Allied Telesis AT-PB200 User Manual

Technical Specifications
Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F) Maximum Storage Temperature: -20° C to 80° C (-4° F to 176° F) Operating Altitude: Up to 3,048 meters (10,000 feet) Humidity: 5% to 80% (non-condensing) EMC: FCC Class A, EN55022 Class A, EN55024 Safety: EN60825, EN60950, UL1950 (UL/cUL)
AT-PB200 Series
Fast Ethernet Switches
Electrical Safety and Emission Statement
U.S. Federal Com mun ications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful inte rference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
RFI Emission EN55022 Class A Warning: In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Immunity EN55024 Electrical Safety EN60950, UL1950 (UL/cUL) Laser EN60825
Copyright 2002 Allied Telesyn, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn, Inc.
Allied Telesyn, Inc. 960 Stewart Drive, Suite B Sunnyvale, CA 94085 USA
Tel 1 (408) 730-0950 • Fax 1 (408) 736-0100
Visit our web site at: www.alliedtelesyn.com
4 PN 613-50148-00 Rev C 020626
Overview
The AT-PB200 Series Fast Ethernet Switches are hot swappable modules for the PowerBlade Chassis. The AT-PB200 Series Switches are designed to interconnect LAN devices and subnetworks over large distances into an integrated network. These dual­port switches can also be used to improve the performance of your network by dividing it into smaller, more manageable segments. Each switch features a 10/100Base-TX twisted pair port and an 100Base-FX fiber optic port. The twisted pair port has an RJ-45 connector and a maximum operating distance of 100 meters (328 feet). The fiber optic port has a FJ, SC, ST, LC, MT-RJ, or VF-45 connector and a maximum operating distance of 2 kilometers (1.2 miles) to 100 kilometers (62 miles), depending on the model.
Related Documents
This quick install guide is an abbreviated version of the installation procedures. For complete details on the features and functions of the Ethern et s witch es and additio nal installation instructions, refer to the PowerBlade Chassis Installation Guide. This guide is available from the Allied Telesyn web site at www.alliedtelesyn.com.
Cable Specifications
The following table lists the maximum operating distances for the AT-PB200 Series Switches.
Model
AT-PB201 RJ-45 100 m (328 ft) ST AT-PB202 RJ-45 100 m (328 ft) SC 2 km (1.2 mi) AT-PB202/1 RJ-45 100 m (328 ft) SC 15 km (9. 3 m i ) AT-PB202/2 RJ-45 100 m (328 ft) SC 40 km (24.8 mi) AT-PB202/3 RJ-45 100 m (328 ft) SC 70 km (43.4 mi) AT-PB202/4 RJ-45 100 m (328 ft) SC 100 km (62 mi) AT-PB204 RJ-45 100 m (328 ft) MT-RJ 2 km (1.2 mi)
Quick Install Guide
For use in the PowerBlade Chassis
10/100Base-TX 100Base-FX
1
Connector Maximum Distance
Connector Maximum Distance
2
2 km (1.2 mi)
Model
Connector Maximum Distance
1
Connector Maximum Distance
2
AT-PB205 RJ-45 100 m (328 ft) VF-45 2 km (1.2 mi) AT-PB206 RJ-45 100 m (328 ft) LC 2 km (1.2 mi) AT-PB207 RJ-45 100 m (328 ft) FJ 2 km (1.2 mi)
10/100Base-TX 100Base-FX
1. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA 568A Commercial Building Telecommunications Cabling Standard.
2. Maximum distance for 100 Mbps Optical Datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at the operating optical wavelength.
The following table lists the cable specifications for the 100Base-FX fiber optic port when operating in full-duplex mode.
Model Cable Maximum Distance
AT-PB201 AT-PB202
50/125 or 62.5/125 micron multimode
2 km (1.2 mi) 13 dB at 1310 nm
Maximum Allowable Loss Budget
AT-PB204 AT-PB205 AT-PB206 AT-PB207
AT-PB202/1 50/125 or 62.5/125 multimode 2 km (1.2 mi) 13 dB at 1310 nm
9/125 micron single-mode 15 km (9.3 mi) 16 dB at 1310 nm AT-PB202/2 9/125 micron single-mode 40 km (24.8 mi) 30 dB at 1310 nm AT-PB202/3 9/125 micron single-mode 70 km (43.4 mi) 37 dB at 1310 nm AT-PB202/4 9/125 micron single-mode 100 km (62 mi) 37 dB at 1310 nm
The following table lists the cabling specifications for the 10/100Base-TX twisted pair port when operating in full-duplex mode.
Operating Mode Cable Maximum Distance
10Base-T Shielded or unshielded Category 3 or better 100 m (328 ft) 100Base-TX Shielded or unshielde d Category 5 or better 100 m (328 ft)
Cable specifications for half-duplex operation and fiber optic port specifications can be found in the PowerBlade Chassis Installation Guide.
Package Contents
Make sure the following items are included in your package. If any item is missing or damaged, contact your Allied Telesyn sales representative for assistance.
One AT-PB200 Series Switch Module This quick install guide Warranty card
Installing a Switch
1. Remove a blank faceplate from an empty expansion slot on the front of the chassis. The module can be installed in any slot.
2. Remove the module from the shipping package and store the packaging material in a safe place. Be sure to observe standard ESD precautions.
3. Check the setting of the J6 jumper. If the chassis does not contain an AT-PBM02 management module, set the jumper to the Enabled (RIGHT) position. Refer to the PowerBlade Chassis Installat ion Guid e for the jumper location.
4. For the twisted pair port, set the AUTO NEG switch to either ON or OFF to enable or disable the auto-negotiation on the port. Refer to the PowerBlade Chassis Installation Guide for the location of the Auto-negotiation switch.
5. Set the DIP switches to the appropriate settings. Refer to the PowerBlade Chassis Installation Guide for possible DIP switch settings.
6. Slide the module into the expansion slot, aligning it with the guiderails until it firmly connects to the chassis’ backplane.
7. Secure the module to the chassis by tightening the thumbscrew.
8. Verify that the PR LED on the switch is green. If the LED is OFF, refer to the PowerBlade Chassis Installat ion Guid e for troubleshooting instructions.
9. Remove the dust cover from the fiber optic port and connect the fiber optic cable to the 100Base-FX port. Verify that the module’s transmitter port (TX) is connected to the end-node’s receiver port (RX) and that the module’s receiver port (RX) is connected to the end-node’s transmitter port (TX).
10. Connect the twisted pair cable to the 10/100Base-TX twisted pair port.
11. Set the MDI/MDI-X button to the appropriate setting. Refer to the PowerBlade Chassis Installation Guide for additional information on the MDI/MDI-X button.
12. Power ON the end-nodes.
13. Check that the LK/AT LED for both ports on the module are green. If the LEDs are OFF, refer to PowerBlade Chassis Installation Guide for troubleshooting instructions.
14. The module is now ready for use. Repeat this procedure to install additional AT-PB200 Series modules.
Refer to the PowerBlade Chassis Installa tio n G ui de for additional information .
Status LEDs
LED Color Description
PR Green Power is applied to the switch. LK/AT Green
Blinking
100M Green
OFF
FD Green
OFF
AUTO Green The 10/100Base-TX port is auto-negotiating.
A link has been established on the port. Data is being transmi tt ed or received on the port. The port is operating at 100 Mbps. The port is operating at 10 Mbps. The switch is operating in ful l- duplex mode. The switch is operating in half-duplex mode.
2 3