C A U T I O N !
CUSTOMER ACCESS
NETWORK INTERFACE DEVICE
WARNING!
COVER TO BE
REMOVED BY TELEPHONE
COMPANY PERSONNEL
ONLY
SUBJECT TO ELECTROSTATIC DAMAGE
PRACTICES
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
T400 SINGLE ENVIRONMENTAL HOUSING
INSTALLATION/MAINTENANCE
CONTENTS
1. GENERAL............................................................... 1
2. INSTALLATION ...................................................... 1
3. REPLACEMENT PARTS ....................................... 4
4. MAINTENANCE ..................................................... 4
5. WARRANTY AND CUSTOMER SERVICE ........... 4
FIGURES
Figure 1. T400 Single Environmental Housing ............ 1
Figure 2. Clearances .................................................... 2
Figure 3. Mounting Holes ............................................. 2
Figure 4. Wiring Terminals ........................................... 2
Figure 5. T400 Environmental Housing Assembly....... 3
Figure 6. Surge Arrestors and the
Insertion/Extraction Tool ............................... 3
TABLES
Table A. Wiring ............................................................. 3
Section 61150.087L1-5
Issue 1, August 1996
CLEI Code # DDMOJHD1 _ _
1. GENERAL
This practice provides installation and maintenance
information for the ADTRAN T400 Single
Environmental Housing, part number 1150087L1.
Figure 1 is a view of the T400 Single Environmental
Housing.
Features
The basic features of the T400 Single Environmental
Housing, part number 1150087L1, include the
following:
• Houses one of the following circuit packs: FNID,
BRIDLE-R, HTU-R, HRE, or Total Reach
• Seals the T400 circuit packs from the environment
• Allows separate, unsealed access to the customer
and network wiring
• Mounts above ground to a pole or wall
• Compact T400 Environmental Housing - 9" High x
3/4
3
" Deep x 8
5/8
" Wide, 2.6 lb. with mounting
bracket
• Four replaceable gas-tube surge arrestors that
provide primary lighting protection
Figure 1. T400 Single Environmental Housing
2. INSTALLATION
The T400 Environmental Housing consists of a base,
cover, O-ring, mounting bolts for the base, mounting
bracket, lag screws and spacers for the mounting
bracket. See Figures 2, 3, 4 and 5.
The T400 Single Environmental
Housing is designed for above
ground only mounting. Never install
telephone wiring during a lightning
storm.
Install Mounting Bracket
1. Clearances between the T400 Environmental
Housing and adjacent structures must be observed
1Section 61150087L1-5, Issue 161150.087L1-5A
for access during maintenance. Note clearances
required for removing the Environmental Housing.
See Figure 2 for mounting clearances.
2. Place the mounting bracket 3/4" spacers between
the rear of the mounting bracket and the mounting
surface. The spacers are required to insure the
mounting bracket is not warped during installation
or use.
3. Insert the 1/4" x 1
1/2
" Hex head lag screws through
the mounting holes of the mounting bracket and
spacers. Tighten securely with a 7/16" nut driver.
Mounting
Holes
3/8
5 "
9.0"
8.5"
1.0"
1.0"
6.0"
Figure 2. Clearances
Install the T400 Environmental Housing
1. Fasten the Environmental Housing to the mounting
bracket using the two mounting bracket bolts.
3/4
"
3/16
4 "
Figure 3. Mounting Holes
3. Connect the ground cable to an appropriate
ground. (Surge arrestors work only when the
ground cable is connected.)
4. Replace the network cover on the base using a
7
/16" nut driver. Tighten to 20 in-lbs.
Customer Wiring
1. Remove the customer cover on the base using a
flat-head screwdriver.
2. Connect the wiring in the terminal blocks as shown
in Table A. The terminal block will accommodate
a #6 Spade Lug. The terminal blocks are shown
in Figure 4.
3. Replace the customer cover on the base using a
flat-head screwdriver.
2. Tighten the two bolts using a 7/16" nut driver to
25 in-lbs.
Power Modules in the central office should be
removed or de-energized prior to installation
5 15 49 55 NC
7 13 41 47 11
and maintenance of the T400 Single
Environmental Housing. Appropriate Methods
and Procedures should be followed to insure
personal safety.
CUSTOMER ACCESS
NETWORK INTERFACE DEVICE
WARNING!
COVER TO BE
REMOVED BY TELEPHONE
COMPANY PERSONNEL
ONLY
Network Wiring
Figure 4. Wiring Terminals
1. Remove the network cover on the base using a
7/16" nut driver.
2. Connect the wiring in the terminal blocks as shown
Remove the Environmental Housing Cover
1. Wipe any debris from the cover and base.
in Table A. The terminal block will accommodate
a #6 Spade Lug.
2. Remove the two housing cover bolts using a 7/16"
nut driver.
2 Section 61150087L1-5, Issue 1 61150.087L1-5A