AEG BSK882320M Installation Guide

INSTALLATION
EN
IMPORTANT INFORMATION
These instructions should be read in conjunction with the user manual. Adherence to the directions for use in the user manual is extremely important for health and safety. Failure to strictly adhere to the requirements in the user manual may result in personal injury, property damage and affect your ability to make a claim under the manufacturer’s warranty provided with your product. Products must be used, installed and operated in accordance with the user manual.
EN
Installation Instruction
Warning! Before proceeding with installation, read
the safety information in the User Manual.
The oven is designed to be connected to 230 - 240V ~ (50Hz) electricity supply. The oven has an easily accessible terminal block which is marked as follows: Letter L - Live terminal Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical
supply must comply to the specications given below.
For UK use only
Connection via
Cooker Control Circuit
It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3 mm between the switch con­tacts and of a type suitable for the required load in com­pliance with the current regulations.
The switch must not break the yellow and green earth cable at any point.
Min. size
Cable/ex
2,5 mm² PVC / PVC
Cable/ex
type
twin and earth
Fuse
min: 15 A max: 20 A
After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient temperature. Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.
The manufacturer declines any responsibility should these safety measures not be carried out.
Attention: The new appliance may only be installed and
connected by a registered expert.
Please comply with this. If you do not, any
damage resulting is not covered by the warranty.
Safety information for the installer
• The electrical installation is to be set up so that the appliance can be isolated from the mains with a minimum 3 mm all-pole contact separation.
• Suitable separation devices include e.g. cut-outs, fuses (screw fuses are to be taken out of the holder), RCD’s and contactors.
• Anti-shock protection must be provided by the installation.
• The built-in unit must meet the stability requirements of DIN 68930.
• Built-in ovens and built-in cooking surfaces
are tted with special connection systems.
For safety reasons, they must only be combined with appliances from the same manufacturer.
5