loosen the SCREWS (6) in the center of the GEARS (7). Remove the GEARS (7) and BACK PLATE (8).
Remove the COLD CARTRIDGE (9) using a 22mm socket wrench.
Turn on MAIN COLD WATER SUPPLY to flush line.
Reassemble COLD CARTRIDGE (9) and repeat flushing steps for HOT side (9a).
Replace BACK PLATE (8). Assemble both GEARS (7) with the flat side facing BACK PLATE (8) and tighten SCREWS (6).
IMPORTANT:
DO NOT SOLDER DIRECTLY TO THE VALVE BODY; THIS WILL DAMAGE THE TEMPERATURE CONTROL ELEMENT.
CAUTION
Turn off hot and cold water supplies before beginning.
Thermal Element.
Close both CARTRIDGES (9, 9a) by rotating GEARS (7) counterclockwise.
Replace CLUTCH DRIVE SHAFT (5) and CLUTCH COVER (4) with SCREWS (3).
Turn VOLUME CONTROL HANDLE 180 to synchronize the HOT and COLD CARTRIDGES.
Turn on water supply and check for leaks.
PLASTER
SCREWS
8
GUARD
9a
9
7a
7
PLASTER
GUARD
1
6a
6
MIXED
OUTLET
MAX
5
PLASTER
4
GUARD
SCREWS
3
2
TEMPERATURE CALIBRATION
3
Check that arrow marking B points vertically upwards. If not, push the BLACK CLAMP (1) on the SECURING RING (2) to the right, pull off KNOB MOUNT (3) and reinstall KNOB MOUNT (3) with arrow "B" pointing vertically upwards.
SET HOT LIMIT STOP
The maximum mixed water temperature is set at 109 F at the factory. This setting can be changed if desired.
Remove the TEMPERATURE LIMIT STOP (4) (H shaped Black Plastic part). Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F.
For 100 F adjustment, turn the water supply on. Turn KNOB MOUNT (3) until the spout temperature is 100 F. Check that arrow marking A on the KNOB MOUNT (3) still points upward after adjusting the thermostat to 100 F. If not, pull out the RED LOCKING DEVICE (5). Remove KNOB MOUNT (3) without turning by sliding out as indicated by the arrow.
Reinstall the KNOB MOUNT (3) so that the arrow marking A points upwards. Reinstall RED LOCKING DEVICE (5).
ARROW
"B"
4
104
109
112
2
5
1
ARROW
"A"
3
M968257