ABB C571 Catalog Page

C571
Electronic
Type C571
Voltage range Output contacts Enable contacts Auxiliary Safety Weight Piece Catalog List 50/60Hz VDC Instan- Time
taneous delay
24VAC 24VDC 2 N.O. — — 3, (4)1 1SAR501020R0001 24VDC 2 N.O. 3, (4) 115 VAC — 2 N.O. 3, (4) 230 VAC — 2 N.O. 3, (4)
category (oz.) per unit number price
1
8.47 1
1 1SAR501020R0004 1 1SAR501020R0005
1SAR501020R0003
Safety relays
Description
Emergency Stop monitor and safety gate monitor C571
• Auto-start / monitored start
• Operating voltage Vc at Emergency Stop button or limit switch
• Feedback loop for monitoring of external contactors
• LED indicators for power, channel 1 and 2
• Safety outputs: 2 N.O. contacts, positively guided
• Width of enclosure: 22.5mm
Application
Use the safety control gears C571/C573 in Emergency Stop devices as per EN418 and in safety circuits as per VDE 0113 Part 1 (11.98) and/or EN 60 204-1 (11.98), e.g., with moveable covers and guard doors. Depending on the external connections, categories 3 and 4 (with additional external measures) as per DIN EN 954-1 are achievable.
7
$ 280
7
1 Possible with additional external measures. The digit in parenthesis applies only if the cables and sensors are laid safely and protected
mechanically.
Low Voltage Products & Systems 7.21
AC 1000 - 11/03
Discount schedule AR
Loading...