Allied Telesis AT-PWR3004 User Manual

Note
Note
AT-RPS3004 Redundent Power Supply Unit &
AT-PWR3004 Power Module
Installation Guide
Overview
The AT-RPS3004 can supply redundant power for up to four Ethernet switches. It provides external power to the switch should the primary (internal) power supply unit fail. Initially, it contains one pre-installed AT-PWR3004 power module. Each AT-PWR3004 power module can support one switch.
You can purchase additional power modules from your Allied Telesis representative. If you purchased more AT-PWR3004 Power Modules, they must be installed in the AT-RPS3004 Redundent Power Supply Unit. The power modules cannot be used as standalone units.
AT-8016F/MTAT-8016F/SCAT-8024M AT-8516F/SCAT-8524MAT-8550/SPAT-8624T/2MAT-8648T/2SP
The AT-RPS3004 can be installed on a desktop or in a standard 19-inch equipment rack.
It is not necessary to power OFF the AT-RPS3004 unit or the connected Ethernet switches to install a new AT-PWR3004 power module.
E1
E2
E3
E4
E5
E6
E7
E8
E21
Warning: To prevent electric shock, do not remove the cover.
No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of electric shock, disconnect electric power to the product before connecting or disconnecting the LAN cables.
Warning: Do not work on equipment or cables during periods of lightning activity.
Warning: Power cord is used as a disconnection device. To de­energize equipment, disconnect the power cord.
Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible.
Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling.
Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° degrees C.
All Countries: Install product in accordance with local and National Electrical Codes.
Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Related Documents
The Allied Telesis web site offers you an easy way to access the most recent documentation, software, and technical information for all of our products. For details on the features and functions of your Allied Telesis Fast Ethernet Switch, go to www.alliedtelesis.com.
Package Contents for the AT-RPS3004 Power Supply Unit
Make sure the following items are included in the shipping package..
AT-RPS3004 Power Supply Unit (chassis) with pre-installed AT-PWR3004 Power Mod-
ule
Two Rack Mounting Brackets with six mounting screws
One AC power cord and one DC power cord
Installation Guide amd Warramty Card
Package Contents for an AT-PWR3004 Power Module
If you have purchased the AT-PWR3004 power module, make sure the following items are included in the shipping package.
One AT-PWR3004 Power Module
One DC power cord
Installation Guide amd Warramty Card
Installing an AT-RPS3004 Power Supply Unit
The redundant power supply should be installed close to the switches so that you can easily connect the RPS DC cables to the unit. It is recommended that you install the redundant power supply directly above or below your Ethernet switch.
Perform the following procedure to install the power supply in a standard 19-inch rack. If you are not installing the power supply in a rack, go to step 7:
1. Place the unit upside down on a level, secure surface.
2. Using a flat-head screwdriver, remove the snap-on plastic feet from the bottom of the power supply, as displayed below.
E25
Warning: Mounting of the equipment in the rack should be
such that a hazardous condition is not created due to uneven mechanical loading.
E35
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Safety Statement
Please review the following safety statements before you begin this installation. A translation of these safety statements is available in PDF format titled “Translated Safety Statements” and may be found at www.alliedtelesis.com.
E36
E37
Caution: Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
Warning: Reliable earthing of rack-mounted equipment should
3. Turn the power supply right side up.
be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips).
PN 613-50342-00 Rev B 1 3
4. Attach the two rackmounting brackets to each side of the power supply chassis
Note
AT-PWR3004
ON/OFF
Switch
DC Connector
AC Power Connector
Note
Note
Installation
Handle
Installation Screw
Screw
using the six screws that came with the RPS chassis, as displayed below.
10. Turn on the AT-RPS3004 unit using the switch on the back panel of the unit.
11. Make sure the LED on the front of the power supply is solid green.
12. Make sure the RPS LED on the front of the Ethernet switch is green. This indicates a good connection to the AT-RPS3004 unit.
Technical Specifications
Dimensions:
AT-RPS3004 Unit: 44 cm x 35.56 cm x 6.6 cm
(17.32 in x 14 in x 2.6 in)
AT-PWR3004 Power Module: 30.48 cm x 10.8 cm x 6.35 cm
(12 in x 4.25 in x 2.5 in)
5. Mount the power supply in the 19-inch rack using standard screws (not provided).
6. Attach the provided DC power cord to the DC connector on the back panel of the AT-RPS3004 power supply.
7. Connect the other end of the DC power cord to the RPS Input connector on the back panel of the Ethernet switch.
Installing an Additional AT-PWR3004 Power Supply Module
The AT-PWR3004 power module must be installed in an AT-RPS3004 chassis. It cannot be used as a standalone unit.
It is not necessary to power OFF the AT-RPS3004 unit or the connected Ethernet switches to install a new AT-PWR3004 power module.
To install an additional AT-PWR3004 power module, perform the following steps:
1. Remove the AT-PWR3004 power module from the shipping package and store the packing material in a safe place.
2. Remove a blank faceplate from an empty expansion slot from the front of the AT­RPS3004 unit by unscrewing the two installation screws with a Phillips screwdriver.
3. Before installing the new AT-PWR-3004 power module, identify the DC power connector on the back panel of the AT-RPS3004 unit directly behind the power module slot where the new power module will be installed and attach one end of the provided DC power cord to this DC connector.
4. Attach the other end of the DC power cord to the RPS Input connector on the back panel of the Ethernet switch.
5. Place one hand under the AT-PWR3004 power module to support it and place the other hand on the handle. Slide the new AT-PWR3004 power module into the chassis, as displayed below, to guide the module into the unit.
Weight:
AT-RPS3004 Fully Loaded: 9.46 kg (20.85 lb) AT-PWR3004 Power Module: 1.06 kg (2.35 lb)
Input Voltage: 100 to 264 VAC
Input Frequency Range: 50 to 60 Hz
Maximum Operating Temperature: -20° C to 40° C (-4° F to 104° F)
Maximum Storage Temperature: -40° C to 70° C (-40° F to 158° F)
Operating and Storage Altitude: Up to 3,048 meters (10,000 ft)
Humidity: 8% to 95% (non-condensing)
EMC: FCC Class A,
EN55022 Class A, EN55024
Safety: EN60825, EN60950 (TUV),
UL1950 (UL/cUL)
Electrical Safety and Emission Statement
Standards: This product meets the following standards.
U.S. Federal Communications Commission
RADIATED ENERGY Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emission FCC Class A, EN55022 Class A, VCCI Class A
WARNING: In a domestic environment this product may cause radio interference in which case the user may
be required to take adequate measures.
8. Plug the AC power cord for the AT-RPS3004 into the AC connector on the back panel of the unit.
The AT-RPS3004 unit and Ethernet switches should be connected to power outlets on separate circuits. This will protect the switches from a loss of power should the switch circuit breaker trip.
9. Plug the other end of the AC power cord into a wall outlet.
Immunity EN55024
Electrical Safety UL1950 (UL/cUL), EN60950 (TUV)
6. Once firmly installed, use a Phillips screwdriver to tighten the installation screws on the module to secure it to the chassis.
7. Make sure the LED on the front of the AT-PWR3004 power module is green.
8. Make sure the RPS LED on the front of the Ethernet switch is green. This indicates a good connection to the AT-PWR3004 power module.
Copyright © 2009 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
4 5 6
Loading...