UNPACKING
Remove the Flush Valve items from the carton. The illustration below shows all items
after they have been removed from the carton. Some items may be packaged partially
assembled to other items.
1. Flush Valve Assembly
2. Vacuum Breaker Assembly for Toilet
2a. Vacuum Breaker Assembly for Urinal
3. Spud Coupling Nut and Washers for Toilet
3a. Spud Coupling Nut and Washers for Urinal
4. Spud Flange for Toilet
4a. Spud Flange for Urinal
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
8. Supply Stop
9. Side-Mount Operator
10. Wrench Kit
CARE INSTRUCTIONS:
DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
6
7
9
1
5
8
10
2
2a
3
3a
4
2
4a
M965890 Rev. 1.1 (1/19)
Roughing-in Dimensions
Fig.1
147 mm
(5-13/16")
108 mm-133 mm
(4-1/4" to 5-1/4")
SUPPLY
DN 19 mm
(1" I.P.S.
For 1"
Top Spud)
FINISHED WALL
38 mm-127 mm
(1-1/2-5")
Roughing-in Dimensions
Fig.2
147 mm
(5-13/16")
108 mm-133 mm
(4-1/4" to 5-1/4")
SUPPLY
DN 19 mm
(3/4" I.P.S.
For 3/4"
Top Spud)
FINISHED WALL
38 mm-127 mm
(1-1/2-5")
*CRITICAL
253 mm
(9-15/16")
6047.1x1
ROUGH-IN
DIMENSION
-C-L-
LEVEL
152 mm
(6")
(Min.)
FOR 1-1/2" TOP
SPUD FIXTURES
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
Consult Codes for details.
" (152mm) minimum above fixture.
292 mm
(11-1/2")
DIMENSION
6047.1x2
ROUGH-IN
DIMENSION
686 mm
(27")
6047.117
ROUGH-IN
610 mm
(24")
Right or Left Hand Installation
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
FINISHED WALL
57 mm Min.
(2-1/4")
SUPPLY
DN 25 mm
(1" I.P.S.)
6047.1x1
371 mm
-C-L-
(14-5/8")
6047.117
689 mm
(27-1/8")
6047.1x2
765 mm
(30-1/8")
253 mm
(9-15/16")
*CRITICAL
LEVEL
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6
Consult Codes for details.
1. Measure the distance (A) from the nished wall to the
center of the inlet spud on the xture.
2. Cut the supply pipe 1-1/4" (A-B=C) shorter than the
measurement taken in Step 1. File any rough edges
off the end of the supply pipe.
3. Clean the end of the supply pipe. Push the threaded
Adapter until it is seated against the internal stop.
Sweat the Adapter to the pipe.
INSTALL COVER TUBE, WALL
2
ESCUTCHEON and STOP VALVE; Fig. 4
1. Measure from nished wall to rst thread of Adapter or
threaded supply pipe (dimension “X”). Cut COVER TUBE
(1) to length (X). Apply Teon Tape to the threaded end of
the Adapter or supply pipe.
2. Push WALL ESCUTCHEON (2) onto the COVER TUBE (1).
Slide both onto the SUPPLY PIPE (3).
3. Push the COVER TUBE (1) in to expose the threads of
the supply pipe. With a wrench thread the STOP VALVE
(4) onto the SUPPLY PIPE (3). Align and tighten.
4. Pull COVER TUBE (1) against STOP VALVE (4) and push WALL ESCUTCHEON (2) against nished wall.
Turn water supplies off before
beginning
Fig. 3
Fig. 4
Fig. 4a
Fig. 4b
Fig. 4c
FINISHED WALL
A
(A-B)=
C
FILE EDGES
CLEAN
ADAPTER
SOLDER
ADAPTER
3
B
FINISHED WALL
X
2
CENTER LINE OF
FIXTURE SPUD
32mm
(1-1/4")
TEFLON TAPE
2
X
4
1
INSTALL VACUUM BREAKER TUBE; Fig. 5
3
1. Place the SPUD FLANGE (1) over the spud on
the Fixture.
2. Place FRICTION WASHER (3) and SEAL WASHER
(4) inside SPUD COUPLING NUT (2) and thread
onto Spud. Do not tighten fully.
3. Insert the VACUUM BREAKER TUBE (5) or (5a) into the
SPUD COUPLING NUT (2) and push it down.
Note: If cutting VACUUM BREAKER TUBE (5) to size, note
that Critical Line (C/L) on Vacuum Breaker must typically
be 6” (152mm) above xture. Consult Code for details.
4
Fig. 5
5a
5a
2
1
1
3
4
M965890 Rev. 1.1 (1/19)
INSTALL FLUSH VALVE; Fig. 6a & 6b
4
1. As shown in Fig. 6a, insert the side INLET FLANGE (1)
on the FLUSH VALVE (2) into the SUPPLY STOP (3).
Lubricate the INLET FLANGE O-RING (4) with water if
necessary. Lightly tighten COUPLING NUT (5). Fig. 6a.
Important: Do not use lubricants (other than water) or
any type of thread sealing paste or tape.
2. Align the FLUSH VALVE (2) (Fig. 6b) directly above
the VERTICAL TUBE (7) and VACUUM BREAKER
COUPLING NUT (6).
Note: There is a ±13mm, (±1/2) tolerance for the 121mm
(4-3/4) dimension. Fig. 6b.
3. Pull the VACUUM BREAKER COUPLING NUT (6) up
to meet the threaded FLUSH VALVE CONNECTION (8)
and hand tighten. Align all components of the ush valve
assembly. Fig. 6b.
4. Lightly tighten the COUPLING NUT (5) connection rst,
then the VACUUM BREAKER COUPLING NUT (6) and
nally the SPUD COUPLING NUT (9). Once alligned
correctly, use a wrench to tighten couplings to make water
tight connections. Fig. 6b.
5. After installing FLAT SEAL (10) into FLUSHING UNIT (11),
install FLUSHING UNIT (11). Fig. 6b.
Fig. 6a
Fig. 6b
11
10
3
1
5
4
2
+
121mm, 13mm
–
+
(4-3/4")( 1/2")
–
5
2
8
FLUSH OUT SUPPLY LINES; Fig. 7
5
1. Make sure supply stop is closed. Remove COVER (1)
from SUPPLY STOP (2). With a at blade screwdriver
close CONTROL STOP (2).
2. Remove FLUSH VALVE CAP (3 & 4). Pull out
DIAPHRAGM ASSEMBLY (5). Replace FLUSH VALVE
CAP (3 & 4) and tighten.
3. With a at blade screwdriver open SUPPLY STOP (2).
to ush line of any debris or sediment.
4. Close SUPPLY STOP (2). Remove FLUSH VALVE
CAP (3 & 4). Replace DIAPHRAGM ASSEMBLY (5).
Replace FLUSH VALVE CAP (3 & 4) and tighten.
Fig. 7
3
4
5
REMOVE COVER
6
7
9
2
COUNTER-CLOCKWISE
OPENS CONTROL STOP
CLOCKWISE
CLOSES CONTROL STOP
1
5
M965890 Rev. 1.1 (1/19)
ACTIVATION; Fig. 8
6
Note: Four (4) “C” Cell batteries are not factory installed
inside the Flush unit.
1. Remove BATTERY TRAY (1) by loosening SCREW (3).
3. Install battery tray into SIDE MOUNT OPERATOR (2) and
tighten SCREW (3) using WRENCH (4) provided.
(Note: last three turns of the wrench will activate the
automatic ushing unit)
ADJUSTING SENSOR DISTANCE; Fig. 8 & 9
7
1. Remove BATTERY TRAY (1) by loosening SCREW (3).
Fig. 9
2. Remove FRONT COVER (2) and remove SENSOR
ADJUSTMENT TOOL (4). Fig. 9
3. Install BATTERY TRAY (1) and SCREW (3) back into the
unit. Fig. 9
4. Press RANGE RESET BUTTON (5) (When object in view,
it will ash green light for 7 minute rest period). Fig. 9
5. Stand at a desired distance and use the SENSOR
ADJUSTMENT TOOL (4) to turn SENSOR ADJUSTMENT
SCREW (6) all the way counter clockwise and then turn
clockwise until green L.E.D begins to Flash. Fig. 9
Fig. 8
3
4
Fig. 9
3
Fig. 10
5
--
++
1
+
-
2
5
6
OPERATION
RANGE
FEATURES
RESET
BUTTON
+
-
1
2
4
LOCATED INSIDE FRONT COVER
ADJUSTING MODES OF OPERATION;
8
Fig. 9 &10
The FLUSH unit includes different modes of operation.
Remove FRONT COVER (2) by loosening up SCREW (3) by
using a wrench and removing BATTERY TRAY (1). Refer to
the “Mode Adjustment Guide” for switch settings. The “Mode
Adjustment Guide” can also be found on the inside of side
cover for your convenience.
24 Hour
Flush On
Allows the ush valve to automatically
ush after 24 hour period of non-use to
maintain the trap seal.
It beeps when the battery is running low. If
Alarm Tone
you don’t want it to beep, you can turn off
this feature, with the toggle switches.
BATTERY REPLACEMENT; Fig. 8
9
1. Remove BATTERY TRAY (1) by loosening SCREW (3).
2. Replace 4 “C” Alkaline BATTERIES (2). (Note: Replace all
4 batteries at the same time for proper function)
VISUAL INDICATOR GUIDE; Fig. 12
10
User – In View L.E.D (1) – 5 second after a user is in view a
green light ashes 3 times.( during a startup sequence the green
light ashes constantly for 7 minutes when a user is in view)
Battery L.E.D (2) – Yellow light ashes which indicates that the
batteries all 4 “C” Alkaline batteries will need to be replaced.
Object Lock Sensor (3) – Detects user or object.
Mechanical Push Button – Allows manual activation of ush
when needed and when batteries are drained.
Sensor Range
Adjustment
1ON2
Urinal Model Only
Fig. 12
Object Lock Sensor
Battery L.E.D
Mechanical Push Button
Use Sensor
Screw
Operation
Features
User – In View L.E.D
Adjustment
Tool
1ON2
Switch 1
24 Hours Flush On
Switch 2
Alarm Tone Off
Near
-
Urinal Model Only
+
1ON2
Switch 1
24 Hours Flush Off
Switch 2
Alarm Tone On
Far
6
M965890 Rev. 1.1 (1/19)
ADJUST SUPPLY STOP; Fig. 13
OPENS CONTROL STOP
11
IMPORTANT: To avoid overowing, the SUPPLY STOP (3)
must never be opened to the point where the ow from
the valve exceeds the ow capacity of the xture.
Valve is designed to provide stated ush volume with a
25 gpm ow rate for toilet and 10 gpm ow rate for urinal.
1. Remove COVER (2) from SUPPLY STOP (3).Turn on
water supply 1/4 turn to 1/2 turn(CCW) and test for leaks.
Note: Unit may ush for approximately 5 to 10 sec. when
water is rst turned on.
2. Push down on HANDLE (4) to initiate ush.
3. Adjust SUPPLY STOP (3) after each ush until the
stated ush volume is achieved, no splashing occurs
and the xture is properly cleansed.
4. When adjustment is complete, reinstall COVER (2)
and tighten to ensure vandal-resistance.
HOW TO RETROFIT OUR VALVE; Fig. 14
12
(Replaces Industry Standard Manual and Electronic
Valves)
Note: In most Retrots the wall escutcheon, supply
stop, cover tube and vacuum breaker do not have to
be replaced. If these items do need replacement they
must be purchased separately or order the complete
ush valve assembly from American Standard.
Fig. 13
REMOVE COVER
3
COUNTER-CLOCKWISE
CLOCKWISE CLOSES
CONTROL STOP
Fig. 14Fig. 14aFig. 14b
5
2
1
CLEAN
CONNECTIONS
3
4
2
1. Remove COVER (1) from SUPPLY STOP (2) if installed.
M962836-0020A (8-1/4" to 9-1/4" Rough-in)
M962835-0020A (7-1/4" to 8-1/4" Rough-in)
M962834-0020A (6-1/4" to 7-1/4" Rough-in)
M962833-0020A (5-1/4" to 6-1/4" Rough-in)
M964402-0070A
HIGH BP VACUUM
BREAKER REPAIR KIT
MODEL NUMBERS
6145SM
A912809-0070A
TAILPIECE O-RING
M964075-0070A
3/4" SWEAT ADAPTER
M964412-0020A
3/4" VACUUM
BREAKER ASSEMBLY
FOR 11-1/2" (220 mm)
ROUGH-IN
M952262-0020A
ESCUTCHEON KIT
M952261-0020A
3/4" INLET PIPE
ASSEMBLY
8
M955058-0020A
3/4" STOP VALVE
STOP VALVE REPAIR KIT
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@lixilamericas.com
M970355-0020A
M924347-0020A
STOP VALVE CAP
For toll-free information and answers to your questions, call:
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
M962836-0020A (8-1/4" to 9-1/4" Rough-in)
M962835-0020A (7-1/4" to 8-1/4" Rough-in)
M962834-0020A (6-1/4" to 7-1/4" Rough-in)
M962833-0020A (5-1/4" to 6-1/4" Rough-in)
M964402-0070A
HIGH BP VACUUM BREAKER
REPAIR KIT
MODEL NUMBERS
6147SM
M962926-0070A
1" SWEAT ADAPTER
A955056-0020A
1" STOP VALVE
M964413-0020A
VACUUM BREAKER
ASSEMBLY 27"
(686 mm) ROUGH-IN
M952269-0020A
ESCUTCHEON KIT
A955057-0020A
9
1" INLET PIPE
ASSEMBLY
STOP VALVE REPAIR KIT
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@lixilamericas.com
M970355-0020A
M924347-0020A
STOP VALVE CAP
For toll-free information and answers to your questions, call:
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST