Pedestal Lavatory
Observe Local Plumbing
and Building Codes
AMERICAN STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American Standard plumbing product, within one year
after its initial installation, confirms that it is defective in materials or workmanship,
American Standard will repair or, at its option, exchange the product for a similar
model.
This limited warranty does not apply to local building code compliance;
since local building codes vary considerably, the purchaser of this product should
check with a local building or plumbing contractor to insure local code compliance
before installation.
This warranty shall be void if the product has been moved from its initial
place of installation; if it has been subjected to faulty maintenance, abuse, misuse,
accident or other damage; if it was not installed in accordance with American
Standard's instructions; or if it has been modified in a manner inconsistent with the
product as shipped by American Standard.
American Standard's option to repair or exchange the product under this
warranty does not cover any labor or other costs of removal or installation, nor
shall American Standard be responsible for any other incidental or
consequential damages attributable to a product defect or to the repair or
exchange of a defective product, all of which are expressly excluded from
this warranty. (Some states or provinces do not allow the exclusion or limitation
of implied warranties, so this exclusion may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory
rights that vary from state to state or from province to province, in which case this
warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through
the contractor or dealer from or through whom the product was purchased, or that
a service request (including a description of the product model and of the defect)
be sent to the following address:
In the United States:
AMERICAN STANDARD, INC.
P.O. Box 6820
Piscataway, New Jersey 08855
Attn: Director of Consumer Affairs
For residents of the United States, warranty information may also be
obtained by calling the following toll free number: (800) 223-0068
In Canada:
AMERICAN STANDARD, INC.
2480 Stanfield Road
Mississauga, Ontario Canada L4Y 1S2
Toll Free: (800) 387-0369 Toronto Area: (905) 276-6022
In Mexico:
IDEAL STANDARD, S.A. de C.V
Customer Service Manager
Planta Santa Clara,Via Morelos #330
Santa Clara Coatitla
Ecatepec de Morelos 55540,
Estado de Mexico, Mexico
Installation Instructions
Introduction: Thank you for selecting our products...products which
have been the benchmarks of fine quality for years. To help insure that
the installation process will proceed smoothly, please read these instructions carefully before you begin. Also, review the recommended tools
and materials list; carefully unpack and examine your new plumbing
fixture.
Recommended Tools & Materials
Adjustable Wrench
Drill
Basin Wrench
Saber Saw
C/L of 2X6
Support
Plumbers' Putty or
Caulking
*
Finished
Floor
Pedestal Location
Tubing Cutter
Tape
Measure
Hacksaw
Anchor Screw
or Lag Bolt
Location
10'
Pipe Wrench
Channel Locks
Phillips Screwdriver
Regular Screwdriver
1
Putty Kinfe
Level
Provide suitable reinforcement behind finished
wall for lavatory anchor
screws. *Determine horizontal
center line location of support
from fixture.
NOTE:
If replacing an existing lavatory
be certain to shut off water
supply before removing old
lavatory.
730235-100 Rev. F
Saniwares
© American Standard Inc. 2000
2
3
4
5
730235-100 Rev. F
Place lavatory and pedestal
into installed position. Level
and square the lavatory and
pedestal assembly. Use one
or more bumper cushions
(supplied) to level and
cushion lavatory slab to
pedestal.
Mark lavatory and pedestal screw locations through the
mounting holes. If a steel hanger is supplied mark the location
of its screws when positioned as shown in step 5a.
Remove lavatory and pedestal from
installed position. Drill pilot holes
for lavatory and pedestal anchor
screws or lag bolts. Note: Some
models are supplied with lag bolts,
anchor screws, or steel hangers
for lavatory installations only. Other
models and all pedestals are not
provided with mounting hardware.
Various pedestal screw sizes and
types are available to the installer
at local hardware outlets.
ANCHOR SCREW
INSTALLATION
Install lavatory anchor
screws leaving 1-7/8"
threaded end exposed
as illustrated.
1-7/8"
Lavatory
Anchor
Screw
Nut
Washer
IMPORTANT: Final assembly of nut and washer or lag bolt method
shown for reference only. (See steps 8 and 9).
Top of Pedestal
Approx. Bumper
locations to raise
the lavatory slab
left side.
For example only
5a
Lavatory
LAG BOLT
INSTALLATION
Use lag bolts to secure
lavatory as illustrated.
Steel
Hanger
Lag
Bolt
Washer
Lavatory
6
7
8
9
Following manufacturer's
instructions, install faucet
and drain assembly (not
included). Be certain to
apply a bead of sealing putty
on the underside of the drain
(area "A") in order to ensure
a watertight seal between the
lavatory and drain. Remove
excess putty after installing
drain on lavatory.
Return the fitted lavatory and pedestal to the
installed position. Connect trap to drain assembly hand tight to check
alignment. It may be necessary to cut off part
of the tailpiece (area "B")
and/or part of the drain
elbow of the trap (area "C").
Secure lavatory to wall as
shown in 5 or 5a. Install
washers and hand tighten
nuts or lag bolts.
Level and square the unit.
Connect hot and cold supply
lines to the shut-off valves.
Tighten trap joints for watertight assembly.
Install pedestal screws.
Securely tighten lavatory
anchor nuts or lag bolts.
Note: Space constraints may
dictate method of fastening
pedestal to floor.
A
C
B
Shut-Off
Valves
Rear
View
Pedestal
Screws