Allied Telesis AT-RH509BE User Manual

Electrical Safety
BNC
7X8X
6X 5X
3X
4X
2X 1X
5V 1.2A
BNC
7X8X
6X 5X
3X4X
2X 1X
5V 1.2A
BNC
7X
8X
6X
5X
3X
4X
2X 1X
5V 1.2A
IMPORTANT: This equipment must be installed in accordance with safety precautions. To see any safety information in this guide in multiple languages, refer to the “Translated Safety Information Booklet” at the page number indicated by the icon.
Elektrische Sicherheit WICHTIG: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvorkehrungen
erforderlich. Wenn Sie eine der Sicherheitsinformationen dieser Anleitung in mehrsprachiger Übersetzung lesen möchten, finden Sie diese in der Broschüre "Übersetzte Sicherheitsinformationen" unter der Seitennummer, auf die mit dem Symbol verwiesen wird. (German)
Elektrisk sikkerhed VIGTIGT: Dette udstyr skal installeres i overensstemmelse med sikkerhedsadvarslerne.
Sikkerhedsvejledningen i denne flersprogede håndbog kan findes i afsnittet "Oversatte sikkerhedsinformationer" på det sidenummer, der er angivet ved symbolet. (Danish)
Elektrische veiligheid BELANGRIJK: Dit apparaat moet in overeenstemming met de veiligheidsvoorschriften worden
geïnstalleerd. Om veiligheidsinformatie in deze gids in meerdere talen te zien, refereren aan de kop "Vertaalde veiligheidsinformatie" op de door het symbool aangegeven pagina. (Dutch)
Sécurité électrique IMPORTANT: Cet équipement doit être utilisé conformément aux instructions de sécurité. Pour
consulter les avertissements en diverses langues dans ce guide, reportez-vous à la section «þTraductions des avertissements de sécuritéþ», qui figure à la page signalée par l'icône . (French)
Sähköturvallisuus TÄRKEÄÄ: Tämä laite on asennettava turvaohjeiden mukaisesti. Pour consulter les
avertissements en diverses langues dans ce guide, reportez-vous à la section «þTraductions des avertissements de sécuritéþ», qui figure à la page signalée par l'icône . (Finnish)
Sicurezza elettrica IMPORTANTE: questa apparecchiatura deve essere installata rispettando le norme di sicurezza.
Per le informazioni sulla sicurezza in più lingue contenute in questa guida, consultare la sezione "Informazioni di sicurezza tradotte" alla pagina indicata dall'icona . (Italian)
Elektrisk sikkerhet VIKTIG: Dette utstyret skal installeres i samsvar med sikkerhetsregler.Du kan se all
sikkerhetsinformasjonen i denne veiledningen på flere språk ved å slå opp på overskriften "Oversatt sikkerhetsinformasjon" på sidetallet angitt av symbolet . (Norwegian)
Segurança Eléctrica IMPORTANTE: Este equipamento tem que ser instalado segundo as medidas de precaução de
segurança. Para ver qualquer informação sobre segurança neste guia, em vários idiomas, consultar a secção entitulada “Informação de Segurança Traduzida”, no número de página indicado pelo ícone . (Portuguese)
Seguridad eléctrica IMPORTANTE: La instalación de este equipo deberá llevarse a cabo cumpliendo con las
precauciones de seguridad. Para ver cualquier información de seguridad en esta guía en múltiples idiomas, consulte el encabezamiento de la “Información de seguridad traducida” en la página cuyo número indica el icono . (Spanish)
Elsäkerhet OBS! Alla nödvändiga försiktighetsåtgärder måste vidtas när denna utrustning används. . För
flerspråkiga säkerhetsvarningar i denna handledning hänvisas du till den sida som följer efter ikonen under rubriken "Översatta säkerhetsvarningar." (Swedish)
RADIATED ENERGY U.S. Federal Communications Commission
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital equipment meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Warning
In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures page 5.
Warning
This product requires shielded cables to comply with Class A emission limits. If not used with shielded cables, this product may cause radio interference in which case the user may be required to take adequate measures page 6.
European Community (EC) Electromagnetic Compatibility Directive
This equipment has been tested and found to comply with the requirements of European Emissions Standard EN55022 Class A and the Generic European Immunity Standard EN50082-1 that requires compliance to the following standards:
ELECTRICAL SAFETY TUV EN60950, UL1950, CSA950
a) IEC 801-2 Electrostatic discharge b) IEC 801-3 RF Immunity c) IEC 801-4 Transient burst
AT-RH500 Series Hubs LEDs
Table 2
LED Color State Description
10BASE-T/BNC
NETWORK PORTS
LINK
RCV
1 2 3 4 BNC COL PWR
EUROPE - EU
Electrical Safety TUV-EN60950 Use only a Power Supply that has been Licensed by a EU Notified Body (For example:
TUV,BSI,VDE ) for use in the country of end use, with a output rated DC 5V, minimum 1.2 A.”
USA/CANADA
Electrical Safety UL 1950, CSA 950 Use only a UL Listed/CSA Certified AC Power Supply with an output rated DC 5V, minimum 1.2 A.” Utiliser seulement une alimentation c.a. homologuée UL/CSA, avec un courant nominal de sortie de 5 V c.c., minimum 1,2 A.”
HUB
STATUS
IEEE 802.3/ ETHERNET 10BASE-T/BNC PORT MICRO HUB/ REPEATER
Verifying Package Contents
Make sure that you have received the following items:
AT-RH505BE or AT-RH509BE hub (dependent upon purchase)
AC power supply (specific for U.S., U.K., and Continental Europe)
This quick install guide
Translated safety information booklet
Warr a nty c ard
Self-adhesive rubber feet (4)
Vel cr o ki t ( 2 pa ds )
AT-RH505BE and AT-RH509BE Hub Overview
The AT-RH505BE and AT-RH509BE five (10 Mbps)and nine-port hubs are 10Base-T desktop Ethernet hubs that include:
Four/eight 10Base-T ports (RJ45)
One BNC interface for 10Base2 backbone support and stacking
Easy to read LEDs for port and hub status
DC power connector
Both hubs are specifically designed for small office environments. Their Velcro mounting kit makes it convenient for positioning on a file cabinet, desk-side, a wall, or other locations.
AT-RH505BE and AT-RH509BE Micro Hub Models
Table 1
BNC 3X4X 2X 1X
BNC Port - Connect a thin coax segment to this port
RJ45 Ports (1-4) - Connect workstations or other devices that use twisted pair cabling
Power - Use adapter shipped with hub
5V 1.2A
Desktop and Wall Installation
To install a single AT-RH500 Series hub either with the Velcro kit or on the desktop, do the following:
1. For wall installation, place two Velcro pads on the bottom of the unit, then place the other pads on a wall. Align the unit’s Velcro pads with the two pads on the wall to attach the unit to the wall. For desktop installation, attach the four rubber feet to the bottom of the unit. Then place the hub on a secure desktop.
Caution
Air vents must not be blocked and must have free access to the room ambient air for cooling page 13.
2. Plug the power supply into a wall socket and connect the DC cable to the unit. Check the LEDs to ensure that the PWR LED lights. See Table 1.
3. Connect the twisted pair cables to the hub’s RJ45 ports. Connect the other ends of the twisted pair cables to the computer’s network adapter card.
LINK/RCV (Ports)
BNC (Ports) Green ON
COL (Hub) Yellow Flashing
PWR (Hub) Green ON
Applications
The BNC interface provides for the following hub configurations:
Stacking Hubs Using the BNC Port
1. Connect a BNC-T connector to the BNC port on the hub.
2. If the hub is at the terminal end of a trunk segment, connect a BNC
3. Connect coaxial cable to an open end on the T connector attached to
4. Connect the other end of the coaxial cable to the BNC port on the
Green ON
Flashing
OFF
Flashing
OFF
OFF
indicates that the link test pulse is
ON
receiving properly.
indicates that a packet is being
Flashing
received on the specified port.
indicates that a connection defect is
OFF
occurring such as UTP cable.
indicates that power is being supplied to
ON
the BNC drivers (Port 5 and Port 9).
indicates that a packet is received on
Flashing
Port 5 or port 9.
indicates that no power is being supplied
OFF
to the BNC connector.
indicates that a collision is occurring
Flashing
on the network.
indicates that the unit is receiving power.
ON
indicates that the unit is not receiving
OFF
power.
In a bus topology for connecting up to 30 hubs In a stacked configuration for network expansion As a backbone connection to legacy LANs
NOTE: When attaching the hub to a router or other device, verify the port type used on these devices prior to attaching any cables.
terminator to the open end of the T connector.
the BNC port on the hub.
next device in the segment.
Models Description
AT-RH505BE Four 10Base-T (shielded RJ45) and one 10Base2 (BNC) port
AT-RH509BE Eight 10Base-T (shielded RJ45) and one 10Base2 (BNC) port
Functional Description
The AT-RH500 Series hubs performs the following functions:
Preamble regeneration
Fragment extension
MAU jabber lockup protection
Auto partitioning/reconnection
Twisted pair cable reverse polarity detection and automatic correction
Figure 1
NOTE: Cable length must not exceed 100 m (328 ft).
BNC
8X
7X
6X
5X
Standalone Hub Installation
4X
3X
2X
1X
5V 1.2A
Figure 2
BNC Connection for Stacking Hubs
NOTE: The minimum distance between BNC connections on the segment is 0.5 m (1.64 ft). Maximum cable segment is 185 m (607 ft) with a maximum of 30 nodes.
2 3 45
Tro u b le s h o ot i ng
1. Verify power for the hub and all attached devices by checking the PWR LED on the hub to make sure it lights green.
2. Make sure that all devices are securely attached to the network and that the adapter card(s) are operating.
3. Follow the recommended cable distances and repeater limitations.
4. A specific port may have been partitioned from the network. Check for a defective network adapter or cable connection and make sure that all devices are connected to the network by a single path.
5. If thin coaxial cable is used, make sure that the cable run is termi­nated at both ends using a BNC terminator. If no cables or termi­nators are connected to the BNC port, ignore the status LED for this port.
Technical Specifications
Table 3
Physical
Dimensions W x D x H
Weight 180 g (AT-RH505BE)
Operating temperature
Storage temperature
Operating altitude up to 10,000 ft
Humidity limits 5% to 80% (non-condensing)
Power Consumption 4 W (AT-RH505BE)
Input Voltage 5.0 VDC
Input Current 1.2 A
Network IEEE 802.3 10Base-T and 10Base2
Safety UL1950, CSA22.2 No. 950, TUV (EN60950, EN41003)
EMI Emissions FCC Class A, VCCI Class A, EN55022 Class A
EN50082-1 (ESD immunity IEC 801-2 1984 Level 2, RF immunity IEC-801-3 1984 Level 2, and EFT/Burst Immunity IEC 801-4 1988 Level 2)
CE Compliant
MTBF
99 mm x 54 mm x 21 mm (AT-RH505BE) 158 mm x 54 mm x 21 mm (AT-RH509BE)
270 g (AT-RH509BE)
Environmental
0
0
C to 40 0C
0
-20
C to 80 0C
Electrical
6 W (AT-RH509BE)
Standards
EMI Immunity
Reliability
153,000 hrs at 25 102,000 hrs at 25
o
C or above (AT-RH505BE)
o
C or above (AT-RH509BE)
Where To Find Allied Telesyn
Location Phone/Fax
Americas
U.S.A., Canada, Mexico, Central America, South America
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India
Australia
Australia, New Zealand
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa
Germany
Germany, Switzerland, Austria, Eastern Europe
Hong Kong
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel
Japan
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland, Iceland
Technical Bulletin Board
Technical Support E-mail Address
CompuServe
Internet, World Wide Web and FTP site
6 7
1 (800) 428-4835 1 (918) 628-3222
(+65) 383-3832 (+65) 383-3830
(+61) 2-943-5111 (+61) 2-943-4966
(+33) 1-60-92-15-32 (+33) 1-69-28-37-49
(+49) 30-435-90-00 (+49) 30-435-706-50
(+852) 2-529-4111 (+852) 2-529-7661
(+39) 02-416047 (+39) 02-419282
(+81) 3-3443-5640 (+81) 3-3443-2443
(+44) 1-235-442500 (+44) 1-235-442590
1-425-483-7979
TS1@alliedtelesyn.com
Go ALLIED
http://www.alliedtelesyn.com
Copyright 1998, 1999 Allied Telesyn International, Corp 960 Stewart Drive Suite B, Sunnyvale CA 94086 USA
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International, Corp.
Centr e
COM is a registered trademark of Allied Telesyn International, Corp
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesyn International, Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International, Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International, Corp. has been advised of, known, or should have known, the possibility of such damages.
PN 613-10705-00 Rev. C
8
Micro Hubs
AT-RH505BE AT-RH509BE
!
Quick Install Guide
Loading...