Alto Shaam TY-72, TYSYS-72 Operation Manual

#855 • 12/2002
PRINTED IN U. S .A .
OPERATION and CARE MANUAL
PHONE: 262.251.3800 FAX: 262.251.7067, 800.329.8744 U . S . A . ONLY WEBSITE:
800.558.8744
U . S . A ./CANADA 262.251.1907 INTERNATIONAL www.alto-shaam.com
W164 N9221 Water Street ●P.O. Box 450 ●Menomonee Falls, Wisconsin 53052-0450 U.S.A.
®
COOK/HOLD/SERVE SYSTEMS
HEATED DISPLAY CASE
MODELS: TY-72 TYSYS-72
TY-72/P TYSYS-72/P TY-72/PL TYSYS-72/PL TY-72/PR TYSYS-72/PR
The Alto-Shaam Hot Display Case has been thoroughly tested, checked for cali­bration, and inspected to insure only the highest quality cabinet is provided. When you receive your display case, check for any possible shipping damage and report it at once to the delivering carrier.
See
Transportation Damage and Claims section located in this manual.
In order to maintain established National Sanitation Foundation standards, all stationary floor models must be sealed to the floor with a R.T.V. or silastic meeting N.S.F. requirements or have 6" (153mm) unobstructed clearance beneath the unit. Counter and table units must be mounted on legs of a sufficient 4" (102mm) height to provide minimum unobstructed space beneath the unit. Legs are supplied with the unit. Warranty will become null and void if these directions are not followed.
Save all the information and instructions packed inside the display case. Complete and return the warranty card to the factory as soon as possible to assure prompt service in the event of a warranty parts and labor claim.
NOTE: Any and all claims for warranty must include the full model and
serial number of the display case.
The unit must be installed by an licensed electrician in accordance with local, country or national codes.
1. An identification tag is permanently mounted on the case.
2. Plug the case into a properly grounded receptacle ONLY,
making sure the cord is accessible in case of an emergency. Arcing will occur when connecting or disconnecting the display case unless all controls are in the OFF position.
3. REGARDING INTERNATIONAL STANDARD UNITS:
If the unit is not equipped with flexible cord with plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol. If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor.
OPERATIONAL PROCEDURES
1. DO NOT ADD WATER TO THE CASE
Halo Heat display cases maintain a constant but gentle temperature and eliminate much of the moisture loss associated with conventional display cases. Because of this gentle heat, it is not necessary to add water to the deli case. As a matter of fact,
adding water is not recommended
since water will accelerate the deterioration of the product,
and may damage the case and void the warranty.
2. PLACE DIVIDERS and SERVING PANS IN CASE
Refer to the pan layout diagrams for different types of pan accommodations. A complete pan configuration layout is located in this manual. It is VERY important to note, no matter what type of pan configuration chosen, pan separator bars or divider bars must be used to close all gaps between pans, and all gaps between the pans and the edges of the display case. If these gaps are not closed, heat can be pulled out of the bottom of the case into the display area. As a consequence, heat distribution can be uneven and uniform temperature will be difficult to hold. If needed, additional pan divider bars are available.
3. TURN POWER and/or BREAKER SWITCH ON
4.
SET THERMOSTATS AT NUMBER 10
The display case should be preheated at the number 10 setting for a minimum of
30 minutes before loading with food. An indicator light will illuminate when the thermostats are turned ON and will remain lit as long as the unit is preheating or calling for heat. When preheating is completed, or whenever the unit reaches any temperature set by the operator between 1 and 10, the indicators will go OUT.
5. LOAD HOT FOODS - TURN LIGHTS ON
Be certain only hot food is transferred into the display case. Before loading food into the unit, use a pocket­type meat thermometer to make certain all products have reached an internal temperature of 140° to 160°F (60° to 71°C). If any food product is not at proper serving temperature, use a Halo Heat cooking and holding oven, set at 250° to 275°F (121° to 135°C), or a Combitherm oven to bring the product within the correct temperature range.
Use hand protection when handling hot items.Be certain only hot PREPACKAGED foods in
appropriate heat tested containers are used in the self service section of the display case.
Do not stack food containers.
6. RESET THERMOSTAT AS NEEDED
After all products are loaded into the display case, and the doors are closed, it is necessary to reset the thermostat. For fully enclosed cases, reset the thermostat to the number 8 setting
. For self-service cases, the thermostat should be maintained at the number 9 or 10 setting. Cases with a self-service section should also be maintained at number 9 or 10 at the self-service section only.
THESE
SETTINGS WILL NOT NECESSARILY BE FINAL.
Since proper temperature range depends on the type of products and the quantities being held, it is necessary to periodically use a thermometer to check each item to make certain the correct temperatures are being maintained. Proper temperature range is between 140°F and 160°F (60°C and 71°C). Normally, this will require a thermostat setting between 6 and 8 in fully enclosed cases. Self­service cases or sections will always require a higher thermostat setting.
7. MULTIPLE TIMER/PROBE OPTION
A multiple timer/probe system is available for this case. This system is a timer-based food management system, utilized with HACCP programs, that ensures proper rotation, food integrity, safety and quality. The multiple-
#855 Operation & Care Manual • 1
ENSURE POWER SOURCE MATCHES VOLTAGE
STAMPED ON NAMEPLATE OF UNIT
HEATED DISPLAY CASES
UNPACKING & SET-UP
ELECTRICAL INSTALLATION
®
SERIAL NUMBER AND WARRANTY CODE
IDENTIFICATION MODEL NUMBER
MODEL
SERIAL NO. WATTS
VOLTS
MAXIMUM RATED VOLTAGE MAXIMUM RATED FREQUENCY
EXAMPLE
xxx-xx
xxxx-xx xxxx
ALTO-SHAAM INC. MILW. WI. PAT. NO. 3521030
AC
1 PH
MAXIMUM RATED
WATTAGE
xx
HZxxx
#855 Operation & Care Manual • 2
timer station keys correspond to various pan locations in the display case. Contact factory for more information.
8. PLACEMENT OF FOOD PROBE (OPTION)
If the unit is equipped with the probe accessory, wipe each probe and probe tip with a disposable alcohol pad to clean and sanitize before using. If the probe is left in its bracket, the LED temperature display will indicate the ambient air temperature inside the case. To place a probe into food kept in the case, remove the probe from the bracket and push the probe tip halfway into the product, positioning the tip at the center of the food mass.
When placing in solid foods such as meat roast or poultry breasts, push the probe in from a straight downward position or in from the side to the center position. When placing in a semi-liquid or liquid product, the probe cable will probably need to be secured to keep the probe positioned properly. Do not let the probe tip touch the edges or side of the container. Tape the probe cable to the lip or edge of the container. Wipe each probe tip with a clean paper towel to remove food debris after each use. Follow by wiping probes with a disposable alcohol pad. Return each probe to the proper bracket position.
9. SERVE FRESH HOT FOOD
Keep hot foods looking fresh. Occasionally stir or rotate foods as needed. Serve products in the proper package or container. Keep doors closed after serving. Wipe spills immediately to assure maximum eye appeal, and to ease end of-the-day cleanup.
The cleanliness and appearance of this unit will contribute considerably to operating efficiency and savory, appetizing food. Good equipment kept clean works better and lasts longer.
THOROUGHLY CLEAN UNIT DAILY
A. Turn lights and adjustable thermostat(s) to the OFF position,
and disconnect unit from power source. Let unit cool.
B. Remove, cover or wrap, and store unused products under
refrigeration.
C. Clean the interior metal surfaces of the cabinet with a
damp cloth and any good alkaline or alkaline chlorinated based commercial detergent or grease solvent at the recommended strength. Use a plastic scouring pad or oven cleaner for difficult areas. Avoid the use of abrasive cleaning compounds, chloride based cleaners, or cleaners containing quaternary salts. Rinse carefully to remove all residue and wipe dry.
NOTE: Never use hydrochloric acid (muriatic acid) on
stainless steel. D. Clean the glass with a window cleaner. E. To help maintain the protective film coating on polished
stainless steel, clean the exterior of the unit with a cleaner recommended for stainless steel surfaces. Spray the cleaning agent on a clean cloth and wipe with the grain of the stainless steel.
CLEAN PROBES DAILY
Remove all food soil from probes. Wipe entire probe and
cable assembly with warm detergent solution and a clean cloth. Remove detergent by wiping each probe and cable with clean rinse water and a cloth. Wipe probes with disposable alcohol pad or sanitizing solution recommended for food contact surfaces. Allow probe and cable to air dry in probe holding bracket.
Always follow appropriate state or local health (hygiene) regulations regarding all applicable cleaning and sanitation requirements for equipment.
Remember to turn power and/or breaker switches
ON
before use.
CARE and CLEANING
At no time should the inside or outside of the unit be washed down, flooded with water or liquid solution. Do not use water jet to clean. NEVER STEAM CLEAN. Severe damage or electrical hazard could result, voiding the warranty.
Disconnect the unit from the power source
before cleaning or servicing.
Hood glass extended to the full upright
position is stabilized through the use
of gas struts designed for the full
load bearing weight. These struts
could weaken or fail due to wear,
environmental conditions or aging.
Operators should be aware of any decrease in effort to lift the hood and initiate an immediate gas strut safety check.
DO NOT LIFT THE HOOD IN THIS CONDITION.
!
CAUTION
SHEET PAN CONFIGURATIONS HOT DISPLAY CASES
48 Models
2 SHEET PAN ZONES
FULL-SIZE
SHEET PAN
2 Full-size Sheet Pans per display case
1 Full-size Sheet Pan 2 One-half Size Pans 3 One-third Size Pans
48 MODELS
OR
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
ONE-HALF
SIZE PAN
ONE-HALF
SIZE PAN
ONE-THIRD
SIZE PAN
72 Models
3 SHEET PAN
ZONES
72 MODELS
3 Full-size Sheet Pans per display case
96 Models
4 SHEET PAN
ZONES
96 MODELS
4 Full-size Sheet Pans per display case
#855 Operation & Care Manual • 3
(35mm x 706mm)
(83mm x 178mm)
(25mm x 708mm)
(25mm x 324mm)
(83mm x 706mm)
(45mm x 451mm)
(150mm x 706mm)
(95mm x 706mm)
(22mm x 708mm)
SHEET PAN DIVIDER BAR
ONE-THIRD SIZE PAN
FULL, HALF & THIRD SIZ E - LONG
FULL, HALF & THIRD SIZ E - SHORT
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN FILLER
GASTRONORM DIVIDER (220V)
1-3/8" x 27-13/16"
3-1/4" x 7"
1" x 27-7/8"
1" x 12-3/4"
3-1/4" x 27-3/16"
1-3/4" x 17-3/4"
5-29/32" x 27-13/16"
3-3/4" x 27-13/16"
7/8" x 27-7 /8"
STANDARD PAN DIVIDER & SEPARATOR BARS
ITEM NO .
11046
11047
11317
11318
11319
11320
11357
11732
1865
SIZE (W x L)DESCRIPTION
48 72 96
1
1
2
9
1
2
2
4
15
3
2
4
6
21
4
3
1
6
PAN CONFIGURATIONS DISPLAY CASES
NOTE: ADDITIONAL PAN
SEPARATOR BARS MAY
BE REQUIRED TO
ACCOMMODATE MAXIMUM
CAPACITIES.
FULL-S IZE
PAN
ONE-THIRD
SIZE PAN
ONE-HALF
SIZE PAN
ONE-HALF
SIZE PAN
TWO-THIRDS
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
48 Models
72 Models
96 Models
3 PAN ZONES 5 PAN ZONES
7 PAN ZONES
One (1) FULL-SIZE PAN and
One (1) ONE-THIRD SIZE PAN per pan zone.
— 48 MODELS:
— 72 MODELS:
— 96 MODELS:
Up to 3 Full-Size Pans with 3 One-Third Size Pans
Up to 5 Full-Size Pans with 5 One-Third Size Pans
Up to 7 Full-Size Pans with 7 One-Third Size Pans
Two (2) ONE-HALF SIZE PANS and
One (1) ONE-THIRD SIZE PAN per pan zone.
— 48 MODELS:
— 72 MODELS:
— 96 MODELS:
Up to 6 One-Half Size Pans with 3 One-Third Size Pans
Up to 10 One-Half Size Pans with 5 One-Third Size P ans
Up to 14 One-Half Size Pans with 7 One-Third Size P ans
One (1) TWO-THIRDS SIZE PAN and
Two (2) ONE-THIRD SIZE PANS per pan z one.
— 48 MODELS:
— 72 MODELS:
— 96 MODELS:
Up to 3 Two-Thirds Size P ans with 6 One-Third Size Pans
Up to 5 Two-Thirds Size P ans with 10 One-T hird Size Pans
Up to 7 Two-Thirds Size P ans with 14 One-T hird Size Pans
Four (4) ONE-THIR D SIZE PANS per pan zone.
— 48 MODELS:
— 72 MODELS:
— 96 MODELS:
Up to 12 One-Third Size P ans per display case
Up to 20 One-Third Size P ans per display case
Up to 28 One-Third Size P ans per display case
ONE-THIRD
SIZE PAN
MODELS
#855 Operation & Care Manual • 4
FULL-SIZE PAN
ONE-HALF SIZE PAN
TWO-THIRDS SIZE PAN
ONE-T HIRD SIZE PA N
FULL-SIZE SHEET PA N
12" x 20" x 2-1/2"
12" x 10" x 2-1/2"
12" x 14" x 2-1/2"
12" x 6" x 2-1/2"
18" x 26" x 1"
325mm x 530mm x
325mm x 265mm x
325mm x 352mm x
325mm x 176mm x
N/A
65mm
65mm
65mm
65mm
GN 1/1
GN 1/2
GN 2/3
GN 1/3
STANDARD PA N SIZES
TYSYS-72/PL & TYSYS-72/PR
TYSYS-96/PL
TYSYS-96/PR
1-3/8" x 27-13/16"
3-1/4" x 7"
1" x 27-7/8"
1" x 12-3/4"
3-1/4" x 27-3/16"
1-3/4" x 17-3/4"
5-29/32" x 27-13/16"
3-3/4" x 27-13/16"
7/8" x 27-7/8"
STANDARD P AN DIV IDER & SEPARATOR BARS
Item No.
11046
11047
11317
11318
11319
11320
11357
11732
1865
SHEET PAN DIVIDER BAR
ONE-THIRD SIZE PAN
FULL , HALF & TH IRD SIZE - L ONG
FULL, HALF & THIRD SIZE - SHOR T
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
SHEET PAN DIVIDER BAR
GASTRONORM DIVIDER (220V)
S IZE (W x L) DESCRIP TION
72 MODE LS
96 MODE LS
4
15
3
2
4
6
21
4
3
1
6
(35mm x 706mm)
(83mm x 178mm)
(25mm x 708mm)
(25mm x 324mm)
(83mm x 706mm)
(45mm x 451mm)
(150mm x 706mm)
(95mm x 706mm)
(22mm x 708mm)
One (1) FULL-SIZE PAN and
One (1) ONE-THIRD SIZE PAN per pa n zone.
72 MODELS: Up to 3 Full-Size Pans with
3 One-Third Size Pa ns per display case
96 MODELS: Up to 5 Full-Size Pan s with
5 One-Third Size Pa ns per display case
Two (2) ONE-HALF SIZE PANS and
One (1) ONE-THIRD SIZE PAN per pan zone.
72 MODELS: Up to 6 One-Half Size Pans with
3 One-Third Size Pans per display case
96 MODELS: Up to 10 One-Half Size Pans with
5 One-Third Size Pans per display case
One (1) TWO-THIRDS SIZE P AN and
Two (2) ONE-THIRD SIZE PANS per pan zone.
72 MODELS: Up to 3 Two-Thirds Size Pans with
6 One-Third
Size Pa ns pe r display case
96 MODELS: Up
to 5 Tw o-Thirds Size Pans with
10 One-Third Size Pans per display case
Four (4) ONE-THIRD SIZE PANS pe
r pan zone.
72 MODELS: Up to 12 One-Third Size
Pans
per display ca se
96 MODELS: Up to 20 One-Third Si
ze Pans
per display ca se
FULL-SIZE SHEET PANS: 18" x 26" x 1"
72 MODELS: 2 Sh eet P ans per display case 96 MODELS: 3 Sh eet P ans per display case
SHEET PANS
(NOT SHO WN)
PAN LAYO UT
DIAGRAM
PAN CONFIGURATIONS • SELF-SERVE HOT DISPLAY CASES
3 PAN ZONES
5 PAN ZONES
ONE-HAL F
SIZE PAN
ONE-HAL F
SIZE PAN
TWO-THIRDS
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
ONE-THIRD
SIZE PAN
SELF-SERVE
PAN ZONE
PAN SIZE: ITEM #1405
16-7/8" x 26-1/2" x 2"
(429 mm x 673 mm x 51 mm)
FULL -SIZE
PA N
NOTE: ADDITIONAL PAN SEPARATOR BARS MAY BE REQUIRED
TO ACCOMMODATE M AXIMUM CAPACITIES .
#855 Operation & Care Manual • 5
S Food flavor and aroma are usually so closely related
that it is difficult, if not impossible, to separate them. There is also an important, inseparable relationship between cleanliness and food flavor. Cleanliness, top operating efficiency, and appearance of equipment contribute considerably to savory, appetizing foods. Good equipment that is kept clean, works better and lasts longer.
Most food imparts its own particular aroma and many foods also absorb existing odors. Unfortunately, during this absorption, there is no distinction between
GOOD and BAD odors. The majority of objectionable flavors and odors troubling food service operations are caused by bacteria growth. Sourness, rancidity, mustiness, stale or other
OFF
flavors are usually the result of germ activity.
The easiest way to insure full, natural food flavor is through comprehensive cleanliness. This means good control of both visible soil (dirt) and invisible soil (germs). A thorough approach to sanitation will provide essential cleanliness. It will assure an attractive appearance of equipment, along with maximum efficiency and utility. More importantly, a good sanitation program provides one of the key elements in the prevention of food-borne illnesses.
A controlled holding environment for prepared foods is just one of the important factors involved in the prevention of food-borne illnesses. Temperature monitoring and control during receiving, storage, preparation, and the service of foods are of equal importance.
The most accurate method of measuring safe temper­atures of both hot and cold foods is by internal product temperature.
A quality thermometer is an effective tool for this purpose, and should be routinely used on all products that require holding at a specific temperature.
A comprehensive sanitation program should focus on the training of staff in basic sanitation procedures. This includes personal hygiene, proper handling of raw foods, cooking to a safe internal product temperature, and the routine monitoring of internal temperatures from receiving through service.
Most food-borne illnesses can be prevented through proper temperature control and a comprehensive program of sanitation. Both these factors are important to build quality service as the foundation of customer satisfaction. Safe food handling practices to prevent food-borne illness is of critical importance to the health and safety of your customers. HACCP, an acronym for Hazard Analysis (at) Critical Control Points, is a quality control program of operating procedures to assure food integrity, quality, and safety. Taking steps necessary to augment food safety practices are both cost effective and relatively simple. While HACCP guidelines go far beyond the scope of this manual, additional information is available by contacting the USDA/FDA Food-borne Illness Education Information Center at (301)504-6803.
Chefs, cooks and other specialized food service personnel employ varied methods of cooking. Proper holding temperatures for a specific food product must be based on the moisture content of the product, product density, volume, and proper serving temperatures. Safe holding temperatures must also be correlated with palatability in determining the length of holding time for a specific product.
Halo Heat maintains the maximum amount of product moisture content without the addition of water, water vapor, or steam. Maintaining maximum natural product moisture preserves the natural flavor of the product and provides a more genuine taste. In addition to product moisture retention, the gentle properties of Halo Heat maintain a consistent temperature throughout the cabinet without the necessity of a heat distribution fan, thereby preventing further moisture loss due to evaporation or dehydration.
In an enclosed holding environment, too much moisture content is a condition which can be relieved. A product achieving extremely high temperatures in preparation must be allowed to decrease in temperature before being placed in a controlled holding atmosphere. If the product is not allowed to decrease in temperature, excessive condensation will form increasing the moisture content on the outside of the product.
Most Halo Heat Holding equipment is provided with a thermostat control between 60° and 200°F (16° to 93°C). If the unit is equipped with vents, close the vents for moist holding and open the vents for crisp holding.
If the unit is equipped with a thermostat indicating a range of between 1 and 10, use a metal-stemmed indicating thermometer to measure the internal temperature of the product(s) being held. Adjust the thermostat setting to achieve the best overall setting based on internal product temperature.
HOLDING TEMPERATURE RANGE
MEAT FAHRENHEIT CELSIUS
BEEF ROAST — Rare 140°F60°C BEEF ROAST Med/Well Done 16 0°F71°C BEEF BRISKET 160°— 175° F71°— 79° C CORN BEEF 160°— 175° F71°— 79° C PASTRAMI 160°— 175° F71°— 79° C PRIME RIB — Rare 140°F60°C STEAKS Broiled/Fried 140°— 160° F60°— 71° C RIBS Beef or Pork 160°F71°C VEAL 160°— 175° F71°— 79° C HAM 160°— 175° F71°— 79° C PORK 160°— 175° F71°— 79° C LAMB 160°— 175°F71°— 79° C
POULTRY
CHICKEN Fried/Baked 160°— 175° F71°— 79° C DUCK 160°— 175° F71°— 79° C TURKEY 160°— 175° F71°— 79° C GENERAL 160°— 175° F71°— 79° C
FISH/SEAFOOD
FISH Baked/Fried 160°— 175° F71°— 79° C LOBSTER 160°— 175°F71°— 79° C SHRIMP Fried 160°— 175°F71°— 79° C
BAKED GOODS
BREADS/ROLLS 120°— 140° F49°— 60° C
MISCELLANEOUS
CASSEROLES 160°— 175° F71°— 79° C DOUGH Proofing 80°— 100° F27°— 38° C EGGS Fried 150°— 160° F66°— 71° C FROZEN ENTREES 160°— 175° F71°— 79° C HORS D'OEUVRES 160°— 180°F71°— 82° C PASTA 160°— 180°F71°— 82° C PIZZA 160°— 180°F71°— 82° C POTATOES 180°F82°C PLATED MEALS 180°F82° C SAUCES 140°— 200°F60°— 93° C SOUP 140°— 200° F60°— 93°C VEGETABLES 160°— 175° F71°— 79°C
The holding temperatures listed are suggested guidelines only.
INTERNAL FOOD PRODUCT TEMPERATURES
HOT FOODS
DANGER ZONE 40° TO 140°F(4° TO 60° C)
CRITICAL ZONE 70° TO 120°F (21° TO 49°C)
SAFE ZONE 140° TO 165° F (60° TO 74° C)
COLD FOODS
DANGER ZONE ABOVE 40°F (ABOVE 4°C)
SAFE ZONE 36°F TO 40° F(2°C TO 4° C)
FROZEN FOODS
DANGER ZONE ABOVE 32°F (ABOVE 0°C)
CRITICAL ZONE 0° TO 32° F (-18° TO 0° C)
SAFE ZONE 0° F OR BELOW (-18°C OR BELOW)
SANITATION GUIDELINES GENERAL HOLDING GUIDELINES
#855 Operation & Care Manual • 6
SAFETY ALERT
This units performance has been
optimized using the factory provided
bulbs. These bulbs should be
replaced with an exact
replacement or with a factory recommended replacement. These bulbs have been treated to resist breakage and must be replaced with similarly treated bulbs in order to maintain compliance with NSF standards.
Disconnect the unit from the power
source before cleaning or servicing.
TY-72/PL; TY-72/PR
TYSYS-72/PL; TYSYS-72/PR
TY-72; TY-72/P
TYSYS-72; TYSYS-72/P
Power Configurations
Bulbs
100 Watt, 130V, STANDARD . . . . . . . . . . . . . . . LP-33592
100 Watt, 130V, BLUE TINT . . . . . . . . . . . . . . . LP-33253
100 Watt, 230-250V,
STANDARD . . . . . . . . . . . . LP-3384
Carving Station, Single Well . . . . . . . . . . . . . . . . . . . 55299
Gauge, Interior Ambient Temperature . . . . . . . . . GU-33384
Glass Panes, End, Reflective, Tempered
RIGHT-HAND . . . . . . . . . . . . . . . . . . . . . . . . . . GL-22539
LEFT-HAND . . . . . . . . . . . . . . . . . . . . . . . . . . GL-22538
Glass, Tempered, End Spacer . . . . . . . . . . . . . . . GL-22719
Glass, Tempered, 2' Full Curved: TY-72/PL & /PR . . GL-23746 Independent Circuit Cordset Pkg.* TY, 120/208-240 ONLY . 14221 Independent Load Center Pkg.* TYSYS,120/208-240 ONLY . 14220
*NOT CSA APPROVED
Pan, Self Service, 4 deep . . . . . . . . . . . . . . . . . . . . 16358
Pan Separator Bar
Sheet Pan (long bar) . . . . . . . . . . . . . . . . . . . . . . 11046
One-Third Size Pan . . . . . . . . . . . . . . . . . . . . . . . 11047
Full-Size (long) . . . . . . . . . . . . . . . . . . . . . . . . . . 11317
Half-Size/Third Size . . . . . . . . . . . . . . . . . . . . . . 11318
Sheet Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11319
Sheet Pan (short bar) . . . . . . . . . . . . . . . . . . . . . . 11320
Gastronorm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1865
Half-Size Sheet Pan. . . . . . . . . . . . . . . . . . . . . . . 11805
Panel, Front Custom Colors . . . . . . . . . . . . . . . . . . . . P120
Panels, End Black Patch,
TYSYS ONLY . . . . . . . . . . . . . . . . . PE-22708
Solid Black Patch, right-hand, TYSYS ONLY . . . . . PE-23674
Solid Black Patch, left-hand, TYSYS ONLY . . . . . . PE-23675
Panels, End, Stainless Steel, KIOSK ASSEMBLY, TY ONLY . 14600
Panel, Stainless Steel Front . . . . . . . . . . . . . . . . . . . 12645
Product Probe Package: TY-72 & 72/P 120/208-240 ONLY . . 5296 Product Probe Package: TY-72/PL & PR 120/208-240 ONLY . 5295
Scale Platform Package 120/208-240 ONLY . . . . . . . . . . . 14102
Multiple Timer Bar Package w/probe outlet. . FACTORY INSTALLED
TY, TYSYS-72/PL, 4' . . . . . . . . . . . . . . . . . . . . . 55196
TY, TYSYS-72/PR, 4' . . . . . . . . . . . . . . . . . . . . . 55198
TY, TYSYS-72(P) . . . . . . . . . . . . . . . . . . . . . . . . 55200
Cable Heating Service Kit (full service). . . . . . . . No. 4881
includes:
CB-3045 . .Cable Heating Element. . . . . . . . . . . . . . . . . 210 feet
CR-3226 . .Ring Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
IN-3488 . .Insulation Corner . . . . . . . . . . . . . . . . . . . . . . . 1 foot
BU-3105 . .Shoulder Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . 6
BU-3106 . .Cup Bushing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SL-3063 . .Insulating Sleeve. . . . . . . . . . . . . . . . . . . . . . . . . . . 6
TA-3540 . .High Temperature Tape . . . . . . . . . . . . . . . . . . 1 roll
TY-72 Series • Options and Accessories
Cable Heating Service Kit (full service) . . . . . . . . No. 4880
includes:
CB-3045 . . Cable Heating Element . . . . . . . . . . . . . . . . 134 feet
CR-3226 . . Ring Connector . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IN-3488 . . . Insulation Corner . . . . . . . . . . . . . . . . . . . . . . 1 foot
BU-3105 . . Shoulder Bushing . . . . . . . . . . . . . . . . . . . . . . . . . 4
BU-3106 . . Cup Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SL-3063 . . . Insulating Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TA-3540 . . High Temperature Tape. . . . . . . . . . . . . . . . . . 1 roll
Cable Heating Service Kit (self-service) . . . . . . . No. 4878
includes:
CB-3045 . . Cable Heating Element . . . . . . . . . . . . . . . . . 72 feet
CR-3226 . . Ring Connector . . . . . . . . . . . . . . . . . . . . . . . . . . 4
IN-3488 . . . Insulation Corner . . . . . . . . . . . . . . . . . . . . . . 1 foot
BU-3105 . . Shoulder Bushing . . . . . . . . . . . . . . . . . . . . . . . . . 4
BU-3106 . . Cup Bushing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SL-3063 . . . Insulating Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . 4
TA-3540 . . High Temperature Tape. . . . . . . . . . . . . . . . . . 1 roll
LIGHTS
HEATING
CABLE
LIGHTS
HEATING
CABLE
600
WATTS
1300
WATTS
TYSYS-72 TYSYS-72/P TOTAL: 5400 Watts (maximum)
600
WATTS
SELF
SERVICE
PAN
1300
WATTS
TYSYS-72/PL TYSYS-72/PR TOTAL: 5400 Watts (maximum)
300
WATTS
1300
WATTS
300
WATTS
1300
WATTS
600
WATTS
1300
WATTS
600
WATTS
1300
WATTS
#855 Operation & Care Manual • 7
TY-72
1/15/01
PART DESCRIPTION QTY A/S PT NO.
1. BOTTOM END PANEL, 120/240V 1 13028 BOTTOM END PANEL, 230V 1 13986 BOTTOM RIGHT-HAND PANEL, 4' (1219mm) 1 13029 BOTTOM LEFT-HAND PANEL, 4' (1219mm) 1 13030 BOTTOM PANEL, 6' (1829mm) 1 13031
2. BOTTOM MOUNTING SCREWS 25 SC-2425 BOTTOM MOUNTING SCREWS 2 SC-2459
3. CORD: 6 (1829mm), 120/240V 1 CD-3557 CORD, 230V 1 CD-33489
4. PLUG, 120/240V 1 PG-3267
5. CONTROL PANEL MOUNTING SCREWS 5 SC-2459
6. INSULATION: 25.5 x 120 (648mm x 3048mm) 1 IN-22364
7. CABLE CONNECTION HARDWARE
8. HEATING CABLE: 205 (62484mm) 1 CB-3045
9. THERMOSTAT 3 TT-3498 THERMOSTAT KNOB 3 KN-3473
10. INDICATOR LIGHT 3 LI-3025 INDICATOR LIGHT 3 LI-3951
11. BULB SWITCH 3 SW-3616
12. FUSEHOLDER (120V UNITS)
INCLUDES 1 FU-33041
FUSE, 15 AMP 1 FU-3775 FUSEHOLDER MOUNTING SCREWS 2 SC-2077
13. TOP 1 4394 TOP MOUNTING SCREWS 5 SC-2425 TOP MOUNTING SCREWS 5 SC-2459
14. BULBS, 120/240V 10 LP-33592 BULBS, 230V 10 LP-3384
15. BULB SOCKETS, 120/240V 10 RP-3952 BULB SOCKETS, 230V 10 RP-3955
16. DOOR ASSEMBLY LEFT-HAND GLASS DOOR - IN 1 DR-22481A RIGHT-HAND GLASS DOOR - IN 1 DR-22481B CENTER GLASS-OUT 2 DR-22481E GUIDES #44049 16 DR-22480F DOOR BUMPER ASSEMBLY 2 DR-22480G TOP TRACK 1 TK-23749 BOTTOM TRACK 1 TK-24266
17. END PANEL 2 PE-22585
18. CUTTING BOARD ASSEMBLY 1 4017
19. CUTTING BOARD BRACKET (BASE) 2 12069 CUTTING BOARD BRACKET MTG. SCREWS 6 SC-24520
20. CUTTING BOARD BRACKET 2 BT-2342
23. END GLASS 2 GL-22479 END GLASS GASKET: 5 (1524mm) 1 GS-22547
24. FRONT GLASS 1 GL-22478
25. PAN DIVIDER BARS,
NOT SHOWN
FULL/HALF/THIRD (LONG BAR) 4 11317 FULL/HALF/THIRD (SHORT BAR) 15 11318 SHEET PAN 3 11320 5-PAN DIVIDER (LONG) 2 11357
26. ADJUSTABLE LEGS 4 LG-22686
27. TERMINAL BLOCK, 4 POS 2 BK-3597
28. SNAP-IN RECEPTACLES 2 RP-3396 RECEPTACLE FUSE, 15 AMP 1 FU-33351 RECEPTACLE FUSEHOLDER, 15 AMP 1 FU-33352
29. OUTLET HOUSING COVER 1 4980
30. 6 PROBE PACKAGE OPTION,
NOT SHOWN 1 5296
31. FRONT GLASS STRUTS 2 SU-2870
32. IND. CIRCUIT CORDSET PKG. OPTION, 120V* 1 14221
*NOT CSA APPROVED
TYSYS-72
1/15/01
PART DESCRIPTION QTY A/S PT NO.
1. BOTTOM END PANEL 1 13028 BOTTOM RIGHT-HAND PANEL, 4' (1219mm) 1 13029 BOTTOM LEFT-HAND PANEL, 4' (1219mm) 1 13030 BOTTOM PANEL, 6' (1829mm) 1 13031
2. BOTTOM MOUNTING SCREWS 25 SC-2425 BOTTOM MOUNTING SCREWS 2 SC-2459
3. CONTROL PANEL MOUNTING SCREWS 5 SC-2459
4. CONDUIT TUBING: .7 (213mm) 1 TU-3874
5. INSULATION: 25.5 x 120 (648mm x 3048mm) 2 IN-22364
6. CABLE CONNECTION HARDWARE:
7. HEATING CABLE: 205 (62484mm) 1 CB-3045
8. THERMOSTAT 3 TT-3498 THERMOSTAT KNOB 3 KN-3473
9. INDICATOR LIGHT 3 LI-3025 INDICATOR LIGHT 3 LI-3951
10. BULB SWITCH 3 SW-3616
11. TOP 1 4394 TOP MOUNTING SCREWS 5 SC-2425 TOP MOUNTING SCREWS 5 SC-2459
12. BULBS, 120/240V 10 LP-33592 BULBS, 230V 10 LP-3384
13. BULB SOCKET, 120/240V 10 RP-3952 BULB SOCKET, 230V 10 RP-3955
14. CIRCUIT BOX (120V),
INCLUDES 1 CI-3906
BREAKER, 20 AMP 2 CI-3907 BREAKER, 15 AMP 1 CI-33071 GROUND BAR KIT 1 CI-3878
CIRCUIT BOX (230V),
INCLUDES 1 CI-3906
BREAKER, 20 AMP 2 CI-3907 BREAKER, 15 AMP 2 CI-33071 GROUND BAR KIT 1 CI-3878
15. DOOR ASSEMBLY LEFT-HAND GLASS DOOR - IN 1 DR-22481A RIGHT-HAND GLASS DOOR - IN 1 DR-22481B CENTER GLASS-OUT 2 DR-22481E GUIDES #44049 16 DR-22480F DOOR BUMPER ASSEMBLY 2 DR-22480G TOP TRACK 1 TK-23749 BOTTOM TRACK 1 TK-24266
16. END PANEL 2 PE-22493
17. CUTTING BOARD ASSEMBLY 1 4017
18. CUTTING BOARD BRACKET (BASE) 2 12069 CUTTING BOARD BRACKET MTG. SCREWS 6 SC-24520
19. CUTTING BOARD BRACKET 2 BT-2342
22. END GLASS 2 GL-22479 END GLASS GASKET: 5 (1524mm) 1 GS-22547
23. FRONT GLASS 1 GL-22478
24. BASE BOTTOM 1 1375
25. PAN DIVIDER BARS,
NOT SHOWN
FULL/HALF/THIRD (LONG BAR) 4 11317 FULL/HALF/THIRD (SHORT BAR) 15 11318 SHEET PAN 3 11320 5-PAN DIVIDER (LONG) 2 11357
26. SNAP-IN RECEPTACLES 2 RP-3396
27. OUTLET HOUSING COVER 1 4980
28. RECEPTACLE FUSE, 15 AMP 1 FU-33351 RECEPTACLE FUSEHOLDER, 15 AMP 1 FU-33352
29. FRONT GLASS STRUTS 2 SU-2870
30. 6 PROBE PACKAGE OPTION,
NOT SHOWN 1 5296
31. LOAD CENTER PKG. OPTION (120V),
NOT SHOWN 1 14220
#855 Operation & Care Manual • 8
Loading...
+ 20 hidden pages