Job______________ Item #_________________
ADAMATIC
________________________________________________________________________________________________________
Adamatic
Model AP-2W
Double Wide
Proof Box Series
Standard Features:
•
Full stainless steel construction
300 series s/s interior
400 series s/s exterior
• Internally mounted air-wash
humidification system
• Modular cam lock wall and roof construction
•
Interior and exterior bumper guards
•
Accommodates up to 75” tall racks and up to
20” x 30” pan size
•
2” polyurethane insulated wall/roof panels
•
Eye level digital control panel features:
-Temperature control
-Humidity control
-Countdown timers
-Main power switch
•
Three heavy duty cam lift hinges (w/stay Models:
stay feature) per door Inside Depth Without floor With floor
•
Heavy duty door closures 28” AP-2W-028 AP-2W-028F
•
Multiple depths available 38” AP-2W-038 AP-2W-038F
•
One year parts/labor warranty 48” AP-2W-048 AP-2W-048F
58” AP-2W-058 AP-2W-058F
Options: 68” AP-2W-068 AP-2W-068F
• Upper closure panel 78” AP-2W-078 AP-2W-078F
• Side closure panel (one or both sides) 118” AP-2W-118 AP-2W-118F
• Pass-thru
• Heavy duty stainless steel floor
• Correctional package
• Shipped assembled (28”/38”/48” units only)
________________
Adamatic
607 Industrial Way West
Eatontown, N.J. 07724
Phone: 732-544-8400
Fax : 732-544-1216
Website: www.adamatic.com
ADAMATIC Double Wide Proof Box
____________________________________________________
Interior/Exterior Depth Dimensions
Model Number
AP-2W-028 28” 31”
AP-2W-038 38” 41”
AP-2W-048 48” 51”
AP-2W-058 58” 61”
AP-2W-068 68” 71”
AP-2W-078 78” 81”
AP-2W-118 118” 121”
Note: for pass-thru models add 3” to exterior depth
dimension. Interior depth dimension remains the same.
Rack Capacity Single End Load Single Side Load Double End Load
AP-2W-028 2 2 0
AP-2W-038 2 4 2
AP-2W-048 4 5 2
AP-2W-058 4 6 4
AP-2W-068 6 6 4
AP-2W-078 6 8 4
AP-2W-118 8 10 6
Note: Above capacities are for standard 18x26 sheet pan racks. Consult factory for proof box capacity on
other pan sizes or rack capacities.
A= Interior Depth B=Exterior Depth
Utility Specifications/Shipping Weight
Model
AP-2W-028 240/60/3 @ 14.8 amps 4.5 3/8” NPT 1/2” NPT 900 lbs
AP-2W-038 240/60/3 @ 14.8 amps 4.5 3/8” NPT 1/2” NPT 950 lbs
AP-2W-048 240/60/3 @ 14.8 amps 4.5 3/8” NPT 1/2” NPT 1050 lbs
AP-2W-058 240/60/3 @ 18.5 amps 6 3/8” NPT 1/2” NPT 1150 lbs
AP-2W-068 240/60/3 @ 18.5 amps 6 3/8” NPT 1/2” NPT 1200 lbs
AP-2W-078 240/60/3 @ 27.7 amps 9 3/8” NPT 1/2” NPT 1250 lbs
AP-2W-118 240/60/3 @ 27.7 amps 9 3/8” NPT 1/2” NPT 1500 lbs
Electrical (1) Power Input Kw Water (2) Drain (3) Shipping Weight
Notes:
(1) Single point electrical connection located on the top rear of the box. 37” from left hand corn er, 6” from the rear, 84” fr om
the floor .
(2) Water supply conn ection. Hot or cold water supp ly @25-50 psi. Located 6” from the front left side, 20” from front, 84” from
floor. For proper operation of the steam system it is recommended that the water supply follow these specifications: Hardness
of 2-4 grains per gallon, p h range of 7.0 to 8.0 and chloride concentration of 0-30 ppm. Consult your water treatment company
for proper water filtration system.
(3) Drain factory equipped for rear exit (can be field modified for front exit). Drain exit located 4 1/2” from rear left hand corner,
5” from floor. Drain must be installed angled to floor prior to routing to drain source for proper drainage.
A hard smooth level floor is required on which to po sition the proof box and access for maintenance is located on the top or
inside the unit. It is recommended that a minimum of 24” be available on top of the proof box for servicing.
Proof Box installation mu st be performed by factory authorized technicians and all utility connect ions must be performed by
licensed contractors to meet all federal, state and local codes.
We reserve the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.
____________________________________________________
Part of AGA Foodservice Group © Copyright October 2003 Printed in U.S.A.