Allied Telesis AT-PWR1200, AT-RPS3000, AT-PWR800, AT-PWR250 User Manual

Page 1
AT-RPS3000
Redundant Power Supply
AT-RPS3000
AT-PWR250
AT-PWR800
AT-PWR1200
Installation Guide
2179
613-001498 Rev. B
Page 2
All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc.
Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners.
Allied Telesis, Inc. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesis, Inc. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesis, Inc. has been advised of, known, or should have known, the possibility of such damages.
Page 3
Electrical Safety and Emissions Standards
This product meets the following standards.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI
Class A, C-TICK, CE
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
EMC (Immunity) EN55024
Electrical Safety EN60950-1 (TUV), UL 60950-1 (
CULUS
)
Laser Safety EN60825
3
Page 4
Translated Safety Statements
Important: The indicates that translations of the safety statement are available in the PDF document “Translated Safety Statements” posted on the Allied Telesis website at www.alliedtelesis.com.
4
Page 5

Contents

Preface ............................................................................................................................................................ 11
Document Conventions .................................................................................................................................... 12
Where to Find Web-based Guides ................................................................................................................... 13
Contacting Allied Telesis .................................................................................................................................. 14
Online Support ........................................................................................................................................... 14
Email and Telephone Support.................................................................................................................... 14
Warranty..................................................................................................................................................... 14
Returning Products .................................................................................................................................... 14
Sales or Corporate Information .................................................................................................................. 14
Management Software Updates................................................................................................................. 14
Chapter 1: Overview ...................................................................................................................................... 15
Features ........................................................................................................................................................... 16
LED Panel .................................................................................................................................................. 16
Power Supply Slots .................................................................................................................................... 17
RPS Connectors ........................................................................................................................................ 17
Power Supply Modules..................................................................................................................................... 19
System Power and Power for PoE+ ................................................................................................................. 21
System Power ............................................................................................................................................ 21
PoE+ Power ............................................................................................................................................... 22
Low-power and High-power Switches .............................................................................................................. 24
Configuration Examples ................................................................................................................................... 25
Low-power Switches .................................................................................................................................. 25
High-power Switches ................................................................................................................................. 28
PoE+ Switches........................................................................................................................................... 30
Invalid Configurations................................................................................................................................. 33
Choosing a Power Supply Module ................................................................................................................... 36
Non-PoE+ Switches ................................................................................................................................... 36
PoE+ Switches........................................................................................................................................... 37
Power Module Combinations for PoE+ Switches....................................................................................... 40
................................................................................................................................................................... 41
LEDs................................................................................................................................................................. 42
Module A/B Ports LEDs ............................................................................................................................. 42
Power Module Status LEDs ....................................................................................................................... 44
Power Module LED .................................................................................................................................... 46
On/Off Power Switches .................................................................................................................................... 47
Guidelines......................................................................................................................................................... 48
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules ........................................... 49
Reviewing Safety Precautions.......................................................................................................................... 50
Planning the Installation ................................................................................................................................... 52
Unpacking the AT-RPS3000 Chassis and Power Supply Modules .................................................................. 54
AT-RPS3000 Chassis ................................................................................................................................ 54
Power Supply Modules .............................................................................................................................. 55
Selecting a Location for the AT-RPS3000 Chassis in the Equipment Rack ..................................................... 57
5
Page 6
Contents
Installing the AT-RPS3000 Chassis in an Equipment Rack.............................................................................. 58
Installing a Power Supply Module..................................................................................................................... 61
Connecting the AT-RPS3000 Chassis to the x610 Series Switch ....................................................................65
Powering On the Power Supply Modules ......................................................................................................... 69
Chapter 3: Removing Power Supply Modules ............................................................................................. 75
Removing the AT-RPS-CBL1.0 Cable ..............................................................................................................76
Removing an AC Power Supply Module ........................................................................................................... 78
Chapter 4: Troubleshooting .......................................................................................................................... 83
Appendix A: Technical Specifications ......................................................................................................... 87
Physical Specifications .....................................................................................................................................87
Environmental Specifications ............................................................................................................................ 87
Power Specifications.........................................................................................................................................88
Certifications .....................................................................................................................................................88
Port Pin-outs ..................................................................................................................................................... 89
6
Page 7

Figures

Figure 1: LED Panel .............................................................................................................................................................16
Figure 2: Slots A and B for the Power Supply Modules........................................................................................................17
Figure 3: Slot A and RPS 1 and 2 Ports...............................................................................................................................17
Figure 4: Slot B and RPS 3 and 4 Ports...............................................................................................................................18
Figure 5: RPS Ports..............................................................................................................................................................18
Figure 6: Removable and Non-removable Power Supply Modules in x610 Switches ..........................................................22
Figure 7: Example of a Single Low-power Switch Connected to an RPS System Port ........................................................25
Figure 8: Example of a Non-PoE+, Low-power Switch Connected to an RPS PoE+/System Port ......................................26
Figure 9: Example of Two Low-power Switches...................................................................................................................26
Figure 10: Example of Four Low-power Switches ................................................................................................................27
Figure 11: Example of Low-power and High-power Switches ..............................................................................................28
Figure 12: Example of Two High-power Switches on the System Ports...............................................................................29
Figure 13: Example of Two High-power, Non-PoE+ Switches on the PoE+/System Ports ..................................................29
Figure 14: Example of One PoE+ Switch .............................................................................................................................30
Figure 15: Example of Two PoE+ Switches .........................................................................................................................31
Figure 16: Example of Low-power PoE+ and Non-PoE+ Switches ......................................................................................32
Figure 17: Example of Low-power PoE+ and Non-PoE+ Switches ......................................................................................33
Figure 18: Example of an Invalid Configuration - A ..............................................................................................................34
Figure 19: Example of an Invalid Configuration - B ..............................................................................................................35
Figure 20: Example of Power Modules and Non-PoE+ Switches.........................................................................................36
Figure 21: Two AT-PWR800 Modules Providing Up to 480 Watts, with Full Redundancy ................................................... 37
Figure 22: Two AT-PWR800 Modules for 480 to 960 Watts, with Limited Redundancy ......................................................38
Figure 23: Two AT-PWR1200 Modules Providing Up to 780 Watts, with Full Redundancy................................................. 38
Figure 24: Two AT-PWR1200 Modules for 780 to 1560 Watts, with Limited Redundancy ..................................................39
Figure 25: Example of x610 Series Switches and AT-RPS3000 Chassis with Different Power Supply Modules ................40
Figure 26: LED Panel ...........................................................................................................................................................42
Figure 27: Module A Ports LEDs ..........................................................................................................................................42
Figure 28: Module B Ports LEDs ..........................................................................................................................................43
Figure 29: Power Module Status LEDs.................................................................................................................................44
Figure 30: Power Module LED....................................................................................................
Figure 31: RPS Port On/Off Switches...................................................................................................................................47
Figure 32: 100 - 125 VAC 125 V NMA 5-20 Plug and Receptacle .......................................................................................52
Figure 33: Positioning the AT-RPS3000 Chassis in the Equipment Rack ............................................................................57
Figure 34: Unauthorized AT-RPS3000 Chassis and x610 Series Switch Installations......................................................... 57
Figure 35: Turning the Switch Upside Down ........................................................................................................................58
Figure 36: Removing the Plastic Feet...................................................................................................................................58
Figure 37: Attaching the Equipment Rack Brackets .............................................................................................................59
Figure 38: Mounting the AT-RPS3000 Redundant Power Supply in an Equipment Rack.................................................... 59
Figure 39: Removing the Blank Shipping Panel from the Back Panel..................................................................................61
Figure 40: Installing a Power Supply Module .......................................................................................................................62
Figure 41: Securing a Power Supply Module .......................................................................................................................63
Figure 42: Installing a Power Cord Retaining Clip ................................................................................................................63
Figure 43: Installing the Slot Cover.......................................................................................................................................64
Figure 44: Securing the Slot Cover.......................................................................................................................................64
Figure 45: Connecting the AT-RPS-CBL1.0 Cable to the x610 Series Switch .....................................................................65
Figure 46: Securing the AT-RPS-CBL1.0 Cable to the Switch .............................................................................................66
Figure 47: RPS Port On/Off Buttons and CABLE LEDs .......................................................................................................66
Figure 48: Connecting the AT-RPS-CBL1.0 Cable to the AT-RPS3000 Chassis.................................................................67
Figure 49: Securing the AT-RPS-CBL1.0 Cable to the AT-RPS3000 Chassis.....................................................................68
..........................................46
7
Page 8
Figures
Figure 50: Raising the Power Cord Retaining Clip ...............................................................................................................69
Figure 51: Connecting the AC Power Cord...........................................................................................................................70
Figure 52: Lowering the Power Cord Retaining Clip.............................................................................................................70
Figure 53: Lowering the Power Cord Retaining Clip.............................................................................................................71
Figure 54: Checking the FAN and DC OUT LEDs in the LED Panel ....................................................................................72
Figure 55: Checking the LOAD and CABLE LEDs in the LED Panel ...................................................................................73
Figure 56: Loosening the Thumbscrews that Secure the AT-RPS-CBL1.0 Cable to the AT-RPS3000 Chassis..................76
Figure 57: Removing the AT-RPS-CBL1.0 Cable from the AT-RPS3000 Chassis...............................................................77
Figure 58: Raising the Power Cord Retaining Clip ...............................................................................................................78
Figure 59: Removing the Power Cord...................................................................................................................................79
Figure 60: Loosening the Two Captive Screws ....................................................................................................................80
Figure 61: Removing the Power Supply from the Chassis ...................................................................................................80
Figure 62: Installing the Slot Cover.......................................................................................................................................81
Figure 63: Securing the Slot Cover.......................................................................................................................................81
Figure 64: Port Pin-outs for the RSP System and PoE+/System Ports ................................................................................89
8
Page 9

Tables

Table 1: Power Supply Modules ..........................................................................................................................................19
Table 2: Valid and Invalid Power Supply Combinations in the AT-RPS3000 Chassis ........................................................20
Table 3: Low-power and High-power Switches ..................................................................................................................24
Table 4: Valid and Invalid Configurations of Low- and High-power Switches for a Power Supply Module ........................24
Table 5: Power Supply Module Combinations for PoE+ Switches ......................................................................................40
Table 6: Module A and B Ports LEDs .................................................................................................................................43
Table 7: Power Module Status LEDs ..................................................................................................................................45
Table 8: Power Module LED ...............................................................................................................................................46
Table 9: AT-RPS3000 Chassis Components ......................................................................................................................54
Table 10: Power Supply Module Components ....................................................................................................................55
Table 11: RPS 1 and 3 System Ports ..................................................................................................................................89
Table 12: RPS 2 and 4 PoE+/System Ports ........................................................................................................................90
9
Page 10
Tables
10
Page 11

Preface

This guide contains the installation instructions for the AT-RPS3000 Chassis. The chassis is a modular power supply system for the x610 Series of Layer 3 Gigabit Ethernet switches. This preface contains the following sections:
“Document Conventions” on page 12
“Where to Find Web-based Guides” on page 13
“Contacting Allied Telesis” on page 14
11
Page 12
Preface
Note
Caution
Warning

Document Conventions

This document uses the following conventions:
Notes provide additional information.
Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data.
Warnings inform you that performing or omitting a specific action may result in bodily injury.
12
Page 13

Where to Find Web-based Guides

The installation and user guides for all of the Allied Telesis products are available for viewing in portable document format (PDF) from our web site at www.alliedtelesis.com/support/documentation.
AT-RPS3000 Redundant Power Supply Installation Guide
13
Page 14
Preface

Contacting Allied Telesis

This section provides Allied Telesis contact information for technical support and for sales and corporate information.

Online Support You may request technical support online by accessing the Allied Telesis

Knowledge Base: www.alliedtelesis.com/support. You may use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Email and Telephone
Support
For Technical Support via email or telephone, refer to the Support & Services section of the Allied Telesis web site: www.alliedtelesis.com/ support. Select your country from the list displayed on the website and then select the appropriate menu tab.

Warranty For hardware warranty information, refer to the Allied Telesis web site at

www.alliedtelesis.com/support.
Returning
Products
Sales or
Corporate
Products for return or repair must first be assigned a return materials authorization (RMA) number. A product sent to Allied Telesis without an RMA number will be returned to the sender at the sender’s expense.
To obtain an RMA number, contact the Allied Telesis Technical Support group at our web site: www.alliedtelesis.com/support. Select your country from the list displayed on the website. Then select the appropriate menu tab.
You can contact Allied Telesis for sales or corporate information through our web site at www.alliedtelesis.com. To find the contact information for your country, select Contact Us.
Information
Management
Software Updates
14
New releases of management software for our managed products are available on our Allied Telesis web site at http://www.alliedtelesis.com/ support.
Page 15

Chapter 1

Overview

This chapter contains the following sections:
“Features” on page 16
“Power Supply Modules” on page 19
“System Power and Power for PoE+” on page 21
“Low-power and High-power Switches” on page 24
“Configuration Examples” on page 25
“Choosing a Power Supply Module” on page 36
“LEDs” on page 42
“On/Off Power Switches” on page 47
“Guidelines” on page 48
15
Page 16
Chapter 1: Overview
Warning
Note
2148

LED Panel

Features

The AT-RPS3000 Chassis is a modular power supply system for the x610 Series of Layer 3 Gigabit Ethernet switches. It protects the switches from power supply failures and provides additional PoE+ power.
The chassis can support two or four x610 Series switches, depending on the switch model. It has two slots for power supply modules, an LED panel for viewing the status of the power modules, and four RPS connectors.
As explained in this overview, the power supply modules in the chassis function in either a redundant or an active state, depending on the switch model. For non-PoE+ x610 Series switches, the chassis acts as the active power source for the switches, whose own internal, non-removable power supplies function as backup modules. For PoE+ switches, the chassis acts as a redundant power supply for system power and in a load-sharing mode for PoE+ power.
The AT-RPS3000 Chassis is designed specifically for the x610 Series of Layer 3 Gigabit Ethernet switches and should not be used with any other product.
The AT-RPS3000 Chassis is not a battery backup unit. The power supply modules in the chassis have to be connected to active power sources to deliver power to the switches.
LED Panel The front panel of the AT-RPS3000 Chassis has an LED panel that
displays status information about the power supply modules and RPS ports. The LEDs are described in “LEDs” on page 42.
16
Figure 1. LED Panel
Page 17
AT-RPS3000 Redundant Power Supply Installation Guide
Note
Slot A Slot B
Slot A RPS 1 and 2 ports
Power Supply
Slots
A
A
The slots on the back panel of the chassis are for two power supply modules. The slots are labeled A and B.
1
B
SYSTEM
2
B
PoE+ / SYSTEM PoE+ / SYSTEM
MODULE A
SYSTEM
MODULE B
3
4
2166
Figure 2. Slots A and B for the Power Supply Modules
The chassis is shipped from the factory with a blank panel over the power supply slots.

RPS Connectors The four RPS connectors, which connect the chassis to up to four x610

Series switches, are paired with the power supply slots. RPS 1 and 2 ports receive power from the power supply module in slot A.
A
A
1
B
SYSTEM
2
B
PoE+ / SYSTEM PoE+ / SYSTEM
MODULE A
SYSTEM
MODULE B
3
4
2166
Figure 3. Slot A and RPS 1 and 2 Ports
17
Page 18
Chapter 1: Overview
Slot B
RPS 3 and 4 ports
2166
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
2206
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
RPS 3 and 4 ports obtain power from the power supply module in slot B.
Figure 4. Slot B and RPS 3 and 4 Ports
The ports are labeled System and PoE+/System ports. The System ports provide system power to x610 Series switches, but not PoE+ power. You may use these ports to deliver system power to PoE+ and non-PoE+ switches.
Figure 5. RPS Ports
The PoE+/System ports provide PoE+ power and system power, provided that the power modules and the switches support PoE+. For more information on the System and POE+/System ports, refer to “System Power and Power for PoE+” on page 21.
18
Page 19

Power Supply Modules

Note
This table lists the power supply modules that are currently available for the AT-RPS3000 Chassis and PoE+ x610 Series switches. One module supplies only system power to the x610 Series switches and two modules provide system power and PoE+ power.
AT-RPS3000 Redundant Power Supply Installation Guide
Table 1. Power Supply Modules
AT-PWR25 0
AT-PWR80 0
Power Supply Module
100-240VAC~ 5A MAX
AT-PWR250
100-240VAC~ 12A MAX
AT-PWR800
DC OUT FAULT
DC OUT FAULT
2186
Power
Source
Description
AC System power only.
2185
AC System power plus
480W for PoE+.
AC System power plus
780W for PoE+.
AT-PWR1200
DC OUT
100-240VAC~ 16A MAX
AT-PWR1200
FAULT
2187
There are AC and DC versions of the AT-PWR250 Module. The AC module is supported in the PoE+ x610 Switches and AT-RPS3000 Chassis. The DC module is only supported in the PoE+ x610 Switches. It is not supported in the AT-RPS3000 Chassis.
19
Page 20
Chapter 1: Overview
Note
The power supply modules for the AT-RPS3000 Chassis and PoE+ x610 Series switches must be purchased separately. Non-PoE+ x610 Series switches come with non-removable power supply modules.
The AT-PWR800 and AT-PWR1200 Modules are compatible with non-PoE+ x610 Series switches. They may be used in the AT-RPS3000 Chassis to provide active system power to non-PoE+ switches.
The chassis has slots for two power supply modules. You may install one or two modules. The power supply modules may be the same model or different models. There are some combinations of power supply modules, however, that are not supported. Table 2 lists the valid and invalid combinations of modules for the chassis.
Table 2. Valid and Invalid Power Supply Combinations in the AT-RPS3000
Chassis
Valid Combinations Invalid Combinations
Two power supply modules of the same model (for instance, two AT-PWR800 Modules)
One AT-PWR800 Module and one AT-PWR1200 Module
One AT-PWR800 Module and one AT-PWR250 Module
One AT-PWR1200 Module and one AT-PWR250 Module
20
Page 21
AT-RPS3000 Redundant Power Supply Installation Guide

System Power and Power for PoE+

Although the product name contains the acronym “RPS,” which stands for “redundant power supply,” the AT-RPS3000 Chassis actually functions as the active, primary source of system power for some of the switches in the x610 Series. For others it functions both as a redundant source of system power and as an active source of additional PoE+ power.
The easiest way to explain how and when the chassis supplies power to the x610 Series switch is to divide the discussion into the two types of power the switch may require:
“System Power,” next
“PoE+ Power” on page 22

System Power The switch uses system power to operate its switching, CPU, LEDs, fans,

and management functions. The only function not supported by system power is PoE+.
The switch may obtain its system power either from its own internal power supply module or from a module in the AT-RPS3000 Chassis. There is no load-sharing of system power. Consequently, one of the sources is going to be actively providing system power to the switch while the other source is held in a redundant state.
The active source of system power is different for non-PoE+ and PoE+ x610 Series switches. Non-PoE+ switches use the power modules in the AT-RPS3000 Chassis as their primary, active power source for system power, and place their internal power modules in a redundant state. Thus, a non-PoE+ switch relies upon the AT-RPS3000 Chassis to provide all of its system power, and activates its internal power supply only if it stops receiving system power from the chassis.
For PoE+ switches, the opposite is true. They use their internal power supply modules as the active source for system power, and the power module in the AT-RPS3000 Chassis as the redundant power source. Should there be a failure of the internal power supply in the switch or an interrupt in the AC power to it, the switch immediately begins to draw system power from the AT-RPS3000 Chassis to prevent any interruption to its network operations.
The easiest way to determine whether the switch is a PoE+ or non-PoE+ x610 Series switch is to examine its model name on the front panel. PoE+ switches have “POE+” in their product names. Another way is to look at the back panel to see if the power supply is removable or non-removable. PoE+ switches have removable power modules while non-PoE+ switches have non-removable modules, as shown in Figure 6.
21
Page 22
Chapter 1: Overview
POWER SUPPLY
WARNING This unit m electric sho unit.
AT-PW R800
100-240 VAC~5A MAX
POWER SUPPLY
WARNING This unit ma electric shoc unit.
2158
DC OUT
FAULT
100-240 VAC~12A MAX
Non-removable Power SupplyRemovable Power Supply
(PoE+ Switches)
(non-PoE+ Switches)
Figure 6. Removable and Non-removable Power Supply Modules in x610
Switches
To summarize, a non-PoE+ x610 Series switch uses the AT-RPS3000 Chassis as its active source of system power and its internal, non­removable module as a redundant source. For a PoE+ x610 Series switch the reverse is true because its primary source of system power is its removable internal module and the redundant source is the power module in the AT-RPS3000 Chassis.
System power for PoE+ and non-PoE+ x610 Series switches is provided by all four RPS ports on the AT-RPS3000 Chassis. RPS 1 and 3 System ports provide only system power, and RPS 2 and 4 PoE+/System ports provide PoE+ power in addition to system power.
You may use any of the available power supply modules, listed in Table 1 on page 19, to provide system power to the x610 Series switches. In fact, the modules, when installed in the AT-RPS3000 Chassis, can provide system power to two low-power switches at the same time, as explained in “Low-power and High-power Switches” on page 24.
The switch and chassis do not display the active or redundant status of a power supply module. You may use the LEDs and switch’s management software to determine whether a power module is operating correctly, but not whether it is the active or redundant system power for the switch.

PoE+ Power The four x610 Series switches that support PoE+ on the twisted pair ports

do not come with power supply modules. The modules have to be purchased separately. You may use any of the three modules in a PoE+ switch, although the AC AT-PWR250 Module does not provide PoE+ power, only system power. The AT-PWR800 and AT-PWR1200 Power Supply Modules provide 480 and 780 watts, respectively, of PoE+ power, in addition to system power.
As explained earlier in this Overview, there is no load sharing of system power between the power supplies in the switch and AT-RPS3000 Chassis. Only one source is active while the other is held in a redundant
22
state.
Page 23
AT-RPS3000 Redundant Power Supply Installation Guide
PoE+ power is different in that the power supplies in the switch and chassis do use load-sharing to provide power to the powered devices. This assumes, of course, that both supplies have PoE+ power. So, in essence, the AT-RPS3000 Chassis performs two roles for PoE+ switches. It acts as a redundant source of system power for the switches and, assuming the chassis has PoE+ power supplies, actively provides them with additional power for PoE+ so that they can support more powered devices.
Of the three available power supply modules for the chassis, two modules provide PoE+ power along with system power to the PoE+ switches. They are the AT-PWR800 and AT-PWR1200 Modules. These modules can provide PoE+ power to just one switch at a time, meaning that each PoE+ switch has to have a separate power module in the AT-RPS3000 Chassis, that is, if you want the switches to receive additional PoE+ power from the chassis.
All four RPS ports on the chassis may be used to provide system power to the switches. But only RPS 2 and 4 ports, labeled PoE+/System, may be used to supply PoE+ power. Thus, for a PoE+ switch to receive PoE+ power from a power supply in the chassis, it has to be connected to one of those ports. PoE+ switches that are connected to RPS 1 or 3 port will not receive extra PoE+ power, only redundant system power.
23
Page 24
Chapter 1: Overview
Caution

Low-power and High-power Switches

The x610 Series switches are grouped into two categories of system power, which, as explained earlier, refers to the power required to run all switching and hardware functions, except for PoE+. The switch categories are low-power and high-power. The basic rule is that switches that have 24 ports are low-power devices while units that have 48 ports are high­power units. An exception is the 24-port AT-x610-24SPs/X Switch, which is a high-power device. The table shown here lists the two switch categories.
Table 3. Low-power and High-power Switches
Low-power Switches High-power Switches
AT-x610-24Ts AT-x610-48Ts
AT-x610-24Ts/X AT-x610-48Ts/X
AT-x610-24Ts-POE+ AT-x610-48Ts-POE+
AT-x610-24Ts/X-POE+ AT-x610-48Ts/X-POE+
AT-x610-24SPs/X
The two categories are important because the power supply modules can support two low-power switches or one high-power switch at the same time. This table lists the valid and invalid configurations of low- and high­power switches for the power modules.
Table 4. Valid and Invalid Configurations of Low- and High-power
Switches for a Power Supply Module
Valid Configurations Invalid Configurations
One low-power switch One low-power switch and one
high-power switch
Two low-power switches Two high power switches
One high-power switch
24
A power supply module that is connected to an invalid configuration may overload and fail. The responsibility for adhering to the rule belongs to the installer because the AT-RPS3000 Chassis cannot determine the low- or high-power status of the switches connected to its ports.
Page 25

Configuration Examples

AT-x610-24Ts Switch
AT-RPS3000 Chassis
(Low-power)
with One Power Supply
Slot A
Slot B
RPS 1 System Port
The following examples illustrate different configurations of the chassis, switches, and power supply modules.
AT-RPS3000 Redundant Power Supply Installation Guide
Low-power
Switches
In the first example, the AT-RPS3000 Chassis, with one power supply module in slot A, is supporting a single low-power switch, connected to the RPS 1 System port. (The RPS 3 System and RPS 4 PoE+/System ports do not have power because slot B is empty.) The non-PoE+ AT-x610-24Ts Switch places its non-removable, internal power supply module in a redundant state, and receives all of its system power from the AT-RPS3000 Chassis and the power module in slot A. If there is an interruption of system power from the chassis, the switch automatically activates its internal power supply to maintain network operations.
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2140
Figure 7. Example of a Single Low-power Switch Connected to an RPS
System Port
It should be noted that even though the switch in the example is a non­PoE+ model, the power supply module in slot A can be any of the three available power modules, including the AT-PWR800 and AT-PWR1200 Modules. The three modules may be used to provide system power to PoE+ and non-PoE+ switches.
Non-PoE+ switches may be connected to either the RPS System or PoE+/ System port on the chassis. Non-PoE+ switches connected to an RPS PoE+/System port receive system power, but no power for PoE+, even if the power supply in the corresponding slot in the chassis contains a PoE+ module. This principal is illustrated in Figure 8 on page 26 where the single low-power, non-PoE+ switch from the previous example is now connected to the RPS 2 PoE+/System port, from which it receives just system power.
25
Page 26
Chapter 1: Overview
AT-x610-24Ts Switch
AT-RPS3000 Chassis
(Low-power)
with One Power Supply
Slot A
Slot B
RPS 2 PoE+/System Port
AT-x610-24Ts Switch
AT-x610-24Ts/X Switch
AT-RPS3000 Chassis
(Low-power)
(Low-power)
with One Power Supply
RPS 1 System Port
RPS 2 PoE+/System Port
Slot A
Slot B
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2141
Figure 8. Example of a Non-PoE+, Low-power Switch Connected to an
RPS PoE+/System Port
This example illustrates how a power supply module can provide system power to two low-power switches at the same time. The power supply module in slot A is actively supporting the low-power AT-x610-24Ts and AT-x610-24Ts/X Switches, which are connected to the RPS 1 System and RPS 2 PoE+/System ports, respectively. The power supply module in the chassis actively delivers system power to both switches, whose own non­removable internal power supplies operate in redundant states. Again, as in the previous example, the power module in slot A can be any of the available models because they are all capable of supporting up to two low­power switches.
26
A
AT-PWR800
A
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PNL 800/1200
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
3
SYSTEM
4
MODULE B
WARNING
100-240 VAC~12A MAX
This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
RPS READY
2135
100-240 VAC~12A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
RPS READY
Figure 9. Example of Two Low-power Switches
Page 27
AT-RPS3000 Redundant Power Supply Installation Guide
1. AT-x610-24Ts Switch
2. AT-x610-24Ts Switch
AT-RPS3000 Chassis with Two Power Supplies
3. AT-x610-24Ts Switch
4. AT-x610-24Ts/X Switch
Slot A Slot B
Low-power, Non-PoE+ Switches Powered by the Module in Slot A
Low-power, Non-PoE+ Switches Powered by the Module in Slot B
The chassis must have a second power supply to support three or four low-power switches, as illustrated in the following example. The power module in slot A supports switches 1 and 2, and the module in slot B powers switches 3 and 4.
The power supply modules in the chassis may be the same or different models. For instance, you might install two AT-PWR250 Modules or perhaps two AT-PWR1200 Modules. You may also combine the AT-PWR800 and AT-PWR1200 Modules in the chassis, installing one of each model in the slots. However, you may not combine the AT-PWR250 Module with the AT-PWR800 or AT-PWR1200 Module in the chassis, as explained in “Power Supply Modules” on page 19.
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
100-240 VAC~12A MAX
DC POWER
FAULT
RPS READY
RPS READY
RPS READY
RPS READY
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
3
SYSTEM
4
MODULE B
2138
Figure 10. Example of Four Low-power Switches
27
Page 28
Chapter 1: Overview
AT-x610-24Ts Switch
AT-x610-48Ts Switch
AT-RPS3000 Chassis
(Low-power)
(High-power)
with Two Power Supplies
Slot A Slot B
High-power
Switches
The power supply modules can support just one high-power switch at a time. In the example in Figure 11 on page 28, the chassis is supporting the AT-x610-24Ts and AT-x610-48Ts Switches, with two power supply modules, one for each switch. Even though the AT-x610-24Ts Switch is a low-power unit, the AT-x610-48Ts Switch must have its own dedicated power supply module because it is a high-power device.
A
AT-PWR 800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR 800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC POWER
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
3
SYSTEM
4
MODULE B
2136
Figure 11. Example of Low-power and High-power Switches
When a high-power, non-PoE+ switch is connected to the AT-RPS3000 Chassis, it responds just like a low-power switch. It places its internal power supply in the redundant state and draws its system power from the chassis.
In Figure 12 on page 29, the high-power, non-PoE+ AT-x610-48Ts and AT-x610-48Ts/X Switches are supported by separate power supply modules, with the AT-x610-48Ts Switch supported by the module in slot A and the AT-x610-48Ts/XSwitch powered by the module in slot B. If the chassis stops supplying system power to the switches, they activate their internal power supplies.
28
Page 29
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-48Ts Switch
AT-x610-48Ts/X Switch
AT-RPS3000 Chassis
(High-power)
(High-power)
with Two Power Supplies
Slot A Slot B
AT-x610-48Ts Switch
AT-x610-48Ts/X Switch
AT-RPS3000 Chassis
(High-power)
(High-power)
with Two Power Supplies
Slot A
Slot B
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC POWER
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
1
B
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
SYSTEM
3
SYSTEM
4
MODULE B
2136
Figure 12. Example of Two High-power Switches on the System Ports
You may use either the System or PoE+/System port to connect high­power, non-PoE+ switches to the chassis. To illustrate this point, the two high-power, non-PoE+ switches in the previous example may be connected to the PoE+/System ports, as shown here.
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
Figure 13. Example of Two High-power, Non-PoE+ Switches on the PoE+/
System Ports
3
SYSTEM
4
MODULE B
2139
29
Page 30
Chapter 1: Overview
AT-x610-24Ts/X-POE+ Switch
AT-RPS3000 Chassis
(Low-power)
with One Power Supply
RPS 2 PoE+/System Port
Slot A
Slot B

PoE+ Switches Here is an example of the AT-RPS3000 Chassis supporting a single PoE+

switch, the AT-x610-24Ts/X-POE+ Switch. Notice that the switch is connected to RPS 2 PoE+/System port on the chassis so that it receives both system and PoE+ power from the power module in slot A. It would receive only system power if it was connected to RPS 1 System port.
A
AT-PWR800
A
AT-PWR800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2142
Figure 14. Example of One PoE+ Switch
The active source of system power for the switch is its internal, removable power supply. This is in keeping with the rule that PoE+ switches gain their system power from their internal power supply, and use the power supply in the AT-RPS3000 Chassis as a redundant supply for system power.
It is important to note, however, that the principal of active and redundant system power does not apply to PoE+ power because the AT-RPS3000 Chassis supplements the PoE+ power from the switch’s internal power supply, thus allowing for more powered devices on the switch.
30
The AT-PWR800 and AT-PWR1200 Modules can provide PoE+ power to just one switch at a time. Consequently, the chassis must have a second module if it is to support two PoE+ switches. In Figure 15 on page 31, the AT-x610-24Ts/X-POE+ and AT-x610-48Ts/X-POE+ Switches receive redundant system power and additional PoE+ power from the modules in slot A and B, respectively.
Page 31
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-24Ts/X-POE+ Switch
AT-RPS3000 Chassis
(Low-power)
with Two Power Supplies
RPS 4 PoE+/System Port
AT-x610-48Ts/X-POE+ Switch (High-power)
RPS 2 PoE+/System Port
Slot A
Slot B
A
AT-PWR 800
A
AT-PWR 800
AT-PWR800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR 800
DC OUT
FAULT
DC OUT
FAULT
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC POWER
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
1
B
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
SYSTEM
3
SYSTEM
4
MODULE B
2143
Figure 15. Example of Two PoE+ Switches
In Figure 16 on page 32, two low-power switches are supported by a single power supply module, in slot A of the chassis. One switch supports PoE+ while the other does not. (Remember, the terms low- and high­power do not refer to the PoE+ feature. A switch that supports the PoE+ feature may be a low- or high-power device.) Because it is a non-PoE+ switch, the AT-x610-24Ts Switch is connected to RPS 1 System port, from which it receives system power for its switching functions. In contrast, the AT-x610-24Ts/X-POE+ Switch is connected to the RPS 2 System/PoE+ to receive redundant system power and active PoE+ power.
31
Page 32
Chapter 1: Overview
AT-x610-24Ts Switch
AT-x610-24Ts/X-POE+ Switch
AT-RPS3000 Chassis
(Low-power)
(Low-power)
with One Power Supply
Slot A
Slot B
A
AT-PWR800
A
AT-PWR800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
RPS READY
3
SYSTEM
4
MODULE B
2144
Figure 16. Example of Low-power PoE+ and Non-PoE+ Switches
The AT-PWR800 or AT-PWR1200 Module in slot A is performing three functions for the two switches. It is acting as the active source of system power for the AT-x610-24Ts Switch connected to RPS 1 System port, as a redundant source of system power for the AT-x610-24Ts-POE+ connected to the RPS 2 PoE+/System port, and as an active source of addition PoE+ power for the PoE+ switch.
32
The example in Figure 17 on page 33 builds on the previous example, adding a power supply module to slot B and two more low power PoE+ and non-PoE+ switches.
Page 33
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-24Ts Switch
AT-x610-24Ts-POE+ Switch
AT-RPS3000 Chassis
(Low-power)
(Low-power)
with Two Power Supplies
Slot A
Slot B
AT-x610-24Ts/X Switch
AT-x610-24Ts/X-POE+ Switch
(Low-power)
(Low-power)
Switches supported by the Power Module in Slot A.
Switches supported by the Power Module in Slot B.
A
AT-PWR800
A
AT-PWR800
AT-PWR800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
FAULT
DC OUT
FAULT
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
3
SYSTEM
4
MODULE B
2211
Configurations
Invalid
Figure 17. Example of Low-power PoE+ and Non-PoE+ Switches
Here are examples of invalid configurations. In the first example in Figure 18 on page 34, two low-power, non-PoE+ switches are connected to RPS 1 and 3 System ports on a chassis that has one power module in slot A. While it is true that you may use one power supply module to supply system power to two low-power switches, you have to be sure to connect the switches to the correct ports. The power supply module in slot A delivers power to RPS 1 and 2 ports. RPS 3 and 4 ports are not receiving any power because slot B is empty. To correct the problem, you could connect the AT-x610-24Ts/X Switch to RPS 2 PoE+/System port on the chassis or install another power supply module.
33
Page 34
Chapter 1: Overview
AT-x610-24Ts Switch
AT-x610-24Ts/X Switch
AT-RPS3000 Chassis
(Low-power)
(Low-power)
with One Power Supply
Slot A
Slot B
A
AT-PWR 800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
RPS READY
RPS READY
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
3
SYSTEM
4
MODULE B
2211
Figure 18. Example of an Invalid Configuration - A
In the example in Figure 19 on page 35, the power supply in slot A is supporting a low-power switch and a high-power switch. This configuration is invalid because the power supply modules can support only one switch if it is a high-power switch. You could resolve the problem by installing a power supply module in slot B and connecting one of the switches to RPS port 3 or 4. The resolution is shown in Figure 11 on page 28.
34
Page 35
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-24Ts Switch
AT-x610-48Ts Switch
AT-RPS3000 Chassis
(Low-power)
(High-power)
with One Power Supply
Slot A
Slot B
A
AT-PWR800
A
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
RPS READY
Figure 19. Example of an Invalid Configuration - B
3
SYSTEM
4
MODULE B
2135
35
Page 36
Chapter 1: Overview
Low-power, non-PoE+
switches powered by
the module in slot A.
Low-power, non-PoE+
switches powered by
the module in slot B.
Low-power, non-PoE+
switch powered by
the module in slot A.
High-power, non-PoE+
switch powered by
the module in slot B.
High-power, non-PoE+
switch powered by
the module in slot A.

Choosing a Power Supply Module

Here are a few suggestions on how to choose the power supply modules for the x610 Series switches and AT-RPS3000 Chassis.
Non-PoE+
Switches
DC OUT
A
FAULT
100-240 VAC~12A MAX
AT-PWR800
A
100-240 VAC~12A MAX
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
You may use any of the three available power supply modules listed in Table 1 on page 19, even the two PoE+ modules, in the AT-RPS3000 Chassis to provide active system power to non-PoE+ switches. The switches may be connected to any of the four RPS connectors on the chassis.
A power module can support two low-power switches or one high-power switch. For more information, refer to “Low-power and High-power Switches” on page 24.
Here is an example. If you have five low-power and two high-power non­PoE+ x610 Series switches, you would need five power modules, of any model, and three chassis. The five low-power switches would need three modules and the high-power switches two modules. The power modules can be the same model, such as all AT-PWR800 Modules, or different models.
DC OUT
DC OUT
1
B
FAULT
100-240 VAC~12A MAX
2
B
RPS INPUT
RPS READY
12V/21A MAX
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
MODULE A
3
SYSTEM
4
MODULE B
DC OUT
A
FAULT
100-240 VAC~12A MAX
AT-PWR800
A
100-240 VAC~12A MAX
AT-PWR800
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
1
B
FAULT
100-240 VAC~12A MAX
2
B
RPS INPUT
RPS READY
12V/21A MAX
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
MODULE A
3
SYSTEM
4
MODULE B
A
AT-PWR800
A
AT-PNL800/1200
FAULT
100-240 VAC~12A MAX
WARNING This unit may have more than one power input. To reduce the risk of
100-240 VAC~12A MAX
electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
2
B
RPS READY
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
MODULE A
3
SYSTEM
4
MODULE B
2211
WARNING This unit may have more than one power input. To reduce the risk of
100-240 VAC~12A MAX
electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of
100-240 VAC~12A MAX
electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of
100-240 VAC~12A MAX
electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
36
WARNING This unit may have more than one power input. To reduce the risk of
100-240 VAC~12A MAX
electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
POWER SUPPLY
RPS READY
12V/21A MAX
Figure 20. Example of Power Modules and Non-PoE+ Switches
Page 37
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-24Ts/X-POE+
AT-RPS3000 Chassis
Switch with powered devices
AT-PWR800 Module
AT-PWR800 Module
requiring up to 480 watts

PoE+ Switches The PoE+ switches do not come with power supplies. You must purchase

them separately and install them as part of the switch’s installation procedure.
The only way to determine which power module is appropriate for a PoE+ switch is to determine the amount of power the powered devices connected to the switch will require. The powered requirements of the devices can be found in their documentation.
If the power requirements of the power devices of the switch are below 480 watts, you may use the AT-PWR800 Module. If you want PoE+ redundancy, you would also install an AT-PWR800 Module in the AT-RPS3000 Chassis.
A
AT-PWR800
A
AT-PWR 800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2142
Figure 21. Two AT-PWR800 Modules Providing Up to 480 Watts, with Full
Redundancy
If the total power requirements of the devices on a PoE+ switch are greater than 480 watts, you have two possible solutions to providing the necessary power. If the power requirement is between 480 and 960 watts, you could use the load-sharing property of two AT-PWR800 Modules to provide up to 960 watts, as shown in Figure 22 on page 38. The drawback to this approach is that PoE+ redundancy extends only to 480 watts, the power supplied by a single power module. If one of the power supplies were to stop functioning, the switch would have to deny power to some powered devices.
For example, if the powered devices on the AT-x610-24Ts/X-POE+ Switch required 550 watts, the two AT-PWR800 Modules would each provide half, or 275 watts, of the power requirements of the devices. If power is lost on one of the power supplies, the remaining power module will supply up to 480 watts of power to the switch, which, being short 70 watts, will have to deny power to some of the devices.
37
Page 38
Chapter 1: Overview
AT-x610-24Ts/X-POE+
AT-RPS3000 Chassis
Switch with powered devices
AT-PWR800 Module
AT-PWR800 Module
requiring 480 to 960 watts
AT-x610-24Ts/X-POE+
AT-RPS3000 Chassis
Switch with powered devices
AT-PWR1200 Module
AT-PWR1200 Module
requiring up to 780 watts
A
AT-PWR800
A
AT-PWR800
100-240 VAC~12A MAX
100-240 VAC~12A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2142
Figure 22. Two AT-PWR800 Modules for 480 to 960 Watts, with Limited
Redundancy
Another approach to dealing with a PoE+ switch that needs more than 480 watts for its powered devices is with the AT-PWR1200 Module. This module can provide 780 watts. If you install this module in both the switch and chassis, the switch will have PoE+ power redundancy up to 780 watts.
38
A
AT-PWR1200
A
AT-PWR1200
100-240 VAC~16A MAX
100-240 VAC~16A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
Figure 23. Two AT-PWR1200 Modules Providing Up to 780 Watts, with
Full Redundancy
For example, if the total power requirements of the devices connected to the switch is 720 watts, each AT-PWR1200 Module would be responsible for providing 360 watts. A failure of one power supplies will not affect the ability of the switch to support all of the powered devices, because the power capacity of the remaining AT-PWR1200 Module will be adequate to meet the needs of all the devices.
3
SYSTEM
4
MODULE B
2165
Page 39
AT-RPS3000 Redundant Power Supply Installation Guide
AT-x610-48Ts-POE+
AT-RPS3000 Chassis
Switch with powered devices
AT-PWR1200 Module
AT-PWR1200 Module
consuming 780 to 1560 watts
Two AT-PWR1200 Modules may be used for amounts above 780 watts, up to 1560 watts, but there is no redundancy for power requirements above 780 watts.
A
AT-PWR1200
A
AT-PWR1200
100-240 VAC~16A MAX
100-240 VAC~16A MAX
DC OUT
FAULT
DC OUT
FAULT
AT-PNL800/1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
RPS INPUT
POWER SUPPLY
12V/21A MAX
1
B
SYSTEM
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
RPS READY
3
SYSTEM
4
MODULE B
2165
Figure 24. Two AT-PWR1200 Modules for 780 to 1560 Watts, with Limited
Redundancy
The power modules in the switches and chassis in the examples up to this point have been the same model. But as shown in Figure 25 on page 40, they can be different. The example shows a chassis that is supporting three switches, two of which are low-power and one is high-power.
39
Page 40
Chapter 1: Overview
AT-x610-24Ts Switch
AT-RPS3000 Chassis
(low-power)
AT-x610-24Ts/X-POE+ Switch (low-power) with the AT-PWR1200 Module and powered devices
AT-PWR800
Module
AT-PWR1200
Module
AT-PWR800
Module
requiring 420 watts.
AT-x610-48Ts-POE+ Switch (high-power) with the AT-PWR250 Module and powered devices requiring 710 watts.
A
AT-PWR800
A
AT-PWR1200
AT-PWR250
100-240 VAC~12A MAX
100-240 VAC~12A MAX
100-240 VAC~16A MAX
100-240 VAC~5A MAX
DC OUT
FAULT
AT-PWR1200
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
FAULT
DC OUT
FAULT
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
WARNING This unit may have more than one power input. To reduce the risk of electric shock, disconnect both A/C and RPS inputs before servicing unit.
POWER SUPPLY
DC OUT
FAULT
100-240 VAC~12A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS READY
12V/21A MAX
RPS INPUT
RPS
READY
12V/21A MAX
1
B
2
PoE+ / SYSTEM PoE+ / SYSTEM
B
MODULE A
SYSTEM
3
SYSTEM
4
MODULE B
2154
Figure 25. Example of x610 Series Switches and AT-RPS3000 Chassis
with Different Power Supply Modules
Power Module
Combinations for
The following table may be of assistance to you in selecting power supply modules for PoE+ switches. It lists the various combinations of power modules for the switch and AT-RPS3000 Chassis, and the available PoE+
PoE+ Switches
power. It should be noted that it does not matter which module is in the switch and which is in the chassis. For example, in option 4, the AT-PWR800 Module could be in the AT-RPS3000 Chassis and the AT-PWR250 Module in the switch. Or it could be the other way around, with the AT-PWR250 Module in the chassis and the AT-PWR800 Module in the switch.
Table 5. Power Supply Module Combinations for PoE+ Switches
Power Supply
Module 1
Power Supply
Module 2
Range of PoE+
Power with
Redundancy
Range of PoE+
Power without
Redundancy
1 AT-PWR250 -- None None No
2 AT-PWR250 AT-PWR250 None None Yes
40
System Power
Redundancy
Page 41
AT-RPS3000 Redundant Power Supply Installation Guide
Table 5. Power Supply Module Combinations for PoE+ Switches
Power Supply
Module 1
Power Supply
Module 2
Range of PoE+
Power with
Redundancy
Range of PoE+
Power without
Redundancy
System Power
Redundancy
3 AT-PWR800 -- None 0 to 480 watts No
4 AT-PWR800 AT-PWR250 None 0 to 480 watts Yes
5 AT-PWR800 AT-PWR800 0 to 480 watts 481 to 960
Yes
watts
6 AT-PWR1200
--
None 0 to 780 watts No
7 AT-PWR1200 AT-PWR250 None 0 to 780 watts Yes
8 AT-PWR1200 AT-PWR800 0 to 480 watts 481 to 1260
Yes
watts
9 AT-PWR1200 AT-PWR1200 0 to 780 watts 781 to 1440
Yes
watts
41
Page 42
Chapter 1: Overview
LED Panel
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
2156

LEDs

On the front panel of the AT-RPS3000 Chassis is an LED panel that displays status information about the power supply modules and RPS ports.
2148
Figure 26. LED Panel
Module A/B Ports
LEDs
The LEDs in the Module A Ports section of the LED panel provide information about the status of RPS ports 1 and 2, which receive their power from the power supply module in slot A.
Figure 27. Module A Ports LEDs
42
Page 43
AT-RPS3000 Redundant Power Supply Installation Guide
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
2157
100-240 VAC~12A MAX
The LEDs in the Module B Ports section provide information you may use to monitor RPS ports 3 and 4, whose power is provided by the power supply module in slot B.
Figure 28. Module B Ports LEDs
The LEDs are described in this table.
Table 6. Module A and B Ports LEDs
LED State Description
LOAD Green The port is operating normally.
Amber The port has encountered a problem.
Off This LED state indicates one of the
following:
The port is disabled.
There is no power supply in the power
supply slot.
The power supply is powered off.
43
Page 44
Chapter 1: Overview
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
Table 6. Module A and B Ports LEDs (Continued)
LED State Description
CABLE Green The RPS port is enabled and connected
to an x610 Series switch, and the power supply module is powered on.
Amber The RPS port is not connected to an x610
Series switch.
Off This LED state indicates one of the
following:
The RPS port is disabled.
The power supply slot is empty.
The power supply module is not
powered on.
The power supply module has failed.
Power Module
Status LEDs
For general status information about the power supply modules, refer to the FAN and DC OUT LEDs in the Power Module Status section of the LED panel.
Figure 29. Power Module Status LEDs
44
Page 45
AT-RPS3000 Redundant Power Supply Installation Guide
Table 7 describes the Power Module Status LEDs.
Table 7. Power Module Status LEDs
LED State Description
FAN Green The power module’s fans are operating
normally.
Amber One or both fans in the module have
stopped or are operating below their normal operating speed.
Off No power supply module is installed in the
module slot.
DC OUT Green The DC output from the power supply
module to the RPS ports is within the normal operating range.
Amber The DC output from the power supply
module is below the normal operating range, either because the module is failing or the input voltage from the AC power source is below the normal operating range.
Off The module is not receiving any AC
power or the slot is empty.
TEMP Green The temperatures inside the power supply
modules are in the normal operating range.
Amber One of the power supply modules is
experiencing an increase in temperature that exceeds the normal operating range. The affected module is continuing to provide system power to its two RPS ports, but has stopped providing PoE+ power to the PoE+/System port. To determine which power supply in the chassis is overheating, use the SHOW SYSTEM ENVIRONMENT command in the management software on the x610 Series switch.
45
Page 46
Chapter 1: Overview
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
DC OUT
FAULT
100-240 VAC~12A MAX
2162
Power Module
LED
The power modules have a DC OUT/FAULT LED, shown in Figure 30 on page 46, that displays the same information as the DC OUT LEDs on the front panel.
Figure 30. Power Module LED
Table 8 describes the Power Module LED.
Table 8. Power Module LED
LED State Description
DC OUT/ FAULT
Green The DC output from the power supply
module is within the normal operating range.
Amber The DC output from the power supply
module is below the normal operating range, either because the module is failing or the input voltage from the AC power source is below the normal operating range.
Off The module is not receiving any AC
power.
46
Page 47

On/Off Power Switches

Caution
2207
RPS Port 1
Switch
RPS Port 2
Switch
RPS Port 3
Switch
RPS Port 4
Switch
The LED panel has On/Off switches that control the RPS ports. You may use the buttons to turn the ports on or off. When the chassis is operational, you should always turn off a port before connecting or disconnecting its RPS cable.
AT-RPS3000 Redundant Power Supply Installation Guide
Figure 31. RPS Port On/Off Switches
The electronic circuitry inside the chassis may be damaged if you do not turn off an RPS port before connecting or disconnecting the RPS cable.
Review the following before turning off an RPS port on the chassis:
Turning off an RPS port stops the transmission of system power. The
switch that is connected to the RPS port will stop functioning if it is completely dependent on the AT-RPS3000 Chassis for its system power, either because its internal power supply has failed or been removed.
Turning off an PoE+/System port also stops the transmission of PoE+
power. A PoE+ switch may support fewer powered devices or stop supporting all devices, depending on whether its internal power module supports PoE+.
47
Page 48
Chapter 1: Overview
Caution

Guidelines

Here is a summary of the rules and guidelines discussed in this chapter:
The AT-RPS3000 Chassis is designed specifically for the x610 Series of Layer 3 Gigabit Ethernet switches. It should not be used with any other product.
You may install up to two power supply modules in the chassis.
The power supply module in slot A (left-hand slot as you face the rear
panel) provides power to the RPS 1 System and RPS 2 PoE+/System ports.
The power supply module in slot B (right-hand slot) provides power to
the RPS 3 System and RPS 4 PoE+/System ports.
The AT-RPS3000 Chassis can support two power modules of the
same type, such as two AT-PWR800 Modules, or one AT-PWR800 Module and one AT-PWR1200 Module. All other combinations are not allowed, as explained in “Power Supply Modules” on page 19.
The AT-PWR250 Power Supply Module may be used to provide
system power to two low-power switches or one high-power switch. The module does not provide PoE+ power,
The AT-PWR800 and AT-PWR1200 Modules may be used to supply
system power to two low-power switches or one high-power switch. They may also be used to provide 480W or 780W, respectively, of additional PoE+ power to one PoE+ switch.
You may use the AT-PWR800 and AT-PWR1200 Modules in the
AT-RPS3000 Chassis to provide redundant system power to non­PoE+ switches. The modules provide redundant system power but no power for PoE+ for non-PoE+ switches.
You may connect a non-PoE+ switch to either an RPS System or RPS
PoE+/System port on the chassis.
The AT-PWR800 and AT-PWR1200 Modules can supply PoE+ power
to just one switch at a time.
A PoE+ switch has to be connected to the RPS 2 or 4 PoE+/System
port to receive PoE+ power from the chassis.
The power supply in the switch does not have to be the same type as
the power supply in the AT-RPS3000 Chassis. For example, a switch that contains the AT-PWR250 Module may be connected to an AT-PWR1200 Module in the AT-RPS3000 Chassis.
48
If the chassis is operational, you should always turn off an RPS port
with the appropriate On/Off port switch, in the LED panel, before connecting or disconnecting an RPS cable.
Page 49

Chapter 2

Installing the AT-RPS3000 Chassis and Power Supply Modules

Here are the installation procedures for the AT-RPS3000 Chassis:
“Reviewing Safety Precautions” on page 50
“Planning the Installation” on page 52
“Unpacking the AT-RPS3000 Chassis and Power Supply Modules” on
page 54
“Selecting a Location for the AT-RPS3000 Chassis in the Equipment
Rack” on page 57
“Installing the AT-RPS3000 Chassis in an Equipment Rack” on
page 58
“Installing a Power Supply Module” on page 61
“Connecting the AT-RPS3000 Chassis to the x610 Series Switch” on
page 65
“Powering On the Power Supply Modules” on page 69
49
Page 50
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Note

Reviewing Safety Precautions

Please review the following safety precautions before installing the unit.
The  indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” (613-
000405) posted on the Allied Telesis website at www.alliedtelesis.com.
Warning: To prevent electric shock, do not remove the cover. No user-serviceable parts inside. This unit contains hazardous voltages and should only be opened by a trained and qualified technician. To avoid the possibility of electric shock, disconnect electric power to the product before connecting or disconnecting the LAN cables.
E1
Warning: Do not work on equipment or cables during periods of lightning activity.
Warning: Power cord is used as a disconnection device. To de­energize equipment, disconnect the power cord.
Warning: Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Pluggable Equipment. The socket outlet shall be installed near the equipment and shall be easily accessible.
Caution: Air vents must not be blocked and must have free access to the room ambient air for cooling.
Warning: Operating Temperature. This product is designed for a maximum ambient temperature of 40° degrees C.
E2
E6
E5
E3
E7
E4
50
All Countries: Install product in accordance with local and National Electrical Codes.
E8
Page 51
AT-RPS3000 Redundant Power Supply Installation Guide
Circuit Overloading: Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Warning: Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading.
Warning: This unit might have more than one power cord. To reduce the risk of electric shock, disconnect all power cords before servicing the unit.
If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
E21
E25
E35
E30
Caution: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the
E37
E36
E42
E44
equipment is not compromised.
Warning: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips).
Caution: This unit does not contain serviceable components. Please return damaged units for servicing
Caution: An Energy Hazard exists inside this equipment. Do not insert hands or tools into open chassis slots or sockets.
Warning: This equipment shall be installed in a Restricted
Access location.
E45
51
Page 52
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules

Planning the Installation

Observe these requirements when planning the installation:
Verify that the equipment rack containing the x610 Series switches has
adequate space for the AT-RPS3000 Chassis. For further information, refer to “Selecting a Location for the AT-RPS3000 Chassis in the Equipment Rack” on page 57.
Check that the rack is safely secured and will not tip over. Devices in a
rack should be installed starting at the bottom, with the heavier devices near the bottom of the rack.
Check that the power outlets are located near the chassis and are
easily accessible.
If you are installing the AT-PWR1200 Power Supply Module in North
America, verify that the AC power source has an NEMA 5-20R receptacle. The power cord that comes with the AT-PWR1200 Power Supply Module for installations in North America has a 20 Amp, 125 V NEMA 5-20P plug that is only compatible with an NEMA 5-20R receptacle.
G
W
1965
Figure 32. 100 - 125 VAC 125 V NMA 5-20 Plug and Receptacle
Verify that the site provides easy access to the front and rear panels of
the chassis. This will make it easy for you to install the power modules, view the LEDs, and connect and disconnect the power and RPS cables.
Check that the site allows for adequate air flow around the units and
through the cooling vents on the front and rear panels. (The ventilation flow is from front to back, with the fans on the power supply modules drawing air out of the unit.)
Do not place objects on top of the chassis.
52
Page 53
AT-RPS3000 Redundant Power Supply Installation Guide
Do not expose the chassis to moisture or water.
Make sure the site is a dust-free environment.
Use dedicated power circuits or power conditioners to supply reliable
electrical power to the network devices.
Do not install the device in a wiring or utility box. The device will
overheat and fail from inadequate airflow.
53
Page 54
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Note

Unpacking the AT-RPS3000 Chassis and Power Supply Modules

Refer to the tables in this section to verify the contents of the shipping containers of the AT-RPS3000 Chassis and power supply modules.
You should retain the original packaging material in the event you need to return the unit to Allied Telesis.
AT-RPS3000
Chassis
The shipping container for the AT-RPS3000 Chassis should contain the components listed in this table.
Table 9. AT-RPS3000 Chassis Components
Component Description
One AT-RPS3000 Redundant Power Supply Chassis
2131
Two rack mounting brackets
2181
54
AT-PNL250
Twelve bracket screws
2047
One AT-PNL250 Blank Panel
2159
Page 55
AT-RPS3000 Redundant Power Supply Installation Guide
Note
2184
Table 9. AT-RPS3000 Chassis Components
Component Description
One AT-PNL800/1200
AT-PNL800/ 1200
2160
Blank Panel
Blank shipping panel (pre­installed on the power supply slots on the back panel)
2189
Power Supply
Modules
Power Supply
Module
AT-PWR250
AT-PWR800
The AT-RPS3000 Chassis is connected to an x610 Series switch with the AT-RPS-CBL1.0 cable. The cable must be purchased separately. You will need one cable for each x610 Series switch.
Refer to this table to verify the items in the shipping containers of the power supply modules.
Table 10. Power Supply Module Components
AT-PWR250
AT-PWR800
Module
100-240VAC~ 5A MAX
100-240VAC~ 12A MAX
Power Cord
Retaining Clip
DC OUT FAULT
2185
DC OUT FAULT
2186
2184
Regional Power
Cord
55
Page 56
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Note
Note
Table 10. Power Supply Module Components (Continued)
Power Supply
Module
Module
Power Cord
Retaining Clip
AT-PWR1200 None.
DC OUT FAULT
100-240VAC~ 16A MAX
AT-PWR1200
2187
The power cord that comes with the AT-PWR1200 Power Supply Module for installations in North America has a 20 Amp, 125 V NEMA 5-20P plug that is only compatible with an NEMA 5-20R receptacle.
There are AC and DC versions of the AT-PWR250 Module. The AC module is supported in the PoE+ x610 Switches and the AT-RPS3000 Chassis. The DC module is only supported in the PoE+ x610 Switches. It is not supported in the AT-RPS3000 Chassis.
Regional Power
Cord
56
Page 57
AT-RPS3000 Redundant Power Supply Installation Guide

Selecting a Location for the AT-RPS3000 Chassis in the Equipment Rack

The AT-RPS3000 Chassis has to be installed in the same equipment rack as the x610 Series switches. You may install it above, below, or between the switches. This may require relocating networking equipment to other equipment racks if there is currently no available space for the chassis in the rack.
x610-24Ts-POE+
x610-24Ts/X
x610-24Ts
x610-24Ts-POE+
x610-24Ts-POE+
x610-24Ts-POE+
x610-24Ts/X
x610-24Ts
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
BUSY
FAULT
READY
2321
SFP
SD
1
CLASS LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
26
10G
24
22
1000 / 100
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
x610-24Ts-POE+
x610-24Ts-POE+
x610-24Ts/X
x610-24Ts
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
FDX HDX COL
BUSY
FAULT
READY
2321
SFP
SD
1
CLASS LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
26
10G
24
22
1000 / 100
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
x610-24Ts-POE+
x610-24Ts-POE+
x610-24Ts/X
x610-24Ts
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
BUSY
FAULT
READY
2321
SFP
SD
1
CLASS
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
26
10G
24
1000 / 100
22
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
2190
Figure 33. Positioning the AT-RPS3000 Chassis in the Equipment Rack
This figure illustrates three arrangements that are not recommended for the chassis and switches. You should not install the devices in adjacent equipment racks or alongside each other on a tabletop because that would require twisting the AT-RPS-CBL1.0 Cables, which may damage them. In addition Allied Telesis does not recommend stacking the chassis and switches on a table because that could create an unsafe workplace.
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
26
10G
24
22
1000 / 100
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
x610-24Ts-POE+
x610-24Ts-POE+
x610-24Ts/X
x610-24Ts
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
BUSY
FAULT
READY
2321
SFP
SD
CLASS
1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
22
1000 / 100
BUSY
FAULT
READY
2321
SFP
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1
LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
26
10G
24
1000 / 100
22
FDX HDX COL
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
FDX HDX COL
x610-24Ts/X
3 51791113 15 17 19 21R 23R
4 6 8 10 122 16 18 20 22R 24R14
SFP+
25
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWRPRES
26
10G
24
22
1000 / 100
FDX HDX COL
x610-24Ts
3 51791113 15 17 19 21R 23R
46810122 16 18 20 22R 24R14
FDX HDX COL
2321
SFP
BUSY
FAULT
READY
SD
CLASS 1 LASER PRODUCT
STATUS
STACK
FAULT
MSTR
L/A
1
MASTER
L/A
2
RPS PWR
PRES
24
1000 / 100
22
2191
Figure 34. Unauthorized AT-RPS3000 Chassis and x610 Series Switch
Installations
Go to “Installing the AT-RPS3000 Chassis in an Equipment Rack” on page 58.
57
Page 58
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Warning
2168

Installing the AT-RPS3000 Chassis in an Equipment Rack

Perform this procedure to install the chassis in a 19-inch equipment rack. The procedure requires the following items:
Twelve bracket screws (included with chassis)
Two equipment rack brackets (included with chassis)
Flat-head screwdriver (not provided)
Cross-head screwdriver (not provided)
Four standard equipment rack screws (not provided)
The chassis may be heavy and awkward to lift. Allied Telesis recommends that you get assistance when mounting the chassis in an equipment rack.  E28
1. Place the unit upside down on a level, secure surface.
2180
Figure 35. Turning the Switch Upside Down
2. Using a flat-head screwdriver, pry the six plastic feet from the bottom of the switch.
58
Figure 36. Removing the Plastic Feet
Page 59
AT-RPS3000 Redundant Power Supply Installation Guide
2182
2151
3. Turn the chassis over.
4. Using a cross-head screwdriver, secure the two rack mount brackets to the sides of the unit using the twelve bracket screws included with the unit. The illustration shows the only way in which the brackets may be positioned on the chassis.
Figure 37. Attaching the Equipment Rack Brackets
5. Have another person hold the unit in the equipment rack while you secure it using standard screws (not provided).
Figure 38. Mounting the AT-RPS3000 Redundant Power Supply in an
Equipment Rack
59
Page 60
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Note
The chassis and x610 Series switches must be within one meter of each other in the equipment rack to accommodate the AT-RPS-CBL1.0 cables.
6. Go to “Installing a Power Supply Module” on page 61.
60
Page 61

Installing a Power Supply Module

Caution
Note
To install a power supply unit module in the chassis, perform this procedure:
1. Using a cross-head screwdriver, remove the three screws that secure the blank shipping panel, from the back panel of the chassis.
A
A
B
1
2
B
AT-RPS3000 Redundant Power Supply Installation Guide
SYSTEM
PoE+ /
SY
STEM
M
O
D
U L
E
A
3
SYSTEM
4
PoE+ /
SY
STEM
M
O
D
U
L
E
B
2167
Figure 39. Removing the Blank Shipping Panel from the Back Panel
2. Orient the new power supply module as shown in Figure 40 on page 62 and slide it into the slot until the tabs with the captive screws are flush with the back panel of the chassis. (If you are installing only one power supply module, you may install it in either slot.) Light pressure may be required to properly seat the module on the power connector inside the chassis.
Do not use excessive force when seating the module, because this may damage the system or the module. If the module resists seating, remove it from the system, realign it, and try again.  E47
When installed, the AT-PWR1200 Module extends 5.6 cm (2.2 in.) from the back panel of the chassis.
61
Page 62
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Caution
2152
A
A
AT-PWR800
D
C O
U T
F
A U
L T
1
0 0
­2 4 0
VAC
~
1
2 A
M
A
X
A
A
AT-PWR1200
D
C
O U
T
F
A U
L T
1
00-2
40
V A
C
~
1 6
A M
A X
A
A
AT-PWR 25 0
D C
O U
T F A U
L T
1 0
0
­2 4
0 V
AC~
5 A
M
A
X
AT-PWR250 Module AT-PWR800 Module
AT-PWR1200 Module
A
A
AT-PWR 800
D C
O U
T F A
U L T
Figure 40. Installing a Power Supply Module
Do not connect the power cord to the module until after you have installed the module in the chassis. The unit is not hot-swappable and may be damaged if it is installed while it is powered on.
100-240
VAC
~12A MAX
2149
62
Page 63
AT-RPS3000 Redundant Power Supply Installation Guide
B
B
1
2
3
4
S
Y
S
T
E
M
P o
E
+ /
S
YS
T
E
M
P
o
E
+
/
S
Y
S
T
E M
S
Y
S
T
E
M
MODULE B
MODULE A
A
A
AT-PWR800
D
C O
U
T F A
U
L
T
DC O
UT
FAU
LT
2153
1 0
0
­2 4
0 V
A
C
~
1
2 A
M
A
X
100-240 VAC
~12
A MAX
3. Secure the module to the chassis by tightening the two captive screws.
A
D
100-240
C
AT-PW R800
A
O
U T
VAC
~12A
F A
U
MAX
L
T
B
1
2
SYSTEM
B
PoE+ /
SYSTEM
MODULE A
PoE+ /
MODULE B
3
SYSTEM
4
SYSTEM
2176
Figure 41. Securing a Power Supply Module
4. For the AT-PWR250 or AT-PWR800 Module, install the power cord retaining clip on the AC power socket by pressing the sides of the clip inward and inserting the two ends into the holes on the power socket. (The AT-PWR1200 Module does not come with a power cord retaining clip.)
Figure 42. Installing a Power Cord Retaining Clip
5. To install a second power supply module, repeat steps 2 through 4.
63
Page 64
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
6. If the unit is to have only one power supply module, cover the empty slot with one of the slot covers, labelled AT-PNL250 and AT-PNL800/ 1200, provided with the unit, as shown in Figure 43 on page 64.
The faceplates of the power supply modules and slot covers are keyed so that the slot cover has to correspond to the power supply module you installed in the unit. Use the AT-PNL250 Blank Panel if the chassis has either of the AT-PWR250 Power Supply Modules, or the AT-PNL800/1200 Blank Panel if the chassis contains the AT-PWR800 or AT-PWR1200 Power Supply Module.
A
D
100-240
C
O
AT-PWR800
A
U T
VAC
~12A
F A
U
MAX
L
T
B
1
2
S
Y
S
T
E
M
P o
MODULE B
3
S
Y
S
T
E
M
4
E
+
/
S
Y
S
T
E M
P
o E
+
/
S
Y
S
T
E
M
MODULE A
AT-PNL800/
1200
B
2150
Figure 43. Installing the Slot Cover
7. Secure the slot cover to the chassis by tightening the two captive screws.
A
100-240
D C
O
AT-PWR800
A
U T
VAC
~12A MAX
F A
U L
T
AT-
PNL800/1200
64
B
1
2
S
Y
S
T
E
P
MODULE A
M
P
MODULE B
3
S
Y
S
T
E
M
4
o
E
+ /
S
Y
S
T
E
M
o E
+
/ S
Y
S
T
E
M
B
2175
Figure 44. Securing the Slot Cover
Page 65
AT-RPS3000 Redundant Power Supply Installation Guide
Note
Caution
STAC
KING
A
A
AT-PWR800
D
C O
UT
FA
U
LT
POWER SUPPLY
R P
S
R E
A D
Y
RP
S
IN
P U
T
WA
R
N I
N G
T
h i s
u n
i t m
a
y h
a v e
m
o
r
e t
h a
n
o n
e p
o w
e
r
i n
p u
t .
T o
r
e
d u
c e
t h
e
r
i s k
o
f
e
le c
t
r
i c
s
h o c
k ,
d i s c
o
n n
e c
t b
o t h
A / C
a n
d R
P
S i
n p
u t
s
b e f
o
r
e
s
er v
i c i
n g
u
n i t
.
12
V/21
A M
A
X
2132
POWER SUPPLY
RPS REA
D Y
RPS INPUT
W A
R N
IN
G T h is
u
n it ma
y h
a
v e
m
o re
th
an
o
n
e p
o
w
e
r
in
p u
t.
To r
e d
u ce
th
e ris
k o
f
e le
c tric
s
h
o c
k ,
d
is
c o n
n
e c
t b
o t
h
A/C
a
n
d
R
P
S
in
p
u
ts
b e
fo
r
e s
e rv
ic
in g
u n it
.
12V/21A
MAX
POWER SUPPLY
RPS REA
D Y
RPS INPUT
W A
R N
IN
G T h is
u
n i
t ma
y h
a
v e
m
o re
th
an o
n
e p
o
w
e
r
in
p u
t.
To
r
e d
u ce
th
e
r
isk
o
f
e le
c tric
s
h
o c
k ,
d
is
c o n
n
e c
t
b
o th
A
/C
a
n
d
R
P
S
in
p
u
ts
b e
fo
r
e
s
e
r
v ic
in g
u n it
.
12V/21A
MAX
POWER SUPPLY
RPS REA
D Y
RPS INP
UT
W A
R N
IN
G T h is
u
n it ma
y h
a
v e
m
o re
th
an
o
n
e p
o
w
e
r
in
p u
t.
To r
e d
u c
e
th
e
r
is
k o
f
e le
c tric
sh
o c
k ,
d
is
c o n
n
e c
t b
o th
A/C
a
n
d
R
P
S
in
p
u
ts
b e
fo
r
e
s
e rv
ic
ing
u n it
.
12V/21A
MAX
100-240
VAC
~12A
MAX

Connecting the AT-RPS3000 Chassis to the x610 Series Switch

Perform this procedure to connect the AT-RPS3000 Chassis to the x610 Series switch, with the AT-RPS-CBL1.0 cable:
The AT-RPS-CBL1.0 cables must be purchased separately.
1. Connect one end of the RPS cable to the RPS Input connector on the back panel of the switch.
Be sure to connect the RPS cable squarely and evenly on the connector on the switch. Attaching the connector at an angle may cause an electrical short that might damage the device.
Figure 45. Connecting the AT-RPS-CBL1.0 Cable to the x610 Series
Switch
65
Page 66
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Caution
S
T
A
C K
I N
G
AT-PW R800
D C
P
O W
E
R F A
U L
T
1
00
-2 40
VAC
~1
2A MAX
POWER SUPPLY
R P
S
R E
A
D Y
R P
S
I N
P U
T
W
A
R
NIN
G
T
h is
u
n
it may
have
m
o re
t ha
n o
ne
p
ow
er
in
pu
t. To
re
d uc
e
th
e ri
sk
o
f
e
lec
tr
ic
sh
o c
k , d
isc
on
n
e ct
b
oth
A/C
a nd
R
PS
in
puts
b
e fo
r
e s
e rvicin
g
un
it
.
2133
2161
CABLE LED
Port On/Off Button
2. Secure the cable to the switch by tightening the two thumbscrews.
Figure 46. Securing the AT-RPS-CBL1.0 Cable to the Switch
If the AT-RPS3000 Chassis is already operational, perform step 3 to turn off the RPS port before connecting the RPS cable. Otherwise, go to step 4.
Never connect or disconnect an RPS cable from an RPS port on an operational AT-RPS3000 Chassis without first turning off the port. Failure to disable an RPS port may damage the redundant power supply system.
3. On the front panel of the AT-RPS3000 Chassis, examine the CABLE LED that corresponds to the port to which you will connect the cable. If the LED is off, go to the next step. If the LED is green, press the On/ Off button to turn off the port. The LED should turn off.
For example, if you intend to connect the DC RPS cable to port 3 on the AT-RPS3000 Chassis, check the CABLE LED for port 3. If the LED is on, press the port’s On/Off button to disable the port.
66
Figure 47. RPS Port On/Off Buttons and CABLE LEDs
Page 67
AT-RPS3000 Redundant Power Supply Installation Guide
Caution
B
B
1
2
SY
S
TE
M
P
o
E
+
/ S
Y
S
T
E
M
P o
M
M
O
D
U
L
E
A
B
B
1
2
S
Y
S
T
E
M
P
o
E
+
/ S
Y
S
T
E
M
P o
M
M
O
D
U
L
E
A
B
B
1
2
S
Y
S
T
E
M
P
o
E
+
/ S
Y
S
T
E
M
P o
M
M
O
D
U
LE
A
4. Connect the AT-RPS-CBL1.0 cable to the designated RPS port on the back panel of the AT-RPS3000 Chassis.
Be sure to connect the RPS cable squarely and evenly on the connector on the chassis. Attaching the connector at an angle may cause an electrical short that might damage the device.
A
100-240
DC
O
AT-PWR800
A
U T
VAC
~12A
F AU
LT
MAX
100-240 VAC
AT-PWR800
DC O
U
T
~12A
FAU
LT
MAX
B
B
1
2
SYSTEM
P
oE+ /
SYSTEM PoE
MODULE
A
3
SYSTEM
4
+ /
SYSTEM
MODULE B
2145
Figure 48. Connecting the AT-RPS-CBL1.0 Cable to the AT-RPS3000
Chassis
67
Page 68
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
5. Secure the cable to the port by tightening the two thumbscrews.
A
D
10
C
0-24
O
AT-PWR800
A
U T
0
VA
C ~12A
F A
U
MAX
L
T
100-240 VAC
D C
AT-PWR800
O
U T
~12A
F A
MAX
U L
T
B
1
2
B
Figure 49. Securing the AT-RPS-CBL1.0 Cable to the AT-RPS3000
S
Y
S
T
E
M
P
MODULE B
3
S
Y
S
T
E
M
4
o
E
+ /
S
Y
S
T
E
M
P
o E
+
/
S
Y
S
T
E
M
MO
DULE
A
2146
Chassis
6. Repeat this procedure to connect additional x610 Series switches to the AT-RPS3000 Chassis.
68
Page 69

Powering On the Power Supply Modules

B
B
1
2
3
4
SYSTEM
PoE+ /
SYSTEM PoE+ /
SYSTEM
SYSTEM
M
O
D
U
L
E
B
M
O
D
U
L
E
A
A
A
AT-PW R800
DC O
UT
FAULT
AT-PW R800
DC O
UT
FAULT
1 0 0
­2
4 0
V
A C
~
1 2
A
M
A X
2164
1 0
0
-2 4 0
V
A
C
~
1
2 A
M
A X
D
C
O
U
T
F
A
U
L
T
100-240 V
AC~12A M
AX
Perform this procedure to power on the power supply modules in the AT-RPS3000 Chassis:
1. For the AT-PWR250 or AT-PWR800 Module, raise the power cord retaining clip on the power supply module.
AT-RPS3000 Redundant Power Supply Installation Guide
Figure 50. Raising the Power Cord Retaining Clip
2. Connect the AC power cord to the AC socket on the power supply module, as shown in Figure 51 on page 70.
69
Page 70
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
B
B
1
2
3
4
S
Y
S
T E
M
P
o E
+
/ S
Y
S
T
E
M
P
o
E
+
/
S
Y
S
T E
M
S
Y
S
T
E
M
MODULE B
MODULE A
A
A
AT-PWR800
D C
O
U
T F A
U L
T
AT-PWR800
D
C O
U
T F A
U L
T
100-240
VAC
~12A
MAX
2155
100-240
VAC
~12A
MAX
A
A
AT-PWR800
D
C
O
U
T
F
A
U
L
T
100-240 VAC
~
12A MAX
A
1
0 0
D
­2
C
4
O
AT-PWR800
A
0
U
V A
T
C
~
1
F
2
A
A
U
M
L T
A
X
1 0
D
0
C
­2
AT-PWR800
O
4
U
0
T
V
A
C
~
F
1
A
2
U
A
L
M
T
A
X
B
B
Figure 51. Connecting the AC Power Cord
3. For the AT-PWR250 or AT-PWR800 Module, lower the power cord retaining clip to secure the power cord to the unit.
1
2
S
Y
S
T
E
M
P
MODULE B
3
S
Y
S
T
E
M
4
o
E
+
/ S
Y
S
T E
M
P
o
E
+
/
S
Y
S
T
E
M
MODU
LE
A
2134
4. Connect the other end of the power cord to an appropriate power source. Refer to Appendix A, “Technical Specifications” on page 87 for
Figure 52. Lowering the Power Cord Retaining Clip
the power specifications of the power supply modules.
70
Page 71
AT-RPS3000 Redundant Power Supply Installation Guide
D C
O
U
T
F
A
U
L
T
1
0
0
-2 4 0
V
A
C
~
1 2
A M
A
X
5. Examine the DC OUT/FAULT LED on the power supply module. The module is operating normally if the LED is green. If the LED is amber or off, refer to Chapter 4, “Troubleshooting” on page 83 for troubleshooting suggestions.
A
DC OUT
AT-PWR800
A
100-240
VAC
~12A
FAULT
MAX
DC OUT
AT-PWR800
100-240 VAC
~12A
FAULT
MAX
B
1
2
SYSTEM
B
PoE+ /
SYSTEM PoE+ /
M
O
D
U
L E
A
3
SYSTEM
4
SYSTEM
M
O
D
U
L
E
B
2147
Figure 53. Lowering the Power Cord Retaining Clip
6. In the POWER MODULE STATUS section of the LED panel shown in Figure 54 on page 72, examine the FAN and DC OUT LEDs of the power supply module you just powered on. Both LEDs should be green. If the LEDs are amber or off, refer to Chapter 4, “Troubleshooting” on page 83 for troubleshooting suggestions.
71
Page 72
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
Figure 54. Checking the FAN and DC OUT LEDs in the LED Panel
7. In the MODULE A/B PORTS section of the LED panel shown in Figure 55 on page 73, examine the LOAD and CABLE LEDs of the two ports that receive power from the power supply module. The LOAD and CABLE LEDs of RPS ports that are connected to x610 Series switches should be green. If the LEDs are off, press the On/Off buttons to active the ports.
72
Page 73
AT-RPS3000 Redundant Power Supply Installation Guide
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PW R800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PW R800
DC OUT
FAULT
100-240 VAC~12A MAX
2156
B
B
1
2
3
4
SYSTEM
PoE+ / SYSTEM PoE+ / SYSTEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
DC OUT
FAULT
100-240 VAC~12A MAX
AT-PWR800
DC OUT
FAULT
2157
100-240 VAC~12A MAX
Figure 55. Checking the LOAD and CABLE LEDs in the LED Panel
73
Page 74
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules
Warning
8. If the chassis has two power supply modules, repeat this procedure to power on the second module.
This unit might have more than one power source. To reduce the risk of electric shock, disconnect all power cords before servicing the unit. E30
This completes the installation procedure for the AT-RPS3000 Redundant Power Supply.
74
Page 75

Chapter 3

Removing Power Supply Modules

Here are the procedures for removing power supply modules from the AT-RPS3000 Chassis:
“Removing the AT-RPS-CBL1.0 Cable” on page 76
“Removing an AC Power Supply Module” on page 78
75
Page 76
Chapter 3: Removing Power Supply Modules
Caution
B
B
1
2
SYSTEM
PoE+ /
SY
STEM
PoE+ /
SY
STEM
SYSTEM
MODULE B
MODULE A
AT-PWR800
DC OUT
FAULT
2211
1
0 0
-2 4
0
V
A
C
~
1
2
A
M
A
X

Removing the AT-RPS-CBL1.0 Cable

Here are the steps to removing the AT-RPS-CBL1.0 cable from an RPS port on the AT-RPS3000 Chassis and switch:
1. On the front panel of the AT-RPS3000 Chassis, examine the CABLE LED of the RPS port to which the AT-RPS-CBL1.0 cable is connected. If the LED is off, go to the next step. If the LED is green, press the On/ Off button to turn off the port. The LED should turn off.
For example, if you want to disconnect the cable from RPS port 3 on the AT-RPS3000 Chassis, check the CABLE LED for port 3. If the LED is on, press the port’s On/Off button to disable the port.
Never connect or disconnect an RPS cable from an RPS port on an operational AT-RPS3000 Chassis without first turning off the port. Failure to disable an RPS port may damage the redundant power supply system.
2. Loosen the two thumbscrews that secure the cable to the RPS port on the AT-RPS3000 Chassis.
Figure 56. Loosening the Thumbscrews that Secure the AT-RPS-CBL1.0
Cable to the AT-RPS3000 Chassis
76
Page 77
AT-RPS3000 Redundant Power Supply Installation Guide
Caution
Caution
B
B
1
2
SYSTEM
PoE+ /
SYSTEM Po
M
M
O
D
U
L
E
A
B
B
1
2
SYSTEM
PoE+ /
SYSTEM Po
M
M
O
D
U
L
E
A
B
B
1
2
SYSTEM
PoE+ /
SYSTEM Po
M
M
O
D
U
L
E
A
3. Remove the cable from the RPS port.
Be sure to remove the RPS cable squarely and evenly from the connector on the chassis. Removing the connector at an angle may cause an electrical short that might damage the device.
D
100
C OUT
AT-PWR800
-240 VAC
~
12A
FAULT
MAX
DC OUT
AT-PWR800
100-240 VAC
~12A
FA
ULT
MAX
B
1
2
SYSTEM
B
PoE+ /
SYSTEM PoE+ /
M
O
D U
L E
A
3
SYSTEM
4
SYSTEM
M
O
D
U
LE
B
2211
Figure 57. Removing the AT-RPS-CBL1.0 Cable from the AT-RPS3000
Chassis
4. Loosen the two thumbscrews that secure the cable to the RPS port on the x610 Series switch.
5. Remove the cable from the RPS port on the switch.
Be sure to remove the RPS cable squarely and evenly from the connector on the switch. Removing the connector at an angle may cause an electrical short that might damage the device.
77
Page 78
Chapter 3: Removing Power Supply Modules
B
B
1
2
3
4
SYSTEM
PoE+ /
SYSTEM PoE+ / SYSTEM
SYSTEM
M
O
D
U
L
E
B
M
O
D
U
L
E
A
A
A
AT-PWR800
D C
O
U
T F A
U L
T
AT-PWR800
D
C O
U
T F A
U L
T
100-240 VAC
~12A MAX
2169
100-240 VAC
~12A
MAX
A
A
AT-PWR800
DC
OUT
FAU
LT
100-240 VAC
~12A MAX

Removing an AC Power Supply Module

To remove an AC power supply module from the chassis, perform this procedure:
1. For the AT-PWR250 or AT-PWR800 Module, raise the power cord retaining clip on the power supply module.
Figure 58. Raising the Power Cord Retaining Clip
78
Page 79
AT-RPS3000 Redundant Power Supply Installation Guide
Caution
B
B
1
2
3
4
S
Y
S
T
E
M
P o
E
+ /
S
Y
S
T
E
M
P
o E
+ /
S
Y
S
T
E
M
S
Y
S
T
E
M
MODULE B
MODULE A
A
A
AT-PWR800
D
C
O U
T F A
U
L T
AT-PWR800
D
C O
U
T F A
U
L T
100
-240 VAC ~12A
M AX
2170
100-240
VA
C ~12A
MAX
A
A
2188
AT-PWR800
D C
O
U
T F A
U
L T
AT-PWR800
D C
O U
T
F
A U
L T
2. Disconnect the power cord from the power supply module.
Figure 59. Removing the Power Cord
The power module is not hot-swappable. It may be damaged if you remove it from the chassis while it is powered on. If the chassis has two power modules, you do not have to power off the second module, unless you are planning to remove it.
10
0-2
4 0 V
A
C
~
1
2A
M
A
100-240
V
AC
~12
A
M AX
X
79
Page 80
Chapter 3: Removing Power Supply Modules
Note
B
B
1
2
3
4
SYST
EM
PoE+ /
SY
STEM
PoE+ /
S
Y
STEM
SYSTEM
MODULE B
MODULE A
A
A
AT-PWR800
D
C OUT
FAU
LT
1
0 0-
24
0 V
A C
~
12
A
M
A X
AT-PWR800
DC
OU
T
FA
ULT
2172
10
0-
24
0 V
A C
~
12
A M
A
X
3. Loosen the two captive screws securing the power module to the
A
DC
1
O
AT-PWR800
A
0
0
UT
-2 4
0 V
A
C
FA
~
1
ULT
2 A
M
A
X
chassis.
AT-PWR800
D C OUT
10
0
-2 4
0
V A
C ~1
FA
2
A
ULT
M A
X
B
1
2
SYSTEM
B
PoE+ /
SY
ST
EM
MODULE A
3
SYSTEM
4
Po
E + /
SY
STE
M
MODULE B
2171
Figure 60. Loosening the Two Captive Screws
4. Slide the module from the chassis.
Figure 61. Removing the Power Supply from the Chassis
Use care when pulling the power supply module from the chassis. You might bend the power and control pins on the backplane connectors if you roughly pull the module from the unit.
80
5. To install a new power supply module, perform the procedure “Installing a Power Supply Module” on page 61.
Page 81
AT-PNL800/
B
B
1
2
3
4
SYSTEM
PoE+ /
SY
S
TEM
PoE+ /
SY
STEM
SYSTEM
MODULE B
MODULE A
A
A
A
T
-
P
N
L
8
0
0
/
1
2
0
0
AT-PWR800
DC OU
T
FAULT
2174
1
0
0
-2 4 0
V A
C
~
1 2 A
M
A X
AT-RPS3000 Redundant Power Supply Installation Guide
6. If you are not replacing the module, cover the empty slot with one of the slot covers, labeled AT-PNL250 and AT-PNL800/1200, provided with the unit.
The faceplates of the power supply modules and the slot covers are keyed so that the slot cover has to correspond to the power supply module you installed in the unit. Use the AT-PNL250 Blank Panel if the chassis contains the AT-PWR250 Power Supply Module, or the AT-PNL800/1200 Blank Panel if it has the AT-PWR800 or AT-PWR1200 Power Supply Module.
A
A
D
100-240 VAC
C
O
1200
AT-PWR800
U
T
~12A
F A
U
MAX
L T
B
1
2
S
Y
S
T
E
P o
MODULE A
M
E
+
/
S
Y
S
T
E
M
3
S
Y
S
T
E
M
4
P
o E
+
/ S
Y
S
T E
M
M
ODULE
B
2173
B
Figure 62. Installing the Slot Cover
7. Secure the slot cover to the chassis by tightening the two captive screws.
Figure 63. Securing the Slot Cover
81
Page 82
Chapter 3: Removing Power Supply Modules
82
Page 83

Chapter 4

Troubleshooting

If you encounter a problem with the product, you may be able to resolve it with the information in this chapter:
Problem 1: A power supply module does not seem to be receiving power because its DC OUT/FAULT LED on its faceplate is off, as well as its FAN and DC OUT LEDs in the LED panel.
Solution: Try the following:
Verify that the module is fully seated in the power supply slot in the
chassis.
Verify that the power cord is firmly connected to the power supply
module and the power source.
Try connecting the power module to another power source, preferably
located on a different circuit.
Verify that the power source is operating properly by plugging a
different device into it.
Try replacing the power cord.
Verify that the power from the power source meets the operating
specifications of the power supply module, listed in “Power Specifications” on page 88.
Replace the power supply module.
Problem 2: The LOAD and CABLE LEDs for an RPS port are off, but the module’s FAN and DC OUT LEDs in the LED panel are on, indicating that the module is receiving power.
Solution: The RPS port may have been turned off. Try pressing the port’s On/Off button.
Problem 3: The DC OUT/FAULT LED on the faceplate of the power supply module and the DC OUT LED in the LED panel are amber.
Solution: The power supply module is failing or the power from the power source is not in the range of the operating specifications of the module. Try the following:
Try connecting the power module to another power source, preferably
located on a different circuit.
83
Page 84
Chapter 4: Troubleshooting
Verify that the power from the power source is within the operating
specifications of the power supply module, listed in “Power Specifications” on page 88.
Replace the power supply module.
Problem 4: The FAN LED in the LED panel is amber.
Solution: A fan in the power supply module has failed. Replace the
module.
Problem 5: One or both power supply modules shutdown.
Solution: Try the following:
Check to be sure that the chassis is not overheating. Verify that it has
adequate ventilation and that the fans on the power supply modules and the ventilation vents on the front panel of the chassis are unobstructed.
Verify that the module is not connected to two high-power x610
Switches or one low-power and one high-power switch. It may have shutdown because the power requirements of the switches exceeded its power reserves. A power supply module can support two low-power switches or one high-power switch at a time.
Problem 6: You are unable to install a second module in the chassis because the faceplates of the new and existing modules do not align.
Solution: The faceplates of the power supply modules are keyed to prevent the installation of incompatible modules in the chassis. You may not install the AT-PWR250 Power Supply Module in the same chassis as the AT-PWR800 or AT-PWR1200 Module. For more information, refer to “Power Supply Modules” on page 19.
Problem 7: The chassis is not providing PoE+ power to an PoE+ x610 Series switch.
Solution: Try the following:
Verify that the x610 Series switch supports the PoE+ feature. The
model name on the front panel of the switch should contain the letters “POE+.” Switches whose model names do not include the letters do not support PoE+.
Verify that the AT-RPS-CBL1.0 cable from the x610 Series switch is
securely connected to RPS port 2 or 4, PoE+/System, on the chassis.
Verify that the chassis has a power supply for the RPS port to which
the switch is connected. For example, if the switch is connected to RPS port 4, slot B of the chassis has to contain either an AT-PWR800 or AT-PWR1200 Module.
84
Page 85
AT-RPS3000 Redundant Power Supply Installation Guide
Verify that the power supply module that is suppose to be delivering
the PoE+ power from the chassis is either the AT-PWR800 or AT-PWR1200 Module. The AT-PWR250 Module do not support PoE+ power.
Check the FAN LED for the power supply module, in the LED panel. If
the LED is amber, one or both fans in the module are not functioning properly. If this occurs, the module continues to provide system power on both of its RPS ports, but stops providing PoE+ power on the RPS PoE+/System port.
Check the TEMP LED in the LED panel. If the LED is amber, the power
module may be overheating. When this occurs, the module continues to provide system power on both of its RPS ports, but stops providing PoE+ power on the RPS PoE+/System port.
85
Page 86
Chapter 4: Troubleshooting
86
Page 87

Appendix A

Technical Specifications

Physical Specifications

Dimensions (H x W x D):
AT-RPS3000 Chassis 4.4 cm x 44.1 cm x 36.3 cm
AT-PWR250 and 4.2 cm x 14.8 cm x 25,2 cm AT-PWR800 Power Supply (1.7 in. x 5.8 in. x 9.8 in.) Modules
AT-PWR1200 Power Supply 4.2 cm x 14.8 cm x 30.7 cm Module (1.7 in. x 5.8 in. x 12.1 in.)
(1.7 in. x 17.4 in. x 14.3 in.)
Weight:
AT-RPS3000 Chassis 4.2 kg (9.3 lb.) AT-PWR250 Module (AC) 1.5 kg (3.3 lb.) AT-PWR800 Module 1.8 kg (3.9 lb.) AT-PWR1200 Module 2.2 kg (4.8 lb.)
Recommended Minimum
Ventilation on All Sides: 10 cm (4.0 in)

Environmental Specifications

Operating Temperature: 0° C to 40° C (32° F to 104° F)
Storage Temperature: -20° C to 60° C (-4° F to 140° F)
Operating Humidity: 5% to 90% noncondensing
Storage Humidity: 5% to 95% noncondensing
Maximum Operating Altitude: 3,048 m (10,000 ft)
Maximum Nonoperating Altitude: 4,000 m (13,100 ft)
87
Page 88
Appendix A: Technical Specifications

Power Specifications

Maximum Power Consumption:
Input Voltage:

Certifications

EMI (Emissions): FCC Class A, EN55022 Class A,
AT-PWR250 Module (AC) 250 watts AT-PWR800 Module (AC) 800 watts AT-PWR1200 Module (AC) 1200 watts
AT-PWR250 Module (AC) 100-240 VAC, 5 A maximum, 50/60 Hz AT-PWR800 Module (AC) 100-240 VAC, 12 A maximum, 50/60 Hz AT-PWR1200 Module (AC) 100-240 VAC, 16 A maximum, 50/60 Hz
EN61000-3-2, EN61000-3-3, VCCI Class A, CISPR Class A, C-TICK, CE
EMC (Immunity): EN55024
Electrical and Laser Safety: EN60950-1 (TUV), UL 60950-1 (
EN60825
Quality and Reliability (MTBF):
AT-RPS3000 Chassis 440,000 hrs. AT-PWR250 Module (AC) 100,000 hrs. AT-PWR800 Module (AC) 100,000 hrs. AT-PWR1200 Module (AC) 80,000 hrs.
Compliance Marks: CE,
CULUS
, TUV, C-Tick
CULUS
)
88
Page 89

Port Pin-outs

P1P2P3P4
19
1017
AT-RPS3000 Redundant Power Supply Installation Guide
Figure 64 identifies the pins on the RPS ports.
Figure 64. Port Pin-outs for the RSP System and PoE+/System Ports
Table 11 lists the pin signals for the RPS 1 and 3 System ports.
Table 11. RPS 1 and 3 System Ports
Pin Description
P1 Ground (12V return)
P2 +12V
P3 Reserved
P4 Reserved
1 +12V remote sense
2Reserved
3 RPS status
4Reserved
5 -12V remote sense
6 RPS power good
7Reserved
8Reserved
9Reserved
10 RPS present
11 Switch power good
12 Reserved
89
Page 90
Appendix A: Technical Specifications
Table 11. RPS 1 and 3 System Ports
Pin Description
13 Reserved
14 Reserved
15 Switch present
16 Reserved
17 Reserved
Table 12 lists the pin signals for the RPS 2 and 4 PoE+/System ports.
Table 12. RPS 2 and 4 PoE+/System Ports
Pin Description
P1 -12V return
P2 +12V
P3 +56V
P4 56V return
1 +12V remote sense
2 Reserved
3 RPS status
4 Reserved
5 -12V remote sense
6 RPS power good
7 Reserved
8 56V load share
9 PoE+ positive remote sense
10 RPS present
11 Switch power good
90
12 Reserved
13 PoE+ ready
14 Reserved
15 Switch present
16 Reserved
Page 91
AT-RPS3000 Redundant Power Supply Installation Guide
Table 12. RPS 2 and 4 PoE+/System Ports
Pin Description
17 PoE+ negative remote sense
91
Page 92
Appendix A: Technical Specifications
92