3M E-9E Installation Manual

Page 1
Scotchlok
Instructions
Connectors and Tools
July 1994 Issue 2, 80-6107-4684-6
Page 2
Scotchlok Connector
TM
Connection
Type
Maximum Insulation
O. D.
in
mm
Butt Splicing
PIC-unfilled
AWG
mm
Cable Type
PIC-filled Pulp or Paper
AWG mm
AWG
Approved Tools
To reduce fatigue, use tool within each splicing group with highest mechanical advantage indicated in ( ).
mm
*
UR2
**
UR2-D
*
UY2
**
UY2-D
***
UP2
***
UP3
*
211
*
UB2A
**
UB2A-D
***
UPB
.082 2.08 19-26 .9-.4
.082 2.08
.082 2.08
.082 2.08
.060
.066 1.67 22-26 .7-.4 19-26 .9-.419-26
.082 2.08 19-26 .9-.4 19-26 .9-.4 19-26 .9-.4
19-26 .9-.4 19-26 .9-.4
19-26 .9-.4
19-26 .9-.4
1.52
22-26 .7-.4
19-26 .9-.4 N A
19-26 .9-.4
19-26 .9-.4 19-26 .9-.4
22-26 .7-.4 22-26 .7-.4
.9-.4
19-26 .9-.4
N A
Tap Splicing
.082 2.08
.082 2.08
.050
19-26 .9-.4 19-26 .9-.4 N A
19-26 .9-.4 19-26 .9-.4 19-26 .9-.4
1.27
22-26 .7-.4
24-26 .5-.4
Can be used on 22 (.7) foam insulated cable
22-26 .7-.4
E-9BM
(10-1)
E-9C/CW (7-1)
E-9E (4-1)
E-9Y (3-1)
E-9E (4-1) E-9BM (10-1) E-9Y (3-1)
E-9BM
(10-1)
E-9E (4-1)
E-9Y (3-1)
*
UDW2
*
UCC
***
UPC
Filled
*
Unfilled
**
Unfilled - Flame Retardant
***
NA Not Applicable
In Line Splicing
Self-stripping drop wire connector designed to accommodate copper or copper clad steel conductors 16-19 AWG (1.3-0.9 mm)
.175 4.4
in strain relief areas. Ideal for use on Alpha Duct GT-7, Alpha TEL, F-Drop and C-Drop.
Clear / Cap Only
.060 1.52
.060
22-26 .7-.4 22-26 .7-.4 N A
22-26 .7-.4
1.52
E-9BM
(10-1)
ALL TOOLS APPROVED FOR BUTT SPLICING MAY BE USED
22-26
.7-.422-26
.7-.4
Note: For health and safety information for
sealant in filled Scotchlok Connectors, see package label or appropriate Material Safety Data Sheet.
Page 3
UR2 UR2-D UY2 UY2-D UP2 UP3 UCC UPC
Trim, straighten conductors
211
Connector to be removed
Place 211 connector
UB2A UB2A-D UPB
Place side slot on run wire
Pre-crimp
UDW2
Cut and slit drop wire 1- 1/4''
Separate, fully insert conductors
Insert fully matching line or ribs of drop wire
Pre-crimp
Twist, cut, insert tap wire
Crimp with cap side down
Pre-crimp raised side
Pre-crimp
Crimp with cap side down
Test port
Crimp with cap side down
Crimp with cap side down
REMEMBER
On ratchet tools (E-9C, E-9CH )
Squeeze handle until ratchet releases
E9Y tool should not be used when
crimping three 19 AWG/ .9 mm conductors
To reduce fatigue, use tool with highest mechanical advantage
Periodically gauge tools and connectors
Page 4
Important Notice
All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use.
Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties, express or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed.
SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECT OR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS THAT WERE DEFECTIVE.
Telecom Systems Division
6801 River Place Blvd. Austin, TX 78726-9000 800/426-8688
Printed on 50% recycled paper
with 10% post consumer
© 3M 1994 80-6107-4684-6 (835.0)TG1
Printed in USA