Alto Shaam TY-72-PL Service Manual

#855 • 7/2005
PRINTED IN U. S .A .
INSTALLATION
OPERATION
AND
MAINTENANCE
MANUAL
HEATED
FULL SERVICE OR
SELF SERVICE
MODEL:
TY-72 Series
W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA
PHONE: 262.251.3800 FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY WEBSITE:
800.558-8744 USA/CANADA 262.251.1907 INTERNATIONAL www.alto-shaam.com
#855 TY-72 Series Operation & Care Manual • 1
The Alto-Shaam Hot Display Case has been thoroughly tested, checked for calibration, and inspected to insure only the highest quality case is provided. When you receive your display case, check for any possible shipping damage and report it at once to the delivering carrier. See Transportation Damage and Claims
section located in this manual.
In order to maintain established National Sanitation Foundation standards, all stationary floor models must be sealed to the floor with a R.T.V. or silastic meeting N.S.F. requirements or have 6" (153mm) unobstructed clearance beneath the unit. Counter and table units must be mounted on legs of a sufficient 4" (102mm) height to provide minimum unobstructed space beneath the unit. Legs are supplied with the unit. Warranty will become null and void if these directions are not followed.
Save all the information and instructions packed inside the display case. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
NOTE
: Any and all claims for warranty must
include the full model and serial number of the display case.
Display case must be installed level. The display case must not be installed in any area where it may be affected by steam, grease, dripping water, high temperatures, or any other severely adverse conditions.
Do not install a heated display case near a cold air source such as a freezer, air conditioning vents, or in any area where outside air fluctuation can affect performance.
If necessary, permanent wiring or electrical outlets for this display case must be installed by an licensed electrician in accordance with local, country or national codes.
An identification tag is permanently mounted on the case. Plug the case into a properly grounded receptacle ONLY. Arcing will occur when connecting or disconnecting the display case unless all controls are in the OFF position. Always position the appliance so the power supply cord is easily accessible in case of emergency.
REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol. If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor.
For 230V units:
To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization­bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol.
PATENT NOS.
3521030 4595247
®
PH
HEATED DISPLAY CASES
®
UNPACKING & SET-UP ELECTRICAL INSTALLATION
®
®
ENSURE THE POWER SOURCE
MATCHES THE VOLTAGE STAMPED
ON CABINET NAMEPLATE
SAMPLE
#855 TY-72 Series Operation & Care Manual 2
OPERATING PROCEDURES
1. DO NOT ADD WATER TO DISPLAY CASE
Halo Heat display cases maintain a constant but gentle temperature and eliminate much of the moisture loss associated with conventional display cases. Because of this gentle heat, it is not necessary to add water to the display case. As a matter of fact, adding water is not recommended since water will accelerate the deterioration of the product, and may damage the unit voiding the warranty.
2. PLACE DIVIDERS AND SERVING PANS IN CASE
Refer to the pan layout diagrams for different types of pan accommodations. A complete pan configuration layout is located in this manual. It
is VERY
important to note,
no matter what type of pan configuration chosen, pan separator bars or divider bars must be used to close all gaps between pans, and all gaps between the pans and the edges of the display case. If these gaps are not closed, heat will escape from the bottom of the case into the display area. As a consequence, heat distribution will be uneven and uniform temperature will be difficult to hold. If needed, additional pan divider bars are available. The supplied self-serve pan inserts with wire grids are for use with pre-packaged foods in the self-serve sections of the units.
3. TURN DISPLAY LIGHTS ON AND SET THE THERMOSTAT(S) AT NUMBER 10 TO PREHEAT
A indicator light will illuminate when the thermostat(s) is (are) turned ON.” The indicator(s) will remain lit as long as the unit is preheating or calling for heat. The unit should be preheated at the 10 setting for a minimum of 30-45 minutes before loading the case with hot food. When preheating is completed, or whenever the unit reaches any temperature set by the operator between
1 and 10, the indicator light(s)
will go
OUT”.
4. LOAD HOT FOODS INTO DISPLAY CASE
Be certain only hot food is transferred into the display case. Before loading food into the case, use a pocket-type meat thermometer to make certain all products have reached an internal temperature of 140° to 160° F (60° to 71°C). If any food product is not at proper serving temperature, use a Halo Heat cooking and holding oven, set at 250° to 275°F (121° to 135°C), or a Combitherm oven to bring the product within the correct temperature range.
Use hand protection when handling hot items.Be certain only hot PREPACKAGED foods in
appropriate heat tested containers are used in the self-service section of the display case.
Do not stack food containers.
5. RESET THERMOSTAT(S) AS NEEDED
After all products are loaded into the display case and the doors are closed, it is necessary to reset the thermostat(s). For fully enclosed sections, reset the thermostat to the number “8” setting. Cases with a self-service section should be maintained between number “9” and number 10 for the self­service section only. THESE SETTINGS WILL NOT NECESSARILY BE FINAL. Since proper temperature range depends on the type of products and the quantities being held, it is necessary to periodically use a pocket thermometer to check each item to make certain the correct temperatures are being maintained. Proper temperature range is between a minimum of 140° and 160° F (60° and 71° C). Normally, this will require a thermostat setting of between number “6” and “8” in fully enclosed cases. Self­service cases or sections will always require a higher thermostat setting.
6. PLACEMENT OF FOOD PROBE
If the unit is equipped with the probe accessory, wipe each probe and probe tip with a disposable alcohol pad to clean and sanitize before using. If the probe is left in its bracket, the LED temperature display will indicate the ambient air temperature inside the case. To place a probe into food kept in the case, remove the probe from the bracket and push the probe tip halfway into the product, positioning the tip at the center of the food mass. If placing into solid foods such as meat roast or poultry breasts, push the probe in from a straight downward position or in from the side to the center position. If placing into a semi­liquid or liquid product, the probe cable will probably need to be secured to keep the probe positioned properly. Do not let the probe tip touch the edges or sides. Tape the probe cable to the lip or edge of the container. Wipe each probe tip with a clean paper towel to remove food debris after each use. Follow by wiping probes with a disposable alcohol pad, and return each probe to the proper bracket position.
7. SERVE FRESH HOT FOOD
Keep hot foods looking fresh. Occasionally stir or rotate food as needed. Serve food products in appropriate heat tested packages or containers. Keep display case doors closed after serving. Wipe spills immediately to assure maximum eye appeal and to ease end of the day cleanup.
OPERATION
#855 TY-72 Series Operation & Care Manual 3
SHEET PAN DIVIDER BAR
ONE-THIRD S IZE PAN
FULL, HALF & THIR D SIZ E - LONG
FULL, HALF & THIR D SIZ E - S HORT
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN FILLER
STANDARD PAN DIVIDER & SEPARATOR BARS
I
TEM NO
.
11046
11047
11317
11318
11319
11320
11357
11732
SIZE (W x L)DESCRIPTIO
N
48 72 96
1
1
2
9
1
2
4
15
3
2
6
21
4
3
1
FULL-S IZE
PAN
ONE-THIRD
SIZE PAN
ONE-HALF
SIZE PAN
ONE-HALF
SIZE PAN
TWO-THIRDS
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
48 Models
72 Models
96 Models
3 PAN ZONES 5 PAN ZONES
7 PAN ZONES
One (1) FULL-S IZE PAN and
One (1) ONE -THIRD S IZE PAN per pan z on e.
48 MODE LS :
72 MODE LS :
96 MODELS:
Up to 3 Full-Siz e P ans with 3 One -Third S ize Pa ns
Up to 5 Full-Siz e P ans with 5 One -Third S ize Pa ns
Up to 7 Full-Siz e P ans with 7 One -Third S ize Pa ns
Two (2) ONE -HALF SIZ E P ANS and
One (1) ONE -THIRD S IZE PAN per pan zone.
48 MODELS:
72 MODELS:
96 MODELS:
Up to 6 One-Half Siz e Pans with 3 One-Third Siz e Pans
Up to 10 One-Half S ize Pans with 5 One-Third Size Pans
Up to 14 One-Half S ize Pa ns with 7 One-Third Siz e Pans
One (1) TWO-THIR DS SIZE PAN and
Two (2) ONE -THIRD SIZE PANS per pan zone.
48 MODE LS :
72 MODE LS :
96 MODELS:
Up to 3 Two-Thirds Size Pans with 6 One -Third S ize Pa ns
Up to 5 Two-Thirds Size Pans with 10 One-Third Size Pans
Up to 7 Two-Thirds Size Pans with 14 One-Third Size Pans
Four (4) ONE -THIR D SIZE PANS per pan zone.
48 MODELS:
72 MODELS:
96 MODE LS :
Up to 12 One-Third S ize Pa ns per display case
Up to 20 One-Third S ize Pa ns per display case
Up to 28 One-Third S ize Pa ns per display case
ONE-THIRD
SIZE PAN
MODELS
PAN CONFIGURATIONS HEATED DISPLAY CASES
1-3/8" x 27-13/16" (35 mm x 706 mm)
3-1/4" x 7"
1" x 27-7/8"
1" x 13"
3-1/4" x 27-3/16"
1-3/4" x 17-3/4"
5-29/32" x 27-13/16"
3-3/4" x 27-13/16"
(83 mm x 178 mm)
(25 mm x 708 mm)
(25 mm x 330 mm)
(83 mm x 706 mm)
(45 mm x 451 mm)
(150 mm x 706 mm)
(95 mm x 706 mm)
Note: Additional Pan Separator Bars may be required to accommodate maxium capacities.
#855 TY-72 Series Operation & Care Manual 4
FULL-SIZE PA N
ONE-HALF SIZE PA N
TWO-THIRDS SIZE PA N
ONE-T HIR D SIZE PA N
FULL-SIZE SHEET PA N
12" x 20" x 2-1/2"
12" x 10" x 2-1/2"
12" x 14" x 2-1/2"
12" x 6" x 2-1/2"
18" x 26" x 1"
325 mm x 530 mm x 65 mm
325 mm x 265 mm x 65 mm
325 mm x 352 mm x 65 mm
325 mm x 176 mm x 65 mm
N/A
GN 1/1
GN 1/2
GN 2/3
GN 1/3
STANDARD PA N SIZES
S TANDARD P AN DIVIDER & S E P AR ATOR BARS
Item No.
11046
11047
11317
11318
11319
11320
11357
11732
SHEET PAN DIVIDER BAR
ONE-THIRD SI ZE PAN
FULL, HALF & THIRD SIZE - LONG
FULL, HALF & THIRD SIZE - SHOR T
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
S IZ E (W x L) DE SCR IPTIO N
72
96 Models
4
15
3
2
6
21
4
3
1
One (1) FULL-SIZE PAN and
One (1) ONE-THIRD SIZE P AN per pa n zone .
72 MODELS: Up to 3 Fu ll-Size Pans with
3 One -Third Size Pans per display ca se
96 MODELS: Up to 5 Fu ll-Size Pans with
5 One -Third Size Pans per display ca se
Two (2) ONE-HALF SIZE PANS a nd
One (1) ONE-THIRD SIZE P AN per pa n zone .
72 MODELS: Up to 6 One -Half Size Pans with
3 One -Third Size Pans pe r displa y case
96 MODELS: Up to 10 One -Half Size Pans with
5 One -Third Size Pans per display case
One (1) TWO-THIRDS SIZE PAN and
Two ( 2) ONE-THIRD S IZE PANS per pa n zone .
72 MODELS: Up to 3 Two-Third s S ize P ans with
6 One -Third Size Pa ns per displa y case
96 MODELS: Up to 5 Two-Third s S ize P ans with
10 One -Third Size Pa ns per displa y case
Four ( 4) ONE-THIRD S IZE PANS per pan zone .
72 MODELS: Up to 12 One-Third S ize Pans
per display case
96 MODELS: Up to 20 One-Third S ize Pans
per display case
FULL-SIZE SHEE T PANS: 18" x 26" x 1"
72 MODELS: 2 S he et Pa ns per displa y ca se 96 MODELS: 3 S he et Pa ns per displa y ca se
SHEET PANS
(NO T SHOWN)
PAN LAYOUT
DIAGRAM
3 P AN ZONE S
5 P AN ZONE S
ONE-HALF
SIZE PAN
ONE-HALF
SIZE PAN
TWO-T HIR DS
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
SELF-S E RVE
PAN ZONE
PAN SIZE : ITEM #1405
(429 mm x 673 mm x 51 mm )
FULL-SIZE
PAN
NOTE: ADDITIONAL P AN SE P ARATOR BARS MAY BE RE QUIRE D
TO ACCOMMODATE MAXI MUM CAPACITIES .
TYSYS-72/PL & TYSYS-72/PR
TYSYS-96/PL TYSYS-96/PR
PAN CONFIGURATIONS SELF-SERVE HOT DISPLAY CASES
16-7/8" x 26-1/2 x 2"
1-3/8" x 27-13/16" (35 mm x 706 mm)
3-1/4" x 7" (83 mm x 178 mm)
1" x 27-7/8" (25 mm x 708 mm)
3-1/4" x 27-3/16" (83 mm x 706 mm)
1-3/4" x 17-2/4" (45 mm x 451 mm)
1" x 13" (25 mm x 330 mm)
5-29/32" x 27-13/16" (150 mm x 706 mm)
3-3/4" x 27-13/16" (95 mm x 706 mm)
Models
#855 TY-72 Series Operation & Care Manual 5
SHEET PAN CONFIGURATIONS HOT DISPLAY CASES
48 Models
72 Models
96 Models
2 SHEET PAN ZONES
3 SHEET PAN
ZONES
4 SHEET PAN
ZONES
ONE-THIRD
SIZE PAN
ONE-HALF
SIZE PAN
ONE-HALF
SIZE PAN
72 MODELS
3 Full-size Sheet Pans per display case
48 MODELS
2 Full-size Sheet Pans per display case
OR 1 Full-size Sheet Pan 2 One-half Size Pans
3 One-third Size Pans
96 MODELS
4 Full-size Sheet Pans per display case
FULL-SIZE
SHEET PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
STANDARD PAN DIVIDER & SEPARATOR BARS
I
TEM NO
.
11046
11047
11317
11318
11319
11320
11357
11732
1865
SHEET PAN DIVIDER BAR
ONE-THIRD SIZE PAN
FULL, HALF & THIRD SIZE - LONG
FULL, HALF & THIRD SIZE - SHORT
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN FILLER
GASTRONORM DIVIDER (220V)
SIZE (W x L)
1-3/8" x 27-13/16"
3-1/4" x 7"
1" x 27-7/8"
1" x 13"
3-1/4" x 27-3/16"
1-3/4" x 17-3/4"
5-29/32" x 27-13/16"
3-3/4" x 27-13/16"
7/8" x 27-7/8"
DESCRIPTION
48 MODELS 72 MODELS
96 MODELS
1
1
2
9
1
2
2
4
15
3
2
4
6
21
4
3
1
6
(35mm x 706mm)
(83mm x 178mm)
(25mm x 708mm)
(25mm x 330mm)
(83mm x 706mm)
(45mm x 451mm)
(150mm x 706mm)
(95mm x 706mm)
(22mm x 708mm)
#855 TY-72 Series Operation & Care Manual 6
OPERATION
Chefs, cooks and other specialized food service personnel employ varied methods of cooking. Proper holding temperatures for a specific food product must be based on the moisture content of the product, product density, volume, and proper serving temperatures. Safe holding temperatures must also be correlated with palatability in determining the length of holding time for a specific product.
Halo Heat maintains the maximum amount of product moisture content without the addition of water, water vapor, or steam. Maintaining maximum natural product moisture preserves the natural flavor of the product and provides a more genuine taste. In addition to product moisture retention, the gentle properties of Halo Heat maintain a consistent temperature throughout the cabinet without the necessity of a heat distribution fan, thereby preventing further moisture loss due to evaporation or dehydration.
When product is removed from a high temperature cooking environment for immediate transfer into equipment with the lower temperature required for hot food holding, condensation can form on the outside of the product and on the inside of plastic containers used in self-service applications. Allowing the product to release the initial steam and heat produced by high temperature cooking can alleviate this condition. To preserve the safety and quality of freshly cooked foods however, a maximum of 1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product.
Most Halo Heat holding equipment is provided with a thermostat control between 60° and 200°F (16° to 93°C). If the unit is equipped with vents, close the vents for moist holding and open the vents for crisp holding.
If the unit is equipped with a thermostat indicating a range of between 1 and 10, use a metal-stemmed indicating thermometer to measure the internal temperature of the product(s) being held. Adjust the thermostat setting to achieve the best overall setting based on internal product temperature.
HOLDING TEMPERATURE RANGE
MEAT FAHRENHEIT CELSIUS
BEEF ROAST — Rare 140°F60°C
BEEF ROAST Med/Well Done 16 0°F71°C
BEEF BRISKET 160°— 175°F71°— 79°C
CORN BEEF 160°— 175°F71°— 79°C
PASTRAMI 160°— 175°F71°— 79°C
PRIME RIB — Rare 140°F60°C
STEAKS Broiled/Fried 140°— 160°F60°— 71°C
RIBS Beef or Pork 160°F71°C
VEAL 160°— 175°F71°— 79°C
HAM 160°— 175°F71°— 79°C
PORK 160°— 175°F71°— 79°C
LAMB 160°— 175°F71°— 79° C
POULTRY
CHICKEN Fried/Baked 160°— 175° F71°— 79°C
DUCK 160°— 175° F71°— 79°C
TURKEY 160°— 175° F71°— 79°C
GENERAL 160°— 175° F71°— 79°C
FISH/SEAFOOD
FISH Baked/Fried 160°— 175° F71°— 79°C
LOBSTER 160°— 175°F71°— 79°C
SHRIMP Fried 160°— 175°F71°— 79°C
BAKED GOODS
BREADS/ROLLS 120°— 140° F49°— 60°C
MISCELLANEOUS
CASSEROLES 160°— 175° F71°— 79°C
DOUGH Proofing 80°— 100° F27°— 38° C
EGGS Fried 150°— 160° F66°— 71°C
FROZEN ENTREES 160°— 175° F71°— 79°C
HORS D'OEUVRES 160°— 180°F71°— 82°C
PASTA 160°— 180° F71°— 82°C
PIZZA 160°— 180°F71°— 82°C
POTATOES 180° F82° C
PLATED MEALS 180°F82° C
SAUCES 140°— 200°F60°— 93°C
SOUP 140°— 200° F60°— 93°C
VEGETABLES 160°— 175° F71°— 79°C
The holding temperatures listed are suggested guidelines only.
GENERAL HOLDING GUIDELINES
#855 TY-72 Series Operation & Care Manual 7
Hood glass extended to the full upright
position is stabilized through the use
of gas struts designed for the full
load bearing weight. These struts
could weaken or fail due to wear,
environmental conditions or aging.
Operators should be aware of any decrease in effort to lift the hood and initiate an immediate gas strut safety check.
DO NOT LIFT THE HOOD IN THIS CONDITION.
SAFETY ALERT
This units performance has been
optimized using the factory provided
bulbs. These bulbs should be
replaced with an exact replacement or with a factory recommended replacement. These bulbs have been treated to resist breakage and must be replaced with similarly treated bulbs in order to maintain compliance with NSF standards. Do not over-tighten bulbs in their receptacles as this can cause damage to the bulb filament.
The cleanliness and appearance of this equipment will contribute considerably to operating efficiency and savory, appetizing food. Good equipment that is kept clean works better and lasts longer.
1. CLEAN THE PROBES DAILY
If the display case is supplied with probes, remove all food soil from probes. Wipe entire probe and cable assembly with warm detergent solution and a clean cloth. Remove detergent by wiping each probe and cable with clean rinse water and a cloth. Wipe probes with disposable alcohol pad or sanitizing solution recommended for food contact surfaces. Allow probe and cable to air dry in probe holding bracket.
2. THOROUGHLY CLEAN THE UNIT DAILY
A. Turn lights and adjustable thermostat(s) to the
OFF position, and disconnect unit from power source.
B. Remove, cover or wrap, and store unused
products under refrigeration.
C. Clean the interior metal surfaces of the cabinet
with a damp clean cloth and any good commercial detergent or grease solvent at the recommended strength. Use a plastic scouring pad or oven cleaner for difficult areas. Rinse well to remove all residue and wipe dry.
NOTE: Avoid the use of abrasive cleaning
compounds, chloride based cleaners, or cleaners containing quaternary salts. Never use hydrochloric acid (muriatic acid) on stainless steel.
D. Clean the glass with a window cleaner. The
sliding glass doors are removable allowing for easier cleaning.
E. To help maintain the protective film coating on
polished stainless steel, clean the exterior of the unit with a cleaner recommended for stainless steel surfaces. Spray the cleaning agent on a clean cloth and wipe with the grain of the stainless steel.
Always follow appropriate state or local health (hygiene) regulations regarding all applicable cleaning and sanitation requirements for equipment.S
DO NOT USE IF CONTROLS ARE NOT PROPERLY FUNCTIONING
Refer to the Trouble Shooting Guide located in this manual or call an authorized service technician.
CHECK OVERALL CONDITION ONCE A MONTH
Check the case and related cabinets once a month for physical damage and loose screws. Correct any problems before they begin to interfere with the operation of the unit.
CARE AND CLEANING
AT NO TIME SHOULD THE INSIDE OR
THE OUTSIDE OF THE OVEN BE
WASHED DOWN, FLOODED WITH
WATER, OR LIQUID SOLUTION. DO
NOT USE WATER JET TO CLEAN.
NEVER STEAM CLEAN.
SEVERE
DAMAGE OR ELECTRICAL HAZARD
COULD RESULT.
WARRANTY BECOMES VOID IF
CABINET IS FLOODED.
#855 TY-72 Series Operation & Care Manual 8
Food flavor and aroma are usually so closely related that it is difficult, if not impossible, to separate them. There is also an important, inseparable relationship between cleanliness and food flavor. Cleanliness, top operating efficiency, and appearance of equipment contribute considerably to savory, appetizing foods. Good equipment that is kept clean, works better and lasts longer.
Most food imparts its own particular aroma and many foods also absorb existing odors. Unfortunately, during this absorption, there is no distinction between GOOD and BAD odors. The majority of objectionable flavors and odors troubling food service operations are caused by bacteria growth. Sourness, rancidity, mustiness, stale or other OFF flavors are usually the result of germ activity.
The easiest way to insure full, natural food flavor is through comprehensive cleanliness. This means good control of both visible soil (dirt) and invisible soil (germs). A thorough approach to sanitation will provide essential cleanliness. It will assure an attractive appearance of equipment, along with maximum efficiency and utility. More importantly, a good sanitation program provides one of the key elements in the prevention of food-borne illnesses.
A controlled holding environment for prepared foods is just one of the important factors involved in the prevention of food-borne illnesses. Temperature monitoring and control during receiving, storage, preparation, and the service of foods are of equal importance.
The most accurate method of measuring safe temperatures of both hot and cold foods is by internal product temperature. A quality thermometer is an effective tool for this purpose, and should be routinely used on all products that require holding at a specific temperature.
A comprehensive sanitation program should focus on the training of staff in basic sanitation procedures. This includes personal hygiene, proper handling of raw foods, cooking to a safe internal product temperature, and the routine monitoring of internal temperatures from receiving through service.
Most food-borne illnesses can be prevented through proper temperature control and a comprehensive program of sanitation. Both these factors are important to build quality service as the foundation of customer satisfaction. Safe food handling practices to prevent food-borne illness is of critical importance to the health and safety of your customers. HACCP, an acronym for Hazard Analysis (at) Critical Control Points, is a quality control program of operating procedures to assure food integrity, quality, and safety. Taking steps necessary to augment food safety practices are both cost effective and relatively simple. While HACCP guidelines go far beyond the scope of this manual, additional information is available by contacting:
Center for Food Safety and Applied Nutrition
Food and Drug Administration
1-888-SAFEFOOD
SANITATION
INTERNAL FOOD PRODUCT TEMPERATURES
HOT FOODS
DANGER ZONE 40° TO 140°F(4° TO 60° C)
CRITICAL ZONE 70° TO 120°F (21° TO 49° C)
SAFE ZONE 140° TO 165°F (60° TO 74° C)
COLD FOODS
DANGER ZONE ABOVE 40°F (ABOVE 4°C)
SAFE ZONE 36° F TO 40°F(2°C TO 4°C)
FROZEN FOODS
DANGER ZONE ABOVE 32°F (ABOVE 0°C)
CRITICAL ZONE 0° TO 32°F (-18° TO 0° C)
SAFE ZONE 0°F
OR BELOW (-18° C OR BELOW)
Loading...
+ 20 hidden pages