No part of this manual may be reproduced
in any form or by any means (including
electronic storage and retrieval or translation into a foreign language) without prior
agreement and written consent from
Agilent Technologies, Inc. as governed by
United States and international copyright
laws.
Manual Part Number
N9360-90002
Edition
Third Edition, March 2008
Printed in Malaysia
Agilent Technologies Microwave Products
(Malaysia) Sdn. Bhd.
Bayan Lepas Free Industrial Zone
11900 Penang, Malaysia
Warranty
The material contained in this document is provided “as is,” and is subject to being changed, without notice,
in future editions. Further, to the
maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied,
with regard to this manual and any
information contained herein, including but not limited to the implied
warranties of merchantability and fitness for a particular purpose. Agilent
shall not be liable for errors or for
incidental or consequential damages
in connection with the furnishing,
use, or performance of this document
or of any information contained
herein. Should Agilent and the user
have a separate written agreement
with warranty terms covering the
material in this document that conflict with these terms, the warranty
terms in the separate agreement
shall control.
Technology Licenses
The hardware and/or software described
in this document are furnished under a
license and may be used or copied only in
accordance with the terms of such license.
Restricted Rights Legend
computer software” as defined in FAR
52.227-19 (June 1987) or any equivalent
agency regulation or contract clause. Use,
duplication or disclosure of Software is
subject to Agilent Technologies’ standard
commercial license terms, and non-DOD
Departments and Agencies of the U.S.
Government will receive no greater than
Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S. Government users will receive no greater than
Limited Rights as defined in FAR 52.227-14
(June 1987) or DFAR 252.227-7015 (b)(2)
(November 1995), as applicable in any
technical data.
Safety Notices
A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like
that, if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and
met.
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly performed or adhered to, could result
in personal injury or death. Do not
proceed beyond a WARNING
notice until the indicated conditions are fully understood and
met.
If software is for use in the performance of
a U.S. Government prime contract or subcontract, Software is delivered and
licensed as “Commercial computer software” as defined in DFAR 252.227-7014
(June 1995), or as a “commercial item” as
defined in FAR 2.101(a) or as “Restricted
N9360A Multi UE Tester Quick Reference Guideii
Preface
Thank-you for purchasing the Agilent N9360A mobile communciations
tester.
•Before using the tester, the user is advised to read this manual
carefully to ensure correct usage and also to fully utilize the tester
capability.
•This manual is a reference document and the user is advised to keep it
carefully for future reference.
•The manual includes the the tester operation, test procedures and
screen references.
•Refer to the N9360A Multi UE Tester Installation Guide for information
regarding installation and details of the tester. Refer also to the
N9360A W-CDMA Option User Manual and N9360A cdma2000 Option
User Manual for information about the test functions of the Wideband
Code Division Multiple Access (W-CDMA), and Code Division Multiple
Access (cdma2000).
Notation
The following notations are used in this manual:
•Softkey: indicates a softkey;
Notices
Tra de mar ks
•[Screen Name]: indicates a screen name;
•Tester/tester : indicates the N9360A Multi UE Tester.
•The information contained in this manual is subjected to change with
notice.
•No part of this manual may be reproduced either mechanically,
electronically or otherwise, without permission from Agilent
Technologies, Inc.
•Ethernet is the registered trademark of the Xerox Corporation.
•EPSON is the registered trademark of the EPSON Corporation.
•Other product names and companies used herein are trademarks or
registered trademarks of their respective companies or Agilent
Technologies, Inc. For registered trademarks, the trademarks symbols
® and ™ are omitted in this manual.
•cdma2000 is a registered trademark of Telecommunication Industry
Association (TIA-USA).
N9360A Multi UE Tester Quick Reference Guideiii
THIS PAGE IS INTENTIONALLY LEFT BLANK.
ivN9360A Multi UE Tester Quick Reference Guide
Contents
Notation I-iii
Notices I-iii
Trademarks I-iii
1Legal Information
Legal Information 1-2
Warranty 1-2
Technology Licenses 1-2
Restricted Rights Legend 1-2
Service And Support 1-3
Agilent On The Web 1-3
Agilent By Phone 1-3
2Caution and Safety Requirements
Safety Information 2-2
Safety Summary 2-2
Safety Notices 2-2
Warning Label 2-2
General 2-3
When Operating The Tester 2-3
3General Operation
Using a USB memory device 3-2
Using the Knob on the Front Panel 3-2
Using the Knob on the Front Panel 3-2
Preparation for Tests 3-3
GSM/W-CDMA/cdma2000 Mobile Phone Repair Process 3-4
4GSM System
For Go/No-Go Testing 4-2
For Pinpointing Failures 4-3
For Troubleshooting 4-5
N9360A Multi UE Tester Quick Reference Guidev
5W-CDMA System
6cdma2000 System
RF Channels 4-7
MS Power Control / Power Class 4-7
RX Level 4-9
RX Quality 4-10
For Go/No-Go Testing 5-2
For Pinpointing Failures 5-3
For Troubleshooting 5-4
UARFCN 5-5
Mobile Phone Maximum Output Power 5-5
When "CDMA Mode" is set to MC-1x mode 6-2
When "CDMA Mode" is set to 1xEV-DO mode 6-6
viN9360A Multi UE Tester Quick Reference Guide
1
Legal Information
Warranty 1-2
Technology Licenses 1-2
Restricted Rights Legend 1-2
Service And Support 1-3
Agilent On The Web 1-3
Agilent By Phone 1-3
Agilent Technologies
1-1
1Legal Information
Legal Information
Warranty
The material contained in this document is provided “as is,” and
is subject to being changed, without notice, in future editions.
Further, to the maximum extent permitted by applicable law,
Agilent disclaims all warranties, either express or implied, with
regard to this manual and any information contained herein,
including but not limited to the implied warranties of
merchantability and fitness for a particular purpose. Agilent
shall not be liable for errors or for incidental or consequential
damages in connection with the furnishing, use, or performance
of this document or of any information contained herein.
Should Agilent and the user have a separate written agreement
with warranty terms covering the material in this document
that conflict with these terms, the warranty terms in the
separate agreement shall control.
Technology Licenses
The hardware and/or software described in this document are
furnished under a license and may be used or copied only in
accordance with the terms of such license.
Restricted Rights Legend
If software is for use in the performance of a U.S. Government
prime contract or subcontract, Software is delivered and
licensed as “Commercial computer software” as defined in
DFAR 252.227-7014 (June 1995), or as a “commercial item” as
defined in FAR 2.101(a) or as “Restricted computer software” as
defined in FAR 52.227-19 (June 1987) or any equivalent agency
regulation or contract clause. Use, duplication or disclosure of
Software is subject to Agilent Technologies’ standard
commercial license terms, and non-DOD Departments and
Agencies of the U.S. Government will receive no greater than
Restricted Rights as defined in FAR 52.227-19(c)(1-2)(June
1987). U.S. Government users will receive no greater than
Limited Rights as defined in FAR 52.227-14 (June 1987) or
DFAR 252.227-7015 (b)(2)(November 1995), as applicable in any
technical data.
1-2N9360A Multi UE Tester Quick Reference Guide
Service And Support
Agilent On The Web
Agilent By Phone
Legal Information1
Any adjustment, maintenance, or repair of this product must be
performed by qualified personnel. Contact your customer
engineer through your local Agilent Technologies Service
Center.
You can find information about technical and professional
services, product support, and equipment repair and service on
the Web: http://www.agilent.com/
Double-click the link to Test & Measurement. Select your country
from the drop-down menus. The Web page that appears next has
contact information specific for your country
If you do not have access to the Internet, call one of the
numbers in Table 1-1.
Table 1-1 Agilent Call Centers and Regional Headquarters
United States and Canada:Test and Measurement Call Center
Safety Summary 2-2
Safety Notices 2-2
Warning Label 2-2
General 2-3
When Operating The Tester 2-3
Agilent Technologies
2-1
2Caution and Safety Requirements
CAUTION
WARNING
Safety Information
Safety Summary
Safety Notices
The following general safety precautions must be observed
during all phases of operation of this instrument. Failure to
comply with these precautions or with specific warnings
elsewhere in this manual violates safety standards of design,
manufacture, and intended use of the instrument. Agilent
Technologies, Inc. assumes no liability for the customer's failure
to comply with these requirements.
A CAUTION notice denotes a hazard. It calls attention to an
operating procedure, practice, or the like, that, if not correctly
performed or adhered to, could result in damage to the product or
loss of important data. Do not proceed beyond a CAUTION notice
until the indicated conditions are fully understood and met.
A WARNING notice denotes a hazard. It calls attention to an
operating procedure, practice, or the like that, if not correctly
performed or adhered to, could result in personal injury or death.
Do not proceed beyond a WARNING notice until the indicated
conditions are fully understood and met.
Warning Label
A warning label is stuck on the front panel of the Tester.
Do not remove, damage or modify the warning label.
2-2N9360A Multi UE Tester Quick Reference Guide
General
WARNING
WARNING
CAUTION
CAUTION
Caution and Safety Requirements2
The protection provided by the N9360A tester may be impaired if
the tester is used in a manner not specified by Agilent or the
instructions on the display are not followed.
DO NOT INSTRUMENT COVERS. Operating personnel must not
remove any instrument covers. Component replacement and
internal adjustments must be made only by qualified service
personnel. Products that appear damaged or defective should be
made inoperative and secured against unintended operation until
they can be repaired by a qualified service personnel.
When Operating The Tester
Make sure that the input signal level does not exceed the maximum
level allowed. Tester failure may result otherwise.
Do not turn off the Line switch on the rear panel of the Tester while
the LINE LED on the front panel of the Tester is lit in green.
Otherwise, Tester failure may occur.
N9360A Multi UE Tester Quick Reference Guide2-3
2Caution and Safety Requirements
THIS PAGE IS INTENTIONALLY LEFT BLANK.
2-4N9360A Multi UE Tester Quick Reference Guide
3
General Operation
Using a USB memory device 3-2
Using the Knob on the Front Panel 3-2
Preparation for Tests 3-3
GSM/W-CDMA/cdma2000 Mobile Phone Repair Process 3-4
Agilent Technologies
3-1
3General Operation
Using a USB memory device
A USB memory device can be used to save and recall the test
procedures, to update the firmware of the Tester, and to save
screen images as image files.
Saving and Recalling Test Procedures:
All settings for Automatic Test, Manual Test, TX Analyzer,
Signal Generator, and Configuration can be saved into a test
procedure file.
To save a test procedure or to recall a pre-defined test
procedure, go to the [Configuration] screen, then the [File
Management] screen.
Updating the Firmware:
To update firmware of the Tester, press the FW Update softkey to
go to the [Firmware Update] screen on the [Configuration]
screen obtained from the [Top Menu] screen. Refer to the
“Firmware Update Screen” in the User's Guide for details.
Saving a Screen Image:
To enable this function, it is required to set the “Printer” input
field on the [Configuration] screen to
a screen image into a USB memory device, press the Print Screen
softkey. The file format is PNG (Portable Network Graphics).
USB Memory. Then, to save
Using the Knob on the Front Panel
1. Rotate the knob to place
the cursor next to the input
field where you want to
change.
2. Push the knob to select
the field where you placed
the cursor.
3. Rotate the knob to
change the value in the
field.
3-2N9360A Multi UE Tester Quick Reference Guide
4. Push the knob to set the
value.
Preparation for Tests
Figure 3-1 Typ ic a l Te s t S et up
General Operation3
Connecting RF Signal:
1 Connect the mobile phone to the Tester using the
user-supplied RF Cable, optional Antenna Coupler, or
optional Shield Case.
2 On the [Loss] screen obtained from the [Initial],
[Configuration] and [Configuration: Test Condition] screens,
set the “Loss” field to
values for each Radio System or Band in the “RF In” and “RF
Out” fields depending on the RF connection.
On and enter the appropriate loss
Connecting a Printer:
• Connect a printer to print a hardcopy of the test results if
required.
Inserting the TEST SIM for GSM mobile phone or TEST USIM for a
W-CDMA mobile phone:
• Insert the Test SIM (Subscriber Identity Module) supplied by
Agilent into the GSM mobile phone or the test USIM
(Universal Subscriber Identity Module) supplied by Agilent
into the W-CDMA mobile phone before performing any test.
• GSM/W-CDMA/cdma2000 Mobile Phone Repair Process
N9360A Multi UE Tester Quick Reference Guide3-3
3General Operation
GSM/W-CDMA/cdma2000 Mobile Phone Repair Process
Figure 3-2 Mobile Phone Repair Process
A typical GSM, W-CDMA and cdma2000 mobile phone repair
process at service centers is basically divided into two
processes, Incoming Inspection and Mechanical & Module
Repair. In each process, you can perform the following tests
with the Agilent N9360A Multi UE Tester.
Table 3-1 Mobile Phone Repair Function
ProcessTestAgilent N9360A Multi UE
Tester Function
Incoming InspectionGo/No-Go TestAutomatic Test
Module RepairPinpointing FailuresAutomatic Test
TroubleshootingManual Test
AdjustmentTX Analyzer, Signal Generator
Final Test
(Go/No-Go Test)
Automatic Test
3-4N9360A Multi UE Tester Quick Reference Guide
4
GSM System
For Go/No-Go Testing 4-2
For Pinpointing Failures 4-3
For Troubleshooting 4-5
RF Channels 4-7
MS Power Control / Power Class 4-7
RX Level 4-9
RX Quality 4-10
Agilent Technologies
4-1
4GSM System
For Go/No-Go Testing
Figure 4-1 [Automatic Test: Stand-by] Screen
1 Press the Automatic Test softkey on the [Initial] screen in GSM
system.
2 Move the cursor to the “Procedure” field, and select a
pre-defined test procedure.
3 Press the Start softkey.
4 Turn the mobile phone on. Wait for the completion of
Location Update.
5 Operate the mobile phone as instructed in the table below.
Each test flow step is highlighted as it runs.
6 After completing the test, check the results on the screen.
7 To print the test results or to save them into a USB memory
device, press the More (1 of 2) softkey and then the Print Screen
softkey.
4-2N9360A Multi UE Tester Quick Reference Guide
Table 4-2 GSM Automatic test sequence
StepAction needed
Location UpdateWait until the Location Update is complete.
MS CallDial an arbitrary number and press the Off Hook key
TalkTalk to the mobile phone to judge its loop back sound
RF TestWait until the RF test is complete.
MS ReleaseFinish the call from the mobile phone.
BS CallRespond to the call on the mobile phone.
BS ReleaseWait until the call is finished from the Tester.
For Pinpointing Failures
GSM System4
on the mobile phone.
quality and press the Pass or Fail softkey.
Figure 4-2 [Automatic Test: Stand-by] Screen
1 Perform the steps described in “For Go/No-Go Testing.”
2 Press the Screen>> softkey to set screen mode to Detail or
Val ue.
N9360A Multi UE Tester Quick Reference Guide4-3
4GSM System
Sensitivity
RX Quality
RX Level
Phase Error
Frequency Error
Burst Timing
Power Ramp
Peak TX
Power
3 Rotate the knob to place the cursor in one of the Pass/Fail
cells on the detail screen or test result cells on the value
screen. Then, press the knob.
4 One of the following measurement result screens is displayed
according to your selection in step 3.
• To print the measurement results or to save them into a
USB memory device, press the Print Screen softkey.
• In the graphical display, you can use the marker function
to read data points by rotating the knob.
• The zoom function is available on the power ramp graph
display by pressing the Zoom Off/On softkey.
Figure 4-3 Various [Automatic Test: Stand-by] Screens
5 To display other measurement result screens or to finish
analysis, press the Return softkey to display the previous
screen.
4-4N9360A Multi UE Tester Quick Reference Guide
For Troubleshooting
GSM System4
Figure 4-4 [Manual Test (GSM): Stand-by] Screen
1 Press the Manual Test softkey on the [Initial] screen.
2 Move the cursor to the “Procedure” field and select a
pre-defined test procedure.
3 Turn the mobile phone on.
4 Wait for the completion of Location Update.
5 Press the BS Call softkey and respond to the call on the
mobile phone when it is called. Or, dial an arbitrary number
and press the Off Hook key on the mobile phone to start the
MS Call.
6 To start measurement while the left screen is displayed, refer
to step 7. For detailed measurement at each measurement
item, refer to step 8.
N9360A Multi UE Tester Quick Reference Guide4-5
4GSM System
Spectrum
Monitor
Sensitivity
RX Quality
RX Level
Phase Error
Frequency Error
Peak TX Power/ Burst
Timing/ Power Ramp
Figure 4-5 Various [Manual Test (GSM): Stand-by] Screens
7 While “Connection” is highlighted in the test flow, press the
Tr ig g e r softkey to start single measurement or the Tr ig ge r
Sing/Cont softkey to start continuous measurement. Press the
Tri gge r S i ng /
measurement.
8 Place the cursor at one of the groups of the test items and
press the knob or press the Spectrum Monitor softkey to display
a measurement result screen according to your selection.
Then, press the Tr ig ge r softkey to start single measurement or
Tr ig g e r
Cont softkey again to terminate the continuous
Sing/Cont softkey to start continuous measurement.
4-6N9360A Multi UE Tester Quick Reference Guide
Press the Tr i gg er S in g /Cont softkey again to terminate the
NOTE
continuous measurement.
9 In the graphical display, the marker function is available to
read the data points by rotating the knob. On the power ramp
graph display, the zoom function is also available.
10 To display other measurement result screens, press the
Return softkey to display the previous screen. To end the
entire test, press the Release softkey to start the BS Release,
or press the On Hook key on the mobile phone to finish the
MS Release.
RF Channels
Table 4-3 GSM RF channel frequencies and channel number
GSM850GSM900DCS1800PCS1900
GSM System4
Uplink824.2 to 848.8 MHz890.2 to 914.8 MHz
876.2 to 889.8 MHz
Downlink869.2 to 893.8 MHz935.2 to 959.8 MHz
921.2 to 934.8 MHz
ARFCN 128 to 2510 to 124
955 to 1023
GSM900 includes P-GSM, E-GSM, and R-GSM Bands.
MS Power Control / Power Class
Table 4-4 GSM Power Control levels
GSM 850 / 900DCS1800PCS1900
Power Control
Level
0 392936 3033
Nominal Power
(dBm)
Power Control
Level
Nominal Power
1710.2 to 1784.8 MHz1850.2 to 1909.8 MHz
1805.2 to 1879.8 MHz1930.2 to 1989.8 MHz
512 to 885512 to 810
(dBm)
Power Control
Level
Nominal Power
(dBm)
3 373034 3132
435 3132 030
533030 128
631128 226
N9360A Multi UE Tester Quick Reference Guide4-7
4GSM System
Table 4-4 GSM Power Control levels
GSM 850 / 900DCS1800PCS1900
Power Control
Level
729226 324
827324 422
925422 520
1023520618
1121618716
1219716814
1317814912
14159121010
15131010118
1611118126
179126134
187134142
195142150
Nominal Power
(dBm)
Power Control
Level
150
Nominal Power
(dBm)
Power Control
Level
Nominal Power
(dBm)
GSM 850 / 900DCS1800PCS1900
Power ClassMax Power
Control Level
1N/A 10 10
2223 23
33329 330
45
57
4-8N9360A Multi UE Tester Quick Reference Guide
Power ClassMax Power
Control Level
Power ClassMax Power
Control Level
GSM System4
RX Level
Table 4-5 RX levels
#RX Level#RX Level#RX Level
0≤−110 dBm22–89 to –88 dBm44–67 to –66 dBm
1–110 to –109 dBm23–88 to –87 dBm45–66 to –65 dBm
2–109 to –108 dBm24–87 to –86 dBm46–65 to –64 dBm
3–108 to –107 dBm25–86 to –85 dBm47–64 to –63 dBm
4–107 to –106 dBm26–85 to –84 dBm48–63 to –62 dBm
5–106 to –105 dBm27–84 to –83 dBm49–62 to –61 dBm
6–105 to –104 dBm28–83 to –82 dBm50–61 to –60 dBm
7–104 to –103 dBm29–82 to –81 dBm51–60 to –59 dBm
8–103 to –102 dBm30–81 to –80 dBm52–59 to –58 dBm
9–102 to –101 dBm31–80 to –79 dBm53–58 to –57 dBm
10–101 to –100 dBm32–79 to –78 dBm54–57 to –56 dBm
11–100 to –99 dBm33–78 to –77 dBm55–56 to –55 dBm
12–99 to –98 dBm34–77 to –76 dBm56–55 to –54 dBm
13–98 to –97 dBm35–76 to –75 dBm57–54 to –53 dBm
14–97 to –96 dBm36–75 to –74 dBm58–53 to –52 dBm
15–96 to –95 dBm37–74 to –73 dBm59–52 to –51 dBm
16–95 to –94 dBm38–73 to –72 dBm60–51 to –50 dBm
17–94 to –93 dBm39–72 to –71 dBm61–50 to –49 dBm
18–93 to –92 dBm40–71 to –70 dBm62–49 to –48 dBm
19–92 to –91 dBm41–70 to –69 dBm63≥−48 dBm
20–91 to –90 dBm42–69 to –68 dBm
21–90 to –89 dBm43–68 to –67 dBm
N9360A Multi UE Tester Quick Reference Guide4-9
4GSM System
RX Quality
Table 4-6 RX Quality
#RX Quality#RX Quality
0<0.2 %41.6 to 3.2 %
10.2 to 0.4 %53.2 to 6.4 %
20.4 to 0.8 %66.4 to 12.8 %
30.8 to 1.6 % 7>12.8 %
4-10N9360A Multi UE Tester Quick Reference Guide
5
W-CDMA System
For Go/No-Go Testing 5-2
For Pinpointing Failures 5-3
For Troubleshooting 5-4
UARFCN 5-5
Mobile Phone Maximum Output Power 5-5
Agilent Technologies
5-1
5W-CDMA System
For Go/No-Go Testing
Figure 5-1 [Automatic Test: Stand-by] Screen
1 Press the Automatic Test softkey on the [Initial] screen for
W-CDMA system.
2 Move the cursor to the “Procedure” field, and select a
pre-defined test procedure.
3 Press the Start softkey.
4 Turn the mobile phone on. Wait for completion of Location
Update.
5 Operate the mobile phone as instructed in the table below.
Each test flow step is highlighted as it runs.
6 After completing the test, check the results on the screen.
7 To print the measurement results or to save them into a USB
memory device, press the More (1 of 2) softkey and then the
Print Screen softkey.
5-2N9360A Multi UE Tester Quick Reference Guide
W-CDMA System5
Table 5-1 W-CDMA Automatic Test Sequence
StepAction needed
Location UpdateWait until the Location Update is completed.
MS CallDial an arbitrary number and press the Off Hook key
on the mobile phone.
TalkTalk to the mobile phone to judge its loop back sound
quality and press the Pass or Fail softkey.
MS ReleaseFinish the call from the mobile phone.
BS Call (AMR)Respond to the call on the mobile phone.
BS Call (RMC)The mobile phone automatically responds to the call.
RF TestWait until the RF test is completed.
BS ReleaseWait until the call is finished from the Tester.
For Pinpointing Failures
Figure 5-2 [Automatic Test: Stand-by] Screen
1 Perform the steps described in “For Go/No-Go Testing.”
2 Press the Screen>> softkey to set screen mode to Value.
3 Check the values of the measurement results.
N9360A Multi UE Tester Quick Reference Guide5-3
5W-CDMA System
For Troubleshooting
Figure 5-3 [Manual Test: Stand-by] Screen
1 Press the Manual Test softkey on the [Initial] screen.
2 Move the cursor to the “Procedure” field and select a
pre-defined test procedure.
3 Turn the mobile phone on.
4 Wait for the completion of Location Update.
5 Select “RMC” for BS Call at the “BS Call” input field.
6 Press the BS Call softkey.
7 While “Connection (RMC)” is highlighted in the test flow,
press the Tr ig g er softkey to start single measurement or the
Tr ig g e r
Press the Tr i gg er S in g /
Sing/Cont softkey to start continuous measurement.
Cont softkey again to terminate
continuous measurement.
8 Press the Release softkey to finish the Test.
5-4N9360A Multi UE Tester Quick Reference Guide
W-CDMA System5
UARFCN
Table 5-2 W-CDMA Frequency Band
BandUplink ; mobile phone transmitDownlink ; mobile phone receive
General AdditionalGeneralAdditional
I9612 to 9888—10562 to 10838—
II9262 to 953812, 37, 62, 87, 112, 137, 62, 187,
212, 237, 262, 287
III8562 to 8913—9037 to 9388—
IV8562 to 87631162, 1187, 1212, 1237,1262,
1287, 1312, 1337, 1362
V4132 to 4233782, 787, 807, 812, 837, 8624357 to 44581007, 1012, 1032, 1037, 1062, 1087
VI4162 to 4188812, 8374387 to 44131037, 1062
VIII2700 to 2875—2925 to 3100—
IX8750 to 8924—9225 to 9399—
9662 to 9938412, 437, 462, 487, 512, 537, 562,
587, 612, 637, 662, 687
10562 to 107631462, 1487, 1512, 1537, 1562, 1587,
1612, 1637, 1662
Mobile Phone Maximum Output Power
Table 5-3 UE Maximum Output Power
Power Class 1Power Class 2Power Class 3Power Class 4
Operating
Band
Band I+33+1/–3+27+1/–3+24+1/–3+21+2/–2
Power
(dBm)
To l.
(dB)
Power
(dBm)
To l.
(dB)
Power
(dBm)
To l.
(dB)
Power
(dBm)
To l.
(dB)
Band II+24+1/–3+21+2/–2
Band III+24+1/–3+21+2/–2
Band IV+24+1/–3——
Band V+24+1/–323+2/–2
Band VI+24+1/–3+23+2/–2
Band VIII+24+1/–3——
N9360A Multi UE Tester Quick Reference Guide5-5
5W-CDMA System
THIS PAGE IS INTENTIONALLY LEFT BLANK.
5-6N9360A Multi UE Tester Quick Reference Guide
6
cdma2000 System
When "CDMA Mode" is set to MC-1x mode 6-2
When "CDMA Mode" is set to 1xEV-DO mode 6-6
Agilent Technologies
6-1
6cdma2000 System
When "CDMA Mode" is set to MC-1x mode
For Go/No-Go Testing
Figure 6-1 [Auto Test (MC-1x): Stand-by] Screen
1 Press the Automatic Test softkey on the [Initial] screen in
cdma2000 system
2 Move the cursor to the "Procedure" field, and select a
pre-defined test procedure.
3 Press the Start softkey.
4 Turn the mobile phone on. Wait for the completion of
Location Update.
5 Operate the mobile phone as instructed in the table below.
Each test flow step is highlighted as it runs.
6 After completing the test, check the results on the screen.
7 To print the test results or to save them into a USB memory
device, press the More(1 of 2) softkey and then the Print
Screen softkey.
6-2N9360A Multi UE Tester Quick Reference Guide
cdma2000 System6
Table 6-1 cdma2000 Automatic Test Sequence
StepAction Needed
Location UpdateWait until the Location Update is complete.
MS Call (Talk)Dial an arbitrary number and press the Off
Hook key on the mobile phone.
TalkTalk to the mobile phone to judge its loop
back sound quality and press the Pass or Fail
softkey.
MS ReleaseFinish the call from the mobile phone.
BS Call (Talk)Respond to the call on the mobile phone.
BS Call (RF Test)The mobile phone automatically responds to
the call.
RF TestWait until the RF test is completed.
Softer HandoffWait until the Softer Handoff is completed.
BS ReleaseWait until the call is finished from the Tester.
N9360A Multi UE Tester Quick Reference Guide6-3
6cdma2000 System
For Pinpointing Failures
Figure 6-2 [Auto Test (MC-1x): Stand-by] Screen
1 Perform the steps described in "For Go/No-Go Testing.”
2 Press the Screen>> softkey to set screen mode to Value.
3 Check the values of the measurement results.
6-4N9360A Multi UE Tester Quick Reference Guide
For Troubleshooting
cdma2000 System6
Figure 6-3 [Manual Test (MC-1x): Stand-by] Screen
1 Press the Manual Test softkey on the [Initial] screen.
2 Move the cursor to the "Procedure" field and select a
pre-defined test procedure.
3 Set the Service Option field to 32.
4 Turn the mobile phone on.
5 Wait for the completion of Location Update.
6 Press the BS Call softkey.
7 While "Connection" is highlighted in the test flow, press the
Tr ig g e r softkey to start single measurement or the Tr ig g er
Sing/Cont softkey to start continuous measurement. Press the
Tri gge r S i ng /
Cont softkey again to terminate continuous
measurement.
8 Press the Release softkey to finish the test.
N9360A Multi UE Tester Quick Reference Guide6-5
6cdma2000 System
When "CDMA Mode" is set to 1xEV-DO mode
For Go/No-Go Testing
Figure 6-4 [Auto Test (1xEV-DO): Stand-by] Screen
1 Press the Automatic Test softkey on the [Initial] screen in
cdma2000 system
2 Move the cursor to the "Procedure" field, and select a
pre-defined test procedure.
3 Press the Start softkey.
4 Turn the mobile phone on. Wait for the completion of UATI
Assinment.
5 Each test flow step is highlighted as it runs.
6 After completing the test, check the results on the screen.
7 To print the test results or to save them into a USB memory
device, press the More(1 of 2) softkey and then the Print Screen
softkey.
6-6N9360A Multi UE Tester Quick Reference Guide
cdma2000 System6
Table 6-2 1xEVDO Automatic Test Sequence
StepAction Needed
UATI AssignmentWait until the UATI Assignment is completed.
BS CallThe mobile phone automatically responds to the
call.
RF TestWait until the RF test is completed.
Softer HandoffWait until the Softer Handoff is completed.
Connection CloseWait until the connection is closed.
Session CloseWait until the session is closed.
For Pinpointing Failures
Figure 6-5 [Auto Test (1xEV-DO): Stand-by] Screen
1 Perform the steps described in "For Go/No-Go" Testing".
2 Press the Screen>> softkey to set screen mode to Value.
3 Check the values of the measurement results.
N9360A Multi UE Tester Quick Reference Guide6-7
6cdma2000 System
For Troubleshooting
Figure 6-6 [Manual Test (1xEV-DO): Stand-by] Screen
1 Press the Manual Test softkey on the [Initial] screen.
2 Move the cursor to the "Procedure" field and select a
pre-defined test procedure.
3 Press the UATI Assign softkey.
4 Turn the mobile phone on, and wait for the completion of
UATI Assignment.
5 Press the BS Call softkey.
6 While "Connection" is highlighted in the test flow, press the
Tr ig g e r softkey to start single measurement or the Tr ig g er
Sing/Cont softkey to start continuous measurement. Press the
Tri gge r S i ng /
measurement.
7 Press the Release softkey to finish the test.
Cont softkey again to terminate continuous
6-8N9360A Multi UE Tester Quick Reference Guide
RF Channel
Table 6-3 cdma2000 Frequency Band
Radio SystemChannel Number
1024 ~ 1323
cdma2000 System6
BAND0: CEL US
991 ~ 1023
1 ~ 799
1024 ~ 1323
BAND1: PCS US
991 ~ 1023
1 ~ 799
1041 ~ 1199
BAND3: Cel JP
1201 ~ 1600
801 ~ 1039
1 ~ 799
BAND4: PCS KR601 ~ 1300
1 ~ 600
BAND6: IMT-2K0 ~ 1199
† The BAND15: AWS is available only when the Option C03 is installed in the Tester.
N9360A Multi UE Tester Quick Reference Guide6-9
6cdma2000 System
THIS PAGE IS INTENTIONALLY LEFT BLANK.
6-10N9360A Multi UE Tester Quick Reference Guide