Single Rack Oven, Electric
BARO-1E-208V
BARO-1E-240V
BARO-1E-480V
BARO-2E
Double Rack Oven, Electric
BARO-2E-208V
BARO-2E-240V
BARO-2E-480V
OPERATOR MANUAL
ADAMATIC, Inc.
607 Industrial Way
Eatontown, NJ 07724
BELSHAW BROTHERS, Inc.
814, 44th Avenue NW
Auburn, WA 98001
Phone: 800.526.2807
www.adamatic.com
Phone: 800.578.2547
www.belshaw..com
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND
AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
POST IN A PROMINENT LOCATION:
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THAT USER SMELLS GAS. THIS
INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER.
AS A MINIMUM, TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR
AUTHORIZED SERVICE AGENT. EVACUATE ALL PERSONNEL FROM THE AREA.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
DANGER POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH.
WARNING POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH OR SERIOUS INJURY.
CAUTION POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, MAY RESULT IN MINOR OR MODERATE INJURY.
NOTICE Helpful operation and installation instructions and tips are
present.
Model #: Purchased From:
Serial #:
Location:
Date Purchased:
Purchase Order #:
Date Installed:
For Service, Call:
ETL File 3028821 Rev B 2007 - - 2 -
TABLE OF CONTENTS
CHAPTER PAGE
1. TABLE OF CONTENTS ............................................................................... 3
13. QUICK GUIDE TO USING THE BARO OVEN CONTROLS ……..……...45
ETL File 3028821 Rev B 2007 - - 3 -
WARNING THE WATER FROM THE STEAM DRAIN OUTLET IS EXTREMELY
HOT AND MAY CAUSE SERIOUS BURNS.
NOTICE
Left rear drain point is provided. Route to a floor drain. A 1”
gap must be provided between oven drain and floor drain.
WARNINGS
PG. 7
PG. 7
WARNING WIRES ENTERING THE DISCONNECT MAY STILL BE LIVE EVEN
WHEN THE SWITCH IS TURNED OFF. SWITCH THE MAIN BREAKER
AT THE WALL TO “OFF” WHEN SERVICING THE OVEN
CAUTION
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE
MOUNTED ON FLOORS OF NON-COMBUSTIBLE CONSTRUCTION
WITH NON-COMBUSTABLE FLOORING AND SURFACE FINISH AND
WITH NO COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE
THEREOF, OR ON NON-COMBUSTABLE SLABS OR ARCHES
HAVING NO COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE.
SUCH CONSTRUCTION SHALL EXTEND A MINIMUM OF 12-INCHES
BEYOND THE EQUIPMENT ON ALL SIDES. See fig. 1
Fig. 1
Floor
Construction
PG.
8,16
PG. 9
ETL File 3028821 Rev B 2007 - - 4 -
WARNINGS CONT’D
WARNING
WARNING
CAUTION
CAUTION
WARNING
WARNING
DO NOT UNLOAD THE RACK FROM THE OVEN WHILE THE
CARRIER IS IN THE LIFT POSITION. LOADED RACKS CAN BE
EXTREMELY HEAVY.
DO NOT REMOVE A FLAMING PRODUCT FROM THE OVEN.
SEVERE BURNS AND PROPERTY DAMAGE CAN RESULT.
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL
CODE, ANSI/NFPA 70-1996.
FOR INSTALLATION IN CANADA THE INSTALLATION MUST BE IN
ACCORDANCE WITH CAN/CGA-B149.1&2 OF THE INSTALLATION
CODE, AND LOCAL CODES WHERE APPLICABLE. ALL ELECTRIC
WIRING MUST BE IN ACCORDANCE WITH THE CURRENT
CANADIAN ELECTRICAL CODE, C22.1 PART 1. GROUNDING THIS
APPLIANCE MUST CONFORM TO CANADIAN ELECTRICAL CODE,
CSA C22.2.
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING
IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL
AND /OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
DO NOT ALLOW ANY PART OF YOUR BODY TO BE UNDER THE
OVEN DURING THE LIFTING PROCESS. KEEP EVERYONE CLEAR
FROM THE OVEN IF IT SHOULD FALL.
PG. 14
PG. 14
PG. 9
PG. 10
PG. 10
PG. 10
NOTICE
NOTICE
WARNING
NOTICE
CAUTION
CAUTION
It is imperative that a mechanical exhauster is installed, and a
pressure sensitive switch is installed at the collar of the hood. If a
negative draw of 0.6 is not achieved, the burner will not come on.
No other exhaust systems may be connected to this system. Do not
try to vent or exhaust another appliance into this hood.
WHEN REMOVING THE RACK OR PRODUCT FROM THE RACK
WEAR OVEN MITTS TO AVOID SERIOUS BURNS.
Always ensure the grease filters supplied with the oven are used.
Replacement filters may be ordered.
IF BLOWER ROTATION IS INCORRECT, IT WILL CAUSE SEVERE
DAMAGE TO HEAT EXCHANGER
CAUTION SHOULD BE TAKEN WHEN ENCLOSING HOOD TO
CEILING AND OVEN IS UNDER A FIRE SPRINKLER; HOOD
EXHAUST STACK WILL EMIT HEAT.
PG. 12
PG. 12
PG. 14
PG. 12
PG.
14,19
PG. 19
ETL File 3028821 Rev B 2007 - - 5 -
WARNING
WARNINGS CONT’D
THIS BAKERY OVEN PRODUCES HUMIDITY THAT CAN CAUSE
THE INTERIOR FLOORING AND ADJACENT EXTERIOR FLOORING
TO BECOME SLIPPERY. USE EXTREME CAUTION WHEN WALKING
ON A WET OR DAMP FLOOR.
PG. 15
NOTICE
NOTICE
WARNING
NOTICE
NOTICE
NOTICE
The ambient temperature outside the oven should not exceed 104° F
(40° C). This includes the temperature of the air above and around
the oven.
During the first few hours of operation you may notice a small
amount of smoke coming off of the oven, and a faint odor from the
smoke. This is normal for a new oven and will disappear after the
first few hours of use.
WHEN THE LOADING DOOR IS OPENED, HOT AIR AND STEAM ARE
RELEASED FROM THE OVEN INTERIOR. TO AVOID BURNS OPEN
DOOR SLOWLY AND KEEP YOUR FACE AND HANDS CLEAR OF
THE OPENING. ALL INTERIOR SURFACES ARE VERY HOT. DO NOT
TOUCH ANYTHING WITHOUT OVEN MITTS.
The steam, vent and fan functions cannot be used together in the
same step.
Service on this, or any other, ADAMATIC/BELSHAW appliance must be
performed by qualified personnel only. Consult your authorized
service agency directory or call the factory at 1-800-578-2647
for the service agent nearest you.
To maintain safety and performance for BELSHAW/ADAMATIC
oven models BARO-1E & BARO-2E, it is recommended that a program
of scheduled periodic maintenance be implemented. It is the sole
responsibility of the user to establish, schedule and enforce such a
program. Although the actual service interval will vary depending on
the environment in which the equipment is operating, it is
recommended the following be done by a BELSHAW/ADAMATIC
service agency at least every 6 months.
PG. 15
PG. 15
PG. 15
PG. 18
PG. 17
PG. 17
NOTICE
WARNING
NOTICE
For periodic maintenance and repairs, electrical diagrams are
included in this manual and with the oven (on the back of the control
door).
SINCE RESETS FOR THE CIRCULATION BLOWER MOTOR AND THE
LIFTER MOTOR / ROTATOR MOTOR ARE AUTOMATIC, ALL POWER
TO THE OVEN MUST BE TURNED OFF BEFORE SERVICING.
If shutter settings are to be adjusted differently than the
recommended factory settings, the best results will be obtained if
you; (A) Start with the factory settings; (B) Close shutters to lighten
a product in a given area- do not open shutters to darken a product;
(C) Do not move a shutter more than 1/32” or 1mm (see step gauge
and shutter setting illustration) at any one time; (D) Be sure all
settings for left hand shutters match those for right hand shutters;
and (E) Do not adjust more than two shutters per side per time (four
shutters total).
PG. 17
PG. 18
PG. 18
ETL File 3028821 Rev B 2007 - - 6 -
EQUIPMENT DESCRIPTION
Data Plate
On this plate you will find the oven model, serial number, electrical ratings, (BTU’s, and gas type for gas ovens),
and clearance specification. Data plate is located behind the controller door on component cover.
Exterior Construction
BARO-1E exterior dimensions are 55” (139.7 cm) wide x 105” (266.7 cm) high x 51” (129.5 cm) deep at
The
the base.
The
BARO-2E exterior dimensions are 72” (182.9 cm) wide x 105” (265.4 cm) high x 62” (157.5 cm) deep at
the base.
The Top, Front, Back, and Sides are constructed of stainless steel with 5 inches of insulation.
Floor level loading.
Type I or Type II hood with single point exhaust connection complying with Uniform Mechanical Code and
NFPA 96.
The oven door is constructed of stainless steel with a full height single pane window and an interior releasing
mechanism.
Externally mounted florescent light.
Interior Construction
BARO-1E cavity dimensions are 28” (92.71 cm) wide x 75” (190.5 cm) high x 39” (99.06 cm) deep at its
The
deepest point. The interior is constructed of stainless steel.
The BARO-2E cavity dimensions are 40” (92.71 cm) wide x 75” (190.5 cm) high x 50” (99.06 cm) deep at its
deepest point. The interior is constructed of stainless steel.
Smooth and simple rack loading and unloading.
Gentle rack lift and rotation protects delicate products.
The rack is designed to hold up to twenty 18”x 26” sheet pans.
A built in steam generator produces steam quickly.
Fully adjustable airflow for even cooking.
Controls
Large digital display which is easy to understand and operate.
Icon-driven (touch) panel allows for easy operation.
Pre-Programmable Product Selections.
Heat Loss Compensation for consistent baking.
Technical
The oven requires a 208/240 VAC three-phase power supply and a 115 VAC single phase power supply for
controls.
The oven requires no clearance from combustible wall construction.
WARNING THE WATER FROM THE STEAM DRAIN OUTLET IS EXTREMELY
Steam Drain Outlet
Water exits the steam generating system through this outlet It is located at the lower right-hand jamb or left rear
corner of the oven.
NOTICE
HOT AND MAY CAUSE SERIOUS BURNS.
Left rear drain point is provided. Remove the plug from
the location required and route to a floor drain. A 1” gap
must be provided between oven drain and floor drain.
ETL File 3028821 Rev B 2007 - - 7 -
EQUIPMENT DESCRIPTION CONT’D
Floor Drain
This drain (customer supplied) receives the excess water from the steam generating system.
Rack Carrier
When the loading door is closed, the rack carrier lifts and rotates the oven rack.
Rack Stop
The two rack stops are located on the carrier and secure the oven rack in place during baking. The leading
edge of the forward stop must be manually flipped down to unload the oven rack. The stop will
automatically return to the up (loading) position when the rack is removed.
Hood
Steam and burner exhaust is discharged into the hood. Grease is channeled to and collected in a grease
cup for later removal.
Hood Exhaust
Exhaust passes through a duct to the hood exhaust outlet. A customer-supplied exhaust blower is
required. The hood can be wired to the external device terminals in the service box. This insures the hood
is on whenever the oven is on. The “POWER” switch on the oven control panel activates the blower. The blower must be running before the oven will operate. A factory installed airflow switch disables heat
until airflow exists.
Interior Door Release
This door release allows the door to be opened from inside the oven.
WARNING WIRES ENTERING THE DISCONNECT MAY STILL BE LIVE EVEN
WHEN THE SWITCH IS TURNED OFF. SWITCH THE MAIN
BREAKER AT THE WALL TO “OFF” WHEN SERVICING THE
OVEN
3-Phase Circuit Breaker
This disconnect provides short circuit protection for the circulation blower motor. Switch to “OFF” when
servicing the oven.
Element Circuit Breakers
There are circuit breakers installed to provide short circuit protection for the elements.
Main Power Connection
A 4-pole terminal block located in the lower control panel for the incoming power connection.
Control Connection
A 2-pole terminal block and 1-pole circuit breaker is located above the controls for power hook up for the
controls.
Hood Supply
A 1-pole circuit breaker is provided to supply power to the ventilator hood.
CAUTION
CAUTION SHOULD BE TAKEN WHEN ENCLOSING HOOD TO
CEILING AND OVEN IS UNDER A FIRE SPRINKLER; HOOD
EXHAUST STACK WILL EMIT HEAT.
ETL File 3028821 Rev B 2007 - - 8 -
CAUTION
Receiving the Oven
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be noted on
the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss or damage means
loss or damage which does not become apparent until the merchandise has been unpacked. If concealed
loss or damage is discovered upon unpacking, make a written request for inspection by the carrier's agent
within 15 days of delivery. All packing material should be kept for inspection. Do not return damaged
merchandise to
Pre-Installation
Check the area where the oven is to be installed for the following:
• No electrical conduit or wires are to be under the floor of the oven.
• The oven must be mounted on a non-combustible surface. This includes the structure beneath the
floor. The floor must be level within 3/4”. See Fig. 1 Page 4, and above CAUTION!
•Ceiling height above the oven should be sufficient to allow servicing the lifter, vent, and blower
motor assemblies. The maximum height needed for tilting the oven up is 105 inches.
•Clear access is needed to the roof or exterior of the facility for hood exhaust. Check local codes for
correct venting.
•Caution should be taken when enclosing hood to ceiling and oven is under a fire sprinkler; hood
exhaust stack will emit heat.
• Access is needed for an air-gap drain in the rear left corner of the oven.
• Adequate space is needed in front of the oven to load and unload racks. Racks are hot and need
space to cool.
• The hood exhaust will need at least 600 CFM of make-up air.
• Local and national codes will require an electrical shut-off within a reasonable distance to the oven.
• Local and National codes will require access to a manual Gas Shut-off.
• The door swing will need to be clear to allow adequate loading and unloading of the oven. Check
the space next to the oven and be sure it does not interfere with the door.
Un-Crating
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE
MOUNTED ON FLOORS OF NON-COMBUSTIBLE
CONSTRUCTION WITH NON-COMBUSTABLE FLOORING AND
SURFACE FINISH AND WITH NO COMBUSTIBLE MATERIAL
AGAINST THE UNDERSIDE THEREOF, OR ON NONCOMBUSTABLE SLABS OR ARCHES HAVING NO
COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE. SUCH
CONSTRUCTION SHALL EXTEND A MINIMUM OF 12-INCHES
BEYOND THE EQUIPMENT ON ALL SIDES. See fig. 1 Page 4.
Belshaw or Adamatic. File your claim with the carrier.
INSTALLATION INSTRUCTIONS
The oven is shipped in one piece. (It can be uncrated and split in two for easier installation where door
openings are limited to 36 inches.)
Move the large oven crate into the room, near where it is to be installed. Allow clear access for a forklift
or lifting apparatus at the top end of the oven. The bottom end of the oven crate is beveled at the skids.
Check the crate for damage that may have occurred in shipping.
Remove crating materials and plastic wrap from the oven. Remove the heat exchanger vent duct from the
skid.
CAUTION THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY
GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE
ABSENCE OF LOCAL CODES, WITH THE NATIONAL
ELECTRICAL CODE, ANSI/NFPA 70-1996.
ETL File 3028821 Rev B 2007 - - 9 -
INSTALLATION CONT’D
CAUTION FOR INSTALLATION IN CANADA THE INSTALLATION MUST BE
IN ACCORDANCE WITH CAN/CGA-B149.1&2 OF THE
INSTALLATION CODE, AND LOCAL CODES WHERE
APPLICABLE. ALL ELECTRIC WIRING MUST BE IN
ACCORDANCE WITH THE CURRENT CANADIAN ELECTRICAL
CODE, C22.1 PART 1. GROUNDING THIS APPLIANCE MUST
CONFORM TO CANADIAN ELECTRICAL CODE, CSA C22.2.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING.
IMPROPER INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND /OR DAMAGE TO EQUIPMENT. UNIT MUST
BE INSTALLED N ACCORDANCE WITH ALL APPLICABLE
CODES.
WARNING
Raising
Raise the oven to its vertical, upright position with the use of a forklift or other lifting device.
Provide a means to lower the oven to the floor without dropping.
•Secure two 5,000 lb. lifting straps to the rear lifting eyes on top of the oven and to a point on the
forklift 40 inches from the mast.
•Secure a third 5,000 lb. strap to the front lifting eye on top of the oven and to the carriage of the
forklift. This strap should be situated so that it will prevent the oven from falling forward when it is
near upright.
•Raise the forks and slowly move forward, keeping the lifting straps vertical. Slowly move forward
until the oven is upright.
•Remove all straps and lifting equipment.
Raise the front of the oven with a pry bar and attach the front wheel assembly (located in the hood crate)
to the left front door jamb using #¼-20 truss-head screws provided.
Rotate the rear leveling adjusters clockwise until the rear wheels have extended and allow the rear of the
oven to roll.
DO NOT ALLOW ANY PART OF YOUR BODY TO BE UNDER THE
OVEN DURING THE LIFTING PROCESS. KEEP EVERYONE
CLEAR FROM THE OVEN IF IT SHOULD FALL.
ETL File 3028821 Rev B 2007 - - 10 -
INSTALLATION CONT’D
Setting
Remove the vinyl protective coating from all of the exterior surfaces.
Roll the oven into its final installed position. (You may wish to install the hood before locating the oven.)
Adjust the left front leveling screw until the weight is removed from the wheel assembly. Remove the
wheel assembly.
Adjust the rear leveling screws and the left front leveling screws until the left jamb is level from left to
right and front to back. Lock the left front adjusting screw in place.
Close the loading door. Adjust the right front leveling screw until the gap at the top of the door opening is
even all across. Check the gap along the left side of the door. Recheck the level of the oven.
Loosen the floor clamp screws around the perimeter of the oven floor.
Walk around the stainless floor until it is in full contact with the concrete floor. Retighten the floor clamp
screws.
Drill the floor with a 3/8” diameter drill to accept the concrete floor anchors.
•Mark the drill bit at 1-1/2” from the end with tape. Drill until the mark is at the top of the stainless
steel floor. Do not drill too deep.
• Clean the holes of concrete dust.
• If the oven is mounted on stone or ceramic tile, extend the holes and the anchors into the concrete
substrate.
Install the anchors in the holes and set in place with the anchor setting tool. (Note: One good solid blow is
better than many little taps.)
Install the #¼-20 flat head screws in the anchors. Use the anchor washers at the holes in the middle of the
floor at the larger anchor holes. Additional screws have been provided in the event that a hole is drilled
too deep.
Adjust the Loading door latch to ensure a good seal around the door. Do not over tighten the door.
Check the level of the rack carrier shaft. Place an accurate level on the top of the carrier and rotate the
carrier to the four points of the compass. The level bubble should be in the same position relative to the
carrier when rotated. If not, remove the carrier and level the shaft.
•Loosen the four corner screws on the rotator shaft level adjusting plate on the underside of the inner
ceiling. Remove the two remaining screws.
• Move the shaft manually until the shaft is level in all four directions.
• Retighten the four corner screws.
• Drill two new screw holes in the adjusting plate with a #7 drill bit and tap #¼-20. Install the two
remaining screws to lock the shaft level in place.
ETL File 3028821 Rev B 2007 - - 11 -
INSTALLATION CONT’D
NOTICE Always ensure the grease filters supplied with the oven are
used. Replacement filters may be obtained from an BELSHAW orADAMATIC representative.
NOTICE No other exhaust systems may be connected to this system. Do
not try to vent or exhaust another appliance into this hood.
Installing the Hood
•Remove the hood from the hood crate. Place the body of the hood on the floor with the open side
down. Use cardboard or other protective material to avoid scratches.
•Remove all protective vinyl coatings and place the hood side support trim on each side of the hood
and screw to the front of the hood with (4) #1/4-20 stainless steel truss head machine screws and
spacer bushings. Install (4) #10-32 truss head stainless steel machine screws through the side
support trim and into the top of the hood.
•Attach the rear trim to the opposite end of the hood side support trim using (4) #10-32 truss head
stainless steel machine screws.
•Place the combustion exhaust duct (shipped strapped to the oven skid) on the top of the heat
exchanger exhaust opening.
•Lift the hood and trim assembly and place it over the top of the oven so that the side and rear trim
rest on the top of the oven.
•Push the hood assembly toward the rear of the oven and align the vent exhaust opening and the
exhaust duct opening with the associated ducts on the oven.
•Attach the hood side support trim and the rear trim to the top of the oven with #10-32 stainless steel
truss head machine screws.
• Attach the hood to the exhaust and vent ducts using #10 stainless steel sheet metal screws.
• Install the hood airflow sensor tube at the hood collar opening and at the airflow switch at the
junction box located at the top of the oven. Double-check this connection for leaks or crimps in the
tube or hose.
•Install the hood deflector using #10-32 stainless steel round head machine screws at the back of the
deflector and #10-32 stainless steel truss head machine screws at three holes at the front edge of the
deflector.
•Place the three hood filters and the filler channel in the hood filter holder and onto the front lip of
the hood.
•Place the hood grease cup on the rear lip of the hood at the drain opening.
Connecting Utilities
•Connect the electrical service connection to the oven. Consult the data plate for specific current and
voltage ratings. Wire in compliance with local requirements and the National Electric Code. See
drawing on page 16.
•Connect water supply to the oven at the water solenoid valve at the top left corner of the oven.
Water supply must be between 20 and 80 PSI at all times with a water flow of 5 gallons per minute.
Provide a water shut-off valve near the oven for servicing.
•Connect the drain to the oven. Water drained from the oven will reach temperatures near boiling.
The drain line must be provided with an air gap to prevent back siphoning.
NOTICE
It is imperative that a mechanical exhauster is installed, and a
pressure sensitive switch is installed at the collar of the hood. If a
negative draw of 0.6 is not achieved, the burner will not come on.
ETL File 3028821 Rev B 2007 - - 12 -
INSTALLATION CONT’D
CAUTION
ETL File 3028821 Rev B 2007 - - 13 -
IF BLOWER ROTATION IS INCORRECT, IT WILL CAUSE SEVERE
DAMAGE TO HEAT EXCHANGER
INSTALLATION CONT’D
Start-up
Remove all protective coatings from the oven surface, inside and out.
Turn on the water supply to the oven. Check for leaks. Repair any leaks before proceeding.
Confirm that all electrical connections are proper and all covers are in place. Confirm that the oven is
properly grounded.
Turn on electrical power to the oven. Turn on all circuit breakers located in the electrical compartments.
Turn the “ON/OFF” switch on the control panel to the “ON” position. The oven interior light should turn
on and the control display should light up.
Close the loading door. The lifter and rack carrier should lift and begin to rotate. Open the door and
allow the carrier to stop rotating. Check the position of the alignment of the carrier to the door. If the
carrier needs adjustment, remove the chrome caps from the center channel on the rack carrier. Loosen the
four setscrews that lock the carrier to the shaft. Rotate the carrier until it aligns with the door and
retighten the setscrews. Replace the chrome caps.
Place an oven rack in the oven. Measure the spacing between the oven rack top channels and the rack
carrier. The space between the carrier lip and the top flange of the rack channel should be approximately
¾”. Adjust the lifter micro-switch mount on the lifter body to compensate.
Close the loading door and check toe direction of rotation of the blower motor. The motor should rotate
counterclockwise when viewed from the top. Reverse the direction of rotation by reversing L1 and L3 at
the motor contactor.
Heat the oven to 300°F. (Refer to the programming section of this manual for control operating
instructions.)
Check the oven for leaks, excessive smoke, vibration, and general operation.
EMERGENCY OPERATION
WARNING
Power Failure
Do not attempt to operate oven.
Turn the power to “OFF”.
Remove the product from the rack.
WARNING
Product fire in the baking chamber
1. Turn power switch to “OFF”.
2. Wait until the fire has gone out before opening the door.
WARNING
ETL File 3028821 Rev B 2007 - - 14 -
WHEN REMOVING THE RACK OR PRODUCT FROM THE RACK,
WEAR HOT MITTS TO AVOID SERIOUS BURNS.
DO NOT UNLOAD THE RACK FROM THE OVEN WHILE THE
CARRIER IS IN THE LIFT POSITION. LOADED RACKS CAN BE
EXTREMELY HEAVY.
DO NOT REMOVE A FLAMING PRODUCT FROM THE OVEN.
SEVERE BURNS AND PROPERTY DAMAGE CAN RESULT.
WARNING
GENERAL OPERATION
THIS BAKERY OVEN PRODUCES HUMIDITY THAT CAN
CAUSE THE INTERIOR FLOORING AND ADJACENT EXTERIOR
FLOORING TO BECOME SLIPPERY. USE EXTREME CAUTION
WHEN WALKING ON A WET OR DAMP FLOOR.
NOTICE
NOTICE During the first few hours of operation you may notice a small
WARNING
Typical Operation
• Preheat oven to desired temperature and allow oven to saturate for 20 minutes.
• The steam generator absorbs heat and normalizes temperature in the cooking chamber.
• Select a cooking program from the main menu of pre-saved programs. When selected, the
temperature setting changes to the correct temperature for the product.
• Load a rack full of product into the oven, engaging the rack carrier automatically.
• The door of the oven is closed and the rack is lifted off of the floor, allowing it to rotate smoothly.
• If a steam time has been set, water flows into the steam generator and cascades through the labyrinth
of heat reserves, converting the water into steam, which condenses on the food product.
•When the steam cycle ends (within 60 seconds), the circulation blower starts and air is blown past
the heat exchanger and through the rack full of product.
•The rotation of the rack insures that the product is cooked evenly throughout the rack. If venting is
desired, such as with breads, the vent cycle is selected when the program is started.
•The vent opens for a limited time, allowing dry air to be drawn into the oven and forcing moist air
out into the hood.
•The computer control manages all of the timing and temperature functions and sounds an alarm at
the end of the baking cycle.
• Open the cooking chamber door and wait until the rack is rotated so that it is aligned with the door.
• Release the latch at the top of the rack and remove the rack from the oven.
The temperature outside the oven should not exceed 104° F (40°
C). This includes the temperature of the air above and around
the oven.
amount of smoke coming off of the oven, and a faint odor from
the smoke. This is normal for a new oven and will disappear
after the first few hours of use.
WHEN THE LOADING DOOR IS OPENED, HOT AIR AND STEAM
ARE RELEASED FROM THE OVEN INTERIOR. TO AVOID BURNS
OPEN DOOR SLOWLY AND KEEP YOUR FACE AND HANDS
CLEAR OF THE OPENING. ALL INTERIOR SURFACES ARE
VERY HOT. DO NOT TOUCH ANYTHING WITHOUT OVEN MITTS.
ETL File 3028821 Rev B 2007 - - 15 -
GENERAL OPERATION CONT’D
Loading Procedures
Set the controls.
Open the door (slowly). Wait for the rack carrier to stop and lower.
Confirm that the rack stop is in the loading (LEADING FLAP UP) position.
Align the top channels of the oven rack with the rack carrier and push the rack past the rack stop.
Close the loading door. The rack carrier will automatically lift the rack and begin to rotate.
Begin baking by pressing START. A buzzer will sound when baking is completed.
Unloading Procedure
Press the STOP button or open the loading door to turn off the buzzer.
You can view your product through the window. If it appears ready, SLOWLY open the loading door
about 6 inches. Let steam and hot air escape from the opening (to be removed through the hood.)
Open the door completely. The rack carrier will come to a stop and the rack will lower.
USING OVEN MITTS, flip the rack stop to the unloading (LEADING FLAP DOWN) position.
Remove the rack from the rack carrier.
Close the loading door.
Shut Down Procedure
1. Turn the power switch to the “OFF” position.
2. For lengthy shutdown periods or maintenance, turn power off at the 208/240 volt and 120 volt power
disconnects.
WARNING
3. Switch the oven disconnect to “OFF”.
WIRES FROM THE SERVICE ENTRANCE MAY STILL BE LIVE,
EVEN WHEN SWITCHES ARE TURNED OFF. TURN POWER OFF
AT MAIN BREAKER BEFORE SERVICING.
SEE PROGRAMMING MANUAL FOR CONTROL PANEL INSTRUCTIONS
ETL File 3028821 Rev B 2007 - - 16 -
GENERAL MAINTENANCE
NOTICE
NOTICE
Preventative Maintenance
1. Verify hood exhaust air-pressure switch is operating properly.
2. Inspect heat exchanger for cracks, openings or excessive corrosion.
3. Check loading door handle & striker adjustment and verify the mounting screws are tight.
4. Check interior loading door release for proper operation.
5. Clean hood filters with soap and water.
6. Check and tighten any loose screws on both the interior and exterior of the oven.
7. Check the rack lift assembly for proper operation. Adjust limit switch as needed.
8. Check rotator chain adjustment and its alignment on the rack rotator assembly. Lubricate the drive
chain if applicable.
9. Clean flour and dust that may have accumulated on top of the oven and circulation blower motor.
10. Check burner manifold for smooth ignition. Flour and dust can accumulate on Inshot burners.
Misaligned Inshot burners or cracks in heat exchanger can also cause rough ignition.
11. Check steam system for proper operation and drainage.
12. Clean / de-scale steam system spray nozzles and drain pain, if needed.
13. Check vent for proper operation.
14. Check loading door switch actuator for proper adjustment.
15. Check the loading door seal and door sweep condition.
16. Check control panel for proper operation.
NOTICE
Service on this BELSHAW/ADAMATIC appliance must be
performed by qualified personnel only. Consult your authorized
service agency directory or call the factory at 1-888-578-2547
for the service agent nearest you.
To maintain safety and performance for BELSHAW/ADAMATIC
Rack oven models BARO-1E & BARO-2E, it is recommended that a
program of scheduled periodic maintenance be implemented. It
is the sole responsibility of the user to establish, schedule and
enforce such a program. Although the actual service interval will
vary depending on the environment in which the equipment is
operating, it is recommended the following be done by an
authorized service agency at least every 6 months.
For periodic maintenance and repairs, electrical diagrams are
included in this manual and available from BELSHAW/ADAMATIC
ETL File 3028821 Rev B 2007 - - 17 -
GENERAL MAINTENANCE CONT’D
WARNING
Motor Reset
One of the overload protectors may require resetting if the circulation blower does not start, if it quits, or
if the rack does not lift and rotate with the loading door closed. This is done automatically; nothing need
be done by the operator. After a few minutes, the oven should reset and normal operation should resume.
If it has not reset after fifteen minutes, call for service.
NOTICE
SINCE RESETS FOR THE CIRCULATION BLOWER MOTOR AND
THE LIFTER MOTOR / ROTATOR MOTOR ARE AUTOMATIC, ALL
POWER TO THE OVEN MUST BE TURNED OFF BEFORE
SERVICING.
If shutter settings are to be adjusted differently than the
recommended factory settings, the best results will be obtained
if you (A) start with the factory settings, (B) close shutters to
lighten a product in a given area- do not open shutters to darken
a product, (C) do not move a shutter more than 1/32” or 1mm
(see step gauge illustration) at any one time, (D) be sure all
settings for left hand shutters match those for right hand
shutters, and (E) do not adjust more than two shutters per side
per time (four shutters total).
Uneven Baking
If top-to-bottom is uneven, check the gap of the pressure panel shutters while the oven is cool to
determine if they match the factory settings. (There are 12 shutters per oven. See Page 20 for
Page 21 for
one step. (See step gauge illustration on page 20, 21; Feeler Gauge may also be used.) Then open one
shutter on each side of the cool area. Do not change the overall surface area of the opening.
If side-to-center bake is uneven, check the angles of the shutters with the provided Nebraska Tool to
determine if they match the factory settings. The shutter angles must be checked while oven is cool.
BARO-2.) If adjustments are still necessary, close one shutter on each side of the hot area by
BARO-1 and
There must be an air gap between the top of the finished product and the bottom
of the next highest pan, 1 1/2” minimum. The bigger the gap, the better the airflow between the
racks; the better the airflow, the more evenly the pan will cook.
ETL File 3028821 Rev B 2007 - - 18 -
GENERAL MAINTENANCE CONT’D
CAUTION
Uneven Baking Cont’d
• If an uneven bake problem cannot be corrected by the procedure just described, check the following:
• Bake Temperature- the lower the temperature the more even the bake. Higher temperatures may bake faster but
product quality can be compromised.
• The oven suction panel. Release paper sucked into the panel will reduce airflow.
• Your product. Contact your supplier to determine if there has been any change in raw or mixed product. Every new
batch of flour will cook differently.
• Your product. Closely monitor the water content of the raw product.
• Air conditioning around oven should not be blowing directly at or above oven.
• If the problem still cannot be corrected, call a Factory Authorized Service Company to check the following:
• Calibration of oven.
• Amperage on Circulation Blower Motor.
• Voltage at blower motor. If voltage varies too much or if voltage is too low airflow can be compromised and an
uneven bake may result.
• Condition of Circulation Fan.
• Gas pressure when the gas burner is on maximum 3”NG or maximum 8”LP.
• Blower rotation. If blower rotation is incorrect, it will cause an uneven bake, and severe damage to heat exchanger.
NOTICE
IF BLOWER ROTATION IS INCORRECT, IT WILL CAUSE SEVERE
DAMAGE TO HEAT EXCHANGER.
The steam, vent and fan functions cannot be used together in the
same step.
ETL File 3028821 Rev B 2007 - - 19 -
BARO-1 SHUTTER SETTINGS
NOTE: IT IS IMPORTANT THAT ADJUSTMENTS ARE
MADE AT FASTENER POSITIONS ALONG BAFFLE.
THESE POSITIONS ARE MARKED HERE BY THE
FACTORY SHUTTER POSITIONS
GENERAL MAINTENANCE CONT’D
TOP VIEW
DOWN ONTO
BAFFLE ASSEMBLY
B
.470
.440 IN.
.250
.470 IN.
.210
.500 IN.
.210
.380 IN.
.290 IN.
.210
.290 IN.
.250
.290 IN.
.250
.250
.290 IN.
.290 IN.
.250
.380 IN.
.250
.380 IN.
.410
.440
.380 IN.
.440 IN.
.470
.250
.500 IN.
.500 IN.
.210
.350 IN.
.210
.210
.290 IN.
.250
.290 IN.
.290 IN.
.250
.250
.290 IN.
.250
.320 IN.
.250
.470 IN.
.410
.470 IN.
.470 IN.
.440
CORRECT POSITION OF STEP GAUGE
IS THE STAIGHT EDGE COINCIDENT AGAINST
THE SHUTTER AT BOTH EDGES AND THEN
ADJUSTED TO DESIRED POSITION
DETAIL B
SCALE 1 : 2
ETL File 3028821 Rev B 2007 - - 20 -
GENERAL MAINTENANCE CONT’D
.41
.38
.38
.32
.32
.32
.32
.29
.29
.32
.35
.41
.41
.38
.38
.32
.32
.32
.32
.29
.29
.32
.35
.41
ETL File 3028821 Rev B 2007 - - 21 -
SAFETY CONSIDERATIONS
BELSHAW/ADAMATIC oven was manufactured to rigid standards. The oven is ETL listed as a unit, and meets safety standards.
Your
A) The responsibility of the manufacturer
the operation and maintenance of the subject units.
B) Trained, qualified personnel must perform all operation, maintenance and repair of the subject units. It is the
responsibility of the owner/operator
C) A regular periodic program of cleaning, inspection and maintenance must be established and comprehensive
maintenance records maintained. It is the sole responsibility of the user
frequency and scope of these programs in keeping with recommended practice and with due consideration given to
actual operating conditions.
D) The units must be operated within limits, which will not exceed the working limits of any component.
is to supply suitable, comprehensive instructions and recommendations for
to ensure this happens.
to establish, schedule and enforce the
ETL File 3028821 Rev B 2007 - - 22 -
PARTS LIST
1
Item Part # Description Qty.
1A 11090-34 Element, 208 Volt BARO-1 9 BARO-2 12
1B 11090-35 Element, 240 Volt BARO-1 9 BARO-2 12
1C 11090-36 Element, 480 Volt BARO-1 9 BARO-2 12
TB2 Terminal Block 2, Roof ventilator connection
TB1 Terminal Block 1, Roof ventilator connection
CB1 Circuit Breaker 3-phase power supply, 30 Amp
OL1 Over Load Circuit Protection, Circulation Blower
Ballast 120 V Lamp Ballast
CB4 Circuit Breaker 1-phase 120V Line supply, 15 Amp
CB5 Circuit Breaker 1-phase 120V Line (Jump from CB4), 15 Amp
TB3 Terminal Block, 120V Neutral Supply
OL2 Lift and Rotation Motor Overload Protection
TR1 Transformer (120V – 10V) Control Circuit (no installed on hot
surface models)
TR2 Transformer (120V – 24V) All Controls
MR1 Main 120V supply (Note: On models with serial #’s
beginning in S- this is MR2)
MR2 4 Pole Circulation Blower contactor, Heat call safety
(Note: On models with serial #’s beginning in S- this
is MR1)
MR3 24 V 1 set of contacts for CPU door switch, 1 set of points
for MR4
MR4 Coil controlled by MR3 and rotation switch. Points control Lift
actuator in N/C and rotation motor in N/O.
MR5 OL2 controls coil. Points control linear actuator and rotation.
MR6 Vent control
MR7,8 & 9 MR7, electric ovens. MR7,8,9 Back-up controls only
Note: On models
with serial #’s
beginning with Sthis is MR1
Note: On
models with
serial #’s
beginning
with S- this
is MR2
ETL File 3028821 Rev B 2007 -- 33 -
WIRING DIAGRAM
ETL File 3028821 Rev B 2007 - - 34 -
WIRING DIAGRAM CONT’D
NEUTRAL
CB-1
CB-2
CB-3
135
R1R2R3
264
CONTACTOR # 1
CONTROLS ELEMENTS
1,2 & 3
CB-4
CB-5
CB-6
7911
R4R5R6
81210
CONTACTOR # 2
CONTROLS ELEMENTS
4,5 & 6
Heat Call
from
Circuit Board
47
45
131517
R7R8R9
141816
CB-7
CB-8
CB-9
CONTACTOR # 3
CONTROLS ELEMENTS
7,8 & 9
Air
Switch
49
45
High
Limit
MR2
MOTOR REL AY
NORMALY OPEN
MR-7
120 VAC
LANG MODEL
HEATER CIRCUIT
BARO-E Heat Circuit
Diagram
61111-176
ETL File 3028821 RevB2007 35
BARO Troubleshooting Manual
ETL File 3028821 RevB2007 36
Measure the probe resistance against actual temperature in the Pressure Panel, not Control
Panel Display temperature. Place thermocouple in Pressure Panel just behind louvers about waist
high, not in center of oven
when reading air temperature.
70403-03 Water Valve 3.5
70403-04 120V Vent Solenoid 80
30701-05 Relay 24V 35
80505-14 Gas Valve MV Pins 1-2 62
30700-14 Motor Contactor 5.5
11090-34 208V Element 10
11090-35 240V Element 14
11090-36 480V Element 52
. Make sure tip of thermocouple does not come in contact with metal
ETL File 3028821 RevB2007 37
No Heat, Low Heat
Door Open? Preheating in Display? If No, check Door Switch and MR3 for
1.
normal operation. Jump J5 to test board.
2.
Blower Delay On? If Yes, note that oven will not heat while blower delay is on
until set time elapses.
3.
Board Calling for Heat? LD3 will illuminate when heat relay is closed; 24V
from wire 4 (circuit board) to wire 45 (transformer) should then be present. Use
ground for reference in place of wire 45. Verify ohm reading on probe. (See p. 22 for
Resistance Chart.) If probe is open board will not call for heat.
Ventilator Blower Working, Air Switch Proving? Check for 24V to
4.
ground. Jump out air switch to test. Check for water in air switch. Bend an upward
loop in air tube to keep out water. Check for required air flow: Singles 1520 FPM @
530 CFM, Doubles 2300 FPM @ 800 CFM. A negative draw of 0.6” Water Column is
necessary to close air switch. This can be an intermittent issue, if the motor is
tripping on thermal overload or pulling a borderline volume of air it can look
like an oven issue. Keep checking the Water Column if air switch is
intermittently opening.
5. High Limit Closed? Test circuit. Is multi wire connector disconnected at lifter?
Circulation Blower Running/Contactor Closed? 24V present between 54
6.
and 45? Overload tripped? MR1 operating properly (5.5 on coil)? Multi wire
connector disconnected at lifter?
Power to Heat Circuit? 24V present to wires 54 & 45 on coil of MR7?
7.
Check coil of MR7 for 35. MR7 operating properly? 120V present at 3 heat
contactor coils? Check contactor coils for 87. At this point 208V, 240V or 480V
should be present at elements. Check Elements for proper resistance and shorts to
ground. 208V 10 - 240V 14 - 480V 52
ETL File 3028821 RevB2007 38
Temperature Erratic
1. Temperature Jumping? Verify blower direction is counterclockwise when
viewed from top
timer is running. Display temperature will jump around dramatically when Automatic
Energy Management System turns on and off, after preheat temperature is achieved;
this is a normal energy saving feature. If this happens before preheat temperature is
achieved contact factory @ 1-888-722-5686.
. Make sure a program is correct (0 blower delay) and countdown
No Steam
1. Oven Hot? Preheat oven to at least 300º for at least 20 minutes before steam cycle.
Wait at least 20 minutes between cycles.
2. Board Calling for Steam? LD5 will illuminate when heat relay is closed; 24V
from wire 52 (circuit board) to wire 45 (transformer) should then be present.
3. Got Water? Check water supply to valve; make sure cutoff valve is wide open.
Solenoid valve is supplied; 24V from circuit board wire 52 and transformer wire 45.
Solenoid coil should be 3.5. Make sure water feed tubes are free of debris and scale.
No Rack Lift and, or Light
1. Door Open, Preheating in Display? If No, check Door Switch and MR3; 35
on coil and 24V to coil, points open and close for normal operation. Jump J5 to test
board.
Board Calling for Carousel and Light? LD4 will illuminate when carousel
2.
relay is closed; 24V from wire 46 (circuit board) to 45 (transformer) should then be
present at MR2. MR2 should then close and oven lights should turn on.
3.
Light off, Rack will not Lift: Check CB4 & CB5 for proper operation, 120V
from load side to neutral bar (TB3). See also above, Board calling for Carousel,
Light?
ETL File 3028821 RevB2007 39
Cont’d
Cont’d
4. Light off, Rack will not Lift: Check CB4 & CB5 for proper operation, 120V
from load side to neutral bar (TB3). See also above, Board calling for Carousel,
Light?
5. Light on, Rack will not lift:Check MR5 for normal operation, 35 on coil
and 24V to coil, points open and close. Check OL2 for normal operation,
MR5 and 120V to MR4 NC and NO. Check MR3 for normal operation
coil and 24V to coil, points open and close. Check MR4 for normal operation
on coil and 24V to coil, points open and close. Check upper switch
assembly for proper operation. At this point you should have 120V on wire 16 and
wire 2 on the lift actuator and it should lift. Check Floor Anchors;
anchored well, when heated it can warp at center sufficient to hold up rack. Check
Racks
for proper height.
on limit switch
if floor is not
24V to
, 35 on
, 35
Rack Continues to Rotate
1. Door Open? If Yes, Check Door Switch (MS1) and Rack Alignment Switch
(MS2) for normal operation. Check MR3 for normal operation
close. Check MR4 for normal operationswitch, on limit switch assembly for proper operation. At this point you should have
120V on wire 18 and wire 2 on the lift actuator and it should lower until the lower
limit switch opens.
, points open and close. Check lower
, points open and
Rack Lifts, Does Not Rotate
1. Rotate Motor Running? If Yes, check for jammed Pan, Oil on Friction Clutch,
Chain or Sprocket loose. Check oven level and Shaft plumb.
2. Rotate Motor Running? If No, Check upper switch on limit switch assembly
for proper operation. At this point you should have 120V on wire 15 and wire 2 and
the motor should rotate. Rotate Capacitor failed,
Motor failed.
ETL File 3028821 RevB2007 40
Uneven Bake, Burning
1. Circulation Blower Motor Running Backwards? Motor should spin
counterclockwise as viewed from the top of the oven.
2. Timer Not Counting Down? Allow oven to preheat. Press Start. Energy saving
mode will shut off blower and heat and cause uneven baking and longer bake times.
3. Bake Temps Too High? Lower Temps = a more even bake. Baking temps
should be about 50º F lower and times should be about 10% less then standard (non
convection) bake oven recipes.
4. Product not thawed evenly or from different batches?
5. Paper in air ducting or in circulation blower?
6. Air Shutters out of Adjustment? See service manual or contact factory.
7. Calibration Accurate? Temps taken in pressure panel, not center of oven. See
operation instructions or contact factory to enter calibration mode.
No Display (LCD)
1. No Display:Check CB4 and CB5 for proper operation, 120V from load side to
neutral bar (TB3); at this point you should have 120V to primary side of control
transformer via wires 2 and 3. Check Transformer:
transformer 4.5; Secondary (24V) side .5; Secondary center tap (12V) .3. At this
point you should have 12VAC to J1 on Relay Board and LD8 should be illuminated.
Check Communication Cable
display board); at this point LD1 and LD2 on CPU should illuminate. When start
button is pressed the button board sends info to the CPU and both LCD display and
LED Temp should illuminate.
connection (grey cable between relay board and
Primary (120V) side of
ETL File 3028821 RevB2007 41
No Display(LCD), cont’d
2. Lines in Display? Display is hot; let it cool and lines should fade. Note: If display
is exposed to continuous high heat this condition may be permanent. If condition
recurs a cooling fan may be necessary.
3. Display Hard to Read? A small, square grey trim pot for adjusting display
contrast is located on the top right corner of CPU/LCD.
No Display (LED)
1. Time/Temp Display Will Not Turn On: Turn off 120V CB4 and CB5 and
then turn back on. If display comes back on contact factory.
2. No Countdown Time: Press Start. Cooking in Energy Saving Mode will cause
uneven bake and longer bake times.
ETL File 3028821 RevB2007 42
CLEANING FOR RACK OVENS & PROOFERS
Read First
Contrary to popular belief stainless steel is susceptible to rusting. Stainless steel is a
passive metal because it has an invisible passive film that covers the surface acting as a
shield against corrosion. If this passive film is broken down corrosion can set in and
begin to spread.
The three primary enemies of stainless steel are:
1.Mechanical abrasion: Anything that will scratch the steel’s surface. Steel pads,
wire brushes, and metallic scrapers are the most common culprits.
2.Water: Hard water leaves deposits that will break down the passive layer and
begin corroding your stainless steel. A water test with a reputable water company
is always a good idea to assure your water quality is up to par.
3.Chlorides and Chloride Cleaners: Chlorides are in water, food, and table salt.
The worst chloride invasion, however, comes from household and industrial
cleaners not made for stainless steel.
Daily Cleaning
Use proper cleaners and tools. Use alkaline, alkaline chlorinated or non-chloride
containing cleaners with soft cloths, soft bristled brushes, plastic scrapers, and plastic
scouring pads.
1. Let unit cool.
2. Sweep floor with heat resistant (straw) broom.
3. Clean both sides of oven window with mild soap and water.
4. Clean control panel with mild soap and water.
5. Clean handle with mild soap and water.
Weekly Cleaning
Use proper cleaners and tools. Use alkaline, alkaline chlorinated or non-chloride
containing cleaners with soft cloths, soft bristled brushes, plastic scrapers, and plastic
scouring pads.
1. Perform daily cleaning.
2. Clean interior stainless steel surfaces with a stainless safe cleaner. Dish soap,
ammonia, detergent, and Medallion are all good choices. Rinse with clean water
and dry immediately. The quicker you wipe off standing water that contains
cleaning agents, the better.
Monthly Cleaning
Use proper cleaners and tools. Use alkaline, alkaline chlorinated or non-chloride
containing cleaners with soft cloths, soft bristled brushes, plastic scrapers, and plastic
scouring pads.
1. Perform daily cleaning.
2. Perform weekly cleaning
3. Remove hood filters from oven and clean interior of hood and filters. Make sure
all filters and spacers are reinserted. If not reinserted the lack of vent suction may
keep the oven from heating; also the hood may no longer meet code.
4. Turn off all three circuit breakers on ovens located behind the control panel door.
5. Clean exterior stainless steel surfaces. Dish soap, ammonia, detergent, and
Medallion are all good choices. Rinse with clean water and dry immediately. The
quicker you wipe off standing water that contains cleaning agents, the better.
6. Turn on all three oven circuit breakers.
Quarterly
If water filters are installed contact your water treatment vendor for filter replacement.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.