Ag Leader PFadvantage Shaft Speed Sensor User Manual

PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Shaft Speed Sensor and Sprocket on planter – April 2003
p
p
p
p
p
b
f
p
p
p
p
FIELD
[Create or change field and name field functions. Active configuration for field displayed.]
VIEW
CONFIG
[Set active configuration and active tgt prescription file.]
ACTIVE ON/OFF
[Select and accept new tgt
rescription file.]
EDIT
TGT FILE
VIEW
INFO
[Create or change load and name load functions.]
Menu Key
FIELD LOAD
CAL SETUP
Press Menu Key to switch between Main Menu keys
LOAD
Press at
guidance reference
SHOW MAP
[Splits screen and shows On Screen Map on left side. Press HIDE MAP key to return to full screen. ]
SET A
eginning o
ass.
SET B
Press at end of guidance reference
ass. When
using curve
attern, ress at end
of every
ass.
DIAG
RESET
Press to reset guidance and area
oints to start a new field.
OPTIONS SHOW MAP
PAUSE
Press to
ause guidance when filling applicator. Drive back to swath and
ress RESUME key.
LIGHTBARMARKS
NAVIGATE
ADD/STRT
Used for Headlands. See Lightbar Manual.
BOUNDARY
CLR/STOP
Used for Headlands. See Lightbar Manual.
GRID
AREA PT
Press at every corner of field to calculate field area. Must have “Field Area” displayed on main screen to see area.
[Screen displays field, product, units/ac and default rate stored in tgt file.]
Revision 3 1 of 3 P.N. 2002831-22
PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Shaft Speed Sensor and Sprocket on planter – April 2003
p
N
N
g
Menu Key
FIELD LOAD
OPTIONS SHOW MAP
CAL
AREA
DISTANCE
[Radar calibration screen]
[Screen Displays all product/controller configurations]
EDIT
SETTINGS
CREATE
NEW
Settings Controller Make Controller Model Product Units Ground Speed Source App Distance From GPS Full Swath Tgt Units:Contrler Units Target Rate Increment Actual Rate Scale Factor
ADVANCED
SETTINGS
CONTRLER
SETTINGS
APP RATE
CONFIG
DELETE
CAL SETUP
Press Menu Key to switch between Main Menu keys
MARKS
CARD
LOAD
Settings Logging device Logging interval Log file
[To erase files,
ress SHOW ALL FILES key, select file, press FILE OPTIONS key and press ERASE FILE key.]
SETUP
CONSOLE
Settings Operating mode Units of Measure Month/Day/Year Time Serial number Box cal Voltage cal GPS check sum Field marker input Display brightness
DIAG
MEMORY
[Clear data in loads or erase all fields functions]
Selections
MEA MESSAGE GPS/PORT CONFIGURATION BEACON DIFFERENTIAL SATELLITE DIFFERENTIAL LIGHTBAR GUIDANCE
Guidance Screen Settings Pattern Headland Type Look-Ahead Display Mode Swath Direction Swath Width Antenna Offset Pass Skips Units Displayed Contour Log Interval
GPS
MAP
DIAG
SYSTEM
SENSORS
GPS
RAW
NMEA
Satellite Differential Screen Settings Differential source = BEACON or WAAS or SATELLITE Differential provider Satellite frequency Satellite baud rate Provider user code Omnistar code Subscription expiration Age of differential
Settings Target rate outside field Controller time delay Actual rate units
actual rate
Lo
Settings Flowmeter pulses/10 revs
umber seeds/rev
Area count
Revision 3 2 of 3 P.N. 2002831-22
PF3000 and PF3000 Pro – Quick Reference Setup Instructions for Shaft Speed Sensor and Sprocket on planter – April 2003
Note: These instructions pertain to PF firmware versions 4.00 or higher.
Settings for Shaft Speed Sensor and Sprocket on planter

1. Press SETUP key. Press APP RATE CONFIG key. Press CREATE NEW key. Set the following:

Controller Make: Set to FLOWMETER. Controller Model: Set to PLANTING. Product: Press EDIT key. You can select an existing product and press
ACCEPT key or create a new product by pressing CREATE NEW key. Press EDIT NAME key and enter name of product. Use Left or Right Arrow keys to select a character. Use Up or Down Arrow key to change the character. Set every character and press ACCEPT key twice.
Units: Set to Units/Acre of application. Ground Speed Sensor: Set to RADAR or GPS. App Distance From GPS: Ignore this setting. Tgt Units:Contrler Units: Ignore this setting. Target Rate Increment: Ignore this setting. Actual Rate Scale Factor: Set to 1.000.

2. Press CONTRLER SETTINGS key. Set the following:

Flowmeter pulses/10 revs (PLANTING):
of sprocket for shaft speed sensor times ten. Example: If sprocket has 30 teeth then setting is 300 (30 x 10 = 300)
Number seeds/rev (PLANTING): Use the following formula to determine
this setting: # of seeds dispensed for 1 row
1 rev of sprocket
x Total # of rows
Example: 12 row planter, 6 seeds dispensed per row per one revolution of sprocket on planter transmission shaft. 6 x 12 = 72. Setting is 72. Area Count: Set to Standard if voltage from external switch goes high during operation. Set to Reversed if voltage from external switch goes low during operation. Standard is the normal setting. If this setting is changed
after the configuration is activated for a field, restart the monitor
to make the new setting take effect.
3 Exit back to main screen.
a)Press FIELD key twice. b)Select appropriate field and press VIEW CONFIG key. c)Select appropriate product/controller configuration and press ACTIVE
ON/OFF key to check it as active.(All other configs must be unchecked first).
d)Press ACCEPT key to accept field.
Set equal to the number of teeth

How to change a setting

Press the EDIT key and use the Up or Down Arrow keys to change the setting. For most settings, you can set each digit by pressing the Left or Right Arrow key to select the digit. Use the Up or Down Arrow keys to set the digit.

Area Counting

The area count switch (located on bottom right of front panel) must be up and flow must have started for area to be on.
Revision 3 3 of 3 P.N. 2002831-22