belshaw-adamatic.com
Serving the donut and bakery industry for over 85 years
1-800-578-2547 ▪ info@belshaw-adamatic.com ▪ www.belshaw-adamatic.com
Belshaw Adamatic
BARP-3 Series Retarder-Proofer,
2-Door, Roll-in
(Triple-wide rack capacity)
Construction
Stainless steel exterior with 300 Series s/s interior and ▪
aluminized steel top
Foamed insulation in walls ceilings and doors ▪
Modular wall and ceiling panels with cam lock ▪
construction
Rapid responding air-wash heat and humidity system ▪
Heavy duty welded s/s hinges ▪
Rapid responding air-wash heat and humidity system ▪
Depth up to 120”, capacity up to 18 racks ▪
208/240 VAC, either 1 or 3-phase, eld convertible ▪
Includes condenser standard ▪
Refrigeration components compatible with R404A ▪
refrigerant
Operation
Dual purpose, provides both proong and retarding ▪
70°-120° F proong range ▪
34°-45° F retarding range ▪
50 - 99% humidity range ▪
Non-submerged calrod type heaters ▪
Evaporators sized for high humidity levels, prevents ▪
drying
Refrigeration system sized for rapid pull down ▪
Interior bumpers, lighted interior ▪
BARP-3-40 Retarder Proofer
Controls
Digital set Temperature, Humidity, Time ▪
PID type controls for rapid accurate response without ▪
overshoot
Operates in individual modes or automatic mode ▪
All digital controls mounted in the door at eye-level ▪
Large LED display w/ Real-time clock ▪
Options
Stainless steel oor ▪
Refrigeration condenser (requires separate connection) ▪
Prison package ▪
Model/Rack Capacity*
Model / Depth Side Load
28.4”Wx18.0”D
End Load
26.0”Wx20.4”D
Double
28.4”Wx36.0”D
BARP-3-30 3 Racks 4 Racks None
BARP-3-40 6 Racks 4 Racks 3 Racks
BARP-3-50 8 Racks 7 Racks 3 Racks
BARP-3-80 13 Racks 11 Racks 6 Racks
BARP-3-110 18 Racks 16 Racks 8 Racks
*Racks may be snug at maximum capacity. For details of rack
arrangement, see the Rack Capacity Guide at http://www.belshaw-
adamatic.com/specs/belshaw-adamatic-rack-capacity-guide.pdf
Short Bid Specication
Rack Proofer Model BARP-3-xxx [insert 30, 40, 50, 80, or 110]
shall be a 5 to 13.2 kW electrically heated, double door roll-in
rack unit with: quick responding air-wash heat / humidity system;
modular cam lock panel construction with foamed insulation; all
stainless steel interior, with protective cart bumpers; heavy-duty
doors with magnetic seal/mechanical closure system and full
width protective bar handle; simple computerized controls, door
mounted at eye-level, with accurate digital temperature, humidity
and time readouts; plus all the features listed and options
checked.
Standard Product Warranty
One-Year Parts and Labor, USA and Canada.
(USA includes 50 states + DC unless specied)
Certications
.
BELSHAW ADAMATIC BAKERY GROUP 206-322-5474 ▪ 800-578-2547 ▪ info@belshaw-adamatic.com
814 44th St NW, Suite 103, Auburn, WA 98001 USA • www.belshaw-adamatic.com
©2009 Belshaw Adamatic Bakery Group Specications are subject to change without notice.

BARP-3 Series Retarder-Proofer, 2-Door
C
with ceiling-mounted Condenser
Add 16.9”
91.4
Opening Width
Specications
Model
BARP-3-30 7000
88.5
Retarder
BTU’s
3.7
for Drain
Water and �
Electrical �
13.5 from �
74.1
Opening Height
88.00
4.0
Drain
37
D
Overall�
edge
A
Depth
Freight Class=70
Height Width Depth Approx Weight (lbs)
Int Ext Int Ext “A” “B” “C” “D” Actual Ship
68” 26” 35.25” 31.13” 1372 1472
102.5
84.5
Inside Width
BARP-3-40 9000 78” 36” 45.25” 41.13” 1457 1582
BARP-3-50 9000 88” 46” 55.25” 51.13” 1597 1722
74.1” 91.4” 96.6” 102.5”
BARP-3-80 15,000 118” 76” 85.25” 81.13” 1957 1082
BARP-3-110 18,000 148” 106” 115.25” 119.13” 2494 2619
Electrical Requirements
Model Voltage Total kW 1-Phase 3-Phase Condenser
BARP-3-(30-40-50-80) 208 VAC 5 kW 24.0 A 13.8 A
240 VAC 6.6 kW 27.5 A 15.8 A
BARP-3-110 208 VAC 10.2 kW 48.0 A 27.6 A
240 VAC 13.2 kW 55 A 31.6 A
Volts: 208/240/60/1
Amps: 6A-18A. Condenser model depends
on target minimum temperature chosen.
Condenser specs: http://www.belshaw-adamatic.
com/specs/belshaw-adamatic-retarder-proofer-BARP-
condenserspecs.pdf
B
Inside Depth
Water Supply and Drainage Requirements
Model Water Supply Drainage
BARP-3-(30-40-50-80) 1/2” NPT .07 GPM @ 60 PSI 1/2”PVC; 110°F
BARP-3-110 1/2” NPT .14 GPM @ 60 PSI
Installation Requirements
Requires on-site installation ▪
KD shipment. When disassembled, can t through 36” ▪
opening
Refrigeration condenser requires separate connection ▪
Consult factory for shipment fully assembled ▪
208/240 VAC, either 1 or 3-phase eld convertible ▪
1/2” NPT cold water conection ▪
1/2” PVC vented drain connection ▪
Refrigeration system must be installed by a licenced refrig- ▪
eration technician
This appliance is designed to operate at normal room ▪
temperatures; if installed next to an oven or other heat
source allow a minimum clearance of 4” to prevent heat
2” clearance on both sides, required for door to open 90° ▪
For install on non-porous surfaces only ▪
Your local water conditions may damage your appliance. ▪
Failure to properly treat water may result in damage and
may void your warranty. Ensure that your water supply
meets these minimum water quality specications:
<1 GPM Max
Vented
Alkalinity: 22 ppm Aluminum: 17 ppm Calcium: 3.3 ppm Free chlorine residual: 0.6 ppm Magnesium: 0.65 ppm PH range: 8.5 s.u. Sodium: 8.5 ppm -
Total Hardness: 11.9 ppm transfer.
Clearance from combustibles is 0” sides and back ▪
BELSHAW ADAMATIC BAKERY GROUP 206-322-5474 ▪ 800-578-2547 ▪ info@belshaw-adamatic.com
814 44th St NW, Suite 103, Auburn, WA 98001 USA • www.belshaw-adamatic.com
©2009 Belshaw Adamatic Bakery Group Specications are subject to change without notice.