NOTE TO INSTALLER: Please give this manual to the customer after installation.
To l ea r n m or e ab ou t A me r ic an S ta nd ar d Fa uc e ts vi si t ou r w e bs it e at : www.americanstandard.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call
1-800-442-1902 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
In s ta ll a ti on In s tr u ct io n s
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
1. Remove the Flush Valve items from the carton. The illustration below shows all items after
they have been removed from the carton. Some items may be packaged partially assembled to
other items.
1. Flush Valve Assembly
2. Down Tube and Vacuum Breaker
3. Spud Coupling Nut and Washers
4. Spud Flange
5. Sweat Solder Adapter
6. Cover Tube
7. Wall Escutcheon
8. Supply Stop
9. Installation Instructions
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR
EYE UNTIL INSTALLATION IS COMPLETE.
6
5
7
8
1
2
3
9
SELECTRONIC™
PROXIMITY TOILET FLUSH VALVE
1.1 1.28 & 1.6 GPF
MODEL NUMBERS
6065.161
6065.111
6065.525
6065.121
6065.565
7095.121
Exposed Flushometer
for 1-1/2" Top Spud Bowls
CLOG RESISTANT
CLOG RESISTANT
• Self-cleaning piston valve prevents clogging and reduces maintenance.
• Self-cleaning piston valve prevents clogging and reduces maintenance.
ONE SENSOR FITS ALL
ONE SENSOR FITS ALL
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves.
• Range can be adjusted manually or with optional remote control.
• Range can be adjusted manually or with optional remote control.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To le a r n m o re ab o u t Am e r ic a n S t an d a rd Fa uc e t s v i si t o u r w e bs i te a t: www.americanstandard.com
or U.S. customer's e-mail us at: faucetsupport@americanstandard.com
For Parts, Service, Warranty or other Assistance,
1-800-442-1902 (In Canada: 1-800-387-0369)
please call
(In Toronto Area only: 1-905-3061093)
(In Toronto Area only: 1-905-3061093)
4
1
M968699 Rev. 1.15
Fig. 1
Roughing-in Dimensions
72mm
(2-7/8")
116 mm
(4-5/8")
MANUAL
OVER RI DE
11- 1/ 2"
(293mm)
BUTTON
*CRITICAL
LEVEL
*-C-L-
6"
(152mm)
-C-L-
115 mm -1 34 mm
(4- 1/ 2" TO 5 -1 /4" )
FOR 1-1/2" TOP
SPUD FIXTURES
SUPPLY
DN 25mm
(1" I.P.S.)
16-1/8"
(409mm)
DETECTION ZONE
400mm-800mm
(15- 3/ 4" TO 3 1-1/2")
FINISHED WALL
57mm
(2-1/4" MIN.)
GENERAL DESCRIPTION:
SELECTRONIC™
PROXIMITY TOILET
FLUSH VALVE
Exposed Flushometer
for 1-1/2" Top Spud Fixtures
Exclusive, self cleaning piston-type flush
15˚
valve with proximity operation and
manual override. Operates on DC
(ba tt er y ) pow e r. Re c o m me n d e d
operating pressure 35 to 80 psi. Can
install left or right-handed. Detection
Zone can also be adjusted manually, or
with optional remote control.
Right or Left Hand Installation
See
(Section 5) for converting Flush
Valve to Left Ha nd I nsta lla tion .
*Note: The Crit ical Line (- C-L-) on Vacuum
Breaker must typically be 6
fixture. Consult Codes for details.
" (152mm) above
RECOMMENDED TOOLS; Fig. 2
1.
Teflon Tape
2.
Flat Blade Screwdriver
3.
Adjustable Wrench
4.
Tape Measure
5.
Hacksaw
6.
Tubing Cutter
7.
File
8.
For Sweat Connection; Solder and Torch
9.
2.5mm Hex Wrench
10.
1.5mm Hex Wrench
PRIOR TO INSTALLATION
Note: Prior to installing the Selectronic™Flush Valve
the following items must be installed.
1. Water Closet
2. Drain line
Fig. 2
1
2
4
10'
3
6
5
8
7910
• Flush all water lines prior to operation (See Step 4). Dirt
and debris can cause flush valve to run continuously.
• With the exception of Supply Stop Inlet, DO NOT use
pipe sealant or plumbing grease on any valve component
or coupling!
3. Water supply line
IMPORTANT:
• All plumbing must be installed in accordance with
applicable codes and regulations.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
• Protect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
1. Measure the distance (A) from the finished wall to the
center of the inlet spud on the fixture.
2. Cut the supply pipe 1-1/4" (A-B=C) shorter then the
measurement taken in Step 1. File any rough edges off
the end of the supply pipe.
3. Clean the end of the supply pipe. Push the threaded
Adapter on until it is seated against the internal stop.
Sweat the Adapter to the pipe.
INSTALL COVER TUBE, WALL
2
ESCUTCHEON and SUPPLY STOP;
Fig. 4
1. Measure from finished wall to first thread of Adapter
or threaded supply pipe (dimension “X”). Cut COVER
TUBE (1) to length (X). Apply Teflon Tape to the
threaded end of the Adapter or supply pipe. Fig. 4a.
2. Push the COVER TUBE (1) into the WALL
ESCUTCHEON (2). Slide both onto the SUPPLY PIPE
(3). Fig. 4b.
3. Push the COVER TUBE (1) in to expose the threads
of the supply pipe. Fig. 4c. With a wrench thread the
SUPPLY STOP (4) onto the SUPPLY PIPE (3). Align
and tighten. Fig. 4c.
4. Pull COVER TUBE (1) against SUPPLY STOP (4)
and push WALL ESCUTCHEON (2) against finished
wall.
Fig. 4
Fig. 5
Fig. 4a
Fig. 4b
Fig. 4c
(A-B)=
C
FILE EDGES
CLEAN
ADAPTER
SOLDER
ADAPTER
3
1
B
FINISHED WALL
X
2
32mm
(1-1/4)
TEFLON TAPE
2
1
X
4
INSTALL DOWN TUBE AND
3
VACUUM BREAKER; Fig. 5
1. Place the SPUD FLANGE (1) over the spud on the
Fixture.
2. Thread SPUD COUPLING NUT (2) onto Spud. Make
sure SEAL WASHER (3) and FRICTION WASHER (4)
are installed. Do not tighten fully.
3. Insert the DOWN TUBE (5) into the SPUD
COUPLING NUT (2) and push it down.
Note: If cutting Down Tube (5) to size, note that
Critical Line (C/L) on Vacuum Breaker must
typically be 6" (152mm) above fixture. Consult Code
for details.
5
2
3
4
1
3
1-1 /2 " TO P S PU D
M968699 Rev. 1.15