ACR Electronics HRU Installation

0 (0)
ACR Electronics HRU Installation

CAUTION: Before proceeding to install, test or use your new ACR Electronics’ product, please read this Product Support Manual in its entirety.

If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981-3333. Please be ready to provide the technician with the page number you wish to discuss. If you have a question that is not covered in the manual, please visit our website and access the Frequently Asked Questions (FAQs) section for further information or call our Technical Service Department. The website address is www.acrelectronics.com. If in the future you lose this manual, you may access and print a replacement on the ACR website.

Y1-06-0209G

1

Table of Contents

SECTION 1 – INTRODUCTION _______________________________ 3 SECTION 2 – PREPARING TO INSTALL ________________________ 4 SECTION 3 – HOW TO DETERMINE HRU EXPIRATION DATE _______ 6 SECTION 4 – INSTALLING THE HRU IN A SeaShelter3™ BRACKET ___ 7 SECTION 5 – INSTALLING THE HRU IN A SeaShelter2™ BRACKET ___ 9 SECTION 6 – INSTALLING THE HRU IN A SeaShelter™ BRACKET __ 11 SECTION 7 – INSTALLING THE HRU IN AN OPEN FACED BRACKET _ 13 SECTION 8 – INSTALLING THE HRU IN A CAPSULE BRACKET______ 15

APPENDIX A – WARRANTY, USEFUL LIFE POLICY, NOTICES _______ 17

PLEASE READ ALL WARNINGS, CAUTIONS

AND NOTES CAREFULLY

Y1-06-0209G

2

SECTION 1 – INTRODUCTION

Congratulations and thank you for purchasing the ACR HydroFix™ Hydrostatic Release Unit (HRU) replacement for your ACR Category I EPIRB.

ACR designs, manufactures and distributes quality products knowing they are used to save lives. Many of our products are required to be tested and approved by regulatory bodies worldwide. We believe in going beyond those specifications to ensure our products work when needed in real world conditions. With proper care and maintenance your ACR product will last for years.

ACR is proud to be certified to ISO 9001: 2000, the International Standard for Quality.

This manual provides installation instructions for the HydroFix™ Hydrostatic Release Unit (HRU).

Y1-06-0209G

3

Figure 1

SECTION 2 – PREPARING TO INSTALL

UNPACKING THE HydroFix™ HRU

The HydroFix™ HRU Kit is a universal kit in that it is used for all Category I ACR EPIRBs. The kit components that are required to replace the HRU in a particular model will vary with the EPIRB bracket you are servicing. The content of the universal HRU kit includes the following:

Figure 1 items:

ACategory I bracket (SeaShelter™) release rod

BCapsule design release rod

COpen faced release rod

DKeyed bracket adapter

EReplacement hydrostatic release unit (HRU)

FMounting screws (4)

GCotter pin, small

HCotter pin, large

ISlotted spring pin (2)

JMounting bracket adapter (2)

KHRU expiration label

LMounting rod adapter (metal)

MCategory I bracket (SeaShelter™3) release rod

Y1-06-0209G

4

If any of the above is missing, please contact ACR Electronics’

Technical Service by email at service@acrelectronics,com or by phone at +1 (954) 9813333.

Equipment that may be required but is not included:

//Black indelible marker

//Phillips-head screwdriver

//Flat-head screwdriver

//Pliers

Notes, Cautions and Warnings

The following notes, cautions and warnings apply to all EPIRBs and must be followed for personal safety and proper HRU replacement.

WARNING: Failure to replace the entire assembly can cause the bracket to malfunction.

WARNING: Do not use any parts from the old HRU (the one being replaced).

WARNING: The HRU holds down the ejector spring. Take great care to hold the spring in place during removal and installation of the new HRU to prevent injury.

WARNING: Stow the EPIRB in a dry location as it will activate if out of the bracket and wet.

WARNING: Non-ACR-supplied hydrostatic release units must not be installed in ACR Category I EPIRB brackets. ACR cannot and does not warrant the performance of other manufacturers’ products. Installation of a non-ACR-supplied HRU voids the warranty and potentially jeopardizes your safety.

CAUTION: Visually check the EPIRB when removing it from the bracket. It must be sent back to ACR for check up and/or refurbishment if ANY of the following conditions exist:

Cracks to the exterior plastics

Activation indicator break tab is broken

Moisture appears inside the EPIRB

Lacquer is not present in one of the screws or appears to have been tampered with

NOTE: Some parts in this kit will not be used. Refer to Figure 1 and the instructions for your specific model for details. Discard unused parts.

Y1-06-0209G

5