Technical Specifications
Maximum Operating Temperature: 0° C to 40° C (32° F to 104° F)
Maximum Storage Temperature: -20° C to 80° C (-4° F to 176° F)
Operating Altitude: Up to 3,048 meters (10,000 feet)
Humidity: 5% to 80% (non-condensing)
EMC: FCC Class A, EN55022 Class A,
EN55024
Safety: EN60825, EN60950, UL 1950 (UL/cUL)
AT-PB10 Series
Fast Ethernet Media Converters
Electrical Safety and Emission Statement
Standards: This product meets the following standards.
U.S. Federal Communicati ons Comm ission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to
operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du
Canada.
RFI Emission EN55022 Class A
Warning: In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
Immunity EN55024
Electrical Safety EN60950, UL 1950
Laser EN60825
Copyright 2001 Allied Telesyn International Corp.
All rights reserved. No part of this publication may be reproduced without prior written permission
from Allied Telesyn International Corp.
Quick Install Guide
For use with the PowerBlade Chassis
Overview
The AT-PB10 Series Fast Ethernet Media Converters are hot swappable
modules designed for the PowerBlade Chassis. These media converters extend
the distance of your network by interconnecting twisted pair cabling and fiber
optic cabling or twisted pair cabling and thinnet cabling. Each media
converter (except for the AT-PB15) features a 10Base-T twisted pair port and
a 10Base-F fiber optic port. The twisted pair port has an RJ-45 connector and
a maximum operating distance of 100 meters (328 feet). The fiber optic port
has an ST or SC connector and a maximum operating distance of 2 kilometers
(1.2 miles). These units operate at 10 Mbps and feature full-duplex operation.
The AT-PB15 features a 10Base-T twisted pair port and a 10Base2 thinnet
port. The twisted pair port has an RJ-45 connector and a maximum operating
distance of 100 meters (328 feet). The thinnet port has a BNC-type connector
and a maximum operating distance of 185 meters (606 feet). The AT-PB15
operates at 10 Mbps and features half-duplex operation only.
Related Documents
This quick install guide is an abbreviated version of the installation
procedure. For complete details on the features, functions and installation
instructions, refer to the PowerBlade Chassis Installation Guide. This guide is
available from Allied Telesyn’s web site at www.alliedtelesyn.com.
Allied Telesyn International Corp.
960 Stewart Drive, Suite B
Tel 1 (408) 730-0950 • Fax 1 (408) 736-0100 • Web site: www.alliedtelesyn.co
Sunnyvale, CA 94085 USA
4 PN 613-50146-00 Rev B 011030
e
Cable Specifications
The following table lists the cable specifications for the 10Base-T twisted pair
port on all AT-PB10 series modules.
Connector Type of Twisted Pa ir Cable
RJ-45 Unshielded/Shielded Twisted Pair Category 3 or
better
The second port on the AT-PB15 has a BNC connector with a maximum
operating distance of 185 meters (606 feet). The following table lists the cable
specifications for the 10Base-F fiber optic port on the AT-PB13 and AT-PB14
when operating in full-duplex mode.
Model Connector Type of Fiber Optic Cable
AT-PB13 ST 50/125 µm or 62.5/125 µm multimode 2 km (1.2 mi)
AT-PB14 SC 50/125 µm or 62.5/125 µm multimode 2 km (1.2 mi)
Cable specifications for half-duplex operation can be found in the PowerBlade
Chassis Installation Guide.
Maximum
Operating Distance
100 m (328 ft)
Maximum
Operating Distance
Package Contents
Make sure the following items are included in your package. If any item is
missing or damaged, contact your Allied Telesyn sales representative for
assistance.
❑ One AT-PB10 Series Media Converter Module
❑ This quick install guide
❑ Warranty card
5. Secure the module to the chassis by tightening the thumbscrew.
6. Verify that the PR LED on the front of the unit is green.
7. Set the LT/ML switch to the ML (MissingLink) position (AT-PB13 or
AT-PB14 only).
8. Set the MDI/MDI-X switch for the 10Base-T port to the appropriate
setting.
9. Connect the data cables.
10. The AT-PB10 series module is now ready for use. Repeat this procedure to
install additional AT-PB10 series modules.
Refer to the PowerBlade Chassis Installation Guide for additional
information.
Status LEDs
LED Color Description
System LEDs
PR Green Power is applied to the media converter.
ML Green
OFF
Port LEDs
LK Green A link is established on the port.
RX Green Data is being received or transmitted by the port.
The MissingLink feature is activated.
The MissingLink f eature is disabled and t he unit is
performing a link test.
Fiber Optic Interface (Multimode)
Installing the Media Converter
1. Remove a blank faceplate from an empty expansion slot on the front of the
chassis. The module can be installed in any expansion slot.
2. Remove the module from the shipping package and store the packaging
material in a safe place. Be sure to observe standard ESD precautions.
3. For an AT-PB15 module, check the setting of the J5 jumper. If the chassis
does not contain an AT-PBM02 management module, set the jumper to the
disabled position. Refer to the PowerBlade Chassis Installation Guide for
the jumper location.
4. Slide the module into the expansion slot, aligning it with the guiderails
until it firmly connects to the chassis’ backplane.
2 3
Receiver Typical Range
Sensitivity -30 dBm N/A
Saturation 170 µW (-7.6 dBm) 150 µW (-8.2 dBm)
Transmitter
Wavelength 830 nm ±
Output Power Typical Worst
62.5/125 mM -12 dBm -15.0
50/125 mM -16.5 dBm -19.5 dBm
20 nm