PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Rawson or New Leader controllers – March 2002
p
p
p
p
p
p
p
b
f
p
p
FIELD
[Create or change field and name field
functions. Active configuration for
field displayed.]
VIEW
CONFIG
[Set active configuration and active
tgt prescription file.]
ACTIVE
ON/OFF
[Select and accept new tgt
rescription file.]
EDIT
TGT FILE
VIEW
INFO
[Create or change load and
name load functions.]
Menu Key
FIELD LOAD
CAL SETUP
Press Menu Key to switch between Main Menu keys
LOAD
Press at
guidance
reference
SHOW MAP
[Splits screen and shows On
Screen Map on left side.
Press HIDE MAP key to
return to full screen. ]
SET A
eginning o
ass.
SET B
Press at end
of guidance
reference
ass. When
using curve
attern,
ress at end
of every
ass.
DIAG
RESET
Press to
reset
guidance
and area
oints to
start a new
field.
OPTIONS SHOW MAP
PAUSE
Press to
ause
guidance
when filling
applicator.
Drive back
to swath and
ress
RESUME
key.
LIGHTBARMARKS
OPTIONS
NAVIGATE
ADD/STRT
Used for
Headlands.
See Lightbar
Manual.
BOUNDARY
CLR/STOP
Used for
Headlands.
See Lightbar
Manual.
GRID
AREA PT
Press at every
corner of field to
calculate field
area. Must have
“Field Area”
displayed on
main screen to
see area.
[Screen displays field, product, units/ac and default
rate stored in tgt file.]
Revision 2 1 of 4 P.N. 2002831-19
PF3000 and PF3000 Pro – Application Rate Mode - Menu Tree for Rawson or New Leader controllers – March 2002
p
N
N
g
Menu Key
FIELD LOAD
OPTIONS SHOW MAP
CAL
AREA
DISTANCE
[Radar calibration screen]
[Screen Displays all product/controller
configurations]
EDIT
SETTINGS
CREATE
NEW
Settings
Controller Make
Controller Model
Product
Units
Ground Speed Source
App Distance From GPS
Full Swath
Tgt Units:Contrler Units
Target Rate Increment
Actual Rate Scale Factor
ADVANCED
SETTINGS
CONTRLER
SETTINGS
APP RATE
CONFIG
DELETE
CAL SETUP
Press Menu Key to switch between Main Menu keys
MARKS
CARD
LOAD
Settings
Logging device
Logging interval
Log file
[To erase files,
ress SHOW
ALL FILES key,
select file, press
FILE OPTIONS
key and press
ERASE FILE
key.]
SETUP
CONSOLE
Settings
Operating mode
Units of Measure
Month/Day/Year
Time
Serial number
Box cal
Voltage cal
GPS check sum
Field marker input
Display brightness
DIAG
MEMORY
[Clear data in
loads or erase
all fields
functions]
Selections
MEA MESSAGE
GPS/PORT CONFIGURATION
BEACON DIFFERENTIAL
SATELLITE DIFFERENTIAL
LIGHTBAR
GUIDANCE
Guidance Screen Settings
Pattern
Headland Type
Look-Ahead
Display Mode
Swath Direction
Swath Width
Antenna Offset
Pass Skips
Units Displayed
Contour Log Interval
GPS
MAP
DIAG
SYSTEM
SENSORS
GPS
RAW
NMEA
Satellite Differential Screen Settings
Differential source = BEACON or WAAS or SATELLITE
Differential provider
Satellite frequency
Satellite baud rate
Provider user code
Omnistar code
Subscription expiration
Age of differential
Settings
Target rate outside field
Controller time delay
Actual rate units
actual rate
Lo
Settings
ominal rate
Percent rate change
Cal. number for act. rate
Actual rate source
Revision 2 2 of 4 P.N. 2002831-19
PF3000 and PF3000 Pro – Quick Reference Setup Instructions for all Rawson and New Leader models – March 2002
Note: These instructions pertain to PF firmware versions 4.00 or
higher.
Settings for Rawson and New Leader Controllers
1. Press SETUP key. Press APP RATE CONFIG key. Press CREATE
NEW key. Set the following:
Controller Make: Set to RAWSON or NEW LEADER.
Controller Model: Set to your controller model.
Product: Press EDIT key. You can select an existing product and press
ACCEPT key or create a new product by pressing CREATE NEW key.
Press EDIT NAME key and enter name of product. Use Left or Right
Arrow keys to select a character. Use Up or Down Arrow key to change
the character. Set every character and press ACCEPT key twice.
Units: Set to Units/Acre of application.
Ground Speed Sensor: Set to RADAR or GPS. Note: This setting affects
all configurations.
App Distance From GPS: Set to distance between where product exits
applicator and position of GPS antenna on vehicle. Example: If planter is
20 feet behind GPS antenna set to 20 ft back.
Full Swath: Set to full swath of applicator.
Tgt Units:Contrler Units: Normally set to 1:1.0000. This ratio is used to
convert the units in a target file (.tgt) to the units of application.
Example: Tgt file in pints/ac of Treflan, controller applies gallons/ac. If
tank mix is 1 pint of Treflan / 10 gallon water, then set to 1:10.0000.
Target Rate Increment: Determines increment value by which you can
change the manual target rate with each press of Up or Down arrow keys.
Actual Rate Scale Factor: Set to 1.000
2. Press CONTRLER SETTINGS key. Set the following:
Nominal Rate: If PF not controlling rate, ignore setting.
If PF controlling rate, set equal to nominal rate of contrl. (Mode key):
“Sds/A=x,xxx,xxx” setting in Rawson plant mode or
“Rate=xxxx.x Lb/A” setting in Rawson fert mode (dry) or
“Rate=xx.x Gal/A” setting in Rawson fert mode (liquid) or
“Yield=xxxx Lb/A (or Ton/A if lime)” setting in New Leader
Note: If change modes on controller, must change nominal rate on PF.
Percent Rate Change: Set equal to “Steps x.x%” of contrl. (Mode key)
Common settings are 4.00% for Rawson plant mode, 6.66% for New
Leader or Rawson fert mode (Steps x.x% may not be setting in cont.)
Cal. number for act. rate:
Rawson – planting mode - Press Mode key on controller to view the “#
of seeds=xxx.x” and “No. of Rows=xx” setting. Use formula to
determine cal. number.
# of seeds
x No. of rows x 10 = cal. number
5
Rawson – fertilizer mode (liquid) - Press Mode key on controller to
view “Pump Disp x.xxxx”, “RateSetting xx.x” and “Ratio=xx.xx:1”
setting. Use formula to determine cal. number.
Pump Disp x Rate Setting x 10000
Ratio
= cal. num
Rawson – fertilizer mode (dry) - Press Mode key on controller to view
“Del. Rate=xxx.xx”, “Mat’l=xxx.x Lb”, “Rate Setting xx.xx” and
“Ratio=xx.xx:1” setting. Use formula to determine cal. num.
Del. Rate x Mat'l x Rate Setting x .5787
Ratio
= cal. number
Note: See note for New Leader
New Leader - Press Mode key on controller to view “FeedGate=xx.xx”,
“Mat’l=xxx.x Lb”, and “Conv. Rate=x.xxx” settings. Use formula to
determine cal. number.
Feed Gate x Mat'l x Conv. Rate x 1000 (5 if lime)
6.1
Note: Actual rate will be 1/10
If cal. number is over 6400, divide cal. number by 10. Ex.
7000/10=700 (act. rate will be 1/100
th
of real actual rate (except for lime).
th
of real actual rate). If gate
= cal. number
setting changes, switch configurations and enter new cal. number.
Actual Rate Source: Set to DRIVE RPM. If you are planting and have a
Dickey-john Seed Manager monitor and you want to get the actual rate
from it, set this to SEED MANGR.
Revision 2 3 of 4 P.N. 2002831-19
PF3000 and PF3000 Pro – Quick Reference Setup Instructions for all Rawson and New Leader models – March 2002
3 Press EXIT key to return to screen with ADVANCED SETTINGS key on
bottom. Press the ADVANCED SETTINGS key.
Target Rate Outside Field: This only pertains to using a target file.
Set to ZERO if want rate outside field to be zero.
Set to USE LAST if want rate to be the last rate used at the time the
vehicle is detected outside the field. This is useful when experiencing
problems with the vehicle being falsely detected outside of the field
during the outside pass.
Set to TGT DEFAULT if want rate outside field to be the default rate
stored in the target rate file.
Controller Time Delay: Set to 3 seconds. This is delay of controller to
change application equipment to new rate + 2 seconds.
Actual Rate Units: Ignore this setting.
Log Actual Rate: Set to YES to log actual rate to card. Set to NO,
otherwise.
4 Exit back to main screen.
a)Press FIELD key twice.
b)Select appropriate field and press VIEW CONFIG key.
c)Select appropriate product/controller configuration and press ACTIVE
ON/OFF key to check it as active.(All other configs must be unchecked
first).
d)If you will be using a target file, press EDIT TGT FILE key, otherwise
press EXIT key and skip to step f.
e)Select target file. Press VIEW INFO key to ensure it is the correct one.
After exiting view info screen, press ACCEPT key. Press EXIT key.
f)Press ACCEPT key to accept field.
How to change a setting
Press the EDIT key and use the Up or Down Arrow keys to change the setting.
For most settings, you can set each digit by pressing the Left or Right Arrow
key to select the digit. Use the Up or Down Arrow keys to set the digit.
Setting the Target Rate
1 The display item “Target Rate” must be displayed on the main screen to
set the rate.
Arrow symbols on the line displaying target rate indicate that this display
item is selected for changing. Press the key to the right of the line
displaying target rate if you do not see these arrows. Press it again to
deselect the line (remove the box) but keep the arrow symbols.
2 Note: Set Rawson or New Leader to GPS Mode (under Mode key) to
enable serial port communication with controller.
On the PF, you can either set a manual rate or use a target file to
automatically control the rate based on the vehicle position in the field.
Setting a manual rate
a) Press Right Arrow key to highlight “man” (“m” if viewing on screen
map).
b) Use the Up or Down Arrow keys to set the manual rate.
c) If you want to change how much the rate changes with each arrow
press refer to step 1 on other side of sheet and edit the “Target Rate
Increment” setting.
Using a target file and setting an automatic rate
a) Press Left Arrow key to highlight “auto” (“a” if viewing on screen
map).
b) You must have a target file (.tgt) selected for the field, otherwise the
PF will not control the rate of the Rawson. Refer to step 4 on other
side on how to set the Target File.
You can switch between auto and man whenever you are on the main
screen and Target Rate is selected for changing.
Setting the PF to NOT control the rate (record rate only)
Set the Target Rate to “auto” and leave the Target File setting on
“NONE”.
Area Counting
The area count switch (located on bottom right of front panel) must be up and
the Drive must be turning for area to be on.
Revision 2 4 of 4 P.N. 2002831-19
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.